Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Planck 2013 results. IX. HFI spectral response

The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (includingthe level of out-of-band signal rejection) of all HFI detectors to a known source of electromagnetic radiation individually. This was determined by measuring the interferometric output of a continuously scanned Fourier transform spectrometer with all HFI detectors. As there is no on-board spectrometer within HFI, the ground-based spectral response experiments provide the definitive data set for the relative spectral calibration of the HFI. Knowledge of the relative variations in the spectral response between HFI detectors allows for a more thorough analysis of the HFI data. The spectral response of the HFI is used in Planck data analysis and component separation, this includes extraction of CO emission observed within Planck bands, dust emission, Sunyaev-Zeldovich sources, and intensity to polarization leakage. The HFI spectral response data have also been used to provide unit conversion and colour correction analysis tools. While previous papers describe the pre-flight experiments conducted on the Planck HFI, this paper focusses on the analysis of the pre-flight spectral response measurements and the derivation of data products, e.g. band-average spectra, unit conversion coefficients, and colour correction coefficients, all with related uncertainties. Verifications of the HFI spectral response data are provided through comparisons with photometric HFI flight data. This validation includes use of HFI zodiacal emission observations to demonstrate out-of-band spectral signal rejection better than 10 8 . The accuracy of the HFI relative spectral response data is verified through comparison with complementary flight-data based unit conversion coefficients and colour correction coefficients. Furthermore, these coefficients include those based upon HFI observations of CO, dust, and Sunyaev-Zeldovich emission. General agreement is observed between the ground-based spectral characterization of HFI and corresponding in-flight observations, within the quoted uncertainty of each; explanations are provided for any discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2013 results. II. Low Frequency Instrument data processing

We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44, and 70 GHz. In particular, we discuss the various steps involved in reducing the data, from telemetry packets through to the production of cleaned, calibrated timelines and calibrated frequency maps. Data are continuously calibrated using the modulation induced on the mean temperature of the cosmic microwave background radiation by the proper motion of the spacecraft. Sky signals other than the dipole are removed by an iterative procedure based on simultaneous fitting of calibration parameters and sky maps. Noise properties are estimated from time-ordered data after the sky signal has been removed, using a generalized least squares map-making algorithm. A destriping code (Madam) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices, required to compute statistical uncertainties on LFI and Planck products, are also produced. Main beams are estimated down to the ≈-20 dB level using Jupiter transits, which are also used for the geometrical calibration of the focal plane.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2013 results. XXXI. Consistency of the Planck data

The Planck design and scanning strategy displays many levels of redundancy that can be exploited to provide tests of internal consistency. One of the most important is the comparison of the 70 GHz (amplifier) and 100 GHz (bolometer) channels. Based on different instrument technologies, with feeds located differently in the focal plane, analysed independently by different teams using different software, and near the minimum of diffuse foreground emission, these channels are in effect two different experiments. The 143 GHz channel has the lowest noise level on Planck , and is near the minimum of unresolved foreground emission. In this paper, we analyse the level of consistency achieved in the 2013 Planck data. We concentrate on comparisons between the 70, 100, and 143 GHz channel maps and power spectra, particularly over the angular scales of the first and second acoustic peaks, on maps masked for diffuse Galactic emission and for strong unresolved sources. Difference maps covering angular scales from 8° to 15' are consistent with noise, and show no evidence of cosmic microwave background structure. Including small but important corrections for unresolved-source residuals, we demonstrate agreement (measured by deviation of the ratio from unity) between 70 and 100 GHz power spectra averaged over 70 ≤ ℓ ≤390 at the 0.8% level, and agreement between 143 and 100 GHz power spectra of 0.4% over the same ℓ range. These values are within and consistent with the overall uncertainties in calibration given in the Planck 2013 results. We also present results based on the 2013 likelihood analysis showing consistency at the 0.35% between the 100, 143, and 217 GHz power spectra. We analyse calibration procedures and beams to determine what fraction of these differences can be accounted for by known approximations or systematic errors that could be controlled even better in the future, reducing uncertainties still further. Several possible small improvements are described. Subsequent analysis of the beams quantifies the importance of asymmetry in the near sidelobes, which was not fully accounted for initially, affecting the 70/100 ratio. Correcting for this, the 70, 100, and 143 GHz power spectra agree to 0.4% over the first two acoustic peaks. The likelihood analysis that produced the 2013 cosmological parameters incorporated uncertainties larger than this. We show explicitly that correction of the missing near sidelobe power in the HFI channels would conclude in shifts in the posterior distributions of parameters of less than 0.3σ except for A s , the amplitude of the primordial curvature perturbations at 0.05 Mpc -1 , which changes by about 1σ. We extend these comparisons to include the sky maps from the complete nine-year mission of the Wilkinson Microwave Anisotropy Probe (WMAP), and find a roughly 2% difference between the Planck and WMAP power spectra in the region of the first acoustic peak.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYONDPLANCK VI. Noise characterization and modeling

We present a Bayesian method for estimating instrumental noise parameters and propagating noise uncertainties within the global BeyondPlanck Gibbs sampling framework, and apply this to Planck Low Frequency Instrument (LFI) time-ordered data. Following previous literature, we initially adopt a 1/ f model for the noise power spectral density (PSD), but find the need for an additional lognormal component in the noise model for the 30 and 44 GHz bands. We implement an optimal Wiener-filter (or constrained realization) gap-filling procedure to account for masked data. We then use this procedure to both estimate the gapless correlated noise in the time-domain, n corr , and to sample the noise PSD parameters, ξ n = {σ 0 , f knee , α, A p }. In contrast to previous Planck analyses, we assume piecewise stationary noise only within each pointing period (PID), not throughout the full mission, but we adopt the LFI Data Processing Center (DPC) results as priors on α and f knee . On average, we find best-fit correlated noise parameters that are mostly consistent with previous results, with a few notable exceptions. However, a detailed inspection of the time-dependent results reveals many important findings. First and foremost, we find strong evidence for statistically significant temporal variations in all noise PSD parameters, many of which are directly correlated with satellite housekeeping data. Second, while the simple 1/ f model appears to be an excellent fit for the LFI 70 GHz channel, there is evidence for additional correlated noise not described by a 1/ f model in the 30 and 44 GHz channels, including within the primary science frequency range of 0.1–1 Hz. In general, most 30 and 44 GHz channels exhibit deviations from 1/ f at the 2–3σ level in each one hour pointing period, motivating the addition of the lognormal noise component for these bands. For some periods of time, we also find evidence of strong common mode noise fluctuations across the entire focal plane. Overall, we conclude that a simple 1/ f profile is not adequate to fully characterize the Planck LFI noise, even when fitted hour-by-hour, and a more general model is required. These findings have important implications for large-scale CMB polarization reconstruction with the Planck LFI data, and the current work is a first attempt at understanding and mitigating these issues.

79 ASTRONOMY AND ASTROPHYSICS↗

Tensor-to-scalar ratio forecasts for extended LiteBIRD frequency configurations

LiteBIRD is a planned JAXA-led cosmic microwave background (CMB) B-mode satellite experiment aiming for launch in the late 2020s, with a primary goal of detecting the imprint of primordial inflationary gravitational waves. Its current baseline focal-plane configuration includes 15 frequency bands between 40 and 402 GHz, fulfilling the mission requirements to detect the amplitude of gravitational waves with the total uncertainty on the tensor-to-scalar ratio, δr, down to δr < 0.001. A key aspect of this performance is accurate astrophysical component separation, and the ability to remove polarized thermal dust emission is particularly important. In this paper we note that the CMB frequency spectrum falls off nearly exponentially above 300 GHz relative to the thermal dust spectral energy distribution, and a relatively minor high frequency extension can therefore result in even lower uncertainties and better model reconstructions. Specifically, we compared the baseline design with five extended configurations, while varying the underlying dust modeling, in each of which the High-Frequency Telescope (HFT) frequency range was shifted logarithmically toward higher frequencies, with an upper cutoff ranging between 400 and 600 GHz. In each case, we measured the tensor-to-scalar ratio r uncertainty and bias using both parametric and minimum-variance component-separation algorithms. When the thermal dust sky model includes a spatially varying spectral index and temperature, we find that the statistical uncertainty on r after foreground cleaning may be reduced by as much as 30–50% by extending the upper limit of the frequency range from 400 to 600 GHz, with most of the improvement already gained at 500 GHz. We also note that a broader frequency range leads to higher residuals when fitting an incorrect dust model, but also it is easier to discriminate between models through higher χ 2 sensitivity. Even in the case in which the fitting procedure does not correspond to the underlying dust model in the sky, and when the highest frequency data cannot be modeled with sufficient fidelity and must be excluded from the analysis, the uncertainty on r increases by only about 5% for a 500 GHz configuration compared to the baseline.

79 ASTRONOMY AND ASTROPHYSICS↗

The Proton Form Factor Ratio Measurements at Jefferson Lab

The ratio of the proton form factors, G{sub Ep}/G{sub Mp}, has been measured from Q{sup 2} of 0.5 GeV{sup 2} to 8.5 GeV{sup 2}, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The discovery that the proton form factor ratio measured in these experiments decreases approximately linearly with four-momentum transfer, Q{sup 2}, for values above ~1 GeV{sup 2}, is one of the most significant results to come out of JLab. These results have had a large impact on progress in hadronic physics; and have required a significant rethinking of nucleon structure. The increasingly common use of the double-polarization technique to measure the nucleon form factors, in the last 15 years, has resulted in a dramatic improvement of the quality of all four nucleon electromagnetic form factors, G{sub Ep}, G{sub Mp}, G{sub En} and G{sub Mn}. There is an approved experiment at JLab, GEP(V), to continue the ratio measurements to 12 GeV{sup 2}. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary results of the ion extraction simulations applied to the MONO1000 and SUPERSHyPIE electron cyclotron resonance ion sources

The goal of this article is to present simulations on the extraction from an electron cyclotron resonance ion source (ECRIS). The aim of this work is to find out an extraction system, which allows one to reduce the emittances and to increase the current of the extracted ion beam at the focal point of the analyzing dipole. But first, we should locate the correct software which is able to reproduce the specific physics of an ion beam. To perform the simulations, the following softwares have been tested: SIMION 3D, AXCEL, CPO 3D, and especially, for the magnetic field calculation, MATHEMATICA coupled with the RADIA module. Emittance calculations have been done with two types of ECRIS: one with a hexapole and one without a hexapole, and the difference will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Isochoric heating in heterogeneous solid targets with ultrashort laser pulses

We study ultrafast heating of thin plastic foils by intense laser irradiation theoretically using collisional two-dimensional particle-in-cell simulations. We find that the laser-generated hot electrons are confined laterally by self-generated resistive magnetic fields, heating the laser focal area beyond keV electron temperatures isochorically in a few picoseconds. Using this confinement one can excite shock waves that compress the plasma beyond solid density and achieve keV thermal plasmas before the plasma disassembles. Such shocks can be launched at material interfaces inside the target where jumps in the average ionization state and thus electron density lead to gigabar pressure. They propagate stably over picoseconds accompanied by multi-megagauss magnetic fields, and thus have a potential for various applications in high energy density physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A beam transport system for an intense He{sup -} beam source

We have been developing a test stand for fast He{sup 0} beam production. One of the major issues is how to transport effectively the He{sup +} and He{sup -} beams from which the He{sup 0} beam is produced. The beam should be focused in two transverse focal points, the center of the charge exchange cell and the electrostatic accelerator. We studied the beam transport system and effect of space charge neutralization in the test stand by experiments and calculation.

43 PARTICLE ACCELERATORS↗

Prospects of ion beam extraction and transport simulations (invited)

Beam profile measurements using viewing targets and emittance measurements with pepper pot devices have established new insights about the ion beam extracted from an electron cyclotron resonance ion source (ECRIS). In our measurements we have compared two different ECRISs of CAPRICE type, one source was equipped with a standard 1.0 T hexapole magnet, whereas for the other ion source a stronger hexapole magnet with a flux density of 1.2 T has been installed. The resulting ion beam profile for each individual charge state produced by different focal strengths of an optical element can be used to estimate the emittance, but it also shows the negative influence of the hexapole on the extracted ion beam. A hexapole correction would be desirable to improve further beam transport. A possible correction scheme will be discussed. All experimental observations can be reproduced by computer simulation if a magnetic plasma is assumed. When the Larmor radius for ions becomes small, collisions are negligible for the path of ions within the plasma. Low energy electrons are highly movable along the magnetic field lines and can compensate the ion space charge within the plasma chamber.

43 PARTICLE ACCELERATORS↗

Evidence for enhanced collectivity in Te-I-Xe nuclei near the N = Z = 50 double shell closure

Gamma-ray transitions have been identified for the first time in the extremely neutron-deficient T{sub z} = 1 nuclide {sup 110}Xe and the energies of the three lowest excited states in the ground-state band have been deduced. A level scheme has also been constructed for the proton-unbound, T{sub z} = 3/2 nuclide {sup 109}I, exhibiting band structures built on g{sub 7/2} and h{sub 11/2} states in a weakly deformed, triaxial nucleus. In addition, a third band is proposed to be built on a g{sub 7/2} orbital coupled to an octupole-vibrational phonon of the {sup 108}Te core. The results were obtained in a recoil-decay tagging experiment using the {sup 58}Ni({sup 54}Fe,2n/p2n) reaction at a beam energy of 195 MeV. The experiment was performed using the highly efficient JUROGAM {gamma}-ray spectrometer in conjunction with the RITU gas-filled recoil separator and the GREAT focal-plane spectrometer. The results on {sup 110}Xe establish a breaking of the normal trend of increasing first excited 2{sup +} and 4{sup +} level energies as a function of decreasing neutron number as the N = 50 major shell gap is approached for the neutron-deficient Xe isotopes. This unusual feature is suggested to be an effect of enhanced collectivity, possibly arising from isoscalar n-p interactions becoming increasingly important close to the N = Z line. Features in the low-lying levels of {sup 106}Te and {sup 109}I, showing similar trends, are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of the proton emitting nucleus {sup 159}Re

The observation of the new nuclide {sup 159}Re provides important insights into the evolution of single-particle structure in heavy nuclei beyond the proton drip line. The nuclide {sup 159}Re was synthesised in the reaction {sup 106}Cd({sup 58}Ni,p4n) and identified via its proton radioactivity using the RITU gas-filled separator and the GREAT focal-plane spectrometer. Comparisons of the measured proton energy (E{sub p} = 1805{+-}20 keV) and decay half-life (t{sub 1/2} = 21{+-}4 {mu}s) with values calculated using the WKB method indicate that the proton is emitted from an h{sub 11/2} state. The implications of these results for future experimental investigations into even more proton unbound Re isotopes using in-flight separation techniques are considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monocrystalline diamond detector for ionizing radiation emitted by high temperature laser-generated plasma

A monocrystalline diamond detector was used for measurements of soft x-ray and ion emission from laser plasma obtained with the use of the PALS Asterix laser at intensities on the order of 10{sup 16} W/cm{sup 2} and pulse duration of 300 ps. Measurements were performed by varying the laser intensity and the focal position of the laser beam with respect to the target position. The spectra were obtained with the use of a diamond detector, which was without a filter, and showed not only the photopeak due to UV and soft x rays but also the ions emitted from the plasma. The detector was employed with absorbers of different thicknesses to determine, as a first approximation, the energy distribution of soft x-ray emission from the plasma. The time-of-flight technique was employed to determine the ion kinetic energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Femtosecond laser induced coordination transformation and migration of ions in sodium borate glasses

We report on the coordination transformation of B{sup 3+} ions and migration of Na{sup +} and O{sup 2-} ions in sodium borate glasses, induced by 250 kHz, 800 nm femtosecond laser irradiation. Micro-Raman spectra show that the ratio of the integrated intensity of the two peaks at 806 and 774 cm{sup -1} decreases at first and then increases with increasing distance from the center of the laser modified zone. Electron dispersive x-ray spectra show that a portion of Na{sup +} and O{sup 2-} ions migrate from the vicinity of focal point after the femtosecond laser irradiation. A possible mechanism is proposed to explain the observed phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser beam-profile impression and target thickness impact on laser-accelerated protons

Experimental results on the influence of the laser focal spot shape onto the beam profile of laser-accelerated protons from gold foils are reported. The targets' microgrooved rear side, together with a stack of radiochromic films, allowed us to deduce the energy-dependent proton source-shape and size, respectively. The experiments show, that shape and size of the proton source depend only weakly on target thickness as well as shape of the laser focus, although they strongly influence the proton's intensity distribution. It was shown that the laser creates an electron beam that closely follows the laser beam topology, which is maintained during the propagation through the target. Protons are then accelerated from the rear side with an electron created electric field of a similar shape. Simulations with the Sheath-Accelerated Beam Ray-tracing for IoN Analysis code SABRINA, which calculates the proton distribution in the detector for a given laser-beam profile, show that the electron distribution during the transport through a thick target (50 {mu}m Au) is only modified due to multiple small angle scattering. Thin targets (10 {mu}m) show large source sizes of over 100 {mu}m diameter for 5 MeV protons, which cannot be explained by multiple scattering only and are most likely the result of refluxing electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A subnanosecond pulsed ion source for micrometer focused ion beams

A new, compact design of an ion source delivers nanosecond pulsed ion beams with low emittance, which can be focused to micrometer size. By using a high-power, 25 fs laser pulse focused into a gas region of 10{sup -6} mbar, ions at very low temperatures are produced in the small laser focal volume of 5 {mu}m diameter by 20 {mu}m length through multiphoton ionization. These ions are created in a cold environment, not in a hot plasma, and, since the ionization process itself does not significantly heat them, have as a result essentially room temperature. The generated ion pulse, up to several thousand ions per pulse, is extracted from the source volume with ion optical elements that have been carefully designed by simulation calculations. Externally triggered, its subnanosecond duration and even smaller time jitter allow it to be superimposed with other pulsed particle or laser beams. It therefore can be combined with any type of collision experiment where the size and the time structure of the projectile beam crucially affect the achievable experimental resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy of odd-proton nuclei in the region of {sup 254}No

Two rotational bands have been found in the transfermium nuclei {sup 251}Md and {sup 255}Lr, the latter being the heaviest nucleus so far studied in-beam. Both are assigned to a [521]1/2{sup -} Nilsson state by comparison to theory. The experiments have been carried out in the Accelerator Laboratory of the University of Jyvaeskylae (JYFL), where the array of germanium detectors JUROGAM was used in conjunction with the recoil-seperator RITU and the focal-plane setup GREAT for gamma-spectroscopic studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser ablation-induced spectral plasma characteristics in optical far- and near fields

The aim of this work is to elucidate the ablation-induced plasma physics for chemical species analysis by laser-induced breakdown spectroscopy at higher spatial resolution. To accomplish this, the effect of the laser spot size on the laser ablation-induced plasma characteristics is experimentally investigated, both in optical far-field and near-field ablation configurations, utilizing a Cr thin film of {approx}200 nm thickness on quartz substrate as a target. The far-field ablation is affected under tight focusing conditions, wherein nanosecond laser pulses of 532 nm wavelength are focused to laser focal spot diameters of {approx}7 and 1.5 {mu}m. The measured results show that the ablation-induced plasma from sub-10 {mu}m ablation craters exhibits complex three-dimensional behavior, leading to greatly reduced laser-plasma interaction and an order of magnitude shorter plasma lifetime. Nanosecond laser pulses of 532 nm wavelength are also coupled to a pulled fiber based near-field scanning optical microscopy probe. Due to the sharp tip presence in close proximity of the ablation craters, entirely different plasma evolution behavior is observed, highlighted by orders of magnitude shorter plasma lifetime and strongly directional material ejection. The ablation-induced plasma from reduced lateral crater dimensions both in far- and near-field shows improved contrast of atomic transition signals with respect to the wide-spectrum background, hence confirming the potential for laser-induced breakdown spectroscopy with high spatial resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗