Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Experimental Study of Counterflow Cooling Using a Test Loop to Simulate the Thermal Characteristics of a HTS Cable System

The counterflow cooling configuration is a compact, efficient, and relatively low cost thermal management approach for long-length HTS cable systems. In the counter-flow cooling configuration the coolant flow, typically liquid nitrogen, is initially supplied through the center of the cable turning around at the far end of the cable and returning through the annular space between the cable and the inner cryostat wall, using a single cryostat. The temperature distributions along the cable and the nitrogen flow streams are extremely difficult to measure in an operating HTS cable because of the issues associated with installing thermometers on high voltage components. A 5-meter long test loop has been built that simulates a counter-flow cooled, HTS cable using a heated metal tube to simulate the cable. The test loop contains calibrated thermometers to measure the temperature distribution along the tube and the return liquid nitrogen stream. Measured temperature distributions in the return flow stream and along the tube wall for varying flow rates and heating conditions to simulate a HTS cable are presented and discussed.

Demko, Jonathan A↗

The Impact of Refrigerant Charge, Air Flow and Expansion Devices on the Measured Performance of an Air-Source Heat Pump Part I

This paper describes extensive tests performed on a 3-ton R-22 split heat pump in heating mode. The tests contain 150 steady-state performance tests, 18 cyclic tests and 18 defrost tests. During the testing work, the refrigerant charge level was varied from 70 % to 130% relative to the nominal value; the outdoor temperature was altered by three levels at 17 F (-8.3 C), 35 F (1.7 C) and 47 F (8.3 C); indoor air flow rates ranged from 60% to 150% of the rated air flow rate; and the expansion device was switched from a fixed-orifice to a thermal expansion value. Detailed performance data from the extensive steady state cyclic and defrost testing performed were presented and compared.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A GPU-based 2D shallow water quality model

In this paper, a 2D shallow water flow solver integrated with a water quality model is presented. The interaction between the main water quality constituents included is based on the Water Quality Analysis Simulation Program. Efficiency is achieved by computing with a combination of a Central Processing Unit (CPU) and a Graphics Processing Unit (GPU) device. This technique is intended to provide robust and accurate simulations with high computation speedups with respect to a single-core CPU in real events. The proposed numerical model is evaluated in cases that include the transport and reaction of water quality components over irregular bed topography and dry–wet fronts, verifying that the numerical solution in these situations conserves the required properties (C-property and positivity). The model can operate in any steady or unsteady form allowing an efficient assessment of the environmental impact of water flows. The field data from an unsteady river reach test case are used to show that the model is capable of predicting the measured temporal distribution of dissolved oxygen and water temperature, proving the robustness and computational efficiency of the model, even in the presence of noisy signals such as wind speed.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Evaluation of Energy Recovery Ventilators

Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well. Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates. The use of energy recovery ventilators (ERVs) in tight homes in mixed-humid and hot-humid climates is already practiced. Unbalancing the ERV by reducing exhaust airflows can provide a means to supply makeup air and reduce the level of home depressurization to mitigate these issues, helping to realize the rated performance of the exhaust-only appliances, achieve safe operation of atmospherically vented combustion, provide the necessary level of fresh ventilation air, and/or improve envelope durability. The unbalanced operation of the ERV to address depressurization can obviously result in unintended consequences in other areas, such as further loss of humidity control in homes in more humid climates. In such tight home scenarios, it is expected that ERVs will operate a substantial amount of time in unbalanced mode with much higher supply than exhaust airflows. Although ERV design performance under balanced flow conditions is well documented, there is no information in the public domain that empirically establishes the effect of unbalanced flow on sensible and latent exchange, especially in the now dominant membrane-type ERV used in residential applications. Therefore, in this task, Gas Technology Institute (GTI) focused on a laboratory evaluation of the unbalanced flow (lowered exhaust airflow) performance of the RenewAire model EV 200, membrane-type ERV delivering 200 standard cubic feet per minute (SCFM) of supply air. The conducted tests show significant variation in ERV effectiveness at different levels of unbalanced air flows. Keeping supply airflow constant and lowering exhaust airflow increases effectiveness of both latent and sensible heat exchange. However, the increased effectiveness is accompanied by reduced capacity for load removal from the supply air, resulting in increased load to the conditioned space. Under decreasing exhaust airflow conditions, sensible load effectiveness exceeded a value of 1 at two sets of testing conditions. This was a result of the temperature rise of the supply air passing through the ERV augmented by the effect of motor heat gain, cross leakage heat gain, and casing heat gain. Consequently, measured sensible effectiveness must be qualified as the so-called Apparent Sensible Effectiveness of the ERV unit (the term used in the Canadian Standards Association C439 standard for testing ERVs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Transport Equation Approach to Modeling the Influence of Surface Roughness on Boundary Layer Transition

A computational investigation has been performed to better understand the impact of surface roughness on the flow over a contaminated surface. This report highlights the implementation and development of the roughness amplication model in the flow solver OVER FLOW-2. The model, originally proposed by Dassler, Kozulovic, and Fiala, introduces an additional scalar field roughness amplification quantity. This value is explicitly set at rough wall boundaries using surface roughness parameters and local flow quantities. The additional transport equation allows non-local effects of surface roughness to be accounted for downstream of rough sections. This roughness amplification variable is coupled with the Langtry-Menter model and used to modify the criteria for transition. Results from at plate test cases show good agreement with experimental transition behavior on the flow over varyings and grain roughness heights. Additional validation studies were performed on a NACA 0012 airfoil with leading edge roughness. The computationally predicted boundary layer development demonstrates good agreement with experimental results. New tests using varying roughness configurations have been carried out at the Texas A&M Oran W. Nicks Low Speed Wind Tunnel to provide further calibration of the roughness amplification method. An overview and preliminary results are provided of this concurrent experimental investigation.

17 WIND ENERGY↗

Completion Report for Model Evaluation Well ER-5-5: Corrective Action Unit 98: Frenchman Flat

Model Evaluation Well ER-5-5 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of Nevada Environmental Management Operations at the Nevada National Security Site (formerly known as the Nevada Test Site). The well was drilled in July and August 2012 as part of a model evaluation well program in the Frenchman Flat area of Nye County, Nevada. The primary purpose of the well was to provide detailed geologic, hydrogeologic, chemical, and radiological data that can be used to test and build confidence in the applicability of the Frenchman Flat Corrective Action Unit flow and transport models for their intended purpose. In particular, this well was designed to obtain data to evaluate the uncertainty in model forecasts of contaminant migration from the upgradient underground nuclear test MILK SHAKE, conducted in Emplacement Hole U-5k in 1968, which were considered to be uncertain due to the unknown extent of a basalt lava-flow aquifer present in this area. Well ER-5-5 is expected to provide information to refine the Phase II Frenchman Flat hydrostratigraphic framework model, if necessary, as well as to support future groundwater flow and transport modeling. The 31.1-centimeter (cm) diameter hole was drilled to a total depth of 331.3 meters (m). The completion string, set at the depth of 317.2 m, consists of 16.8-cm stainless-steel casing hanging from 19.4-cm carbon-steel casing. The 16.8-cm stainless-steel casing has one slotted interval open to the basalt lava-flow aquifer and limited intervals of the overlying and underlying alluvial aquifer. A piezometer string was also installed in the annulus between the completion string and the borehole wall. The piezometer is composed of 7.3-cm stainless-steel tubing suspended from 6.0-cm carbon-steel tubing. The piezometer string was landed at 319.2 m, to monitor the basalt lava-flow aquifer. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, preliminary water quality measurements, and water-level measurements. The well penetrated 331.3 m of Quaternary–Tertiary alluvium, including an intercalated layer of saturated basalt lava rubble. No well development or hydrologic testing was conducted in this well immediately after completion; however, a preliminary water level was measured in the piezometer string at the depth of 283.4 m on September 25, 2012. No tritium above the minimum detection limit of the field instruments was detected in this hole. Future well development, sampling, and hydrologic testing planned for this well will provide more accurate hydrologic information for this site. The stratigraphy, general lithology, and water level were as expected, though the expected basalt lava-flow aquifer is basalt rubble and not the dense, fractured lava as modeled. The lack of tritium transport is likely due to the difference in hydraulic properties of the basalt lava-flow rubble encountered in the well, compared to those of the fractured aquifer used in the flow and transport models.

58 GEOSCIENCES↗

Numerical modeling and experimental verification of flow and heat transfer over serrated fins at low Reynolds number

The objectives of this paper are to establish a numerical modeling method incorporated with few experiments by which the performance of fins with new configuration in plate-fin heat exchangers (PFHE) can be obtained and to investigate the pressure drop and heat transfer characteristics over serrated fins in PFHE at low Reynolds number in detail. First, a variety of performance tests of PFHE were carried out with a constant air flow rate and six different oil flow rates. The Reynolds number ranged from 10 to 200 at the oil side. The Colburn factor j and friction factor f have been calculated from the experimental data. Secondly, the 3D heat transfer and pressure drop of PFHE were analyzed numerically by solving governing equations through two steps of increasing complexity. The first step was a simple model built to obtain the temperatures of separating walls. In this way, the overall heat performances were evaluated. The next step was a small scare with a high detail in the geometry description of the serrated fins at the oil side. The oil velocity and temperature distributions are shown in this step. Also presented and discussed in a detail description of local and average heat transfer characteristics of the serrated fins. The experimental results show good agreement with the corresponding numerical predictions. Hence, the numerical analysis procedure proposed in this paper can be used to predict the performance of new type fins. (author)

42 ENGINEERING↗

Zero Degree Line Mo Target Thermal Test Results and Analysis

Target testing at 35 and 42 MeV was completed on January 14, 2015. At 35 MeV the current was varied from 177 to 375 μA with helium mass flow rate varied from 45 up to 101 g/s. At 42 MeV only one current, 170 mA, was tested because of accelerator performance limitations. The target design for this test, and the subsequent production tests, is largely unchanged from the earlier design for ANL beam tests at lower energy and higher current, comprised of 25 Mo disks 1 mm thick spaced 0.5 mm apart for helium coolant flow gaps. Disks are 12 mm diameter, with expected beam size 6 mm FWHM. Because the target, particularly the window, was designed for lower energy and higher current, the intercepted beam (beam heating) was much less during these tests. Therefore, the thermal stress and, more importantly, reduction in material strength resulting from high temperature, was not a limiting concern. The intended result of the thermal test is to measure heat transfer as a function of helium mass flow rate. Heat transfer coefficient was determined by the measurement of temperature at the center of the first 8 Mo disks while varying helium flow rate and beam current. The performance was then compared to predictive tools: Heat transfer correlations in the literature and finite element analysis using ANSYS

42 ENGINEERING↗

Development of a core coolant flow distribution calculation code for HTGRs - 18484

In order to ensure the thermal integrity of fuel in high temperature gas-cooled reactors (HTGRs), it is necessary that the maximum fuel temperature in the normal operation is to be lower than the thermal design target. In the core thermal-hydraulic design of block-type HTGRs, the maximum fuel temperature should be evaluated considering data such as thermal power, core geometry, power and neutron fluence distributions, and core coolant flow distribution. The core coolant flow distribution calculation code used in the design stage of High Temperature engineering Test Reactor (HTTR) presupposes to run on UNIX systems, and its operation and execution procedure are complicated and not user-friendly. Therefore, a new core coolant flow distribution calculation code with a user-friendly system such as simple and easy operations and execution procedures has been developed. In this paper, the outline of the new code is described and the simulation result of an out-of-pile test with one fuel column are shown as the first step of the code validation. The simulation results provide good agreement with the test one. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BENCH SCALE SALTSTONE PROCESS DEVELOPMENT MIXING STUDY

The Savannah River National Laboratory (SRNL) was requested to develop a bench scale test facility, using a mixer, transfer pump, and transfer line to determine the impact of conveying the grout through the transfer lines to the vault on grout properties. Bench scale testing focused on the effect the transfer line has on the rheological property of the grout as it was processed through the transfer line. Rheological and other physical properties of grout samples were obtained prior to and after pumping through a transfer line. The Bench Scale Mixing Rig (BSMR) consisted of two mixing tanks, grout feed tank, transfer pump and transfer hose. The mixing tanks were used to batch the grout which was then transferred into the grout feed tank. The contents of the feed tank were then pumped through the transfer line (hose) using a progressive cavity pump. The grout flow rate and pump discharge pressure were monitored. Four sampling stations were located along the length of the transfer line at the 5, 105 and 205 feet past the transfer pump and at 305 feet, the discharge of the hose. Scaling between the full scale piping at Saltstone to bench scale testing at SRNL was performed by maintaining the same shear rate and total shear at the wall of the transfer line. The results of scaling down resulted in a shorter transfer line, a lower average velocity, the same transfer time and similar pressure drops. The condition of flow in the bench scale transfer line is laminar. The flow in the full scale pipe is in the transition region, but is more laminar than turbulent. The resulting plug in laminar flow in the bench scale results in a region of no-mixing. Hence mixing, or shearing, at the bench scale should be less than that observed in the full scale, where this plug is non existent due to the turbulent flow. The bench scale tests should be considered to be conservative due to the highly laminar condition of flow that exists. Two BSMR runs were performed. In both cases, wall shearing was shown to reduce the rheological properties of the grout as it was processed through the transfer line. Samples taken at the static feed tank showed that gelling impacted the rheological properties of the grout before it was fed into the pump and transfer line. A comparison of the rheological properties of samples taken at the feed tank and transfer line discharge indicated shearing of the grout was occurring in the transfer line. Bench scale testing of different mixing methods with three different salt solutions showed that method of mixing influences the rheological properties of the grouts. The paddle blade mixing method of the salt solution used for the BMSR testing provided comparable rheological properties of the grout prepared in the BMSR after 14 minutes of processing, B3. The paddle blade mixing method can be used to represent BMSR results and mixing time can be adjusted to represent larger scale mixing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of an ammonia-based wet scrubbing process in a continuous flow system

A continuous gas and liquid flow, regenerative scrubbing process for CO{sub 2} capture was demonstrated at the bench-scale level. An aqueous ammonia-based solution captures CO{sub 2} from simulated flue gas in an absorber and releases a nearly pure stream of CO{sub 2} in the regenerator. After the regeneration, the solution of ammonium compounds is recycled to the absorber. The design of a continuous flow unit was based on earlier exploratory results from a semi-batch reactor, where a CO{sub 2} and N{sub 2} simulated flue gas mixture flowed through a well-mixed batch of ammonia-based solution. During the semi-batch tests, the solution was cycled between absorption and regeneration steps to measure the carrying capacity of the solution at various initial ammonia concentrations and temperatures. Consequentially, a series of tests were conducted on the continuous unit to observe the effect of various parameters on CO{sub 2} removal efficiency and regenerator effectiveness within the flow system. The parameters that were studied included absorber temperature, regenerator temperature, initial NH{sub 3} concentration, simulated flue gas flow rate, liquid solvent inventory in the flow system, and height of the packed-bed absorber. From this testing and subsequent testing, ammonia losses from both the absorption and regeneration steps were quantified, and attempts were made to maintain steady state during operations. Implications of experimental results with respect to process design are discussed.

54 ENVIRONMENTAL SCIENCES↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

An Expert Elicitation Process in Support of Groundwater Model Evaluation for Frenchman Flat, Nevada National Security Site

The U.S. Department of Energy is implementing corrective actions at facilities where nuclear-related operations were conducted in Nevada. Among the most significant sites being addressed are the locations of underground nuclear tests on the Nevada National Security Site (NNSS). The process for implementing corrective actions for the Underground Test Area (UGTA) locations is defined in Appendix VI of a Federal Facility Agreement and Consent Order (1996, as amended). In broad terms, Appendix VI describes a Corrective Action Investigation followed by a Corrective Action Decision, and implementation of a Corrective Action Plan prior to closure. The Frenchman Flat Corrective Action Unit (CAU) is farthest along in the UGTA corrective action process. It includes ten underground tests within the Frenchman Flat topographic basin, in the southeastern portion of the NNSS. Data have been collected from drilling exploration, hydrologic testing, and field and laboratory studies. Modeling has been completed at a variety of scales and focusing on a variety of flow and transport aspects ranging from regional boundary conditions to process dynamics within a single nuclear cavity. The culmination of the investigations is a transport model for the Frenchman Flat CAU (Stoller Navarro Joint Venture, 2009) that has undergone rigorous peer review and been accepted by the State of Nevada, setting the stage for the Corrective Action Decision and progression from the investigation phase to the corrective action phase of the project.

(1996↗

Preliminary modeling of triply periodic minimal surface (TPMS) structures using RELAP5-3D

With the United States Department of Energy (DOE)’s goal of quadrupling the nation’s nuclear energy supply by 2050, and with the Advanced Fuels Campaign pushing for new types of advanced reactor fuels and geometries, the need has arisen for new nuclear fuel designs. One such design is to swap out current nuclear fuel geometries in exchange for another type of geometry, called a Triply Periodic Minimal Surface (TPMS). TPMSs are self-supporting, infinitely repeating lattices—attributes that lend themselves well to additive manufacturing. These surfaces also possess enhanced heat transfer properties thanks to their internal area changes and large surface-area-to-volume ratios. Their drawback, however, is an increased pressure drop. Given the small amount of correlations and data (Reynolds numbers in the 2,000–8,000 range), and the minimal amount of experience so far obtained by modeling TPMS structures using 1D systems codes such as the Reactor Excursion and Leak Analysis Program (RELAP5-3D), further research into this topic was needed. Using data from the University of Wisconsin - Madison (UW), curve fits were created for both a Heat Transfer Coefficient (HTC) correlation and a Darcy friction factor empirical coefficient correlation. The curves’ coefficients and multipliers were then output and utilized in RELAP5-3D models of two upcoming experiments—Flow Loop for INFLUX Pressure drop (FLIP) and Microreactor Agile Non-nuclear Experimental Test (MAGNET)—aimed at increasing the available data for Reynolds numbers to the 16,000–36,000 range for TPMS structures. The models were run under the conditions utilized by a Computational Fluid Dynamics (CFD) analysis performed by another group at Idaho National Laboratory. Only CFD pressure drop values were obtained from the FLIP test, and those values showed that the RELAP5-3D models had a lower rate of pressure increase in comparison to the CFD values. In addition, there seemed to be a vertical shift upward in the pressure drop for both models whenever the TPMS porosity decreased, and the RELAP5-3D models showed a higher vertical shift in comparison to the CFD values. The MAGNET results did not correspond to any CFD or experimental results against which they could be compared, so they were instead compared against the proposed CFD input conditions. These values were then compared with each other to make sure the model seemed to be performing as expected, paving the way for future tests that can be run for the purpose of further analyses and comparisons. The pressure drop increased with temperature and mass flow rate independently. The temperature change would decrease with increasing mass flow rate and temperature, which was just as we expected based on the fact that the lower viscosity and decreased density would result in higher friction and churning losses. The last metric that was assessed was the enthalpy flow change, which increased with increasing mass flow rate and decreasing temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overlapping Domain Coupling of Multidimensional and System Codes in NEAMS - Pronghorn and SAM

This report describes the implementation and testing of domain-overlapping coupling of the Pronghorn and SAM codes. Both Pronghorn and SAM are codes developed by the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program for analysis of advanced nuclear reactors. Pronghorn focuses on analyzing multi-dimensional core flow conditions, while SAM focuses on analysis of the entire system including, among other components, piping, pumps, and heat exchangers. It is desirable for many advanced reactor thermal-hydraulics simulations to couple Pronghorn and SAM to obtain self-consistent solutions in the core and the system. The domain-overlapping coupling approach provides a robust and numerically efficient candidate for this coupling. We describe the algorithm for obtaining self-consistent solutions between a SAM network of flow channels and an overlapped multi-dimensional Pronghorn domain. The algorithm is tested for a variety of simple canonical test problems and a model of the Molten Salt Reactor Experiment (MSRE). Results demonstrate that the domain overlapping coupling approach provides consistent pressure, mass flow rate, enthalpy, and passive scalar distributions between Pronghorn and SAM and converges reliably and efficiently (at most 15 iterations, usually much less than 10) for the considered test problems.

97 MATHEMATICS AND COMPUTING↗

Completion Report for Well ER-3-3 Corrective Action Unit 97: Yucca Flat/Climax Mine, Revision 0

Well ER-3-3 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled and completed from February 21 to March 15, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Yucca Flat/Climax Mine Corrective Action Unit (CAU) 97. The primary purpose of the well was to collect hydrogeologic data to assist in validating concepts of the flow system within the Yucca Flat/Climax Mine CAU, and to test for potential radionuclides in groundwater from the WAGTAIL (U3an) underground test.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of the sub-micron ash aerosol generated during oxy-coal combustion at atmospheric and elevated pressures

This paper is concerned with the effect of pressure on the particle size distribution and the size-segregated composition of the sub-micron ash aerosol created during oxy-coal combustion under near practical self-sustaining combustion conditions. The problem is important because pressurized oxy-coal combustion has been proposed as one promising technology to minimize CO 2 emissions. Sub-micron ash plays a major role in ash deposition mechanisms, which, in turn, can control boiler performance. In this work, the same bituminous coal was burned at pressures of 1, 8 and 15 bar in O 2 /CO 2 environments. Here, tests employed a 100 kW (rated) oxy-fuel combustor (OFC) operated at atmospheric pressure (1 bar) and a 300 kW (rated) entrained-flow pressurized reactor (EFPR) at elevated pressures (8 and 15 bar). Although these tests were conducted under near practical combustion conditions, confounding effects of peak flame temperature variations were minimized for the 1 bar and 15 bar tests, allowing the role of elevated pressure to be isolated. For the EFPR tests, a specially designed sampling system was used to sample sub-micron ash aerosols from the pressurized combustor and is described in detail. Results showed that at the same peak temperature but higher pressure, the fractions of ash aerosol partitioned into the PM 0.6 and PM 1 size fractions were greatly diminished. Moreover, elevated pressures caused significant changes in the composition of the (size-segregated) sub-micron aerosol, especially in its alkali content, which increased significantly. Examination of fractions of each element that ended up in the sub-micron fume suggested that, at constant temperature, the effect of pressure on vaporization of semi-volatile metals was very different from that on the release into the gas phase of non-volatile metals and could not be explained by equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗