Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diode effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Vibrational testing of optical fiber connector joints

An experimental study was performed to determine the effects of vibration on the propagation of light through SMA- and ST-type fiber-optic connectors. A multimode, fiber-optic link was vibrated from 0 to 10,000 Hz at a constant peak acceleration along the connector transverse and longitudinal axes. All other environmental parameters were ambient. Transfer characteristics through the connection were examined as a function of vibrational frequency using both laser and light-emitting diode (LED) light to illuminate the system. Slight differences in operation between the SMA and ST connectors were observed with no appreciative attenuation as a result of vibration. Vibration did cause constant-amplitude input light to be modulated in the connector; however; the amplitude of vibration-induced noise was less than 3 standard deviations from the mean.

Sovie, Amy L.↗

Quad-Chip Double-Balanced Frequency Tripler

Solid-state frequency multipliers are used to produce tunable broadband sources at millimeter and submillimeter wavelengths. The maximum power produced by a single chip is limited by the electrical breakdown of the semiconductor and by the thermal management properties of the chip. The solution is to split the drive power to a frequency tripler using waveguides to divide the power among four chips, then recombine the output power from the four chips back into a single waveguide. To achieve this, a waveguide branchline quadrature hybrid coupler splits a 100-GHz input signal into two paths with a 90 relative phase shift. These two paths are split again by a pair of waveguide Y-junctions. The signals from the four outputs of the Y-junctions are tripled in frequency using balanced Schottky diode frequency triplers before being recombined with another pair of Y-junctions. A final waveguide branchline quadrature hybrid coupler completes the combination. Using four chips instead of one enables using four-times higher power input, and produces a nearly four-fold power output as compared to using a single chip. The phase shifts introduced by the quadrature hybrid couplers provide isolation for the input and output waveguides, effectively eliminating standing waves between it and surrounding components. This is accomplished without introducing the high losses and expense of ferrite isolators. A practical use of this technology is to drive local oscillators as was demonstrated around 300 GHz for a heterodyne spectrometer operating in the 2-3-THz band. Heterodyne spectroscopy in this frequency band is especially valuable for astrophysics due to the presence of a very large number of molecular spectral lines. Besides high-resolution radar and spectrographic screening applications, this technology could also be useful for laboratory spectroscopy.

Lin, Robert H.↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin C Tibere-Inglesse↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin Tibère-Inglesse↗

Electroluminescence from GeSn heterostructure pin diodes at the indirect to direct transition

The emission properties of GeSn heterostructure pin diodes have been investigated. The devices contain thick (400–600 nm) Ge{sub 1−y}Sn{sub y} i-layers spanning a broad compositional range below and above the crossover Sn concentration y{sub c} where the Ge{sub 1−y}Sn{sub y} alloy becomes a direct-gap material. These results are made possible by an optimized device architecture containing a single defected interface thereby mitigating the deleterious effects of mismatch-induced defects. The observed emission intensities as a function of composition show the contributions from two separate trends: an increase in direct gap emission as the Sn concentration is increased, as expected from the reduction and eventual reversal of the separation between the direct and indirect edges, and a parallel increase in non-radiative recombination when the mismatch strains between the structure components is partially relaxed by the generation of misfit dislocations. An estimation of recombination times based on the observed electroluminescence intensities is found to be strongly correlated with the reverse-bias dark current measured in the same devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding middle-point inductance's effect on switching transients for multi-chip SiC package design with P-cell/N-cell concept

Middle-point inductance L_middle can be introduced in power module designs with P-cell/N-cell concept. In this paper, the effect of middle-point inductance on switching transients is analyzed first using frequency domain analysis. Then a dedicated multiple-chips power module is fabricated with the capability of varying L_middle, and extensive switching tests are conducted to evaluate the device’s switching performance at different L_middle. Experiment results show that as L_middle changes, different voltage stresses are imposed on the active switch and anti-parallel diode. For lower MOSFET’s turn-off, as L_middle goes up, the maximum voltage of lower MOSFET increases; however, the maximum voltage of anti-parallel diode decreases significantly. In addition to voltage spikes, it is observed that the active MOSFET’s turn-on loss will decrease at higher values of L_middle while its turn-off loss will increase. Detailed analysis of this loss variation is presented. The analysis and experiment results will provide design guidelines for multiple-chips power module package design with P-cell/N-cell concept.

Yang, Fei↗

SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index

Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and plan quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.

60 APPLIED LIFE SCIENCES↗

The drift field model applied to the lithium-containing silicon solar cell

The drift field model used by Wolf (1963) to calculate the short-circuit current was extended to permit calculations of the open-circuit voltage and the maximum power under conditions of illumination of either tungsten (2800 C) source or air mass zero sunlight. Voltages were calculated using an expression for the drift field diode saturation current. The model, applied to the oxygen-rich (C-13 group) lithium solar cells, was used to calculate the pre- and post-electron bombardment trends of the open-circuit voltage, maximum power, and short-circuit current for lithium gradients in the range from 10 to the 18th power to 10 to the 19th power Li/cm to the 4th power. Diffusion length degradation and carrier removal effects were sufficient to predict the cell performance up to 3 x 10 to the 14th electrons per sq cm. Beyond this fluence it was necessary to include drift field removal effects.

Godlewski, M. P.↗

Spatial Combining of Laser-Diode Beams for Pumping an NPRO

A free-space optical beam combiner now undergoing development makes it possible to use the outputs of multiple multimode laser diodes to pump a neodymium-doped yttrium aluminum garnet (Nd:YAG) non-planar ring oscillator (NPRO) laser while ensuring that the laser operates at only a single desired frequency. Heretofore, a Nd:YAG NPRO like the present one has been pumped by a single multimode laser-diode beam delivered via an optical fiber. It would be desirable to use multiple pump laser diodes to increase reliability beyond that obtainable from a single pump laser diode. However, as explained in this article, simplistically coupling multiple multimode laser-diode beams through a fiber-optic combiner would entail a significant reduction in coupling efficiency, and lasing would occur at one or more other frequencies in addition to the single desired frequency. To minimize coupling loss, one must ensure that the NA (approximately equal to 0.3) of the combined laser-diode beams is less than the NA of the fiber. The A(Omega) of the laser-diode beam in the slow-axis plane is 1/1.3 as large as that of the fiber. This A(Omega) is small enough to enable efficient coupling of light into the optical fiber, but too large for combining of beams in the slow-axis plane. Therefore, a pair of cylindrical lenses is used to cancel the slow-axis plane magnification introduced by the on-cylindrical lenses used to effect magnification in the fast-axis plane.

Gelsinger, Paul↗

Electrical and optical properties of low-bandgap oxide Zn 2 Mo 3 O 8 for optoelectronic applications

Semiconducting metal oxides are attractive for various applications since most oxides are non-toxic, stable, and easy to deposit. Wide band-gap materials have been studied more extensively, compared to low bandgap materials, which introduces limitations to the applications of oxides. Study of low band-gap semiconducting oxides can propel the usage of oxides in a wider range of applications. The electronic, structural, and optical properties of Zn 2 Mo 3 O 8 (ZMO) are investigated. Stoichiometric polycrystalline films of ZMO are deposited using pulsed laser deposition system at room temperature. The unintentionally n-doped films show a hall electron mobility of 0.7 cm 2 V -1 s -1 and have a bandgap of 2.1 eV. The photoelectron spectra contain complex peak profiles which are explained to be a manifestation of final state effects. The orbital contribution to the valence band of ZMO is probed using resonant photoelectron spectroscopy, which confirms that the valence band is composed of Mo 4d levels. The conduction and valence band edges are predicted to be at 4.2 eV and 6.3 eV, so most of the conventional wide band-gap oxides can be used as hole-blocking layers with ZMO. Under A.M. 1.5 illumination, single-sided Schottky diode with Fluorine-doped tin oxide/TiO 2 /ZMO/Au structure shows no photovoltaic action, possibly due to high exciton binding energy and low carrier drift lengths. However, the Schottky device shows a higher current under illumination, which suggests that with improvement in carrier drift lengths, ZMO can find applications in low-cost optoelectronic devices on flexible substrates like plastic or Polyethylene terephthalate.

36 MATERIALS SCIENCE↗

A 32-channel photon counting module with embedded auto/cross-correlators for real-time parallel fluorescence correlation spectroscopy

Fluorescence correlation spectroscopy (FCS) is a well-established technique to study binding interactions or the diffusion of fluorescently labeled biomolecules in vitro and in vivo. Fast FCS experiments require parallel data acquisition and analysis which can be achieved by exploiting a multi-channel Single Photon Avalanche Diode (SPAD) array and a corresponding multi-input correlator. This paper reports a 32-channel FPGA based correlator able to perform 32 auto/cross-correlations simultaneously over a lag-time ranging from 10 ns up to 150 ms. The correlator is included in a 32 × 1 SPAD array module, providing a compact and flexible instrument for high throughput FCS experiments. However, some inherent features of SPAD arrays, namely afterpulsing and optical crosstalk effects, may introduce distortions in the measurement of auto- and cross-correlation functions. We investigated these limitations to assess their impact on the module and evaluate possible workarounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-459: Impact of Source Position and Traveling Time On HDR Skin Surface Applicator Dosimetry

Purpose: Observed dosimetric discrepancy between measured and treatment planning system (TPS) predicted values, during applicator commissioning, were traced to source position uncertainty in the applicator. We quantify the dosimetric impact of this geometric uncertainty, and of the source traveling time inside the applicator, and propose corrections for clinical use. Methods: We measured the dose profiles from the Varian Leipzig-style (horizontal) HDR skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter (OSLD) and three different GammaMed HDR afterloders. The dose profiles and depth dose of each aperture were measured at several depths (up to about 10 mm, depending on the dosimeter). The measured dose profiles were compared with Acuros calculated profiles in BrachyVision TPS. For the impact of the source position, EBT3 film measurements were performed with applicator, facing-down and facing-up orientations. The dose with and without source traveling was measured with diode detector using HDR timer and electrometer timer, respectively. Results: Depth doses measured using the three dosimeters were in good agreement, but were consistently higher than the Acuros dose calculations. Measurements with the applicator facing-up were significantly lower than those in the facing-down position with maximum difference of about 18% at the surface, due to source sag inside the applicator. Based on the inverse-square law, the effective source sag was evaluated to be about 0.5 mm from the planned position. The additional dose from the source traveling was about 2.8% for 30 seconds with 10 Ci source, decreasing with increased dwelling time and decreased source activity. Conclusion: Due to the short source-to-surface distance of the applicator, the small source sag inside the applicator has significant dosimetric impact, which should be considered before the clinical use of the applicator. Investigation of the effect for other applicators that have relatively large source lumen inner diameter may be warranted. Christopher Barker and Gil’ad Cohen are receiving research support for a study of skin surface brachytherapy from Elekta.

60 APPLIED LIFE SCIENCES↗

GaN MOCVD Growth on Native substrates for High Voltage (15-20 KV) Vertical Power Devices

This project aims to develop metalorganic chemical vapor deposition (MOCVD) homoepitaxy of GaN on native substrates with fast growth rate (15-20 μm/hr), low background doping (low-10 15 cm -3 ) and smooth surface morphology via comprehensive understanding of the crystal growth process including high quality GaN substrate development and surface preparation, impurity and native defects control, and their impacts on the breakdown field. The team successfully developed a new growth process by introducing the laser-assisted MOCVD (LA-MOCVD) process to address the limited growth rates of GaN in the traditional MOCVD process. Specifically, the use of the CO2 laser with lasing wavelength of 9.219 μm, the strong coupling between the laser beam with the ammonia (GaN MOCVD precursor) leads to efficient decomposition of NH3 which significantly increases the effective group V/III molar ratio and thus suppresses C impurity incorporation in MOCVD GaN. The reduction in C incorporation in LA-MOCVD GaN is especially prominent when the GaN growth rate is fast (> 10 μm/hr), which allows to develop thick GaN films with high crystalline quality and low controllable doping needed for vertical high power device applications. The results of this project lead to the demonstration of vertical GaN PN diodes with record breakdown voltage of ~ 8kV with high Baliga’s figure of merit.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 163 micron laser heterodyne radiometer for OH

A 163 micron (1.836 THz) radiometer developed for airplane and/or balloon platforms is described. The laser local oscillator is a CO2 pumped methanol laser operating at a frequency which is approx. 1 GHz from the J = 3/2 - 1/2 transition of OH. The laser is used directly as a local oscillator or is translated in frequency to closer coincidence with the OH emission, depending on achieved detector IF bandwidth. Frequency translation techniques which are described are diode mixing and a method of single sideband generation using an external Stark modulated gas cell. The photoconductive mixer used is a strained Ge crystal, doped with Ga, originally used as an incoherent detector. The uniaxial strain on the Ga doped Ge crystal shifts the threshold for photoconduction from 100/cm to frequencies as low as 50/cm. These detectors are currently being characterized as mixers in the laboratory. Of particular interest are the effect of local oscillator power and strain on IF, bandwidth detector impedance, and conversion loss. Preliminary results of these tests are described and compared with theorectical expectations.

Pickett, H. M.↗

Enhanced Light Extraction from OLEDs Fabricated on Patterned Plastic Substrates

A key scientific and technological challenge in organic light-emitting diodes (OLEDs) is enhancing the light outcoupling factor η out , which is typically <20%. This paper reports experimental and modeling results of a promising approach to strongly increase η out by fabricating OLEDs on novel flexible nanopatterned substrates that result in a >2× enhancement in green phosphorescent OLEDs (PhOLEDs) fabricated on corrugated polycarbonate (PC). The external quantum efficiency (EQE) reaches 50% (meaning ηout ≥50%); it increases 2.6x relative to a glass/ITO device and 2× relative to devices on glass/poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) or flat PC/PEDOT:PSS. A significant enhancement is also observed for blue PhOLEDs with EQE 1.7× relative to flat PC. The corrugated PC substrates are fabricated efficiently and cost-effectively by direct room-temperature molding. These substrates successfully reduce photon losses due to trapping/waveguiding in the organic+anode layers and possibly substrate, and losses to plasmons at the metal cathode. Focused ion beam gauged the conformality of the OLEDs. Dome-shaped convex nanopatterns with height of ~280–400 nm and pitch ~750–800 nm were found to be optimal. Lastly, substrate design and layer thickness simulations, reported first for patterned devices, agree with the experimental results that present a promising method to mitigate photon loss paths in OLEDs.

36 MATERIALS SCIENCE↗

Thermometry of an open spatially inhomogeneous flame by diode laser absorption spectroscopy

Features of a single-beam variant of diode laser absorption spectroscopy (DLAS) used for temperature measurements in a spatially inhomogeneous hot zone are studied. A flame temperature of a commercial burner is measured by using water molecule absorption lines. The flame is probed by a diode laser radiation at various heights and in various directions. The correctness of DLAS measurement results is verified by comparing DLAS data with temperatures measured by the method of coherent anti-Stokes scattering (CARS). It is shown that in homogeneous flame domains the temperatures obtained by both the methods coincide. Temperature inhomogeneity along the probe beam direction is a principal problem of DLAS, in which case the method yields information about some effective temperature along the light trace. The difference in data obtained by DLAS and CARS is estimated. In probing traces with temperature gradients the difference reaches 700 K. Possibilities of accounting for temperature inhomogeneities along the trace in DLAS measurements are discussed. A method of differential spectra is suggested, which in certain conditions can provide substantially better coincidence of results for the two methods. (laser spectroscopy)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Output calculation of electron therapy at extended SSD using an improved LBR method

Purpose: To calculate the output factor (OPF) of any irregularly shaped electron beam at extended SSD. Methods: Circular cutouts were prepared from 2.0 cm diameter to the maximum possible size for 15 × 15 applicator cone. In addition, two irregular cutouts were prepared. For each cutout, percentage depth dose (PDD) at the standard SSD and doses at different SSD values were measured using 6, 9, 12, and 16 MeV electron beam energies on a Varian 2100C LINAC and the distance at which the central axis electron fluence becomes independent of cutout size was determined. The measurements were repeated with an ELEKTA Synergy LINAC using 14 × 14 applicator cone and electron beam energies of 6, 9, 12, and 15 MeV. The PDD measurements were performed using a scanning system and two diodes—one for the signal and the other a stationary reference outside the tank. The doses of the circular cutouts at different SSDs were measured using PTW 0.125 cm{sup 3} Semiflex ion-chamber and EDR2 films. The electron fluence was measured using EDR2 films. Results: For each circular cutout, the lateral buildup ratio (LBR) was calculated from the measured PDD curve using the open applicator cone as the reference field. The effective SSD (SSD{sub eff}) of each circular cutout was calculated from the measured doses at different SSD values. Using the LBR value and the radius of the circular cutout, the corresponding lateral spread parameter [σ{sub R}(z)] was calculated. Taking the cutout size dependence of σ{sub R}(z) into account, the PDD curves of the irregularly shaped cutouts at the standard SSD were calculated. Using the calculated PDD curve of the irregularly shaped cutout along with the LBR and SSD{sub eff} values of the circular cutouts, the output factor of the irregularly shaped cutout at extended SSD was calculated. Finally, both the calculated PDD curves and output factor values were compared with the measured values. Conclusions: The improved LBR method has been generalized to calculate the output factor of electron therapy at extended SSD. The percentage difference between the calculated and the measured output factors of irregularly shaped cutouts in a clinical useful SSD region was within 2%. Similar results were obtained for all available electron energies of both Varian 2100C and ELEKTA Synergy machines.

07 ISOTOPE AND RADIATION SOURCES↗