Understanding the Effects of Compression and Constraints on Water Uptake of Fuel-Cell Membranes

Accurate characterization of polymer-electrolyte fuel cells (PEFCs) requires understanding the impact of mechanical and electrochemical loads on cell components. An essential aspect of this relationship is the effect of compression on the polymer membrane?s water-uptake behavior and transport properties. However, there is limited information on the impact of physical constraints on membrane properties. In this paper, we investigate both theoretically and experimentally how the water uptake of Nafion membrane changes under external compression loads. The swelling of a compressed membrane is modeled by modifying the swelling pressure in the polymer backbone which relies on the changes in the microscopic volume of the polymer. The model successfully predicts the water content of the compressed membrane measured through in-situ swelling-compression tests and neutron imaging. The results show that external mechanical loads could reduce the water content and conductivity of the membrane, especially at lower temperatures, higher humidities, and in liquid water. The modeling framework and experimental data provide valuable insight for the swelling and conductivity of constrained and compressed membranes, which are of interest in electrochemical devices such as batteries and fuel cells.

36 MATERIALS SCIENCE↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Elevated temperature contact creep and friction of nickel-based superalloys using machine learning assisted finite element analysis

Nickel-based superalloys with superior thermochemical, mechanical, and tribological properties are highly utilized for critical components in several high temperature applications such as gas turbines and nuclear reactors. Inconel 617, in particular, is considered as one of the main candidate superalloys for tribo-components in very-high-temperature gas-cooled nuclear reactors. Recent findings indicate that this alloy grows unique surface oxide especially in a high-temperature helium environment with distinctive wear, friction, and contact properties. Here, this study investigates the high temperature contact area evolution and frictional behavior of Inconel 617 using finite element simulation and provides predictive models for the contact and friction performance at different normal loads, dwell times, and temperatures. High temperature helium-aged Inconel 617 top surface properties (up to 600 °C) are utilized along with a single asperity-based deformable elastic-plastic contact model under combined normal and tangential loading. Machine learning is used to assist the finite element results and to predict friction coefficient as well as contact area evolution. While a small difference is observed in the instantaneous friction coefficient (no dwell time) for all temperatures, friction coefficient increases considerably with dwell time. This shows that the effect of contact creep for longer dwell times significantly dominants the effect of high temperature variation in basic mechanical parameters such as modulus and yield strength. It is found that increasing temperature and dwell times lead to the friction coefficient increase, yet the dominance of dwell time effects decreases at higher temperatures and loads. While the analysis is presented for Inconel 617, the methodology is easy to be generalized and can be applied to other HT alloys.

36 MATERIALS SCIENCE↗

Cross-scale efficient tensor contractions for coupled cluster computations through multiple programming model backends

Coupled-cluster methods provide highly accurate models of molecular structure through explicit numerical calculation of tensors representing the correlation between electrons. These calculations are dominated by a sequence of tensor contractions, motivating the development of numerical libraries for such operations. While based on matrix–matrix multiplication, these libraries are specialized to exploit symmetries in the molecular structure and in electronic interactions, and thus reduce the size of the tensor representation and the complexity of contractions. The resulting algorithms are irregular and their parallelization has been previously achieved via the use of dynamic scheduling or specialized data decompositions. We introduce our efforts to extend the Libtensor framework to work in the distributed memory environment in a scalable and energy-efficient manner. We achieve up to 240× speedup compared with the optimized shared memory implementation of Libtensor. We attain scalability to hundreds of thousands of compute cores on three distributed-memory architectures (Cray XC30 and XC40, and IBM Blue Gene/Q), and on a heterogeneous GPU-CPU system (Cray XK7). As the bottlenecks shift from being compute-bound DGEMM's to communication-bound collectives as the size of the molecular system scales, we adopt two radically different parallelization approaches for handling load-imbalance, tasking and bulk synchronous models. Nevertheless, we preserve a unified interface to both programming models to maintain the productivity of computational quantum chemists.

97 MATHEMATICS AND COMPUTING↗

HANFORD DOUBLE SHELL TANK THERMAL AND SEISMIC PROJECT SUMMARY OF COMBINED THERMAL AND OPERATING LOADS WITH SEISMIC ANALYSIS

This report summarizes the results of the Double-Shell Tank Thermal and Operating Loads Analysis (TaLA) combined with the Seismic Analysis. This combined analysis provides a thorough, defensible, and documented analysis that will become a part of the overall analysis of record for the Hanford double-shell tanks (DSTs). The bases of the analytical work presented herein are two ANSYS{reg_sign} finite element models that were developed to represent a bounding-case tank. The TaLA model includes the effects of temperature on material properties, creep, concrete cracking, and various waste and annulus pressure-loading conditions. The seismic model considers the interaction of the tanks with the surrounding soil including a range of soil properties, and the effects of the waste contents during a seismic event. The structural evaluations completed with the representative tank models do not reveal any structural deficiencies with the integrity of the DSTs. The analyses represent 60 years of use, which extends well beyond the current date. In addition, the temperature loads imposed on the model are significantly more severe than any service to date or proposed for the future. Bounding material properties were also selected to provide the most severe combinations. While the focus of the analyses was a bounding-case tank, it was necessary during various evaluations to conduct tank-specific analyses. The primary tank buckling evaluation was carried out on a tank-specific basis because of the sensitivity to waste height, specific gravity, tank wall thickness, and primary tank vapor space vacuum limit. For this analysis, the occurrence of maximum tank vacuum was classified as a service level C, emergency load condition. The only area of potential concern in the analysis was with the buckling evaluation of the AP tank, which showed the current limit on demand of l2-inch water gauge vacuum to exceed the allowable of 10.4 inches. This determination was based on analysis at the design waste temperature of 350 F and the full 60-year corrosion allowance on the tank wall of 0.060 inch. However, analysis at a more realistic temperature of 250 F or corrosion allowance of 0.025 inch results in an acceptable demand/capacity ratio according to the ASME code criteria. Thus, buckling of the primary tank is judged to be unlikely for the current lack of corrosion in the tanks, and the expectation that the maximum waste temperature will not exceed 210 F. The reinforced concrete structure was evaluated as specified by the American Concrete Institute (ACI) code requirements for nuclear safety-related structures (ACI-349). The demand was demonstrated to be lower than the capacity at all locations. Revision 1 is being issued to document changes to the anchor bolt evaluation. RPP-RPT-32237 Rev. 1, Hanford Double-Shell Tank Thermal and Seismic Project-Increased Liquid Level Analysis for 241AP Tank Farms, described changes to the anchor bolt modeling and evaluation which were implemented in response to the independent reviewer's comments. Similar changes have been made in the bounding tank analysis and are documented in RPP-RPT-28968 Rev. 1. The conclusions of the previous releases of this report remain unchanged.

36 MATERIALS SCIENCE↗

Transformation of char carbon during bubbling fluidized bed gasification of biomass

This study focuses on the fate of carbon in the char generated by devolatilization of biomass during fluidized bed gasification. A carbon balance model was developed to distinguish between char transformed to carbon-bearing gases and its comminution and elutriation as fine char during gasification. The model accurately predicts the transient accumulation of char carbon in the reactor. Experiments revealed steady state reactor char carbon loadings were achieved after multiple hours of gasification. The model formed the basis of an experimental methodology that assesses the transformation of char carbon based on collection of elutriated solids from the reactor and assessment of the steady state char carbon loading in the reactor. Experiments were performed to distinguish the relative contributions of chemical reaction and physical comminution toward conversion of char to gaseous and solid products. The effects of equivalence ratio, gasification temperature, superficial gas velocity, biomass particle size, and the addition of steam on the partitioning of char carbon between gaseous and solid products during gasification of ground seed corn in a bubbling fluidized bed were investigated. This study revealed that char conversion during gasification of biomass was limited by elutriation of fine char particles arising from fragmentation or attrition of primary char product. Additionally, increased chemical reaction of char to form gases was usually accompanied by increased elutriation of fine char, which suggests that chemical reaction increased the porosity of the char and its susceptibility to fragmentation and attrition. Lastly, decreasing superficial gas velocity, increasing equivalence ratio, and decreasing particle size led to increased carbon conversion, while increasing temperature and steam concentration in the reactor had negligible effect.

09 BIOMASS FUELS↗

Smart Data Mapping for Connecting Power System Model and Geospatial Data

Knowing the geospatial locations of power system model elements is the foundation for analyzing system vulnerability to natural hazards and connecting loads with end users and their communities. However, power system models and geospatial data for power grid assets may have been developed asynchronously without close coordination. Creating a direct mapping between the two may be a challenging task, considering heterogeneous data structures, target uses, historical legacies, and human errors. This work aims to build an automatic data mapping workflow to connect power system model elements and geospatial data for transmission network, and to support energy grid resilience studies for Puerto Rico. The primary steps in this workflow include constructing graphs using geospatial data, and aligning them to the transmission networks defined in the power system data. The results have been evaluated against existing manual mapping practices for part of the Puerto Rico Power Grid model to illustrate the performance of such auto-mapping solutions.

Resilience, geospatial data, grid transmission net↗

Applying graph partitioning methods in measurement-based dynamic load balancing

Load imbalance leads to an increasing waste of resources as an application is scaled to more and more processors. Achieving the best parallel efficiency for a program requires optimal load balancing which is a NP-hard problem. However, finding near-optimal solutions to this problem for complex computational science and engineering applications is becoming increasingly important. Charm++, a migratable objects based programming model, provides a measurement-based dynamic load balancing framework. This framework instruments and then migrates over-decomposed objects to balance computational load and communication at runtime. This paper explores the use of graph partitioning algorithms, traditionally used for partitioning physical domains/meshes, for measurement-based dynamic load balancing of parallel applications. In particular, we present repartitioning methods developed in a graph partitioning toolbox called SCOTCH that consider the previous mapping to minimize migration costs. We also discuss a new imbalance reduction algorithm for graphs with irregular load distributions. We compare several load balancing algorithms using microbenchmarks on Intrepid and Ranger and evaluate the effect of communication, number of cores and number of objects on the benefit achieved from load balancing. New algorithms developed in SCOTCH lead to better performance compared to the METIS partitioners for several cases, both in terms of the application execution time and fewer number of objects migrated.

97 MATHEMATICS AND COMPUTING↗

Field Testing of Nano-PCM Enhanced Building Envelope Components

The U.S. Department of Energy's (DOE) Building Technologies Program s goal of developing high-performance, energy efficient buildings will require more cost-effective, durable, energy efficient building envelopes. Forty-eight percent of the residential end-use energy consumption is spent on space heating and air conditioning. Reducing envelope-generated heating and cooling loads through application of phase change material (PCM)-enhanced envelope components can facilitate maximizing the energy efficiency of buildings. Field-testing of prototype envelope components is an important step in estimating their energy benefits. An innovative phase change material (nano-PCM) was developed with PCM encapsulated with expanded graphite (interconnected) nanosheets, which is highly conducive for enhanced thermal storage and energy distribution, and is shape-stable for convenient incorporation into lightweight building components. During 2012, two test walls with cellulose cavity insulation and prototype PCM-enhanced interior wallboards were installed in a natural exposure test (NET) facility at Charleston, SC. The first test wall was divided into four sections, which were separated by wood studs and thin layers of foam insulation. Two sections contained nano-PCM-enhanced wallboards: one was a three-layer structure, in which nano-PCM was sandwiched between two gypsum boards, and the other one had PCM dispersed homogeneously throughout graphite nanosheets-enhanced gypsum board. The second test wall also contained two sections with interior PCM wallboards; one contained nano-PCM dispersed homogeneously in gypsum and the other was gypsum board containing a commercial microencapsulated PCM (MEPCM) for comparison. Each test wall contained a section covered with gypsum board on the interior side, which served as control or a baseline for evaluation of the PCM wallboards. The walls were instrumented with arrays of thermocouples and heat flux transducers. Further, numerical modeling of the walls containing the nano-PCM wallboards were performed to determine their actual impact on wall-generated heating and cooling loads. The models were first validated using field data, and then used to perform annual simulations using Typical Meteorological Year (TMY) weather data. This article presents the measured performance and numerical analysis to evaluate the energy-saving potential of the nano-PCM-enhanced building components.

nano-PCM↗

Development of a health monitoring framework: Application to a supercritical pulverized coal-fired boiler

In this study, this work details the development of a physics-based equipment health monitoring framework for a supercritical boiler, using first-principles models to estimate the remaining useful life (RUL) of its components. The framework accounts for fatigue and creep life consumption, generating spatio-temporal variations in mechanical and thermal stress. Analysis of the stress profile throughout the boiler highlights the finishing superheater inlet steam header as a vulnerable location susceptible to damage from cycling operation. The framework also yields quantified uncertainty in the RUL projection for specific locations, accounting for uncertainties in material properties and boiler operation. Results indicate that operational uncertainties (e.g., seasonal variation and operational strategy) and material properties (e.g., rupture time coefficients, Young’s modulus, yield strength, and coefficient of thermal expansion) significantly impact the RUL of the finishing superheater inlet steam header. Additionally, case studies demonstrate the use of the health monitoring framework as a predictive tool for operational planning under uncertainty, including scenarios with and without updates on the operation of the boiler.

20 FOSSIL-FUELED POWER PLANTS↗

Study of Anisotropic Elastic-Plastic Model Calibration

The purpose of this study was to first assess the sensitivity of the parameters of elasticplastic material models with anisotropic yield to choices in the calibration procedure. Two models were considered: Hill's 1948 and Barlat's Y1d2004-18p. Subsequently, it was shown that calibration choices can have an effect on the values of the stress and strain at the ultimate point in uniaxial specimen responses. Finally, the calibrated Barlat model was able to reasonably reproduce the load-deflection and strain fields of a validation specimen that experienced multiaxial states of stress. Overall, it was found that the Barlat model resulted in a closer fit to the measurements and that the parameters of the calibration procedure should be varied to assess the sensitivity of the results.

36 MATERIALS SCIENCE↗

EGR Control for Emisson Reduction Using Fast Response Sensors - Phase 1A

The overall objective of this project was to develop exhaust gas recirculation (EGR) control strategies using fast-response Particulate Matter (PM) sensors and NOx sensors to improve the quality of particulate and gaseous emissions from diesel engines. This project initially comprised three phases: (1) Phase IA - sensor requirements to meet PM sensor specifications, NOx sensor assessment, and initial model development for EGR control; (2) Phase IB - continue development on PM and NOx sensors, integrate the sensor signals into the control simulations, and finalize model development for control strategies; and (3) Phase II - validation testing of the control strategies. Only Phase 1A was funded by DOE and executed by Honeywell. The major objectives of Phase 1A of the project included: (1) Sensor validation and operation of fast-response PM and NOx sensors; (2) Control system modeling of low-pressure EGR controls, development of control strategies, and initial evaluation of these models and strategies for EGR control in diesel engines; (3) Sensor testing to understand applicability of fast-response PM sensors in determining loading rates of the particle trap; and (4) Model validation and sensor testing under steady-state and transient operational conditions of actual engines. In particular, specific objectives included demonstration of: (1) A PM sensor response time constant (T10 - T90) of better than 100 milliseconds (msec); (2) The ability to detect PM at concentrations from 0.2 to 2 Bosch smoke number (BSN) or equivalent; (3) PM sensor accuracy to within 20% BSN over the entire range of operation; and (4) PM sensor repeatability to within 10% over the PM entire sensor range equivalent to a BSN of 0.2 to 2.

33 ADVANCED PROPULSION SYSTEMS↗

Catalyzing deep decarbonization with federated battery diagnosis and prognosis for better data management in energy storage systems

Industrial data analytics methods play a central role in improving energy storage performance and efficiency, impacting the future of electrified transportation and renewable electricity generation. However, significant challenges hinder the large-scale deployment of batteries. Conventional methods rely on centralized collection and processing of fleet-level data, leading to database size issues and privacy concerns due to potential data breaches. To enable scalable deployment of battery management systems, this article proposes a federated battery diagnosis and prognosis model, which distributes the processing of battery standard current-voltage-time-usage data in a privacy-preserving manner. Instead of transferring the raw data, this approach communicates only the locally processed parameters, thus reducing communication load and preserving data confidentiality. The federated model offers a paradigm shift in battery health management through privacy-preserving distributed methods for battery data processing and lifetime prediction, ensuring the reliable and sustainable deployment of lithium-ion batteries in a rapidly evolving world.

asset health management↗

Synergies Between Building-Sited Batteries and Thermal Energy Storage

As renewable penetration increases, there is a greater need for energy storage systems located at buildings. This storage can include batteries, which directly shift the metered load, or thermal energy storage, which shifts thermal-driven electric loads like air conditioning. This presentation covers modeling results of the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. It also shows how battery storage can expand the usefulness of thermal energy storage for electric load shaving, and how thermal storage can lower the cost of the overall storage system and extend battery lifetime by reducing cycling.

batteries↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

A Novel Method for Controlling Crud Deposition in Nuclear Reactors Using Optimization Algorithms and Deep Neural Network Based Surrogate Models

This work presents the use of a high-fidelity neural network surrogate model within a Modular Optimization Framework for treatment of crud deposition as a constraint within light-water reactor core loading pattern optimization. The neural network was utilized for the treatment of crud constraints within the context of an advanced genetic algorithm applied to the core design problem. This proof-of-concept study shows that loading pattern optimization aided by a neural network surrogate model can optimize the manner in which crud distributes within a nuclear reactor without impacting operational parameters such as enrichment or cycle length. Several analysis methods were investigated. Analysis found that the surrogate model and genetic algorithm successfully minimized the deviation from a uniform crud distribution against a population of solutions from a reference optimization in which the crud distribution was not optimized. Strong evidence is presented that shows boron deposition in crud can be optimized through the loading pattern. This proof-of-concept study shows that the methods employed provide a powerful tool for mitigating the effects of crud deposition in nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Disturbance accommodating control design for wind turbines using solvability conditions

In this study, solvability conditions for disturbance accommodating control (DAC) have been discussed and applied on wind turbine controller design in above-rated wind speed to regulate rotor speed and to mitigate turbine structural loads. DAC incorporates a predetermined waveform model and uses it as part of the state-space formulation, which is known as the internal model principle to reduce or minimize the wind disturbance effects on the outputs of the wind turbine. An asymptotically stabilizing DAC controller with disturbance impact on the wind turbine being totally canceled out can be found if certain conditions are fulfilled. Designing a rotor speed regulation controller without steady-state error is important for applying linear control methodology such as DAC on wind turbines. Therefore, solvability conditions of DAC without steady-state error are attractive and can be taken as examples when designing a multitask turbine controller. DAC controllers solved via Moore-Penrose Pseudoinverse and the Kronecker product are discussed, and solvability conditions of using them are given. Additionally, a new solvability condition based on inverting the feed-through D term is proposed for the sake of reducing computational burden in the Kronecker product. Applications of designing collective pitch and independent pitch controllers based on DAC are presented. Recommendations of designing a DAC-based wind turbine controller are given. A DAC controller motivated by the proposed solvability condition that utilizes the inverse of feed-through D term is developed to mitigate the blade flapwise once-per-revolution bending moment together with a standard proportional integral controller in the control loop to assist rotor speed regulation. Simulation studies verify the discussed solvability conditions of DAC and show the effectiveness of the proposed DAC control design methodology.

17 WIND ENERGY↗

Calculating frequency at loads in simulations of electro-mechanical transients

This paper introduces a new method for calculating frequency at an electrical load in simulations of electro-mechanical transients. The method is designed for simulation studies that require accurate models of sensors such as phasor measurement units and F-Net devices, which measure frequency at locations away from generating plants. These sensors are poised to become critical components in the control systems of electrical power grids, and therefore simulation tools that incorporate accurate models of these devices are essential. The method proposed here corrects two drawbacks of using numerically computed phase angle derivatives to approximate frequency. First, it eliminates spurious spikes in frequencies calculated at loads. Second, it eliminates instabilities induced by the simulator in studies of frequency responsive loads. The proposed method is derived from a simplified model of the generators and loads in an electrical system, but in the final analysis does not depend critically on these simplifications and is therefore applicable to more sophisticated models. The method is demonstrated with the simplified model applied to the IEEE 14 and 300 bus systems.