Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed solar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

A simple method for obtaining a three-dimensional proton distribution function from Voyager plasma data

The main sensor of the Vogager plasma experiment consists of a cluster of three, modulated-grid Faraday cups whose normals are arranged symmetrically about the symmetry axis of the cluster at an angle of 20 degrees to that axis. In interplanetary space, each cup explores the positive ion distribution by accepting particles from contiguous slices in velocity space. The slices are narrow in the direction of the normal to the modulating grid but are broad in planes parallel to that grid. The resulting three sets of measurements can be combined to yield the three-dimensional distribution function in the following way: the distribution function is assumed to be gyrotropic. For each value of speed in a frame of reference moving with the bulk velocity of the solar wind, the variation of the distribution function with angle from the field direction is represented by a series of Legendre polynomials. Effects such as double-streaming and heat flow can be well represented by using only the first three terms of the series which are fully specified by the measurements. Examples of the use of this method in the analysis of Voyager data are shown.

Olbert, S.↗

Relations between the photospheric magnetic field and the emission from the outer atmospheres of cool stars. II - The C IV 1550 A doublet

Solar and stellar data are used to determine the relationship between C IV 1548 + 1551 A and magnetic flux densities. C IV SMM-UVSP spectroheliograms of solar quiet regions and plages are analyzed. Typical distribution functions of C IV flux densities over both quiet and active solar regions are presented. The C IV emission is shown to be dependent on magnetic flux density.

Schrijver, C. J.↗

Visualizing Fault Induced Traveling Waves in Medium Voltage Systems: Preprint

Traveling waves are induced in power systems during most transient events in the grid. These waves travel close to the speed of light in overhead lines and 50% to 60% the speed of light in underground cables. Even though traveling wave-based protection schemes for transmission systems are available commercially, traveling waves in medium voltage distribution networks are still in research space. Compared to transmission system, medium voltage distribution systems contain more reflections and refractions. Thus, visualization is challenging and is critical in locating faults in distribution network. To address this visualization challenge, this paper presents an open-source tool to visualize the traveling waves using Bewley lattice approach. The developed visualization tool will be useful for the protection and safety engineers to detect and triangulate fault locations in the medium voltage systems and isolate the faults.

Bewley Lattice↗

Securing Solar for the Grid: Spring 2024 IAB Meeting

The Spring 2024 IAB meeting will focus on updates from the research team and collective feedback and inputs for an updated Roadmap for Solar Cybersecurity. Researchers from the four DOE National Laboratories will present with industry counterparts for the major research tasks within the S2G program, including: Solar Cybersecurity Standards and Certifications, Solar Risk Assessments & Mitigation, Solar Supply Chain Assessment, Network Monitoring Tools and Analysis, and Training and Workforce Development. Sandia National Laboratories developed an original Roadmap for PV Cybersecurity in 2017. This year, we are updating that roadmap to reflect the current state of research and industry and identify gaps and priorities still to be addressed. We look forward to the IAB’s input on key topics for the roadmap.

14 SOLAR ENERGY↗

Raman scattering characterization of space solar cell structures

A contactless method for the determination of the free-carrier density and the composition distribution across the thickness of 3-5 multi-layer solar cell structures, using the Raman scattering method, is developed. The method includes a step analysis of Raman spectra from optical phonons and phonon-plasmon modes of different layers. The method provides simultaneous measurements of the element composition and the thickness of the structure's layers together with the free-carrier density. The results of measurements of the free-carrier density composition distributions of the liquid phase epitaxy grown AlGaAs/GaAs and GaSb solar cell structures are presented and discussed.

Mintairov, Alexander M.↗

Manifold Insulation for Solar Collectors

Results of computer analysis of effects of various manifold insulation detailed in 23-page report show that if fluid is distributed to and gathered from array of solar collectors by external rather than internal manifold, effectiveness of manifold insulation has major influence on efficiency. Report describes required input data and presents equations that govern computer model. Provides graphs comparing collector efficiencies for representative manifold sizes and insulations.

Source record↗

MAPPING THE DISTRIBUTION OF ELECTRON TEMPERATURE AND Fe CHARGE STATES IN THE CORONA WITH TOTAL SOLAR ECLIPSE OBSERVATIONS

The inference of electron temperature from the ratio of the intensities of emission lines in the solar corona is valid only when the plasma is collisional. Once collisionless, thermodynamic ionization equilibrium no longer holds, and the inference of an electron temperature and its gradient from such measurements is no longer valid. At the heliocentric distance where the transition from a collision-dominated to a collisionless plasma occurs, the charge states of different elements are established, or frozen-in. These are the charge states which are subsequently measured in interplanetary space. We show in this study how the 2006 March 29 and 2008 August 1 eclipse observations of a number of Fe emission lines yield an empirical value for a distance, which we call R{sub t} , where the emission changes from being collisionally to radiatively dominated. R{sub t} ranges from 1.1 to 2.0 R{sub sun}, depending on the charge state and the underlying coronal density structures. Beyond that distance, the intensity of the emission reflects the distribution of the corresponding Fe ion charge states. These observations thus yield the two-dimensional distribution of electron temperature and charge state measurements in the corona for the first time. The presence of the Fe X 637.4 nm and Fe XI 789.2 nm emission in open magnetic field regions below R{sub t} , such as in coronal holes and the boundaries of streamers, and the absence of Fe XIII 1074.7 nm and Fe XIV 530.3 nm emission there indicate that the sources of the solar wind lie in regions where the electron temperature is less than 1.2 x 10{sup 6} K. Beyond R{sub t} , the extent of the Fe X [Fe{sup 9+}] and Fe XI emission [Fe{sup 10+}], in comparison with Fe XIII [Fe{sup 12+}] and Fe XIV [Fe{sup 13+}], matches the dominance of the Fe{sup 10+} charge states measured by the Solar Wind Ion Composition Spectrometer, SWICS, on Ulysses, at -43{sup 0} latitude at 4 AU, in March-April 2006, and Fe{sup 9+} and Fe{sup 10+} charge states measured by SWICS on the Advanced Composition Explorer, ACE, in the ecliptic plane at 1 AU, at the time of both eclipses. The remarkable correspondence between these two measurements establishes the first direct link between the distribution of charge states in the corona and in interplanetary space.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

A data-driven network optimisation approach to coordinated control of distributed photovoltaic systems and smart buildings in distribution systems

The increasing integration of distributed energy resources, including demand-side resources and distributed photovoltaics (PVs), into distribution systems has resulted in more complicated power system operation. A data-driven network optimisation approach is proposed to coordinate the control of distributed PVs and smart buildings in distribution networks considering the uncertainties of solar power, outdoor temperature and heat gain associated with building thermal dynamics. These uncertain parameters have a significant impact on the operation and control of distributed PVs and smart buildings, bringing challenges to the distribution system operation. In the proposed data-driven distributionally robust optimisation (DRO) approach, the Wasserstein ball is used to construct an ambiguity set for the uncertain parameters, which does not require the probability distributions to be known. Furthermore, a conditional value-at-risk is incorporated into the Wasserstein-based DRO model and converted into a computationally tractable mixed-integer convex optimisation problem. Benchmarked with robust optimisation and chance-constrained programming, the proposed data-driven model can give a less conservative robust solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Value Analysis of Medium-Voltage Back-to-Back Converter on DER Hosting Enhancement

This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. Here, the analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CELIAS: Charge, Element and Isotope Analysis System for the SOHO mission

The status and further development as well as first calibration of the CELIAS experiment on SOHO is presented. CELIAS is designed to measure the mass, ionic charge, and energy of low and high speed solar wind of suprathermal ions and of low energy flare particles. Through analysis of the elemental and isotopic abundances (the ionic charge state and velocity distributions of ions originating on the solar atmosphere), the investigation focuses on studying the plasma processes in various temporal and spatial scales in the solar chromosphere, transition zone, and corona. Additionally, the CELIAS experiment includes the Solar EUV Monitor (SEM). This unit, which consists of an EUV transmission grating spectrometer and three isolated silicon photodiodes as detectors, is described. The three mass and charge discriminating sensors based on the time of flight technique are also described.

Hovestadt, D.↗

REPRODUCTION OF THE OBSERVED TWO-COMPONENT MAGNETIC HELICITY IN SOLAR WIND TURBULENCE BY A SUPERPOSITION OF PARALLEL AND OBLIQUE ALFVEN WAVES

The angular distribution of the normalized reduced magnetic helicity density ({sigma} r{sub m}) in solar wind turbulence reveals two components of distinct polarity in different angle ranges. This kind of two-component {sigma}{sup r}{sub m} may indicate the possible wave modes and power spectral densities (PSDs) of the turbulent fluctuations. Here we model the measured angular distribution of {sigma}{sup r}{sub m} by assuming a PSD distribution for Alfven fluctuations in wavevector space, and then fit the model results to the observations by adjusting the pattern of the PSD distribution. It is found that the two-component form of the PSD, which has a major and minor component close to k and k{sub ||}, respectively, seems to be responsible for the observed two-component {sigma}{sup r}{sub m}. On the other hand, both an isotropic PSD and a PSD with only a single component bending toward k fail to reproduce the observations. Moreover, it is shown that the effect of gradual balance between outward and inward wave-energy fluxes with decreasing spatial scale needs to be considered in order to reproduce the observed diminishing of |{sigma}{sup r}{sub m}| at shorter scales. Therefore, we suggest that the observed two-component {sigma}{sup r}{sub m} in the solar wind turbulence may be due to a superposition of Alfven waves with quasi-perpendicular (major part) and quasi-parallel (minor part) propagation. The waves seem to become gradually balanced toward shorter scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian Structural Time Series for Behind-the-Meter Photovoltaic Disaggregation: Preprint

Distributed photovoltaic (PV) generation often occurs ``behind the meter": a grid operator can only observe the net load, which is the sum of the gross load and distributed PV generation. This lack of observability poses a challenge to system operation at both bulk level and distribution level. The lack of real-time or near-future disaggregated estimates of gross load and PV generation will lead to over scheduling of energy production and regulation reserves, reliability constraints violations, wear and tear of controller devices, and potentially cascading failures of a system. In this paper we propose the use of a Bayesian Structural Time Series (BSTS) model with local solar irradiance measurements to disaggregate the summed PV generation and gross load signals at a downstream measurement site. BSTSs are a highly expressive model class that blends classic time series models with the powerful Bayesian state space estimation framework. Disaggregation is done probabilistically, which automatically quantifies the uncertainties of the estimated PV generation and gross load consumption. Depending on the data availability in real-time, it can be used to disaggragate PV and gross load at customer site, or can be used at the feeder level. In this paper, we focus on solving the problem at feeder level. We compare the performance of a BSTS model as well as a handful of state-of-the-art methods on a Pecan Street AMI dataset, using the National Solar Radiation Database (NSRDB) to estimate local irradiance.

Bayesian structural time series↗