Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

SU-E-T-350: Verification of Gating Performance of a New Elekta Gating Solution: Response Kit and Catalyst System

Purpose: In this work, we have tested the performance of new respiratory gating solutions for Elekta linacs. These solutions include the Response gating and the C-RAD Catalyst surface mapping system.Verification measurements have been performed for a series of clinical cases. We also examined the beam on latency of the system and its impact on delivery efficiency. Methods: To verify the benefits of tighter gating windows, a Quasar Respiratory Motion Platform was used. Its vertical-motion plate acted as a respiration surrogate and was tracked by the Catalyst system to generate gating signals. A MatriXX ion-chamber array was mounted on its longitudinal-moving platform. Clinical plans are delivered to a stationary and moving Matrix array at 100%, 50% and 30% gating windows and gamma scores were calculated comparing moving delivery results to the stationary result. It is important to note that as one moves to tighter gating windows, the delivery efficiency will be impacted by the linac's beam-on latency. Using a specialized software package, we generated beam-on signals of lengths of 1000ms, 600ms, 450ms, 400ms, 350ms and 300ms. As the gating windows get tighter, one can expect to reach a point where the dose rate will fall to nearly zero, indicating that the gating window is close to beam-on latency. A clinically useful gating window needs to be significantly longer than the latency for the linac. Results: As expected, the use of tighter gating windows improved delivery accuracy. However, a lower limit of the gating window, largely defined by linac beam-on latency, exists at around 300ms. Conclusion: The Response gating kit, combined with the C-RAD Catalyst, provides an effective solution for respiratorygated treatment delivery. Careful patient selection, gating window design, even visual/audio coaching may be necessary to ensure both delivery quality and efficiency. This research project is funded by Elekta.

07 ISOTOPE AND RADIATION SOURCES↗

Stockpile Stewardship and Nuclear Testing: A Technical Assessment

Since 1992, the United States has retained confidence in its nuclear weapon stockpile without performing any tests that produce nuclear yield. Instead, it has invested in a stockpile stewardship program (SSP) based on the same approach that was validated through fifty years of experience during the nuclear testing era. As the test moratorium continues and new information becomes available, it is both necessary and appropriate to periodically revisit the question of whether or not nuclear testing should resume. In a recent article by Dr. Mark Schneider, he asserts that the United States should return to nuclear testing to address the issues that negatively affect our country’s nuclear deterrent. A serious, technically informed evaluation of the most significant of the issues Dr. Schneider has raised is provided in this paper. The conclusion of this evaluation is that the strategy of a well-funded SSP coupled with rigorous assessments to identify if there is a specific need for a nuclear test is sound and cost-effective approach. Any decision otherwise needs to take into careful consideration all the classified SSP successes and data pertaining to the particular issues in question.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Renovation of Thermal Vacuum Chambers at Idaho National Laboratory for Testing of Radioisotope Power Systems

The Radioisotope Power Systems (RPS) program at Idaho National Laboratory (INL) fuels and performs environmental testing of RPS in support of National Aeronautics and Space Administration (NASA) missions. Recently the programs’ thermal vacuum chambers, housed within INL’s Space and Security Power Systems Facility (SSPSF), underwent successful renovations to improve functional capabilities and system control in support of customer missions. Thermal vacuum system renovations focused primarily on three core functions. The first focus area was integration of semi-automated Programmable Logic Controllers (PLC) to enhance operational feedback and process control. This included the use of numerically controlled vacuum valves and integration of real time feedback from process pressure transducers. Improvements to the system high vacuum pumping technology was the second priority focus. Legacy diffusion pumps were replaced with turbo-molecular and cryogenic pumps to help mitigate the possibility of back streaming diffusion pump oil onto the surface of the test article or radiative cooling surfaces located within the chambers. The third and final core function involved meeting emergent customer thermal requirements. This led to retro-fitting one of the vacuum chambers with a cryogenically cooled Thermal Conditioning Unit (TCU) and thermal shrouds. The TCU utilizes gaseous nitrogen to heat or cool a cylindrical shroud to maintain a set temperature with a programmable range of -I85 °C to I00 °C. With the successful completion of RPS acceptance testing, the newly renovated thermal vacuum chamber systems are operational and better equipped to support testing of Radioisotope Power Systems for space exploration missions.

42 ENGINEERING↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

AGR-1 Compact 5-3-1 Post-Irradiation Examination Results

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program was established to perform the requisite research and development on tristructural isotropic (TRISO) coated particle fuel to support deployment of a high-temperature gas-cooled reactor (HTGR). The work continues as part of the Advanced Reactor Technologies (ART) TRISO Fuel program. The overarching program goal is to provide a baseline fuel qualification data set to support licensing and operation of an HTGR. To achieve these goals, the program includes the elements of fuel fabrication, irradiation, post-irradiation examination (PIE) and safety testing, fuel performance, and fission product transport (INL 2015). A series of fuel irradiation experiments is being planned and conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). These experiments will provide data on fuel performance under irradiation, support fuel process development, qualify the fuel for normal operating conditions, provide irradiated fuel for safety testing, and support the development of fuel performance and fission product transport models. The first of these irradiation tests, designated AGR-1, began in the ATR in December 2006 and ended in November 2009. This experiment was conducted primarily to act as a shakedown test of the multicapsule test train design and provide early data on fuel performance for use in fuel fabrication process development. It also provided samples for post-irradiation safety testing, where fission product retention of the fuel at high temperatures will be experimentally measured. The capsule design and details of the AGR-1 experiment have been presented previously.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AGR-1 Compact 1-3-1 Post-Irradiation Examination Results

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program was established to perform the requisite research and development on tristructural isotropic (TRISO) coated particle fuel to support deployment of a high-temperature gas-cooled reactor (HTGR). The work continues as part of the Advanced Reactor Technologies (ART) TRISO Fuel program. The overarching program goal is to provide a baseline fuel qualification data set to support licensing and operation of an HTGR. To achieve these goals, the program includes the elements of fuel fabrication, irradiation, post-irradiation examination (PIE) and safety testing, fuel performance modeling, and fission product transport (INL 2015). A series of fuel irradiation experiments is being planned and conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). These experiments will provide data on fuel performance under irradiation, support fuel process development, qualify the fuel for normal operating conditions, provide irradiated fuel for safety testing, and support the development of fuel performance and fission product transport models. The first of these irradiation tests, designated AGR-1, began in the ATR in December 2006 and ended in November 2009. This experiment was conducted primarily to act as a shakedown test of the multicapsule test train design and provide early data on fuel performance for use in fuel fabrication process development. It also provided samples for post-irradiation safety testing, where fission product retention of the fuel at high temperatures will be experimentally measured. The capsule design and details of the AGR-1 experiment have been presented previously (Grover, Petti, and Maki 2010, Maki 2009).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Human machine interface to manually drive rhombic like vehicles such as transport casks in ITER

The Cask and Plug Remote Handling System (CPRHS) and the respective Cask Transfer System (CTS) are designed to transport activated components between the reactor and the hot cell buildings of ITER during maintenance operations. In nominal operation, the CPRHS/CTS shall operate autonomously under human supervision. However, in some unexpected situations, the automatic mode must be overridden and the vehicle must be remotely guided by a human operator due to the harsh conditions of the environment. The CPRHS/CTS is a rhombic-like vehicle with two independent steerable and drivable wheels along its longitudinal axis, giving it omni-directional capabilities. During manual guidance, the human operator has to deal with four degrees of freedom, namely the orientations and speeds of two wheels. This work proposes a Human Machine Interface (HMI) to manage the degrees of freedom and to remotely guide the CPRHS/CTS in ITER taking the most advantages of rhombic like capabilities. Previous work was done to drive each wheel independently, i.e., control the orientation and speed of each wheel independently. The results have shown that the proposed solution is inefficient. The attention of the human operator becomes focused in a single wheel. In addition, the proposed solution cannot assure that the commands accomplish the physical constrains of the vehicle, resulting in slippage or even in clashes. This work proposes a solution that consists in the control of the vehicle looking at the position of its center of mass and its heading in the world frame. The solution is implemented using a rotational disk to control the vehicle heading and a common analogue joystick to control the vector speed of the center of the mass of the vehicle. The number of degrees of freedom reduces to three, i.e., two angles (vehicle heading and the orientation of the vector speed) and a scalar (the magnitude of the speed vector). This is possible using a kinematic model based on the vehicle Instantaneous Center of Rotation (ICR): a geometric approach where, at each time instant, the vehicle describes a circumference (either with a finite or infinite radius). The inverse of the kinematic model transforms the three input parameters of the center of mass into the four parameters for the wheels, preserving the omni-directional capabilities. The solution is implemented and tested using a HMI with a control disk and an analog joystick with two axis. The control disk was specially designed for this solution and implemented using a programmable micro-controller. In the first set of experiments, the HMI communicates with a computer running a simulator of the CPRHS/CTS, with the vehicle kinematics and dynamics, moving in a map of the ITER buildings. In the second set of experiments, the HMI communicates with a scaled prototype of the CPRHS running in a mock-up scenario to obtain more realistic results. Several type of tests were performed to evaluate the usability of the HMI. Different human operators without knowledge neither experience with this interface were invited to test the HMI. The operators had to drive the vehicle from an initial place to a final destination under the following conditions: with a pre-computed path to help guidance, without any path, with the information of the closest obstacles and without any help. The performance was evaluated using the time duration of the operation, the energy required to perform the described path, the risk of collision and, in case of a pre-computed path, the comparison between paths. In addition, each operator tested the HMI several times to evaluate the performance along consecutive trials. (authors)

42 ENGINEERING↗

Functional fiber-optic sensors embedded in stainless steel components using ultrasonic additive manufacturing for distributed temperature and strain measurements

The nuclear industry is progressing toward microreactors that can be factory assembled and deployed to remote regions for reliable, scalable power generation. However, the reduced power output requires enhanced monitoring capabilities to reduce staffing and eventually move toward autonomous control to improve the economics of microreactors. The ability to embed sensors such as fiber-optics, which can provide spatially distributed temperature and strain measurements, within microreactor components for real-time health monitoring would be particularly advantageous. Recent advances in ultrasonic additive manufacturing (UAM) have demonstrated the successful embedding of fiber-optics in soft materials such as Al and Cu by placing the sensors in machined cavities and ultrasonically welding over the top with thin foils. This article reports the first successful embedment of fiber-optic sensors and thermocouples within a common nuclear reactor material, SS304, via UAM. UAM parameters were first explored with simple plate geometries before moving to more complex geometries, such as pipes and other test articles for heat pipe–based microreactors. Select samples were sectioned for microscopy to evaluate the sensor/foil and foil/foil interfaces from samples fabricated by using 100% SS304 foils vs. foils plated with a Ni coating to improve UAM bonding. Furthermore, embedding metal-coated, low-bend loss fibers resulted in greatly reduced signal attenuation and adequate compressive residual strain in the embedded region to ensure successful strain coupling. Pipe specimen functional testing was performed by monitoring temperature and strain during transient and steady-state thermal testing.

36 MATERIALS SCIENCE↗

Data-driven design of metal–organic frameworks for wet flue gas CO 2 capture

Limiting the increase of CO 2 in the atmosphere is one of the largest challenges of our generation. Because carbon capture and storage is one of the few viable technologies that can mitigate current CO 2 emissions, much effort is focused on developing solid adsorbents that can efficiently capture CO 2 from flue gases emitted from anthropogenic sources. One class of materials that has attracted considerable interest in this context is metal-organic frameworks (MOFs), in which the careful combination of organic ligands with metal-ion nodes can, in principle, give rise to innumerable structurally and chemically distinct nanoporous MOFs. However, many MOFs that are optimized for the separation of CO 2 from nitrogen do not perform well when using realistic flue gas that contains water, because water competes with CO 2 for the same adsorption sites and thereby causes the materials to lose their selectivity. Although flue gases can be dried, this renders the capture process prohibitively expensive. Here we show that data mining of a computational screening library of over 300,000 MOFs can identify different classes of strong CO 2 -binding sites-which we term 'adsorbaphores'-that endow MOFs with CO 2 /N 2 selectivity that persists in wet flue gases. We subsequently synthesized two water-stable MOFs containing the most hydrophobic adsorbaphore, and found that their carbon-capture performance is not affected by water and outperforms that of some commercial materials. Testing the performance of these MOFs in an industrial setting and consideration of the full capture process-including the targeted CO 2 sink, such as geological storage or serving as a carbon source for the chemical industry-will be necessary to identify the optimal separation material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A 5- μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering

Here, we have developed a charge-coupled device (CCD) with 5 μm × 45 μm pixels on high-resistivity silicon. The fully depleted 200 μm-thick silicon detector is back-illuminated through a 10 nm-thick in situ doped polysilicon window and is thus highly efficient for soft through > 8 keV hard X-rays. The device described here is a 1.5 megapixel CCD with 2496 × 620 pixels. The pixel and camera geometry was optimized for Resonant Inelastic X-ray Scattering (RIXS) and is particularly advantageous for spectrometers with limited arm lengths. In this article, we describe the device architecture, construction and operation, and its performance during tests at the Advance Light Source (ALS) 8.0.1 RIXS beamline. The improved spectroscopic performance, when compared with a current standard commercial camera, is demonstrated with a ~280 eV (C K ) X-ray beam on a graphite sample. Readout noise is typically 3-6 electrons and the point spread function for soft C K X-rays in the 5 μm direction is 4.0 μm ± 0.2 μm. Finally, the measured quantum efficiency of the CCD is greater than 75% in the range from 200 eV to 1 keV.

36 MATERIALS SCIENCE↗

redMaPPer II: X-ray and SZ performance benchmarks for the SDSS catalog

We evaluate the performance of the Sloan Digital Sky Survey (SDSS) DR8 redMaPPer photometric cluster catalog by comparing it to overlapping X-ray- and Sunyaev-Zeldovich (SZ)-selected catalogs from the literature. We confirm that the redMaPPer photometric redshifts are nearly unbiased ((Δz) ≤ 0.005), have low scatter (σ {sub z} ≈ 0.006-0.02, depending on redshift), and have a low catastrophic failure rate (≈1%). Both the T{sub X} -λ and M {sub gas}-λ scaling relations are consistent with a mass scatter of σ{sub ln} {sub M|λ} ≈ 25%, albeit with a ≈1% outlier rate due to projection effects (λ is the cluster richness estimated employed by redMaPPer). This failure rate is somewhat lower than that expected for the full cluster sample but is consistent with the additional selection effects introduced by our reliance on X-ray and SZ selected reference cluster samples. Where the redMaPPer DR8 catalog is volume-limited (z ≤ 0.35), the catalog is 100% complete above T{sub X} ≳ 3.5 keV, and L{sub X} ≳ 2 × 10{sup 44} erg s{sup –1}, decreasing to 90% completeness at L{sub X} ≈ 10{sup 43} erg s{sup –1}. All rich (λ ≳ 100), low-redshift (z ≲ 0.25) redMaPPer clusters are X-ray-detected in the ROSAT All Sky Survey, and 86% of the clusters are correctly centered. Compared to other SDSS photometric cluster catalogs, redMaPPer has the highest completeness and purity, and the best photometric redshift performance, though some algorithms do achieve comparable performance to redMaPPer in subsets of the above categories and/or in limited redshift ranges. The redMaPPer richness is clearly the one that best correlates with X-ray temperature and gas mass. Most algorithms (including redMaPPer) have very similar centering performance as tested by comparing against X-ray centers, with only one exception which performs worse.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Oil Viscosity and Impact of Ionic Liquid Additive on Electrically Induced Pitting in Rolling Contact

Electrically induced bearing damage (EIBD) is a growing concern in electric drivetrains, where electrical discharge currents generate localized pitting that accelerates wear and premature failure. While ionic liquids (ILs) have shown promise as lubricant additives due to their natural physical adsorption, strong capabilities of tribofilm formation, and high molecular tunability, their role in mitigating EIBD is little known. This gap is especially evident because lubricant viscosity and film thickness affect discharge behavior, and additive performance in these regimes has not been well explored. In this study, tribological tests were performed using a ball-on-disk pure rolling-contact system under an applied voltage on polyalphaolefin oils of three viscosities (4, 10, and 150 cSt measured at 100 °C), with and without the addition of a phosphonium-phosphate IL. Surface damage was analyzed using scanning electron microscopy (SEM) and stylus profilometry. Damage quantification was based on pit morphology analysis of SEM images. The results provide new insights into how oil viscosity governs the discharge behavior and how an IL additive could influence the pit formation. While viscosity seems to play a significant role, an IL additive shows potential to reduce EIBD and deserves further study.

electrically induced bearing damage (EIBD)↗

SU-F-T-169: A Periodic Quality Assurance Program for a Spot-Scanning Proton Treatment Facility

Purpose: To develop daily and monthly quality assurance (QA) programs in support of a new spot-scanning proton treatment facility using a combination of commercial and custom equipment and software. Emphasis was placed on efficiency and evaluation of key quality parameters. Methods: The daily QA program was developed to test output, spot size and position, proton beam energy, and image guidance using the Sun Nuclear Corporation rf-DQA™3 device and Atlas QA software. The program utilizes standard Atlas linear accelerator tests repurposed for proton measurements and a custom jig for indexing the device to the treatment couch. The monthly QA program was designed to test mechanical performance, image quality, radiation quality, isocenter coincidence, and safety features. Many of these tests are similar to linear accelerator QA counterparts, but many require customized test design and equipment. Coincidence of imaging, laser marker, mechanical, and radiation isocenters, for instance, is verified using a custom film-based device devised and manufactured at our facility. Proton spot size and position as a function of energy are verified using a custom spot pattern incident on film and analysis software developed in-house. More details concerning the equipment and software developed for monthly QA are included in the supporting document. Thresholds for daily and monthly tests were established via perturbation analysis, early experience, and/or proton system specifications and associated acceptance test results. Results: The periodic QA program described here has been in effect for approximately 9 months and has proven efficient and sensitive to sub-clinical variations in treatment delivery characteristics. Conclusion: Tools and professional guidelines for periodic proton system QA are not as well developed as their photon and electron counterparts. The program described here efficiently evaluates key quality parameters and, while specific to the needs of our facility, could be readily adapted to other proton centers.

60 APPLIED LIFE SCIENCES↗

SPE5 Sub-Scale Test Series Summary Report

A series of 2 SPE5 sub-scale tests were performed to experimentally confirm that a booster system designed and evaluated in prior tests would properly initiate the PBXN-110 case charge fill. To conduct the experiments, a canister was designed to contain the nominally 50 mm diameter booster tube with an outer fill of approximately 150 mm diameter by 150 mm in length. The canisters were filled with PBXN-110 at NAWS-China Lake and shipped back to LLNL for testing in the High Explosives Applications Facility (HEAF). Piezoelectric crystal pins were placed on the outside of the booster tube before filling, and a series of piezoelectric crystal pins along with Photonic Doppler Velocimetry (PDV) probes were placed on the outer surface of the canister to measure the relative timing and magnitude of the detonation. The 2 piezoelectric crystal pins integral to the booster design were also utilized along with a series of either piezoelectric crystal pins or piezoelectric polymer pads on the top of the canister or outside case that utilized direct contact, gaps, or different thicknesses of RTV cushions to obtain time of arrival data to evaluate the response in preparation for the large-scale SPE5 test. To further quantify the margin of the booster operation, the 1st test (SPE5SS1) was functioned with both detonators and the 2nd test (SPE5SS2) was functioned with only 1 detonator. A full detonation of the material was observed in both experiments as observed by the pin timing and PDV signals. The piezoelectric pads were found to provide a greater measured signal magnitude during the testing with an RTV layer present, and the improved response is due to the larger measurement surface area of the pad. This report will detail the experiment design, canister assembly for filling, final assembly, experiment firing, presentation of the diagnostic results, and a discussion of the results.

36 MATERIALS SCIENCE↗

29 mm Diameter Test Target Design Report

The Northstar target for Mo99 production is made up of Mo100 disks in a stack separated by coolant gaps for helium flow. A number of targets have been tested at ANL for both production of Mo99 and for thermal-hydraulic performance. These have all been with a 12 mm diameter target, even while the production goals have increased the diameter to now 29 mm. A 29 mm diameter target has been designed that is consistent with the ANL beam capabilities and the capabilities of the helium circulation system currently in use at ANL. This target is designed for 500 μA at 35 MeV electrons. While the plant design calls for 42 MeV, the chosen design point is more favorable and higher power given the limits of the ANL accelerator. The intended beam spot size is 12 mm FWHM, but the thermal analysis presented herein conservatively assumed a 10 mm FWHM beam, which results in a 44% higher beam current density at beam center.

43 PARTICLE ACCELERATORS↗

Seismic Testing of Glovebox Feedthrough Connectors and Vacuum Pumps

In the design of tritium processing systems, the glovebox stripper system processes the glovebox atmosphere to recover tritium released inside the glovebox confinement. The glovebox stripper system must also be capable of processing the additional in-leakage caused by a Design Basis Accident (DBA) earthquake, in order to maintain the glovebox pressure negative relative to the room. However, it is unknown how much additional leakage occurs from electrical bulkhead feedthrough connectors after a DBA event. As there are dozens of these connectors on a tritium glovebox system, the potential increase in in-leakage can be significant. One vital part of the glovebox stripper system are the vacuum pumps that maintain the negative atmosphere of the glovebox following a DBA earthquake. The pumps must be able to operate following an earthquake. One candidate pump is the Senior Aerospace MB-602 Metal Bellows (Met-Bel) pump. A second alternative is the hermetically sealed Edwards Vacuum nXDS15iC Scroll Pump. The Edwards scroll pump is potentially a less expensive alternative to the Met-Bel pumps, but it is unknown if this scroll pumps will survive a DBA accident and remain operational. In order to determine the electrical feedthrough in-leakage and the candidate pumps’ survivability, a seismic test was performed to simulate a DBA earthquake. This report summarizes the results of seismic test, including helium leak rates and functionality tests for the electrical feedthroughs and vacuum pumps. All components had pre- and post-test leak rates less than the threshold valve of 1x10 -6 scc per sec.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification Testing of Body Forces due to a Prescribed Angular Velocity in DYNA3D/Paradyn

This report documents the verification testing and regression testing done on a new feature in DYNA3D/Paradyn, which allows users to prescribe body force loads based upon an angular velocity. This feature is unique in that the direction of the angular velocity vector follows the unit vector formed by two coordinate points associated with two nodes or the average coordinates of two separate small collection of nodes. The angular velocity direction will follow the directional vector defined by these nodes while the angular velocity magnitude is defined by a load curve. A simple single element verification test was performed to determine the correct implementation of this feature, and two separate regression tests were added to the DYNA3D Software Quality Assur ance test suite. The nodal positions, velocities, and accelerations from the solution of the single element verification test compare well to analytically derived values of those nodal quantities. The regression tests serve as good examples of this new feature’s use case and were consequently added to the SQA test suite to ensure that further modifications of the DYNA3D source code do not unintentionally change the generated baseline answers.

42 ENGINEERING↗