Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Correlative Electron and Fluorescence Microscopy of Magnetotactic Bacteria in Liquid: Toward In Vivo Imaging

Magnetotactic bacteria biomineralize ordered chains of uniform, membrane-bound magnetite or greigite nanocrystals that exhibit nearly perfect crystal structures and species-specific morphologies. Transmission electron microscopy (TEM) is a critical technique for providing information regarding the organization of cellular and magnetite structures in these microorganisms. However, conventional TEM can only be used to image air-dried or vitrified bacteria removed from their natural environment. Here we present a correlative scanning TEM (STEM) and fluorescence microscopy technique for imaging viable cells of Magnetospirillum magneticum strain AMB-1 in liquid using an in situ fluid cell TEM holder. Fluorescently labeled cells were immobilized on microchip window surfaces and visualized in a fluid cell with STEM, followed by correlative fluorescence imaging to verify their membrane integrity. Notably, the post-STEM fluorescence imaging indicated that the bacterial cell wall membrane did not sustain radiation damage during STEM imaging at low electron dose conditions. We investigated the effects of radiation damage and sample preparation on the bacteria viability and found that approximately 50% of the bacterial membranes remained intact after an hour in the fluid cell, decreasing to ~30% after two hours. These results represent a first step toward in vivo studies of magnetite biomineralization in magnetotactic bacteria.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Results of Ultrasonography-Guided Percutaneous Radiofrequency Ablation in Hyperparathyroid Patients in Whom Surgery Is Not Feasible

BackgroundThe aim of the study was to evaluate the results of ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) in hyperparathyroid patients who refused surgery or had high surgical risks.Patients and MethodsFive patients with hyperparathyroidism (HPT) underwent US-guided RFA for a single hyperfunctioning parathyroid lesion. Post-ablation serum calcium and parathormone (PTH) assays were performed. All patients underwent imaging studies 6 months after the ablation to visualize the post-ablation change in the size of the treated parathyroid lesions.ResultsAll patients were normocalcemic on the post-ablation 1st day and 6th month. The post-ablation PTH levels were normal in three patients but remained elevated in two patients. The size of the parathyroid lesion was ≥30 mm in the two patients with elevated PTH, whereas the lesion was smaller than 30 mm in those with normal post-ablation PTH values.ConclusionAlthough this is a limited case series, it demonstrates the potential feasibility of RFA for HPT. Benefits were achieved particularly in patients with small parathyroid lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relation between quantitative coronary CTA and myocardial ischemia by adenosine stress myocardial CT perfusion

Background: Coronary-computed tomography angiography (CTA) has limited accuracy to predict myocardial ischemia. Besides luminal area stenosis, other coronary plaque morphology and composition parameters may help to assess ischemia. With the integration of coronary CTA and adenosine stress CT myocardial perfusion (CTP), reliable information regarding coronary anatomy and function can be derived in one procedure. This analysis aimed to investigate the association between coronary stenosis severity, plaque composition and morphology and the presence of ischemia measured with adenosine stress myocardial CTP. Methods and Results: 84 patients (age, 62 ± 10 years; 48% men) who underwent sequential coronary CTA and adenosine stress myocardial CT perfusion were analyzed. Automated quantification was performed in all coronary lesions (quantitative CTA). Downstream myocardial ischemia was assessed by visual analysis of the rest and stress CTP images and defined as a summed difference score of ≥1. One or more coronary plaques were present in 146 coronary arteries of which 31 (21%) were ischemia-related. Of the lesions with a stenosis percentage <50%, 50%-70%, and >70%, respectively, 9% (6/67), 18% (9/51), and 57% (16/28) demonstrated downstream ischemia. Furthermore, mean plaque burden, plaque volume, lesion length, maximal plaque thickness, and dense calcium volume were significantly higher in ischemia-related lesions, but only stenosis severity (%) (OR 1.06; 95% CI 1.02-1.10; P = .006) and lesion length (mm) (OR 1.26; 95% CI 1.02-1.55; P = .029) were independent correlates. Conclusions: Increasing stenosis percentage by quantitative CTA is positively correlated to myocardial ischemia measured with adenosine stress myocardial CTP. However, stenosis percentage remains a moderate determinant. Lumen area stenosis and lesion length were independently associated with ischemia, adjusted for coronary plaque volume, mean plaque burden, maximal lesion thickness, and dense calcium volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualization and analysis of lipopolysaccharide distribution in binary phospholipid bilayers

Lipopolysaccharide (LPS) is an endotoxin released from the outer membrane of Gram-negative bacteria during infections. It have been reported that LPS may play a role in the outer membrane of bacteria similar to that of cholesterol in eukaryotic plasma membranes. In this article we compare the effect of introducing LPS or cholesterol in liposomes made of dipalmitoylphosphatidylcholine/dioleoylphosphatidylcholine on the solubilization process by Triton X-100. The results show that liposomes containing LPS or cholesterol are more resistant to solubilization by Triton X-100 than the binary phospholipid mixtures at 4 {sup o}C. The LPS distribution was analyzed on GUVs of DPPC:DOPC using FITC-LPS. Solid and liquid-crystalline domains were visualized labeling the GUVs with LAURDAN and GP images were acquired using a two-photon microscope. The images show a selective distribution of LPS in gel domains. Our results support the hypothesis that LPS could aggregate and concentrate selectively in biological membranes providing a mechanism to bring together several components of the LPS-sensing machinery.

60 APPLIED LIFE SCIENCES↗

Positional Reproducibility of Pancreatic Tumors Under End-Exhalation Breath-Hold Conditions Using a Visual Feedback Technique

Purpose: To assess positional reproducibility of pancreatic tumors under end-exhalation (EE) breath-hold (BH) conditions with a visual feedback technique based on computed tomography (CT) images. Methods and Materials: Ten patients with pancreatic cancer were enrolled in an institutional review board-approved trial. All patients were placed in a supine position on an individualized vacuum pillow with both arms raised. At the time of CT scan, they held their breath at EE with the aid of video goggles displaying their abdominal displacement. Each three-consecutive helical CT data set was acquired four times (sessions 1-4; session 1 corresponded to the time of CT simulation). The point of interest within or in proximity to a gross tumor volume was defined based on certain structural features. The positional variations in point of interest and margin size required to cover positional variations were assessed. Results: The means {+-} standard deviations (SDs) of intrafraction positional variations were 0.0 {+-} 1.1, 0.1 {+-} 1.2, and 0.1 {+-} 1.0 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively (p = 0.726). The means {+-} SDs of interfraction positional variations were 0.3 {+-} 2.0, 0.8 {+-} 1.8, and 0.3 {+-} 1.8 mm in the LR, AP, and SI directions, respectively (p = 0.533). Population-based margin sizes required to cover 95th percentiles of the overall positional variations were 4.7, 5.3, and 4.9 mm in the LR, AP, and SI directions, respectively. Conclusions: A margin size of 5 mm was needed to cover the 95th percentiles of the overall positional variations under EE-BH conditions, using this noninvasive approach to motion management for pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid characterization and failure analysis of 6276 rooftop-harvested photovoltaic connectors

Photovoltaic (PV) connectors, which link modules in series and connect PV strings in parallel, have increasingly been recognized as a primary contributor to PV system failures and a source of numerous fire incidents. However, publicly available data on the rates and types of connector failures are scarce, primarily due to the proprietary nature of the information and the need for comprehensive analysis. This study represents the first large-scale investigation of harvested PV connectors, drawing from a dataset of 6276 connectors from residential rooftop solar systems across the United States. The outcome of this work is twofold: 1) we have established a rapid characterization method for large populations of harvested connectors, incorporating visual inspection, resistance measurements, and X-ray imaging; and 2) the analysis made possible by our rapid-processing method has revealed, for a population of connector models provided by a single rooftop installer, failure statistics and insights for various connector makes and models, installation practices, operating currents, and internal component displacements. This research identifies common failure modes that could be considered in future connector designs standards, and operations and maintenance practices, to ultimately improve the reliability of this vital component of PV infrastructure.

MC4↗

Direct Visualization of Drug–Polymer Phase Separation in Ritonavir–Copovidone Amorphous Solid Dispersions Using in situ Synchrotron X-ray Fluorescence Imaging of Thin Films

Amorphous solid dispersions (ASDs) are new formulations currently being used in pharmaceutical industry. The ASDs, in which amorphous drug and polymeric excipients are intimately mixed at a molecular level, exhibit dramatically enhanced solubility and dissolution characteristics relative to their crystalline drug counterparts. In the process of achieving an ever-increasing drug loading (DL), it is noticed however, that the drug release profile deteriorates significantly beyond a certain DL. As an example, a ritonavir-copovidone ASD achieves continuous and full drug release when DL ≤ 25 wt%. The release drops at 30 wt% and when DL > 30 wt% there is virtually no drug release, behaving like a pure amorphous drug. In this communication, the dissolution behavior of ASD thin films has been investigated by in situ synchrotron X-ray fluorescence (XRF) imaging to elucidate the mechanism for the unique change in extent of drug release as a function of DL. It is found that the drug release profile correlates well with the amorphous-amorphous phase separation (AAPS) onset. At a lower drug loading (up to 20 wt%), it takes more than 12 hours for AAPS to happen while in sharp contrast, it only needs less than 10 minutes for DL > 30 wt%. During AAPS amorphous drug accumulates on the surface of the film which prevents further dissolution from the interior of the ASD. The current study provides a mechanistic understanding of the confounding drug release profile of ASDs as a function of DL, and opens the door for studying drug-excipient (e.g. polymer, surfactant) interactions via XRF imaging in the future.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Atomic dynamics of gas-dependent oxide reducibility

Understanding oxide reduction is critical for advancing metal production, catalysis and energy technologies. Although carbon monoxide (CO) and hydrogen (H 2 ) are widely used reductants, the mechanisms by which they work are often presumed to be similar, both involving lattice oxygen removal. However, because of growing interest in replacing CO with H 2 to lower CO 2 emissions, distinguishing gas-specific reduction pathways is critical. Yet, capturing these atomic-scale processes under reactive gas and high-temperature conditions remains challenging. Here we use environmental transmission electron microscopy, which is capable of real-time, atomic-resolution imaging of gas–solid redox reactions to directly visualize the gas-dependent oxide reduction dynamics in NiO. We show that CO drives surface nucleation and the growth of metallic Ni islands, leading to self-limiting surface metallization. Conversely, H 2 activates a coupled surface-to-bulk transformation, where protons from dissociated H 2 infiltrate the oxide lattice to promote the inward migration of surface-generated oxygen vacancies and enabling bulk metallization. By contrast, oxygen vacancies formed by CO remain confined near the surface, where they rapidly form a metallic Ni layer that inhibits further reduction. Furthermore, these results reveal distinct atomistic pathways for CO and H 2 and provide insights that may guide metallurgical processes and catalyst design.

36 MATERIALS SCIENCE↗

Fast and accurate view classification of echocardiograms using deep learning

Echocardiography is essential to cardiology. However, the need for human interpretation has limited echocardiography’s full potential for precision medicine. Deep learning is an emerging tool for analyzing images but has not yet been widely applied to echocardiograms, partly due to their complex multi-view format. The essential first step toward comprehensive computer-assisted echocardiographic interpretation is determining whether computers can learn to recognize these views. We trained a convolutional neural network to simultaneously classify 15 standard views (12 video, 3 still), based on labeled still images and videos from 267 transthoracic echocardiograms that captured a range of real-world clinical variation. Our model classified among 12 video views with 97.8% overall test accuracy without overfitting. Even on single low-resolution images, accuracy among 15 views was 91.7% vs. 70.2–84.0% for board-certified echocardiographers. Data visualization experiments showed that the model recognizes similarities among related views and classifies using clinically relevant image features. Our results provide a foundation for artificial intelligence-assisted echocardiographic interpretation.

Madani, Ali↗

A simple method for the analysis of neutron resonance capture spectra

Neutron resonance capture analysis (NRCA) is a method used to determine the bulk composition of various kinds of objects and materials. It is based on analyzing direct capture resonance peaks. However, the analysis is complicated by scattering followed by capture effects in the object itself. These effects depend on the object's shape and size. In this paper the new Delft elemental analysis program (DEAP) is presented which can automatically and quickly analyze multiple NRCA spectra in a practical and simple way, yielding the elemental bulk composition of an object, largely independent of its shape and size. The DEAP method is demonstrated with data obtained with a Roman bronze water tap excavated in Nijmegen (The Netherlands). DEAP will also be used in the framework of the Ancient Charm project as data analysis program for neutron resonance capture imaging (NRCI) experiments. NRCI provides three-dimensional visualization and quantification of the internal structure of archaeological objects by performing scanning measurements with narrowly collimated neutron beams on archaeological objects in computed tomography based experimental setups. The large amounts (hundreds to thousands) of spectra produced during a NRCI experiment can automatically and quickly be analyzed by DEAP.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The catalog of edge-on disk galaxies from SDSS. I. The catalog and the structural parameters of stellar disks

We present a catalog of true edge-on disk galaxies automatically selected from the Seventh Data Release of the Sloan Digital Sky Survey (SDSS). A visual inspection of the g, r, and i images of about 15,000 galaxies allowed us to split the initial sample of edge-on galaxy candidates into 4768 (31.8% of the initial sample) genuine edge-on galaxies, 8350 (55.7%) non-edge-on galaxies, and 1865 (12.5%) edge-on galaxies not suitable for simple automatic analysis because these objects either show signs of interaction and warps, or nearby bright stars project on it. We added more candidate galaxies from RFGC, EFIGI, RC3, and Galaxy Zoo catalogs found in the SDSS footprints. Our final sample consists of 5747 genuine edge-on galaxies. We estimate the structural parameters of the stellar disks (the stellar disk thickness, radial scale length, and central surface brightness) in the galaxies by analyzing photometric profiles in each of the g, r, and i images. We also perform simplified three-dimensional modeling of the light distribution in the stellar disks of edge-on galaxies from our sample. Our large sample is intended to be used for studying scaling relations in the stellar disks and bulges and for estimating parameters of the thick disks in different types of galaxies via the image stacking. In this paper, we present the sample selection procedure and general description of the sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Cannibalization and rebirth in the NGC 5387 system. I. The stellar stream and star-forming region

We have identified a low surface brightness stellar stream from visual inspection of Sloan Digital Sky Survey (SDSS) imaging for the edge-on, spiral galaxy NGC 5387. An optically blue overdensity coincident with the stream intersection with the NGC 5387 disk was also identified in SDSS and in the Galaxy Evolution Explorer Deep Imaging Survey contributing 38% of the total far-UV integrated flux from NGC 5387. Deeper optical imaging was acquired with the Vatican Advanced Technology Telescope that confirmed the presence of both features. The stellar stream is red in color, (B – V) = 0.7, has a stellar mass of 6 × 10{sup 8} M{sub ☉}, which implies a 1:50 merger ratio, has a circular radius, R{sub circ} ∼ 11.7 kpc, formed in ∼240 Myr, and the progenitor had a total mass of ∼4 × 10{sup 10} M{sub ☉}. Spectroscopy from LBT+MODS1 was used to determine that the blue overdensity is at the same redshift as NGC 5387, consists of young stellar populations (∼10 Myr), is metal-poor (12 + log (O/H) = 8.03), and is forming stars at an enhanced rate (∼1-3 M{sub ☉} yr{sup –1}). The most likely interpretations are that the blue overdensity is (1) a region of enhanced star formation in the outer disk of NGC 5387 induced by the minor accretion event or (2) the progenitor of the stellar stream experiencing enhanced star formation. Additional exploration of these scenarios is presented in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Property Variations in Modern REBCO Coated Conductors from Multiple Manufacturers

The complex, multilayer structure of REBCO Coated Conductor (CC) poses significant challenges in the fabrication of high magnetic field devices where large stresses may initiate various forms of damage. Our goal is to peer below the cartoon representations of CC so that, amongst other things, we might better understand whether a CC from one manufacturer is interchangeable with that from another. This involves knowledge of a broad range of electromagnetic, geometric, microstructural, and J c (θ,B,T) properties, and their variations that collectively pose challenges for the fault tolerance of REBCO CC devices. Accordingly, comparative measurements of J c , visualization of flux penetration with Magneto-Optical Imaging (MOI), tape geometry from Scanning Electron Microscopy (SEM) of polished cross-sections, and extensive optical microscopy was performed on recently purchased samples from multiple manufacturers. Our analyses reveal many deviations from or characteristics absent from manufacturers’ specifications, while a comparison of different manufacturers’ mechanically and laser slit tapes shows a diverse array of slitting characteristics amongst the manufacturers and variation in properties those made to the same specification. Laser slit tapes from several manufacturers reveal ablated edges with damaged regions extending up to 50 μm, comparable to the damaged region found in the mechanically slit CC of this study. Overall, the aim of this study is to flesh out appropriate ways to understand the real conductor below the manufacturers’ cartoons to avoid surprises in our REBCO CC coil development program. The goal of this work was to perform a broad array of characterizations of the type needed for validation of purpose for making high field magnets: to our surprise we found a wide range of properties which greatly impact the mechanical strength and electromagnetic performance of solenoids composed of these conductors and reinforced the need for a broad characterization program for each conductor prior to its implementation.

Bradford, G.↗

VANO: a volume-object image annotation system

Volume-object annotation system (VANO) is a cross-platform image annotation system that enables one to conveniently visualize and annotate 3D volume objects including nuclei and cells. An application of VANO typically starts with an initial collection of objects produced by a segmentation computation. The objects can then be labeled, categorized, deleted, added, split, merged and redefined. VANO has been used to build high-resolution digital atlases of the nuclei of Caenorhabditis elegans at the L1 stage and the nuclei of Drosophila melanogaster’s ventral nerve cord at the late embryonic stage.

59 BASIC BIOLOGICAL SCIENCES↗

Type Ia supernovae in the star formation deserts of spiral host galaxies

ABSTRACT Using a sample of nearby spiral galaxies hosting 185 supernovae (SNe) Ia, we perform a comparative analysis of the locations and light-curve decline rates (Δm15) of normal and peculiar SNe Ia in the star formation deserts (SFDs) and beyond. To accomplish this, we present a simple visual classification approach based on the UV/H α images of the discs of host galaxies. We demonstrate that, from the perspective of the dynamical time-scale of the SFD, where the star formation is suppressed by the bar evolution, the Δm15 of SN Ia and progenitor age can be related. The SFD phenomenon gives an excellent possibility to separate a subpopulation of SN Ia progenitors with ages older than a few Gyr. We show, for the first time, that the SFDs contain mostly faster declining SNe Ia (Δm15 > 1.25). For the galaxies without SFDs, the region within the bar radius, and outer disc contain mostly slower declining SNe Ia. To better constrain the delay times of SNe Ia, we encourage new studies (e.g. integral field observations) using the SFD phenomenon on larger and more robust datasets of SNe Ia and their host galaxies.

Hakobyan, A. A. (ORCID:0000000173921765)↗

3D reconstruction of magnetization from dichroic soft X-ray transmission tomography

The development of magnetic nanostructures for applications in spintronics requires methods capable of visualizing their magnetization. Soft X-ray magnetic imaging combined with circular magnetic dichroism allows nanostructures up to 100–300 nm in thickness to be probed with resolutions of 20–40 nm. Here a new iterative tomographic reconstruction method to extract the three-dimensional magnetization configuration from tomographic projections is presented. The vector field is reconstructed by using a modified algebraic reconstruction approach based on solving a set of linear equations in an iterative manner. In conclusion, the application of this method is illustrated with two examples (magnetic nano-disc and micro-square heterostructure) along with comparison of error in reconstructions, and convergence of the algorithm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-JeP2-12: Quantification of 3D Geometric Distortion for 1.5T and 3T MRI Scanners Used for Radiation Therapy

Purpose: To quantify the magnitude of geometric distortion for MRI scanners and provide recommendations for MRI imaging for radiation therapy Methods: A novel phantom, QUASAR MRID3D [Modus Medical Devices Inc.], was scanned to evaluate the level of 3D geometric distortion present in five MRI scanners used for radiation therapy in our department. The phantom was scanned using the body coil with 1mm image slice thickness to acquire 3D images of the phantom body. The phantom was aligned to its geometric center for each scan, and the field of view was set to visualize the entire phantom. The dependence of distortion magnitude with distance from imaging isocenter and with magnetic field strength (1.5T and 3T) was investigated. Additionally, the characteristics of distortion for Siemens and GE machines were compared. The image distortion for each scanner was quantified in terms of mean, standard deviation (STD), maximum distortion, and skewness. Results: The 3T and 1.5T scans show a similar absolute distortion with a mean of 1.38mm (0.33mm STD) for 3T and 1.39mm (0.34mm STD) for 1.5T for a 100mm radius distance from isocenter. Some machines can have a distortion larger than 10mm at a distance of 200mm from the isocenter. The distortions are presented with plots of the x, y, and z directional components. Conclusion: The results indicate that quantification of MRI image distortion is crucial in radiation oncology for target and organ delineation and treatment planning. The magnitude of geometric distortion determines the margin needed for target contouring which is usually neglected in treatment planning process, especially for SRS/SBRT treatments. Understanding the 3D distribution of the MRI image distortion will improve the accuracy of target delineation and, hence, treatment efficacy. MRI imaging with proper patient alignment to the isocenter is vital to reducing the effects of MRI distortion in treatment planning.

60 APPLIED LIFE SCIENCES↗