TRACER-VNATS: Vertically Resolved New Particle Formation and Transport Study Field Campaign Report
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Understanding the world -- This aim drives humankind since the beginning of conscious thinking. Especially the nature of matter has been of major interest. Nowadays, we have a complex image of the constitution of matter. Atoms consist of electrons and nucleons. But even nucleons are not elementary. Their basic constituents are called quarks. Physicists developed a model describing the elementary components of matter as well as the forces between them: the standard model of elementary particle physics. The substructure of matter is only visible in scattering experiments. In high energy physics, these experiments are done at particle accelerators. The world's highest energetic collider, the Tevatron, is hosted by the Fermi National Accelerator Laboratory (FNAL), also called Fermilab, in the vicinity of Chicago. The proton-antiproton collisions with a center-of-mass energy of {radical}s = 1.96 TeV are recorded by two multipurpose detectors, namely D0 and CDF II.
We provide the final report for Csaba Csaki's OJI project on "Physics of extra dimensions". It includes the summary of results of higgsless electroweak symmetry breaking, gauge-higgs unification, AdS/QCD and holographic technicolor, and chiral lattice theories from warped extra dimensions.
The Standard Model of elementary particles can not be the final theory. There are theoretical reasons to expect the appearance of new physics, possibly at the energy scale of few TeV. Several possible theories of new physics have been proposed, each with unknown probability to be confirmed. Instead of arbitrarily choosing to examine one of those theories, this thesis is about searching for any sign of new physics in a model-independent way. This search is performed at the Collider Detector at Fermilab (CDF). The Standard Model prediction is implemented in all final states simultaneously, and an array of statistical probes is employed to search for significant discrepancies between data and prediction. The probes are sensitive to overall population discrepancies, shape disagreements in distributions of kinematic quantities of final particles, excesses of events of large total transverse momentum, and local excesses of data expected from resonances due to new massive particles. The result of this search, first in 1 fb -1 and then in 2 fb -1 , is null, namely no considerable evidence of new physics was found.
We study the behavior of charged particles produced in association with Drell-Yan lepton-pairs in the region of the Z-boson in proton-antiproton collisions at 1.96 TeV. We use the direction of the Z-boson in each event to define 'toward', 'away', and 'transverse' regions. For Drell-Yan production (excluding the leptons) both the 'toward' and 'transverse' regions are very sensitive to the 'underlying event', which is defined as everything except the two hard scattered components. The data are corrected to the particle level and are then compared with several PYTHIA models (with multiple parton interactions) and HERWIG (without multiple parton interactions) at the particle level (i.e. generator level). The data are also compared with a previous analysis on the behavior of the 'underlying event' in high transverse momentum jet production. The goal is to produce data that can be used by the theorists to tune and improve the QCD Monte-Carlo models of the 'underlying event' that are used to simulate hadron-hadron collisions.
It is now accepted that biological effects may occur in cells that were not themselves traversed by ionizing radiation but are close to those that were. Little is known about the mechanism underlying such a bystander effect, although cell-to-cell communication is thought to be important. Previous work demonstrated a significant bystander effect for clonogenic survival and oncogenic transformation in C3H 10T(1/2) cells. Additional studies were undertaken to assess the importance of the degree of cell-to-cell contact at the time of irradiation on the magnitude of this bystander effect by varying the cell density. When 10% of cells were exposed to a range of 2-12 alpha particles, a significantly greater number of cells were inactivated when cells were irradiated at high density than at low density. In addition, the oncogenic transformation frequency was significantly higher in high-density cultures. These results suggest that when a cell is hit by radiation, the transmission of the bystander signal through cell-to-cell contact is an important mediator of the effect, implicating the involvement of intracellular communication through gap junctions. Additional studies to address the relationship between the bystander effect and the adaptive response were undertaken. A novel apparatus, where targeted and non-targeted cells were grown in close proximity, was used to investigate these. It was further examined whether a bystander effect or an adaptive response could be induced by a factor(s) present in the supernatants of cells exposed to a high or low dose of X-rays, respectively. When non-hit cells were co-cultured for 24 h with cells irradiated with 5 Gy alpha-particles, a significant increase in both cell killing and oncogenic transformation frequency was observed. If these cells were treated with 2 cGy X-rays 5 h before co-culture with irradiated cells, approximately 95% of the bystander effect was cancelled out. A 2.5-fold decrease in the oncogenic transformation frequency was also observed. When cells were cultured in medium donated from cells exposed to 5 Gy X-rays, a significant bystander effect was observed for clonogenic survival. When cells were cultured for 5 h with supernatant from donor cells exposed to 2 cGy and were then irradiated with 4 Gy X-rays, they failed to show an increase in survival compared with cells directly irradiated with 4 Gy. However, a twofold reduction in the oncogenic transformation frequency was seen. An adaptive dose of X-rays cancelled out the majority of the bystander effect produced by alpha-particles. For oncogenic transformation, but not cell survival, radioadaption can occur in unirradiated cells via a transmissible factor(s). A pilot study was undertaken to observe the bystander effect in a realistic multicellular three-dimensional morphology. We found bystander responses in a three-dimensional, normal human-tissue system. Endpoints were induction of micronucleated and apoptotic cells. A charged-particle microbeam was used, allowing irradiation of cells in defined locations in the tissue yet guaranteeing that no cells located more than a few micrometers away receive any radiation exposure. Unirradiated cells up to 1 mm distant from irradiated cells showed a significant enhancement in effect over background, with an average increase in effect of 1.7-fold for micronuclei and 2.8-fold for apoptosis. The surprisingly long range of bystander signals in human tissue suggests that bystander responses may be important in extrapolating radiation risk estimates from epidemiologically accessible doses down to very low doses where nonhit bystander cells will predominate. Finally, it would be of great benefit to develop a reproducible tissue system suitable for critical radiobiological assays. We have developed a reliable protocol to harvest cells from tissue samples and to investigate the damage induced on a single cell basis. In order to result in a valid tool for bystander experiments, the method focuses on processing and analyzing radiation damage in individual cells as a function of their relative position in the tissue. We have investigated the micronucleus formation following partial irradiation with 3.5 MeV protons in an artificial human skin construct. Following the optimization of the Cytochalasin-B concentration and incubation time necessary to obtain a reproducible and suitable number of binucleated cells, the induction of micronuclei across the samples is assessed for 3 dose. The reproducible and low background frequency of micronuclei measured in this system allowed us to detect small increases following the irradiation exposure. The effect is statistically significant at doses as low as 0.1 Gy and it shows evidence of a spatial dependency as it decreases in the cells further away from the directly exposed area. This experimental protocol represents the initial steps in the development of an in vivo-like assay for complex radiation damage in human tissues.
The authors present the study of the charm-pair correlations produced in photon-nucleon interactions at $\langle$E γ $\rangle$ = 175 GeV/c, by the Fermilab fixed target experiment E831/FOCUS. The E831/FOCUS experiment produced and reconstructed over one million charm particles. This high statistics allows the reconstruction of more than 7000 charm-pair mesons D$\bar{D}$, 10 times the statistic of former experiments, and also allows to get, for the first time, about 600 totally reconstructed charm-pairs in the DD s and DΛ c channels. They were able to study, with some detail, the kinematical correlations between the charm and anticharm particle forming a pair, in the square transverse momentum (p T 2 ), azimuthal angle difference (ΔΦ), rapidity difference (Δy) and the charm-pair mass variables. They observe some correlation for the longitudinal momenta, and a significant correlation for the transverse momenta of the charm and anticharm particles. They compare the experimental distributions with theoretical predictions based on the photon-gluon fusion model (PGF), for the production of c$\bar{c}$ quarks, and the standard Lund hadronization model. These models are implemented by the PYTHIA Monte Carlo event generator. The PYTHIA program allows the inclusion, in the simulation, of non-perturbative effects that have been shown to be important for charm production. In order to compare data and simulation, they have generated two Monte Carlo samples, the first one set to favor the production of D$\bar{D}$ pairs (MCDD2), and the second one set to favor the production of DD s and DΛ c pairs, where each one uses different functions and parameters values for the theoretical models in the simulation. They observe, for the correlation distributions, that the set of parameters used by the MCDD2 model together with the intrinsic transverse momentum (k $\perp$ ) of the partons inside the nucleons, has a better agreement with data distributions than the one used by the MCDSLC model. Finally, the relative pair/anti-pair yield production ratio is calculated for five sets of charm-pairs, D + D 0 , D + D s - , D 0 D s - , D + Λ c - e D 0 Λ c - , both for data as well as for the two Monte Carlo samples. They observe that the MCDSLC model predicts charm-pair yield production ratios closer to the yield ratios data than the MCDD2 model.
Abstract Not Provided
The single-phase liquid argon prototype at CERN (ProtoDUNE-SP) acts as a validation of the design for the DUNE single-phase far detector. With a total mass of 770 tons, it is the largest monolithic liquid argon single-phase time projection chamber in the world. ProtoDUNE-SP collected test-beam in autumn of 2018 and has been collecting cosmic and special calibration data since the end of 2018.The accumulation of positive ions in a LArTPC located on the surface can distort the electric field and the reconstructed particle trajectories. It is critical to understand and correct for the space charge effects in order to achieve the desired spatial and calorimetric resolutions in the LArTPC. This talk will present the measurement of space charge effects and the calorimetric measurements of the detector in ProtoDUNE-SP.
Electron-hadron colliders are the ultimate tool for high-precision quantum chromodynamics studies and provide the ultimate microscope for probing the internal structure of hadrons. The electron is an ideal probe of the proton structure because it provides the unmatched precision of the electromagnetic interaction, as the virtual photon or vector bosons probe the proton structure in a clean environment, the kinematics of which is uniquely determined by the electron beam and the scattered lepton, or the hadronic final state accounting appropriately for radiation. The Hadron Electron Ring Accelerator HERA (DESY, Hamburg, Germany) was the only electron-hadron collider ever operated (1991–2007) and advanced the knowledge of quantum chromodynamics and the proton structure, with implications for the physics studied in RHIC (BNL, Upton, NY) and the LHC (CERN, Geneva, Switzerland). Recent technological advances in the field of particle accelerators pave the way to realize next-generation electron-hadron colliders that deliver higher luminosity and enable collisions in a much broader range of energies and beam types than HERA. Electron-hadron colliders combine challenges from both electron and hadron machines besides facing their own distinct challenges derived from their intrinsic asymmetry. This review paper will discuss the major features and milestones of HERA and will examine the electron-hadron collider designs of the Electron-Ion Collider (EIC) currently under construction at BNL, the CERN’s Large Hadron electron Collider (LHeC), at an advanced stage of design and awaiting approval, and the Future Circular lepton-hadron Collider (FCC-eh).
Rotating-coil measurement systems are widely used to measure the multipolar fields of particle accelerator magnets. This paper presents a rotating-coil measurement system that aims at providing a complete data set for the characterization of quadrupole magnets with small bore diameters (26 mm). The PCB magnetometer design represents a challenging goal for this type of transducer. It is characterized by an aspect ratio 30% higher than the state of the art, imposed by the reduced dimension of the external radius of the rotating shaft and the necessity of covering the entire magnet effective length (500 mm or higher). The system design required a novel design for the mechanical asset, also considering the innovation represented by the commercial carbon fiber tube, housing the PCB magnetometer. Moreover, the measurement system is based primarily on standard and commercially available components, with simplified control and post-processing software applications. The system and its components are cross-calibrated using a stretched-wire system and another rotating-coil system. The measurement precision is established in a measurement campaign performed on a quadrupole magnet characterized by an inner bore diameter of 45 mm.
Particle gun for detector studies: A particle gun for two pions separated by PI in phi. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in energy from 0 to 150 GeV for each particle. Uniform distribution in Eta between -5 and 5. Uniform distribution in Phi between -PI and PI."
Particle gun for detector studies: A particle gun for two elecrons separated by PI in phi. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in energy from 0 to 150 GeV for each particle. Uniform distribution in Eta between -5 and 5. Uniform distribution in Phi between -PI and PI."
Particle gun for detector studies: A particle gun for two elecrons separated by PI in phi. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in energy from 0 to 150 GeV for each particle. Uniform distribution in Eta between -5 and 5. Uniform distribution in Phi between -PI and PI."
Particle gun for detector studies: A particle gun for two pions separated by 0,1,2,..20 degrees in Phi. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV pion energy (fixed). There are 100 files in each sample.
Particle gun for detector studies: A particle gun for two K-long mesons (KL, PID=130) separated by 0,1,2,..20 degrees in Phi. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV energy (fixed). There are 100 files in each sample.
Particle gun for detector studies: A particle gun for two K-long mesons (KL, PID=130) separated by 0.5 degree. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The maximal separation is 10 degree. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV energy (fixed). There are 100 files in each sample. The sample was designed for detector studies.