Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Design optimization of MR-compatible rotating anode x-ray tubes for stable operation

Purpose: Hybrid x-ray/MR systems can enhance the diagnosis and treatment of endovascular, cardiac, and neurologic disorders by using the complementary advantages of both modalities for image guidance during interventional procedures. Conventional rotating anode x-ray tubes fail near an MR imaging system, since MR fringe fields create eddy currents in the metal rotor which cause a reduction in the rotation speed of the x-ray tube motor. A new x-ray tube motor prototype has been designed and built to be operated close to a magnet. To ensure the stability and safety of the motor operation, dynamic characteristics must be analyzed to identify possible modes of mechanical failure. In this study a 3D finite element method (FEM) model was developed in order to explore possible modifications, and to optimize the motor design. The FEM provides a valuable tool that permits testing and evaluation using numerical simulation instead of building multiple prototypes.Methods: Two experimental approaches were used to measure resonance characteristics: the first obtained the angular speed curves of the x-ray tube motor employing an angle encoder; the second measured the power spectrum using a spectrum analyzer, in which the large amplitude of peaks indicates large vibrations. An estimate of the bearing stiffness is required to generate an accurate FEM model of motor operation. This stiffness depends on both the bearing geometry and adjacent structures (e.g., the number of balls, clearances, preload, etc.) in an assembly, and is therefore unknown. This parameter was set by matching the FEM results to measurements carried out with the anode attached to the motor, and verified by comparing FEM predictions and measurements with the anode removed. The validated FEM model was then used to sweep through design parameters [bearing stiffness (1×10{sup 5}–5×10{sup 7} N/m), shaft diameter (0.372–0.625 in.), rotor diameter (2.4–2.9 in.), and total length of motor (5.66–7.36 in.)] to increase the fundamental frequency past the operating range at 50 Hz.Results: The first large vibration during the prototype motor operation was obtained at 21.64±0.68 Hz in the power spectrum. An abrupt decrease in acceleration occurred at 21.5 Hz due to struggling against the resonance vibrations. A bearing stiffness of 1.2×10{sup 5} N/m in the FEM simulation was used to obtain a critical speed of 21.4 Hz providing 1.1% error. This bearing stiffness value and the 3D model were then confirmed by the experiments with the anode removed, demonstrating an agreement within 6.4% between simulation results and measurements. A calculated first critical frequency (fundamental frequency) of 68.5 Hz was obtained by increasing the bearing stiffness to 1×10{sup 7} N/m and increasing the shaft diameter by 68.0%. Reducing the number of bearings in the design permits decreasing the total length of the motor by 1.7 in., and results in a fundamental frequency of 68.3 Hz in concert with additional changes (shaft diameter of 0.625 in., rotor diameter of 2.4 in., and bearing stiffness of 1×10{sup 6} N/m).Conclusions: An FEM model of the x-ray tube motor has been implemented and experimentally validated. A fundamental frequency above the operational rotation speed can be achieved through modification of multiple design parameters, which allows the motor to operate stably and safely in the MR environment during the repeated acceleration/deceleration cycles required for an interventional procedure. The validated 3D FEM model can now be used to investigate trade-offs between generated torque, maximum speed, and motor inertia to further optimize motor design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced phase contrast transfer using ptychography combined with a pre-specimen phase plate in a scanning transmission electron microscope

We report the ability to image light elements in both crystalline and noncrystalline materials at near atomic resolution with an enhanced contrast is highly advantageous to understand the structure and properties of a wide range of beam sensitive materials including biological specimens and molecular hetero-structures. This requires the imaging system to have an efficient phase contrast transfer at both low and high spatial frequencies. Here, we introduce a new phase contrast imaging method in a scanning transmission electron microscope (STEM) using a pre-specimen phase plate in the probe forming aperture, combined with a fast pixelated detector to record diffraction patterns at every probe position, and phase reconstruction using ptychography. The phase plate significantly enhances the contrast transfer of low spatial frequency information, and ptychography maximizes the extraction of the phase information at all spatial frequencies. In addition, the STEM probe with the presence of the phase plate retains its atomic resolution, allowing simultaneous incoherent Z-contrast imaging to be obtained along with the ptychographic phase image. An experimental image of Au nanoparticles on a carbon support shows high contrast for both materials. Multislice image simulations of a DNA molecule shows the capability of imaging soft matter at low dose conditions, which implies potential applications of low dose imaging of a wide range of beam sensitive materials.

36 MATERIALS SCIENCE↗

Thermal imaging of plasma with a phased array antenna in QUEST

A thermal imaging system to measure plasma Electron Bernstein Emission (EBE) emanating from the mode conversion region in overdense plasma is discussed. Unlike conventional ECE/EBE imaging, this diagnostics does not employ any active mechanical scanning mirrors or focusing optics to scan for the emission cones in plasma. Instead, a standard 3 × 3 waveguide array antenna is used as a passive receiver to collect emission from plasma and imaging reconstruction is done by accurate measurements of phase and intensity of these signals by heterodyne detection technique. A broadband noise source simulating the EBE, is installed near the expected mode conversion region and its position is successfully reconstructed using phase array technique which is done in post processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full-waveform inversion and least-squares reverse-time migration imaging of collimated ultrasonic-beam data for high-resolution wellbore integrity monitoring

Los Alamos National Laboratory (LANL) has recently developed an ultrasonic side-lobe suppressed Bessel collimated beam transducer for low-frequency imaging through highly attenuating materials. In this paper, we study the effectiveness of using such a collimated ultrasonic-beam transducer for imaging concrete heterogeneities outside borehole casing for high-resolution borehole imaging and wellbore integrity monitoring. We obtain detailed concrete heterogeneities including a low-velocity zone using ultrasound data acquired with a 3D imaging prototype and our recently developed full-waveform inversion and least-squares reverse-time migration methods. Full-waveform inversion fits synthetic ultrasonic waveforms with recorded waveforms to build a high-resolution velocity model. Least-squares reverse-time migration produces a high-resolution structural image showing material discontinuities. Finally, our results demonstrate that LANL's 3D imaging system with a collimated ultrasonic-beam transducer together with full-waveform inversion and least-squares reverse-time migration imaging has great potential for high-resolution single-well borehole imaging and non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Far-field thermal imaging below diffraction limit

Non-uniform self-heating and temperature hotspots are major concerns compromising the performance and reliability of submicron electronic and optoelectronic devices. At deep submicron scales where effects such as contact-related artifacts and diffraction limits accurate measurements of temperature hotspots, non-contact thermal characterization can be extremely valuable. In this work, we use a Bayesian optimization framework with generalized Gaussian Markov random field (GGMRF) prior model to obtain accurate full-field temperature distribution of self-heated metal interconnects from their thermoreflectance thermal images (TRI) with spatial resolution 2.5 times below Rayleigh limit for 530nm illumination. Finite element simulations along with TRI experimental data were used to characterize the point spread function of the optical imaging system. In addition, unlike iterative reconstruction algorithms that use ad hoc regularization parameters in their prior models to obtain the best quality image, we used numerical experiments and finite element modeling to estimate the regularization parameter for solving a real experimental inverse problem.

42 ENGINEERING↗

Evaluation of the MSFC facsimile camera system as a tool for extraterrestrial geologic exploration

Utility of the Marshall Space Flight (MSFC) facsimile camera system for extraterrestrial geologic exploration was investigated during the spring of 1971 near Merriam Crater in northern Arizona. Although the system with its present hard-wired recorder operates erratically, the imagery showed that the camera could be developed as a prime imaging tool for automated missions. Its utility would be enhanced by development of computer techniques that utilize digital camera output for construction of topographic maps, and it needs increased resolution for examining near field details. A supplementary imaging system may be necessary for hand specimen examination at low magnification.

Wolfe, E. W.↗

Transmitter/receiver for laser imaging

Dual-mirror transmitter and receiver combination is used with laser multispectral imaging system carried by low fly aircraft. Device can be arranged to reduce laser light backscatter which creates false light levels in recorded image and compensates for scanning phase delay between transmitter and receiver.

Hasell, P. G., Jr.↗

Method of remotely characterizing thermal properties of a sample

A sample in a wind tunnel is radiated from a thermal energy source outside of the wind tunnel. A thermal imager system, also located outside of the wind tunnel, reads surface radiations from the sample as a function of time. The produced thermal images are characteristic of the heat transferred from the sample to the flow across the sample. In turn, the measured rates of heat loss of the sample are characteristic of the flow and the sample.

Heyman, Joseph S.↗

Monitoring Forest Regrowth Using a Multi-Platform Time Series

Over the past 50 years, the forests of western Washington and Oregon have been extensively harvested for timber. This has resulted in a heterogeneous mosaic of remaining mature forests, clear-cuts, new plantations, and second-growth stands that now occur in areas that formerly were dominated by extensive old-growth forests and younger forests resulting from fire disturbance. Traditionally, determination of seral stage and stand condition have been made using aerial photography and spot field observations, a methodology that is not only time- and resource-intensive, but falls short of providing current information on a regional scale. These limitations may be solved, in part, through the use of multispectral images which can cover large areas at spatial resolutions in the order of tens of meters. The use of multiple images comprising a time series potentially can be used to monitor land use (e.g. cutting and replanting), and to observe natural processes such as regeneration, maturation and phenologic change. These processes are more likely to be spectrally observed in a time series composed of images taken during different seasons over a long period of time. Therefore, for many areas, it may be necessary to use a variety of images taken with different imaging systems. A common framework for interpretation is needed that reduces topographic, atmospheric, instrumental, effects as well as differences in lighting geometry between images. The present state of remote-sensing technology in general use does not realize the full potential of the multispectral data in areas of high topographic relief. For example, the primary method for analyzing images of forested landscapes in the Northwest has been with statistical classifiers (e.g. parallelepiped, nearest-neighbor, maximum likelihood, etc.), often applied to uncalibrated multispectral data. Although this approach has produced useful information from individual images in some areas, landcover classes defined by these techniques typically are not consistent for the same scene imaged under different illumination conditions, especially in the mountainous regions. In addition, it is difficult to correct for atmospheric and instrumental differences between multiple scenes in a time series. In this paper, we present an approach for monitoring forest cutting/regrowth in a semi-mountainous portion of the southern Gifford Pinchot National Forest using a multisensor-time series composed of MSS, TM, and AVIRIS images.

Sabol, Donald E., Jr.↗

Image Acquisition in Real Time

In 1995, Carlos Jorquera left NASA s Jet Propulsion Laboratory (JPL) to focus on erasing the growing void between high-performance cameras and the requisite software to capture and process the resulting digital images. Since his departure from NASA, Jorquera s efforts have not only satisfied the private industry's cravings for faster, more flexible, and more favorable software applications, but have blossomed into a successful entrepreneurship that is making its mark with improvements in fields such as medicine, weather forecasting, and X-ray inspection. Formerly a JPL engineer who constructed imaging systems for spacecraft and ground-based astronomy projects, Jorquera is the founder and president of the three-person firm, Boulder Imaging Inc., based in Louisville, Colorado. Joining Jorquera to round out the Boulder Imaging staff are Chief Operations Engineer Susan Downey, who also gained experience at JPL working on space-bound projects including Galileo and the Hubble Space Telescope, and Vice President of Engineering and Machine Vision Specialist Jie Zhu Kulbida, who has extensive industrial and research and development experience within the private sector.

Source record↗

Imaging of Protein Crystals with Two-Photon Microscopy

Second-order nonlinear optical imaging of chiral crystals (SONICC), which portrays second-harmonic generation (SHG) by noncentrosymmetric crystals, is emerging as a powerful imaging technique for protein crystals in media opaque to visible light because of its high signal-to-noise ratio. Here we report the incorporation of both SONICC and two-photon excited fluorescence (TPEF) into one imaging system that allows visualization of crystals as small as 10 {mu}m in their longest dimension. Using this system, we then documented an inverse correlation between the level of symmetry in examined crystals and the intensity of their SHG. Moreover, because of blue-green TPEF exhibited by most tested protein crystals, we also could identify and image SHG-silent protein crystals. Our experimental data suggest that the TPEF in protein crystals is mainly caused by the oxidation of tryptophan residues. Additionally, we found that unspecific fluorescent dyes are able to bind to lysozyme crystals and enhance their detection by TPEF. We finally confirmed that the observed fluorescence was generated by a two-photon rather than a three-photon process. The capability for imaging small protein crystals in turbid or opaque media with nondamaging infrared light in a single system makes the combination of SHG and intrinsic visible TPEF a powerful tool for nondestructive protein crystal identification and characterization during crystallization trials.

59 BASIC BIOLOGICAL SCIENCES↗

Adaptive temperature profile control of a multizone crystal growth furnace

An intelligent measurement system is described which is used to assess the shape of a crystal while it is growing inside a multizone transparent furnace. A color video imaging system observes the crystal in real time, and determines the position and the shape of the interface. This information is used to evaluate the crystal growth rate, and to analyze the effects of translational velocity and temperature profiles on the shape of the interface. Creation of this knowledge base is the first step to incorporate image processing into furnace control.

Batur, C.↗

System for Photogrammetry, Imaging, Detection, and Ranging, Software Design

Kennedy Space Center (KSC) uses high level pan/tilt camera systems in order to capture data for image analysis. As of right now, we know that current camera systems need to be man-operated, range greatly in costs, and are supplied by third parties. This project, System for Photogrammetric Imaging, Detection, and Ranging, otherwise known as SPIDR, aims to provide high quality image analysis from data drawn from the pan/tilt camera system to upgrade KSC’s ability to take images, and improve space flight and tracking. What this abstract will do, is explain the software needed to carry out such important tasks.

R.S. Kim↗

FOCAL PLANE WAVEFRONT SENSING USING RESIDUAL ADAPTIVE OPTICS SPECKLES

Optical imperfections, misalignments, aberrations, and even dust can significantly limit sensitivity in high-contrast imaging systems such as coronagraphs. An upstream deformable mirror (DM) in the pupil can be used to correct or compensate for these flaws, either to enhance the Strehl ratio or suppress the residual coronagraphic halo. Measurement of the phase and amplitude of the starlight halo at the science camera is essential for determining the DM shape that compensates for any non-common-path (NCP) wavefront errors. Using DM displacement ripples to create a series of probe and anti-halo speckles in the focal plane has been proposed for space-based coronagraphs and successfully demonstrated in the lab. We present the theory and first on-sky demonstration of a technique to measure the complex halo using the rapidly changing residual atmospheric speckles at the 6.5 m MMT telescope using the Clio mid-IR camera. The AO system's wavefront sensor measurements are used to estimate the residual wavefront, allowing us to approximately compute the rapidly evolving phase and amplitude of speckle halo. When combined with relatively short, synchronized science camera images, the complex speckle estimates can be used to interferometrically analyze the images, leading to an estimate of the static diffraction halo with NCP effects included. In an operational system, this information could be collected continuously and used to iteratively correct quasi-static NCP errors or suppress imperfect coronagraphic halos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Viper Science Operations: Science Traverse Planning Perspectives, Processes, and Tools.

Introduction: The NASA Volatiles Investigating Polar Exploration Rover (VIPER) launchesin late 2024 towards a landing site on Mons Mouton in the Nobile region of the Lunar South Pole (LSP). As described in other LPSC presentations [1,2,3], the primary objective of the VIPER mission is to study the composition and distribution of hydrogen-bearing and other volatiles by way of a complementary suite of payloads that the rover will carry to the Moon: three “prospecting” instruments which operate continuously while roving - the Neutron Spectrometer System (NSS), the Near InfraRed Volatiles Spectrometer System (NIRVSS), and the Mass Spectrometer observing lunar operations (MSolo). A 1-meter auguring/percussive drill called the The Regolith and Ice Drill for Exploration of New Terrains (TRIDENT) is used to bring subsurface cuttings to the surface in 10-cm increments where they are interrogated by NIRVSS and MSolo. The Visible Imaging System is comprised of eight cameras (the NavCam stereo pair mounted on the mast gimbal, the AftCam stereo pair mounted on the aft panel, and four HazCams mounted in the wheel wells) that capture grayscale visible wavelength images of the lunar environment and the rover’s upper deck. The VIPER mobility system is a four-wheel design that includes the following motorized modules: Suspension, Steering, and Drive/Propulsion. Wheel odometry and applied torque — combined with position data from rover imagery — can be used to compute assessments of ‘slip and sinkage’. Slope estimates can be computed from stereo rover imagery, as well as pitch and roll data from the IMU (Inertial Measurement Unit) and Star Tracker telemetry.

Darlene Sze Shien Lim↗

Scatter Signal Elimination by Localized Primary Modulation in Industrial Computed Radiography

In industrial computed radiography, same as the other projection imaging systems, quantitative integrated information of total beam path including the object is carried by primary part of the beam. It is well known that the accuracy of the image useful data carried by the primary part degrades by scattered part of the beam. In order to have the beam path quantitative information accurately, it is essential to obtain the primary part of the total signal purely. In current study, a practical approach using localized primary modulation has been proposed to extract the primary signal. A semi-transparent beam attenuation grid was used as the beam intensity modulator. Efficiency and accuracy of the approach was practically validated through thickness measurement of metallic planar steps as an illustrative example. Simplified practical implementation and availability of the required accessories are some of advantages of the proposed approach. The results are indicative of the fact that this approach can also be applied as a new technique in thickness measurement, yielding a noticeable accuracy improvement in the most radiography methods. A procedure is included to explain the approach implementation for thickness measurement in computed radiography systems. The procedure overcomes some practical limitations and difficulties of the approach adaptation for computed radiography.

42 ENGINEERING↗

Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detector materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam hardening effect. Conclusions: The results showed that a CT system using an energy resolving detector reduces the dose to the patient while maintaining image quality for various breast imaging tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An image-based technique to assess the perceptual quality of clinical chest radiographs

Purpose: Current clinical image quality assessment techniques mainly analyze image quality for the imaging system in terms of factors such as the capture system modulation transfer function, noise power spectrum, detective quantum efficiency, and the exposure technique. While these elements form the basic underlying components of image quality, when assessing a clinical image, radiologists seldom refer to these factors, but rather examine several specific regions of the displayed patient images, further impacted by a particular image processing method applied, to see whether the image is suitable for diagnosis. In this paper, the authors developed a novel strategy to simulate radiologists' perceptual evaluation process on actual clinical chest images. Methods: Ten regional based perceptual attributes of chest radiographs were determined through an observer study. Those included lung grey level, lung detail, lung noise, rib-lung contrast, rib sharpness, mediastinum detail, mediastinum noise, mediastinum alignment, subdiaphragm-lung contrast, and subdiaphragm area. Each attribute was characterized in terms of a physical quantity measured from the image algorithmically using an automated process. A pilot observer study was performed on 333 digital chest radiographs, which included 179 PA images with 10:1 ratio grids (set 1) and 154 AP images without grids (set 2), to ascertain the correlation between image perceptual attributes and physical quantitative measurements. To determine the acceptable range of each perceptual attribute, a preliminary quality consistency range was defined based on the preferred 80% of images in set 1. Mean value difference ({mu}{sub 1}-{mu}{sub 2}) and variance ratio ({sigma}{sub 1}{sup 2}/{sigma}{sub 2}{sup 2}) were investigated to further quantify the differences between the selected two image sets. Results: The pilot observer study demonstrated that our regional based physical quantity metrics of chest radiographs correlated very well with their corresponding perceptual attributes. The distribution comparisons, mean value difference estimations, and variance ratio estimations of each physical quantity between sets of images from two different techniques matched our expectation that the image quality of set 1 should be better than that of set 2. Conclusions: The measured physical quantities provide a robust reflection of perceptual image quality in clinical images. The methodology can be readily applied for automated evaluation of perceptual image quality in clinical chest radiographs.

60 APPLIED LIFE SCIENCES↗