Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality, for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other functional requirements specified in ANSI/ANS-8.3.1997, are not included in the test. Routine and periodic maintenance and calibrations performed at Y-12 and AWE are intended to provide adequate confirmation for meeting these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for the Testing of the Y-12 Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor (IER-443)

This report documents the experimental conditions and final results for the performance testing of the Y-12 Criticality Accident Alarm System (CAAS) detectors at the Godiva IV Burst Reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The testing followed a previously issued test plan and was conducted during the week of July 17, 2017, with completion on Thursday July 20. The test subjected CAAS detectors supplied by Y-12 to very intense and short duration mixed neutron and gamma radiation fields to establish compliance to maximum radiation and minimum pulse width requirements. ANSI/ANS- 8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates provided by each burst during the test exceeded those requirements. The CAAS detectors all provided an immediate alarm signal and remained operable after the bursts establishing compliance to the requirements and fitness for re-deployment at Y-12.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2017

The Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) as a result of storm runoff. This activity supports U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM-NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. Air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content are collected at the meteorological station. The maximum, minimum, and average or total values (as appropriate) for each of these parameters are recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrology station are also recorded for every 10-minute interval. This report presents data collected from these stations during fiscal year (FY) 2017.

(CA)↗

Radiation Hard CMOS Sensors for Detector at High Energy Colliders

In this project we developed a radiation hard CMOS sensor architecture for High Energy Colliders. The key accomplishments were: 1. Developed a sensor architecture to support very high occupancy rate and hit rates 2. Developed, simulated (TCAD), and fabricated 20 different types of pixelated test structures for the quadruple well high resistivity substrate process. Measured performance of these pixel test structures; Dark currents were found to be close to physical limits; and Quantum efficiency were found to be close to ideal as well 3. Defined the scope for the PDK for the quadruple well process on high resistivity silicon Highlights of the new architecture are: Readout of pixel arrays with reconstruction efficiency >99% at hit rates of 500 MHits/cm 2 and array occupancy of 0.2%; Minimization of in-pixel signal storage requirement (data will be read out at frame rates of 1MHz); Low power dissipation through integration of fragmented projection architecture (Minimum analog power dissipation); Pixel array level data reduction (Hit location is encoded through shape of sub-block projections); Programmable resolution and frame rate (Pixels can be binned to increase frame rate); Minimum data overhead, encoded projection results for all sub-blocks are read out without location information

43 PARTICLE ACCELERATORS↗

Assessment of the propensity of low creep ductility for optimized Grade 92 steel

A total of twenty-five optimized Grade 92 (Opt.G92) samples were tested at 550, 600, and 650°C in air with stresses ranging from 90 to 280 MPa. Two types of Opt.G92 heats were studied in this work, with one type only fabricated by vacuum induction melting (VIM) and the other type by both VIM and electro-slag remelting (VIM+ESR). All the samples were in the as-received thermomechanical treatment (TMT) condition, except for one sample in the re-normalized and tempered (Re-N&T) condition. Three of the samples are still running, with the longest test time >39,863 h at 550°C. In general, the creep-ruptured samples exhibited consistently superior creep resistance, in terms of longer time to rupture, higher creep strength, and lower minimum creep rate, compared to Grades 92 and 91. For example, Opt.G92 with TMT increased creep strength by ~50 and ~60 MPa with minimum creep rate about two orders of magnitude lower than P92 and P91, respectively, at 550°C. The ongoing test of the Opt.G92 sample in the Re-N&T condition also showed significant enhancement in creep resistance. Although the enhancement in creep resistance of Opt.G92 over P92 and P91 became smaller at higher temperatures, the enhancement is still noticeable at 650°C.

36 MATERIALS SCIENCE↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2018

Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) as a result of storm runoff. This activity supports U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collects air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters are recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station are also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2018. During the FY2018 reporting period, the warmest months were June, July, and August and the coldest were December through March. Solar radiation showed the same seasonal trend. Monthly mean wind speeds were highest in the spring (March through May) and early summer (June). Winds were generally from the west during the summer and from the north throughout the fall and winter. The monthly average relative humidity ranged from the mid-teens to approximately 50 percent. Humidity was lowest in the fall and highest in the winter. Monthly total precipitation ranged from 0 in October, December, and June to approximately 1.38 inches (in) (35.05 millimeters [mm]) in July. Total precipitation for FY2018 was 3.86 in (98.04 mm). During the reporting period, two runoff events were recorded at the flume. One occurred on July 14, 2018, in response to precipitation earlier the same day. This event produced a peak water depth of 11.26 in (28.60 centimeters [cm]) in the flume, which is equivalent to a discharge of 1.86 cubic feet per second (cfs) (0.05 cubic meters per second [cm/s]) and a velocity of 3.97 feet per second (fps) (1.21 meters per second [m/s]) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 1.29 fps (0.39 m/s), which is sufficient to transport silts and fine sands. The second flow event occurred in response to earlier precipitation on September 4, 2018. This event produced a peak water depth of 0.78 in (1.98 cm) in the flume, which is equivalent to a discharge of 0.03 cfs (0.001 cm/s) and a velocity of 1.17 fps (0.36 m/s) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 0.03 fps (0.01 m/s). Although neither runoff event produced sufficient flow velocities through the natural channel to cause local erosion and transport of coarser bedload materials, the velocity of the first runoff event was sufficient to transport silts and fine sands, which have been shown to be preferentially associated with radionuclide contaminants. Therefore, a sampling event was planned after the first flow event in conjunction with a periodic maintenance inspection. As no suspended load sampling is available at this location, bedload samples were collected from the vicinity of the flume on August 7, 2018. The collected sediment was separated into three particle size fractions and each fraction was analyzed for americium-241 (Am-241), plutonium-238 (Pu-238), and plutonium-239/240 (Pu-239/240) by alpha spectrometry. The two smaller particle size fractions had higher concentrations of all three radionuclides than the largest particle size fraction. Additionally, Pu-239/240 had the highest concentration and Pu-238 had the lowest concentration in all samples. The same relationship between the concentrations of Pu-238 and Pu-239/240 was seen in samples reported in FY2013 and FY2014. Observation of meteorological and environmental conditions that lead to storm runoff will help identify parameters and threshold conditions that should be incorporated into postclosure monitoring plans for this and similar sites as well as aid in determining appropriate closure strategies for other Soils CAUs.

54 ENVIRONMENTAL SCIENCES↗

Submersible Blend Pump Mixing Evaluation

Savannah River Remediation (SRR) requested Savannah River National Laboratory (SRNL) to perform an engineering analysis to investigate the mixing behavior in feed blend tanks for the Salt Waste Processing Facility (SWPF). The baseline for mixing the feed blend tanks is a U 0 D of 5.1 ft 2 /s, a pump nozzle elevation of 165.86 inches above the sludge layer and 174 inches above the tank bottom, a liquid level 174.28 inches above the pump nozzle, and a blend time of 10.63 hours. The current Salt Batch Plan identifies Tanks 21, 26, 41, and 42 as the designated blend tanks. This supplemental study only addresses Type IIIA tanks (i.e., Tanks 26, 41, and 42). Using the Tank 41 current configuration as the baseline, the analysis considers the impact on blending if: 1) the distance between the pump discharge nozzle and the liquid surface increases above the baseline, 2) the distance between the pump discharge nozzle and the liquid surface decreases below the baseline, 3) the distance between the pump discharge nozzle and the sludge layer at the bottom of the tank increases above the baseline, or 4) the distance between the pump discharge nozzle and the sludge layer at the bottom of the tank decreases below the baseline, each while maintaining the minimum U 0 D of 5.1 ft 2 /s. Per subsequent direction from SRR, the minimum distance between the pump discharge nozzle and the sludge will be 165.86 inches. Hence, distances less than 165.86 inches between the pump discharge nozzle and the sludge were not included in the analysis. In addition, SRR requested SRNL to evaluate the impact of the abandoned in place, failed slurry pumps in Tank 42 on liquid blending.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction and Parametrization of Isobaric Trinucleon Elastic Cross Sections and Form Factors

By mining data from Jefferson Lab Hall A experiment E08-014 a new 3 He elastic cross section was extracted from a large quasielastic background. This measurement was taken with an initial beam energy of 3.356 GeV and an angle of 20.51°. The cross section was found to be 1.345 × 10 -6 µb/sr ± 0.086 × 10 -6 µb/sr at Q 2 = 34.19 fm -2 . This new data point falls approximately halfway between the first and second diffractive minima of the 3 He form factors. When combined with recent high Q 2 3 He elastic cross section measurements from Jefferson Lab and MIT-Bates this new data point improves our knowledge of the cross section and form factors at large momentum transfers. The new high Q 2 data motivate a reanalysis of the 3 He elastic cross section world data and provide an improved understanding of the magnetic form factor in particular. For this analysis the elastic cross section world data for 3 He, and its mirror nuclei 3 H, were collected. The world data spans a time frame from 1965 to 2016. The dataset contains electron energy ranges from tens of MeV to above 12 GeV for measurements performed at many different facilities. The world data were then fit using a sum of Gaussians parametrization which allowed for the extraction of both targets’ magnetic and electric form factors which were then used to calculate charge densities and radii. The new charge and magnetic form factors for 3 H and the charge form factor for 3 He are in good agreement with the 1994 fits from Amroun et al . However, the addition of the new high Q 2 data has caused the 3 He magnetic form factor’s first diffractive minimum to shift up in Q 2 by 1-3 fm -2 while also decreasing the magnitude of the magnetic form factor above Q2 ≈ 20 fm -2 . The first diffractive minima for 3H are located at Q2 ≈ 13 fm -2 and Q 2 ≈ 23-24 fm -2 for the charge and magnetic form factors respectively. The first diffractive minima for 3 He are located at Q 2 ≈ 11 fm -2 and Q 2 ≈ 17-20 fm -2 for the charge and magnetic form factors respectively. The charge radius for 3 He was found to be 1.90 fm ± 0.00144 fm in reasonable agreement with past measurements, and the charge radius for 3 H was found to be 2.02 fm ± 0.0133 fm which is much larger than past measurements. However, each of these charge radii has an additional uncertainty that must be applied to them due to allowing all parameters to float freely during the sum of Gaussians fitting procedure. This additional uncertainty should be small for 3 He, but it is likely quite significant for 3 H and would help bring this charge radius closer to agreement with past measurements that made different fitting choices. Unfortunately, this analysis was unable to quantify this additional uncertainty. The new form factor fits were compared to modern theoretical predictions from the 2016 paper of Marcucci et al . The ‘conventional’ theoretical approach applied in this paper modelled two and three-body nucleon interactions with relativistic corrections and was reasonably successful at predicting the charge form factors of 3 H and 3 He. χEFT predictions were also often successful. However, while the ‘conventional’ approach still performed best, theory failed to accurately predict the magnetic form factors of either 3 H or 3 He. The first diffractive minimum of the new 3 He magnetic form factor fits actually moved further away from theory. This disagreement between theory and experiment provides motivation for new asymmetry measurements using polarized 3 He and a polarized electron beam. When the beam is scanned in Q 2 on the target the sign of the asymmetry will flip at the form factor minima pinning down their true location.

Barcus, Scott↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 42H

The Savannah River National Laboratory (SRNL) Atmospheric Technologies Group performed atmospheric dispersion modeling and analysis of mercury emissions from the H-Tank Farm - Tank 42 ventilation system exhaust to evaluate potential worker exposures to mercury vapor. This analysis was used to establish a minimum stack height at which ambient mercury concentration would not exceed any worker exposure limit. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. Results indicate that the default 10-foot stack results in ground level concentrations that significantly exceed exposure standards for the mercury discharge scenarios evaluated. For a discharge of 25 mg/m 3 , a 50-foot stack was necessary to raise the exhaust plume centerline from Tank 42H to a height that prevents mercury exposure problems for elevated receptors on buildings near the tank. If the discharge concentration is decreased to 10 mg/m 3 , the minimum stack height required to comply with exposure limits is of 40 feet.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for SDUs

The SRNL Atmospheric Technologies Group performed an analysis to determine the minimum stack height necessary to avoid exceedance of the ACGIH (American Conference of Governmental Industrial Hygienists) 15-minute Short-Term Exposure Limit (STEL) and 8-hour Time Weighted Average (TWA) ambient standards for worst case hazardous chemical emissions from the Z-Area Mega SDUs. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modeling tool for this analysis. Receptors were placed to represent the breathing level concentrations that workers might have, placed 6-ft above the working surface (ground or SDU tank surface). Based on the analysis conducted, the minimum SDU exhaust release height to avoid exceeding STEL and TWA is 6 feet above the SDU roof level for flow rates between 300 and 1200 cfm. The configuration of Mega SDUs, while large structures, do not produce an aerodynamic wake that impacts the stack releases and causes exceedances to the worker exposure limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spark Breakdown Threshold in Non-Uniform Fields

We develop a criterion for spark breakdown in non-uniform field geometries with positive polarity and small electrode separations so that breakdown evolves without the formation of a leader. We arrive at the spark-breakdown criterion by framing it in terms of gain and instability conditions, whose relative importance are established from an analysis of the experimental breakdown characteristics and correlations with streamer behavior in short gaps. Results are presented in the context of two generic geometries having coaxial and point-plane electrodes. For nearly uniform field situations, we re-confirm that the breakdown criterion obtained by the usual extension of either the Townsend or Meek criteria satisfactorily predicts the experimental results. On the other hand, for increasing non-uniformity, the results for the corona and spark branches of the breakdown characteristics are shown inconsistent with a breakdown criterion solely based on either the Townsend or streamer mechanisms. In particular, the avalanche gain factor, the primary component of the Townsend and streamer criteria does not determine the spark breakdown criterion. Streamers can cross the gap for a significantly wide range of applied voltages without triggering a spark. We find that it is the instability condition, derived from a relation between the minimum Laplacian field in the gap and the local streamer body field (which we relate to the streamer sustaining field), that is sufficient for determining the spark threshold thereby yielding a breakdown criterion. We examine the physics of the discharge occurring in the several parts of the nonuniform field gap to elucidate the underpinning of the threshold criterion. These include streamer stability and branching in the stressed electrode region, cathode fall setup near the planar-type electrode, and importantly, the renewed ionization of the discharge resulting from neutral expansion of the gas discharge driven by currents, which are critically dependent on the minimum field level in the gap. We also discuss experiments which were carried out to examine instabilities associated with the streamer breakdown of uniform gaps with triggering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Northstar Mo100 Target Beam Spot Size Sensitivity Study

Northstar Mo100 target for production of the medical isotope Mo99 is particularly sensitive to beam over focusing because of the intended high power density. At 38 MeV and 6.32 mA (240 kW beam power, nominally 160 kW th in the target), small deviation from the nominal 12 mm FWHM beam can significantly increase the target disk temperatures and more importantly the load bearing target window temperature. A rhodotron will be the source of the electron beam to be used in the isotope production. This machine operates in a pulsed beam mode, currently expected to be at 50 Hz, which results in a 100 C temperature oscillation above and below the steady state temperature that is the focus of this study. This must be considered in the determination of minimum beam spot size that can be accepted by the target without risk of failure. In addition to the nominal beam spot size of 12 mm, the analysis of 10, 11 and 14.5 mm beam spot sizes are analyzed. The primary conclusion is that an over focused beam to just 11 mm FWHM is the minimum beam spot allowable, based on window temperature and the Ultimate Tensile Stress (UTS) of the window material Inconel 718 as a function of temperature. In contrast an under focused beam of 14.5 mm FWHM has much reduced target and window temperatures, but there is a resulting 6% drop in isotope production, all other factor staying the same. These results are presented herein.

07 ISOTOPE AND RADIATION SOURCES↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2019

Desert Research Institute (DRI) conducted a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) because of storm runoff. This activity supported U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work was intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collected air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters were recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station were also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2019. During the FY2019 reporting period, the warmest months were June, July, and August and the coldest were December and February. The highest monthly solar radiation (i.e., sunshine) values were recorded in June, July, and August, whereas December through February had the lowest solar radiation values. Monthly mean wind speeds were highest in the spring (April) and early summer (June). Winds were predominantly from the north, except in February, July, August, and September when winds were mostly from the west. The monthly average relative humidity ranged from 17 percent to approximately 60 percent. Humidity was lowest in the summer and highest in the winter. Monthly total precipitation ranged from 0.0 during August and September to 2.22 inches (in) (56.39 millimeters [mm]) in February. Total precipitation for FY2019 was 7.83 in (198.88 mm). During the reporting period, a single, nonzero, flow event was recorded at the flume. This occurred over two days between March 6 and 7, 2019, in response to 1.16 in (29.46 mm) of precipitation falling within 9.3 hours on March 6, 2019. This event produced a peak water depth of 0.39 in (0.99 centimeters [cm]) in the flume, and runoff was measured for approximately 23.5 hours. However, the maximum recorded flow depth was less than the limit for flow discharge and velocity that can be calculated for the six-inch (15 cm) throat of a Parshall flume. The runoff event produced insufficient flow velocities through the natural channel to cause local erosion and transport of bedload materials. No bedload samples were collected for radiological analysis. Observing meteorological and environmental conditions that lead to storm runoff will help identify the parameters and threshold conditions that should be incorporated into post-closure monitoring plans for this and similar Soils CAU sites. Routine monitoring of meteorological and hydrologic parameters at the Smoky Site CA has been discontinued at the request of EM NV, effective at the conclusion of FY2019. Environmental data acquisition was completed and the meteorological and runoff monitoring stations were removed from the Smoky Site on October 15, 2019.

54 ENVIRONMENTAL SCIENCES↗

Fluidization of Group A Glass Particles: Experiments and Preliminary Validation

This work is aimed at providing reliable high-quality data from fluidization experiments. Geldart Group A glass beads are used as bed material. The fluidizing medium is air at atmospheric pressure which enters the system at 40% relative humidity. The air inlet velocity is varied over a broad range from 2 U mf to 26 U mf , where the minimum fluidization velocity, U mf , is 0.608 cm/s. There is not a significant change in the mean values of differential pressure; however, there are noticeable trends in their standard deviation values. Preliminary validation studies are performed using the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). The results from Eulerian-Eulerian (MFiX-TFM, two-fluid model) and Eulerian-Lagrangian (MFiX-PIC, particle-in-cell) formulations are compared. The work presented in this report highlights the applicability of MFiX-PIC for large-scale applications, and reveals that PIC simulation offers a suitable alternative to TFM simulation when effects due to multiple components or polydispersity are significant. PIC modeling provides a readily extendible framework for such systems. However, PIC models do rely on an empirical closure for inter-particle stress. Some solution discrepancies were evident in MFiX-PIC predictions which require further analysis. As such, the study underlines the need for a systematic approach to quantify the sources of numerical uncertainty within the PIC model. However, even with known empiricism, MFiX-PIC has demonstrated considerable potential in analyzing gas-solid systems. The results obtained are encouraging and warrant further investigation to improve the predictive capability of MFiX-PIC.

36 MATERIALS SCIENCE↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Re-Additization of Commercial Biodiesel Blends During Long-Term Storage

Commercial biodiesel blends representative of the U.S. market were aged following procedure ASTM D4625, Standard Test Method for Middle Distillate Fuel Storage Stability at 43°C (110°F), with periodic monitoring of fuel properties indicative of oxidation. The oxidation stability—or oxidation reserve expressed as Rancimat induction period (IP)—gradually decreased from its initial value, as expected. At a predetermined IP threshold, an antioxidant was used to restore IP to the ASTM D7467 specification minimum of 6 six hours, referred to as re-additization. At lower IP values, the amount of antioxidant required increased significantly, and the effectiveness tended to be reduced. Once IP fell to essentially zero, the acid content increased to above the allowable limit. Insoluble material was detectable after the acid number increased out of specification. Storage life was increased with re-additization relative to the as-received fuels, as evidenced by longer time to produce acids. Experience in the field may vary based on storage conditions; however, these results indicate re-additization can significantly increase the storage life of biodiesel blends when used with regular monitoring of IP and acid number. An assessment of property changes during long-term storage showed the initial IP did not predict storage behavior, although fuels above the specification minimum remained stable for greater than 12 weeks of D4625 accelerated aging (1 one year simulated).

09 BIOMASS FUELS↗

Tank 49H Solids Disturbance Analysis

Tank 49H will serve as the feed tank for the Salt Waste Processing Facility (SWPF). Transfers into Tank 49H may disturb solids that have settled to the bottom of the tank, resulting in feed that may exceed the insoluble solids content limit of 1,200 mg/L from the SWPF Waste Acceptance Criteria (WAC). During a transfer into Tank 49H, material that free falls into Tank 49H through a downcomer and passes through the supernate could potentially disturb the solids on the bottom of the tank and scour or suspend solids from a settled solids layer or turbid region. A previous analysis and report evaluated the potential to disturb solids when transferring into Tank 49H through the B4 riser and recommended a minimum tank level of 120 inches to prevent disturbing any solids in the bottom of the tank. The scope of this task is to perform additional fluid flow analysis to determine the impact of a “plunging jet” through the C3 downcomer on solids in Tank 49H and to determine a minimum liquid level to be maintained in Tank 49H prior to transfers that will minimize disturbing the solids and exceeding the SWPF WAC limits for insoluble solids carryover to SWPF since the C3 riser downcomer is at a lower elevation and farther away from the B5 transfer pump than the B4 downcomer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Random Forest Optimization for Radionuclide Identification

Radionuclide identification through gamma-ray spectroscopy is an indispensable tool in combatting the illicit smuggling of nuclear material. The radionuclide identification devices used in the field need to provide ready-made answers to non-experts, and therefore require sophisticated algorithms that can interpret the underlying data. We investigated the Random Forest classifier as a tool for identifying the radionuclide that is consistent with the data. We were provided with training and validations data sets and used them to optimize the two hyperparameters of the classifiers: maximum features required, and minimum samples used to split each node. The F1 score, a harmonic mean of precision and recall, was used to evaluate the performance of each built classifier. We found the optimal performance with minimum samples of 5 and maximum features of 50, with the F1 score of 0.95.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗