Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Development of a Maxwell X-57 High Lift Motor Reference Design

NASA's all-electric X-57 airplane will utilize 14 electric motors, of which 12 are exclusively for lift augmentation during takeoff and landing. This report covers the design and development process taken to create an open reference model representative of the 12 lift augmenting motors. A combined worst case scenario was used as the design point, which represents the simultaneously occurring worst case aspects of thermal, static stress, electromagnetic, and rotor dynamic conditions. This work also highlights the tightly coupled nature of aerospace electric motor design, requiring constant iteration between all disciplines involved. Further adding to the uniqueness is the cooling method, which is limited to nacelle skin forced convection cooling only, no internal air flow is permitted. The stator outer diameter limit of 156.45 mm greatly impacts the degree of coupling between the electromagnetic design with the thermal analysis. The permanent magnet synchronous motor developed here operates between 385 V and 538 V, at a peak current of 50 A. Detailed electromagnetic, thermal, static load, and rotordynamic analysis was completed for this electric motor; all of which are required for a full design. The rotordynamic analysis took into consideration the motor housing which is designed specifically for this motor. The final electric motor has a mass of 2.34 kg, produces 24.1 Nm of torque with a specific power of 5.56 kW/kg, and has an efficiency of 96.61% at the combined worst case design point.

Electric Aircraft↗

The Impacts of Demand Response Participation in Capacity Markets

Demand Response is capable of reducing the total amount of generation capacity investment required to ensure electricity system security. We utilise this fact to devise a novel methodology to estimate the contribution of a load-shifting demand response resource to system adequacy. We then simulate an electricity market using mixed complementarity models to determine how the participation of demand response in capacity markets impacts on market outcomes. Demand response primarily affects the equilibrium outcome through the energy market, however demand response also reduces both equilibrium prices and consumer costs through its capacity market contribution. The effect is particularly pronounced when there is a high level of variable renewable generation and initial undercapacity. In the absence of demand response, increased wind generation leads to higher capacity prices as generators seek to offset depressed energy prices. However, we find that demand response's participation in the capacity market can combat these increased capacity prices. These results suggest that demand response participation in capacity markets can mitigate some of the market challenges of renewable integration, particularly that of the 'missing money' problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Subscale Hardware-In-The-Loop Results for Hybrid Electric Turbofan Controls Use Cases

NASA is investigating hybrid electric turbine engine systems for commercial transport aircraft due to the potentially significant improvements hybrid electric technology offers in performance, fuel consumption, and operational and design flexibility. Recently, the technology has been tested at full scale in partnership with industry and advanced to Technology Readiness Level 4. This presentation will focus on a recent subscale hardware-in-the-loop test of an open source turbofan engine model developed by NASA. The Advanced Geared Turbofan 30,000 lbf – electrified (AGTF30-e) engine is used as a reference model to demonstrate control system design and use cases for an example mild hybrid electric system with no large-scale energy storage. This model is run in real-time in NASA’s Hybrid Propulsion Emulation Rig (HyPER) and is used to drive an emulation of the turbomachinery system using subscale electric machines. This dynamic scaled shaft emulation interacts with a subscale (<100 kW) hybrid system consisting of electric machines, motor controllers, and a programmable electronic load. Specific use cases demonstrated include the use of Turbine Electrified Energy Management to improve operation during transients, megawatt-scale power extraction from the AGTF30-e, and power transfer between engine spools. Results related to the effectiveness of hybrid systems are qualitatively compared to results from industry testing.

Hybrid↗

Development of a Hydronic Rooftop Unit-HyPak-MA

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Morphological and electrical properties of epoxy-based composites reinforced with exfoliated graphite

An experimental study has been carried out to prepare and characterize epoxy/amine-based composites filled with different percentages of partially exfoliated graphite (i.e. pEG) particles having an exfoliation degree of 56% in order to analyze the effect of the filler amounts on the electrical properties of the resulting nanocomposites. Moreover, in order to fully investigate the direct relationship between the physical properties of the employed filler and the results of the electrical characterization, a structural and morphological characterization of the pEG samples is carried out by means of various type of analysis such as X-ray diffraction patterns, micro-Raman and Scanning Electron Microscopy (SEM) images. The DC electrical characterization reveals a percolation thresholds (EPT) that falls in the range [2–3] wt% and an electrical conductivity of about 0.66 S/m at the highest filler loading (6.5 wt%). From the analysis of the percolative curve it is possible to derive the percolation law parameters and in particular the critical exponent t, whose value (i.e. 1.2) reflects an effective 2D organization of the percolating structure consistent with the type of filler used (2-dimensional). Finally, an extensive analysis concerning the electrical properties in the frequency domain has been carried out in order to evaluate the effectiveness of pEG-loaded composites in terms of electromagnetic interference compatibility (EMC) and their applicability as radar absorbers materials (RAMs).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The effect of molecular mobility on electronic transport in carbon nanotube-polymer composites and networks

A multiscale modeling approach to the prediction of electrical conductivity in carbon nanotube (CNT)–polymer composite materials is developed, which takes into account thermally activated molecular mobility of the matrix and the CNTs. On molecular level, a tight-binding density functional theory and non-equilibrium Green's function method are used to calculate the static electron transmission function in the contact between two metallic carbon nanotubes that corresponds to electron transport at 0 K. For higher temperatures, the statistical distribution of effective contact resistances is considered that originates from thermal fluctuations of intermolecular distances caused by molecular mobility of carbon nanotube and the polymer matrix. Based on this distribution and using effective medium theory, the temperature dependence of macroscopic electrical resistivity for CNT-polymer composites and CNT mats is calculated. The predicted data indicate that the electrical conductivity of the CNT-polymer composites increases linearly with temperature above 50 K, which is in a quantitative agreement with the experiments. Our model predicts a slight nonlinearity in temperature dependence of electric conductivity at low temperatures for percolated composites with small CNT loading. The model also explains the effect of glass transition and other molecular relaxation processes in the polymer matrix on the composite electrical conductivity. The developed multiscale approach integrates the atomistic charge transport mechanisms in percolated CNT-polymer composites with the macroscopic response and thus enables direct comparison of the prediction with the measurements of macroscopic material properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TEM Cell Testing of Cable Noise Reduction Techniques From 2 MHz to 200 MHz - Part 1

This paper presents empirical results of cable noise reduction techniques as demonstrated in a TEM cell operating with radiated fields from 2 - 200 MHz. It is the first part of a two-paper series. This first paper discusses cable types and shield connections. In the second paper, the effects of load and source resistances and chassis connections are examined. For each topic, well established theories are compared to data from a real-world physical system. Finally, recommendations for minimizing cable susceptibility (and thus cable emissions) are presented. There are numerous papers and textbooks that present theoretical analyses of cable noise reduction techniques. However, empirical data is often targeted to low frequencies (e.g. <50 KHz) or high frequencies (>100 MHz). Additionally, a comprehensive study showing the relative effects of various noise reduction techniques is needed. These include the use of dedicated return wires, twisted wiring, cable shielding, shield connections, changing load or source impedances, and implementing load- or source-to-chassis isolation. We have created an experimental setup that emulates a real-world electrical system, while still allowing us to independently vary a host of parameters. The goal of the experiment was to determine the relative effectiveness of various noise reduction techniques when the cable is in the presence of radiated emissions from 2 MHz to 200 MHz. The electronic system (Fig. 1) consisted of two Hammond shielded electrical enclosures, one containing the source resistance, and the other containing the load resistance. The boxes were mounted on a large aluminium plate acting as the chassis. Cables connecting the two boxes measured 81 cm in length and were attached to the boxes using standard D38999 military-style connectors. The test setup is shown in Fig. 2. Electromagnetic fields were created using an HP8657B signal generator, MiniCircuits ZHL-42W-SMA amplifier, and an EMCO 5103 TEM cell. Measurements were taken using an Agilent E4401B spectrum analyzer and HP1141a differential probes.

Bradley, Arthur T.↗

Evaluation of an operating MOD-OA 200 kW wind turbine blade

Operating loads and structural damage were monitored during operation of the MOD-OA electric generating system. The turbine was damaged locally between stations 48 and 125 after 2.8 million rotations. Loads due to degraded yaw stiffness and fretting at rib station 48 were identified as primary to this distress. The repaired blades operated an additional 4.8 million rotations without problems.

Donham, R. E.↗

A Multiport DC Transformer to Enable Flexible Scalable DC as a Service

The rapid adoption of new DC loads and sources, including photovoltaic arrays, DC fast charging of electric vehicle, battery energy storage and data centers, requires a large amount of DC power conversion. A majority of new deployments also necessitate the integration of multiple DC loads and sources at one site. The traditional approach to serve these new applications relies on multiple standard power converters, each dedicated to a source or load, and results in highly customized systems, with challenging control coordination, complex protection strategies, and poor scalability. Instead, this paper proposes the concept of a multiport DC transformer (MDCT) as a modular building block for realizing a flexible, scalable DC as a Service system and address this rapidly growing need. The MDCT uses the S4T to achieve very tight control of cycle-by-cycle energy exchange between multiple ports, with high efficiency. A single multiport converter replaces 4-6 distinct converters, integrates all energy flows and manages protection. As a result, a new layered control architecture is introduced to ensure stability and scalability of the MDCT, with multiple S4T power converter building blocks connected in parallel to realize a fully modular system and reach the target power levels.

30 DIRECT ENERGY CONVERSION↗

Analyzing SCM Grid Benefits from Electric Transportation [Slides]

Increasing adoption of EVs and expanding unmanaged charging loads could increase the cost of transportation energy due to increasing load variability and shrinking infrastructure capacity. The actual cost of transportation energy, such as charging an EV, depends on several factors including energy costs, charging infrastructure costs, and applicable grid upgrades. Based on studies from past DOE projects; RECHARGE, DirectXFC, FUSE and 21st Century Truck Partnership (21CTP) the EV-CENTS project will develop a transportation energy cost metric to better quantify these factors and provide a framework for assessing the value potential of new technology solutions, such as smart charge management (SCM), which could reduce these costs for all stakeholders. The initial assessment will focus on the cost of charging, which will vary across vehicle classes such as light-duty vehicles (LDV) or medium and heavy-duty vehicles (MHDV), as well as across different vocations resulting in many different use cases for this metric. Cost of charging results will be developed for each use case in both uncontrolled and controlled scenarios to understand the value potential of different SCM objective functions and their ability to optimize the cost of energy and delay or eliminate the need for electrical upgrades.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Time-Varying Passenger Loading on Conventional and Electrified Transit Bus Energy Consumption

Transit bus passenger loading changes greatly over the course of a workday. Therefore, time-varying vehicle mass as a result of passenger load becomes an important factor in instantaneous energy consumption. Battery-powered electric transit buses have restricted range and longer 'fueling' time compared with conventional diesel-powered buses; thus, it is vital to know how much energy they require. Our previous work has shown that instantaneous transit bus mass can be obtained by measuring the pressure in the vehicle's airbag suspension system. This report leverages this novel technique to determine the impact of time-varying mass on energy consumption. Sixty-five days of velocity and mass data were collected from in-use transit buses operating on routes in the Twin Cities, MN metropolitan area. The simulation tool Future Automotive Systems Technology Simulator was modified to allow both velocity and mass as time-dependent inputs. This tool was then used to model an electrified and conventional bus on the same routes and determine the energy use of each bus. Results showed that the kinetic intensity varied from 0.27 to 4.69 mi-1 and passenger loading ranged from 2 to 21 passengers. Simulation results showed that energy consumption for both buses increased with increasing vehicle mass. The simulation also indicated that passenger loading has a greater impact on energy consumption for conventional buses than for electric buses owing to the electric bus's ability to recapture energy. This work shows that measuring and analyzing real-time passenger loading is advantageous for determining the energy used by electric and conventional diesel buses.

33 ADVANCED PROPULSION SYSTEMS↗

The value of residential photovoltaic systems: A comprehensive assessment

Utility-interactive photovoltaic (PV) arrays on residential rooftops appear to be a potentially attractive, large-scale application of PV technology. Results of a comprehensive assessment of the value (i.e., break-even cost) of utility-grid connected residential photovoltaic power systems under a variety of technological and economic assumptions are presented. A wide range of allowable PV system costs are calculated for small (4.34 kW (p) sub ac) residential PV systems in various locales across the United States. Primary factor in this variation are differences in local weather conditions, utility-specific electric generation capacity, fuel types, and customer-load profiles that effect purchase and sell-back rates, and non-uniform state tax considerations. Additional results from this analysis are: locations having the highest insolation values are not necessary the most economically attractive sites; residential PV systems connected in parallel to the utility demonstrate high percentages of energy sold back to the grid, and owner financial and tax assumptions cause large variations in break-even costs. Significant cost reduction and aggressive resolution of potential institutional impediments (e.g., liability, standards, metering, and technical integration) are required for a residential PV marker to become a major electric-grid-connected energy-generation source.

Borden, C. S.↗

A multi-criteria decision analysis-based approach for dispatch of electric microgrids

This paper presents a decision support system (DSS) for multi-objective dispatch of an electric microgrid con-sidering cost of operation, peak load reduction, and emissions. Discrete compromise programming (DCP) is used as the multi-criteria decision analysis (MCDA) technique for providing the decision support to the distribution system operator (DSO) by ranking various alternatives based on preference of the objec-tives. Simulations are performed on a notional electric microgrid based on the IEEE 13-node test feeder and the results are pre-sented with appropriate visualization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NA--SS-SNL-2000-2016-0005 Electrical Shock of Worker Performing R&D Work

At approximately 10am on 6/29/16 during testing of the DVFS2.0 fireset, an employee was shocked by a capacitor as he was removing it from the fireset following a test. The test, which was documented in a Technical Work Document (TWD) was to charge the fireset and discharge it into a fixed resistive load. The fireset was used within a Center 2600 Electrical Safety Box (ESB). Another employee acted as the required Second Person. Following the final test during which the 0.5uF capacitor was charged to 2500V (according to the voltage divider built into the fireset), the capacitor was allowed to discharge.

42 ENGINEERING↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Technology solutions to mitigate electricity cost for electric vehicle DC fast charging

Widespread adoption of alternative fuel vehicles is being hindered by high vehicle costs and refueling or range limitations. For plug-in electric vehicles, direct-current fast charging (DCFC) is proposed as a solution to support long-distance travel and relieve range anxiety. However, DCFC has also been shown to be potentially more expensive compared to residential or workplace charging. In particular, electricity demand charges can significantly impact electricity cost for fast charging applications. Here we explore technological solutions that can help reduce the electricity cost for electric vehicle fast charging. In particular, we consider thousands of electricity rates available in the United States and real-world vehicle charging load scenarios to assess opportunities to reduce the cost of DCFC by deploying solar photovoltaics (PV) panels and energy storage (battery), and implementing a co-location configuration where a DCFC station is connected to an existing meter within a commercial building. Results show that while the median electricity cost across more than 7000 commercial retail rates remains less than $0.20/kWh for all charging load scenarios considered, cost varies greatly, and some locations do experience significantly higher electricity cost. Co-location is almost always economically viable to mitigate fixed cost and demand charges, but the relative benefit of co-locating diminishes as station size and utilization increase. Energy storage alone can help mitigate demand charges and is more effective at reducing costs for 'peaky' or low-utilization loads. On the other hand, PV systems primarily help mitigate energy charges, and are more effective for loads that are more correlated with solar production, even in areas with lower solar resource. PV and energy storage can deploy synergistically to provide cost reductions for DCFC, leveraging their ability to mitigate demand and energy charges.

25 ENERGY STORAGE↗