Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data reduction methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Block encoding of the three-dimensional heterogeneous Poisson equation with application to fracture flow

Quantum linear system (QLS) algorithms offer the potential to solve large-scale linear systems exponentially faster than classical methods. However, applying QLS algorithms to real-world problems remains challenging due to issues such as state preparation, data loading, and efficient information extraction. In this work, we study the feasibility of applying QLS algorithms to solve discretized three-dimensional (3D) heterogeneous Poisson equations, with specific examples relating to groundwater flow through geologic fracture networks. We explicitly construct a block encoding for the 3D heterogeneous Poisson matrix by leveraging the sparse local structure of the discretized operator. While classical solvers benefit from preconditioning, we show that block encoding the system matrix and preconditioner separately does not improve the effective condition number that dominates the QLS run-time. This differs from classical approaches where the preconditioner and the system matrix can often be implemented independently. Nevertheless, due to the structure of the problem in three dimensions, the quantum algorithm achieves a run-time of 𝑂⁡(𝑁 2/3 polylog 𝑁 ⋅log (1/𝜖)), outperforming the best classical methods (with run times of 𝑂⁡(𝑁⁢log 𝑁 ⋅log (1/𝜖))) and offering exponential memory savings. These results highlight both the promise and limitations of QLS algorithms for practical scientific computing, and point to effective condition-number reduction as a key barrier in achieving quantum advantages.

58 GEOSCIENCES↗

SU-E-J-207: Effect of Pulse Sequence Parameters On Geometric Distortions Induced by a Titanium Brachytherapy Applicator

Purpose: To investigate the effect of readout bandwidth and voxel size on the appearance of distortion artifacts caused by a titanium brachytherapy applicator. Methods: An acrylic phantom was constructed to rigidly hold a MR conditional, titanium Fletcher-Suit-Delclos-style applicator set (Varian Medical Systems) for imaging on CT (Philips Brilliance) and 1.5T MRI (Siemens Magnetom Aera). Several variants of MRI parameters were tried for 2D T2-weighted turbo spin echo imaging in comparison against the standard clinical protocol with the criteria to keep relative SNR loss less than 20% and imaging time as short as possible. Two 3D sequences were also used for comparison with similar parameters. The applicator tandem was segmented on axial CT images (0.4×0.4×1.5mm {sup 3} resolution) and the CT images were registered to the 3D MR images in Eclipse (Varian). The applicator volume was then overlaid on all MRI sets in 3D-Slicer and distances were measured from the tandem tip to the MRI artifact edge in right/left/superior and anterior/posterior/superior directions from coronal and sagittal 2D acquisitions, respectively, or 3D data reformats. Artifact regions were also manually contoured in coronal/sagittal orientations for area measurements. Results: As would be expected, reductions in voxel size and increases in readout bandwidth reduced artifact size (average max artifact length decreased by 0.95 mm and average max area decrease by 0.27 cm{sup 2}). Interestingly, bandwidth increases yielded reductions in area (0.19 cm{sup 2}) and in distance measurements (1 mm) even with voxel increases, as compared to a standard protocol. This could be useful when high performance protocols are not feasible due to long imaging times. Conclusion: We have characterized artifacts caused by cervical brachytherapy applicator across multiple sequence parameters at 1.5T. Future work will focus on finalizing an optimal protocol that balances artifact reduction with imaging time and then testing this new protocol in patients.

60 APPLIED LIFE SCIENCES↗

Clinical introduction of image lag correction for a cone beam CT system

Purpose: Image lag in the flat-panel detector used for Linac integrated cone beam computed tomography (CBCT) has a degrading effect on CBCT image quality. The most prominent visible artifact is the presence of bright semicircular structure in the transverse view of the scans, known also as radar artifact. Several correction strategies have been proposed, but until now the clinical introduction of such corrections remains unreported. In November 2013, the authors have clinically implemented a previously proposed image lag correction on all of their machines at their main site in Amsterdam. The purpose of this study was to retrospectively evaluate the effect of the correction on the quality of CBCT images and evaluate the required calibration frequency. Methods: Image lag was measured in five clinical CBCT systems (Elekta Synergy 4.6) using an in-house developed beam interrupting device that stops the x-ray beam midway through the data acquisition of an unattenuated beam for calibration. A triple exponential falling edge response was fitted to the measured data and used to correct image lag from projection images with an infinite response. This filter, including an extrapolation for saturated pixels, was incorporated in the authors’ in-house developed clinical CBCT reconstruction software. To investigate the short-term stability of the lag and associated parameters, a series of five image lag measurement over a period of three months was performed. For quantitative analysis, the authors have retrospectively selected ten patients treated in the pelvic region. The apparent contrast was quantified in polar coordinates for scans reconstructed using the parameters obtained from different dates with and without saturation handling. Results: Visually, the radar artifact was minimal in scans reconstructed using image lag correction especially when saturation handling was used. In patient imaging, there was a significant reduction of the apparent contrast from 43 ± 16.7 to 15.5 ± 11.9 HU without the saturation handling and to 9.6 ± 12.1 HU with the saturation handling, depending on the date of the calibration. The image lag correction parameters were stable over a period of 3 months. The computational load was increased by approximately 10%, not endangering the fast in-line reconstruction. Conclusions: The lag correction was successfully implemented clinically and removed most image lag artifacts thus improving the image quality. Image lag correction parameters were stable for 3 months indicating low frequency of calibration requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Breast Cancer Found Incidentally After Reduction Mammaplasty in Young Insured Women

Background: Reduction mammaplasty is a common operation performed for healthy women. The estimated incidence of breast cancer diagnosed at the time of reduction mammaplasty varies from 0.06 to 4.5%, and information on the care of these patients is limited. This study aimed to determine the incidence of breast cancer identified incidentally during reduction mammaplasty and to characterize preoperative imaging. Methods: Women 18 years of age or older who underwent reduction mammaplasty from 2013 to 2015 were identified from the Truven Health MarketScan{sup ®} Research Databases. Patients with prior breast cancer were excluded. Descriptive statistics were calculated for patient characteristics, incidental breast cancer, preoperative breast imaging, and postoperative treatment. Results: Reduction mammaplasty was performed for 18,969 women with a mean age of 42.5 years. Of these patients, 186 (0.98%) were incidentally found to have breast cancer, with 134 (0.71%) having invasive breast cancer and 52 (0.27%) having carcinoma in situ. The patients with incidentally found cancer were older than the patients without cancer (50.8 vs. 42.5 years; p < 0.001). Overall, 58.2% of the patients had undergone mammography before reduction mammoplasty. The rates were higher (> 80%) for the patients older than 40 years. Preoperative mammography was performed for 76.3% of those with a diagnosis of breast cancer at time of reduction mammoplasty. Conclusions: Breast cancer diagnosed incidentally at the time of reduction mammaplasty is uncommon and often radiographically occult. The majority of women older than 50 years appropriately received preoperative mammography. These data can be used to manage patient expectations about the potential for the incidental diagnosis of breast cancer at reduction mammaplasty, even with a negative preoperative mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MCNPX Improvements for Threat Reduction Applications

Enhancements contained in the current MCNPX 2.6.0 Radiation Safety Information Computational Center (RSICC) release will be presented, including stopped-muon physics, delayed neutron and photon generation, and automatic generation of source photons. Preliminary benchmarking comparisons with data taken with a muon beam at the Paul Scherrer Institute Spallation Neutron Source accelerator will be discussed. We will also describe current improvements now underway, including Nuclear Resonance Fluorescence (NRF), pulsed sources, and others. We will also describe very new work begun on a threat-reduction (TR) user interface, designed to simplify the setup of TR-related calculations, and introduce standards into geometry, sources and backgrounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis shear wave velocity structure obtained from surface wave methods in Bornova, Izmir

Properties of the soil from the bedrock is necessary to describe accurately and reliably for the reduction of earthquake damage. Because seismic waves change their amplitude and frequency content owing to acoustic impedance difference between soil and bedrock. Firstly, shear wave velocity and depth information of layers on bedrock is needed to detect this changing. Shear wave velocity can be obtained using inversion of Rayleigh wave dispersion curves obtained from surface wave methods (MASW- the Multichannel Analysis of Surface Waves, ReMi-Refraction Microtremor, SPAC-Spatial Autocorrelation). While research depth is limeted in active source study, a passive source methods are utilized for deep depth which is not reached using active source methods. ReMi method is used to determine layer thickness and velocity up to 100 m using seismic refraction measurement systems.The research carried out up to desired depth depending on radius using SPAC which is utilized easily in conditions that district using of seismic studies in the city. Vs profiles which are required to calculate deformations in under static and dynamic loads can be obtained with high resolution using combining rayleigh wave dispersion curve obtained from active and passive source methods. In the this study, Surface waves data were collected using the measurements of MASW, ReMi and SPAC at the İzmir Bornova region. Dispersion curves obtained from surface wave methods were combined in wide frequency band and Vs-depth profiles were obtained using inversion. Reliability of the resulting soil profiles were provided by comparison with theoretical transfer function obtained from soil paremeters and observed soil transfer function from Nakamura technique and by examination of fitting between these functions. Vs values are changed between 200-830 m/s and engineering bedrock (Vs>760 m/s) depth is approximately 150 m.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NDCS Group Meeting Work overview: NCSP Task ORNL IP&D-5 [Slides]

The presentation discusses the primary goal of the NCSP Task IP&D-5 which is to use available data from HPRR operation to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The presentation elaborates on the HPRR operation and how it relates to the KENO VI model, sulfur pellets measurements, and calculation methodology between KENO and MAVRIC FW-CADIS. The presentation concludes by stating that some work is still needed to evaluate uncertainties and to explain the discrepancy computation/experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation of polyethylene glycol and calcium-mediated membrane fusion

We report on the mechanism of membrane fusion mediated by polyethylene glycol (PEG) and Ca{sup 2+} by means of a coarse-grained molecular dynamics simulation approach. Our data provide a detailed view on the role of cations and polymer in modulating the interaction between negatively charged apposed membranes. The PEG chains cause a reduction of the inter-lamellar distance and cause an increase in concentration of divalent cations. When thermally driven fluctuations bring the membranes at close contact, a switch from cis to trans Ca{sup 2+}-lipid complexes stabilizes a focal contact acting as a nucleation site for further expansion of the adhesion region. Flipping of lipid tails induces subsequent stalk formation. Together, our results provide a molecular explanation for the synergistic effect of Ca{sup 2+} and PEG on membrane fusion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Life-Cycle Analysis in Support of Clean Hydrogen Production

Hydrogen is a basic molecule which is commonly used in the production of chemicals or as an energy carrier or a fuel. Its zero-carbon content means that it does not produce carbon dioxide upon its use. However, depending on the energy source and technology for hydrogen production and delivery, there can be greenhouse gas (GHG) emissions associated with the hydrogen for various end use applications. To provide the largest reduction in GHG emissions, hydrogen produced from clean energy sources should be used. As concerns regarding climate change grows, there is an increasing focus on economic production of clean hydrogen to displace less climate neutral sources of hydrogen. However, there are many different methods of hydrogen production with unique processes that result in different levels of life cycle GHG emissions of hydrogen production and its end use applications. Therefore, a comprehensive life cycle accounting methodology that takes all these factors into account is required. he GREET ® (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model was first developed in 1995 by Argonne National Laboratory with the support from the various offices of the U.S. Department of Energy (DOE). GREET provides in-depth Life Cycle Analysis (LCA) simulations for a variety of products and is available as an Excel spreadsheet (GREET Excel), or as an application (GREET .Net). Both versions are available for public download at no cost. This report accompanies GREET 2022 release to describe the major updates and expansions to the hydrogen technology pathways, and to provide data sources and sample carbon intensity results for each of the pathways.

08 HYDROGEN↗

Environmental Remediation Activities in Japan Following the Fukushima Dai-ichi Reactor Incident - 12603

In March 2011, the Fukushima Dai-ichi reactor power plant was crippled by the Great Pacific earthquake and subsequent tsunami. Much of the focus in the news was on the reactor site itself as the utility company (TEPCO), the Japanese government, and experts from around the world worked to bring the damaged plants into a safe shutdown condition and stem the release of radioactivity to the environment. Most of the radioactivity released was carried out to sea with the prevailing winds. Still, as weather patterns changed and winds shifted, a significant plume of radioactive materials released from the plant deposited in the environment surrounding the plant, contaminating large land areas of the Fukushima Prefecture. The magnitude of the radiological impact to the surrounding environmental is so large that the Japanese government has had to reevaluate the meaning of 'acceptably clean'. In many respects, 'acceptably clean' cannot be a one-size-fits-all standard. The economics costs of such an approach would make impossible what is already an enormous and costly environmental response and remediation task. Thus, the Japanese government has embarked upon an approach that is both situation-specific and reasonably achievable. For example, the determination of acceptably clean for a nursery school or kindergarten play yard may be different from that for a parking lot. The acceptably clean level of residual radioactivity in the surface soil of a rice paddy is different from that in a forested area. The recognized exposure situation (scenario) thus plays a large role in the decision process. While sometimes complicated to grasp or implement, such an approach does prioritize national resources to address environment remediation based upon immediate and significant risks. In addition, the Japanese government is testing means and methods, including advanced or promising technologies, that could be proven to be effective in reducing the amount of radioactivity in the environment beyond a fixed, concentration based limit. Essentially, the definition of acceptably clean includes the concept of reasonably achievable, given the available technology, means and methods, and the cost to implement such. The Japanese government recently issued three technology demonstration contracts expressly designed to test and evaluate the available technologies, means, and methods, which, if implemented, might produce the greatest risk reduction from environmental contamination for the best value. One of the Japanese contract holders, Obayashi JV, has teamed with AMEC to demonstrate the applicability and capabilities of the Orion ScanPlot{sup SM} and ScanSort{sup SM} technologies in radiologically impacted towns both inside and immediately outside the 20 km restricted zone. This presentation provides some unique images and informative insight into the environmental radioactive impacts in and around the exclusion zone. It will provide a look at one element of the Japanese government?s efforts to achieve the greatest risk reduction that is reasonably achievable. The Orion ScanPlot{sup SM} and ScanSort{sup SM} are being used with success on the Japan Town Demonstration Project to assess pre-remedial action contamination levels, document the post-remedial action contamination levels and to precisely measure and segregate excavated soils based on their radioactive content and the prescribed segregation limits (DCS). Initial results suggest that these technologies could provide capabilities to the remedial action efforts that would result in considerable improvements in field data certainty and compliance with remedial objectives while reducing overall costs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-G-TeP1-11: Predictors of Cardiac and Lung Dose Sparing in DIBH for Left Breast Treatment

Purpose: This retrospective study of left sided whole breast radiation therapy (RT) patients investigates possible predictive parameters correlating to cardiac and left lung dose sparing by deep inspiration breath-hold (DIBH) technique compared to free-breathing (FB). Methods: Thirty-one patients having both DIBH and FB CT scans were included in the study. All patients were planned with a standard step-and-shoot tangential technique using MV photons, with prescription of 50Gy or 50.4Gy. The displacement of the breath hold sternal mark during DIBH, the cardiac contact distances of the axial (CCDax) and parasagittal (CCDps) planes, and lateral-heart-to-chest (LHC) distance on FB CT scans were measured. Lung volumes, mean dose and dose-volume histograms (V5, V10 and V20) were analyzed and compared for heart and left lung for both FB and DIBH techniques. Correlation analysis was performed to identify the predictors for heart and left lung dose sparing. Two-tailed Student’s t-test and linear regression were used for data analysis with significance level of P≤0.05. Results: All dosimetric metrics for the heart and left lung were significantly reduced (P<0.01) with DIBH. Breath hold sternal mark displacement ranged from 0.4–1.8 cm and correlated with mean (P=0.05) and V5 (P=0.02) of heart dose reduction by DIBH. FB lung volume showed correlation with mean lung dose reduction by DIBH (P<0.01). The FB-CCDps and FB-LHC distance had strong positive and negative correlation with FB mean heart dose (P<0.01) and mean heart dose reduction by DIBH (P<0.01), respectively. FB-CCDax showed no correlation with dosimetric changes. Conclusion: DIBH technique has been shown to reduce dose to the heart and left lung. In this patient cohort, FB-CCDps, FB-LHC distance, and FB lung volume served as significant predictors for heart and left lung. These parameters can be further investigated to be used as a tool to better select patients who will benefit from DIBH.

60 APPLIED LIFE SCIENCES↗

Biased deposition of Nb-ON-Cu for SRF accelerators, Final Report

The Phase I project objectives were: Task 1: Design, assemble, and commission a new coating facility that uses the RF cavity as the vacuum chamber Task 3: Coat and RF test biased Cu cavity Task 4: Evaluate test results and prepare Ph-II bid. As for project accomplishments, AASC has completed all of the tasks of Ph-I. However, for Task 2, we found a limit to the bias voltage on a substrate placed at the radius of the beam pipe. A bias voltage higher than -50 V can induce arcing from the substrate to the grounded anode. Arc spots form on the substrate and damage the film. The main problem addressed by this SBIR project is that the price of niobium dominates the cost of superconducting RF cavity production. The most effective route to significant cost reduction is to use cavities that have a thin layer of niobium deposited on a less expensive substrate. However, all attempts to use thin films of niobium in superconducting RF cavities have to date resulted in cavity performance that does not meet the requirements of modern linear accelerators. Alameda Applied Sciences Corporation (AASC) has developed a novel deposition method that can produce high-purity films of niobium. For superconducting radio-frequency (SRF) accelerator cavities, films of niobium on another base material could provide good performance at lower cost than for bulk niobium. The primary goal of all thin film coated approaches must be to demonstrate RF performance that matches that of bulk Nb cavities. This Ph-I was not expected to accomplish this major milestone for thin film coated SRF cavities in just 9 months with limited resources. We set less ambitious goals of demonstrating that using our CED process to coat a biased substrate could result in an increase of RF performance over previous tests with no applied bias voltage. In this Ph-1, we obtained preliminary RF data from Nb coated biased cavity structures so as to move ahead in Ph-II to demonstration of performance that approaches that of bulk Nb. Our task has been made more daunting recently as several labs (Fermilab, Cornell, and JLab) have demonstrated significantly improved performance of bulk Nb cavities using nitrogen doping and rapid cool-down techniques. The bar has just been raised for thin films. At the 2013 SRF thin film workshop held at INFN in Padua Italy, leading scientists from the LHC tossed a gauntlet to the thin film community. The LHC plans a high luminosity upgrade starting in about 4 years. Upper management at CERN has stated that they would prefer not to use bulk Nb for the upgrade, which will require hundreds of new SRF cavities. But the thin film community has a short window in which to demonstrate that a Cu (or Al) cavity that is coated with Nb delivers the kind of performance that we have come to expect from bulk Nb: Q o >10 10 that stays flat up to 20 MV/m or higher, good statistics from multiple cavities and reliable operation over thousands of hours. Breakthroughs are needed to meet these daunting goals. AASC has persisted with this challenge for more than five years now, with the benefit of DOE SBIR funding. We aim to preserve our momentum and build upon our base to try to reach the lofty goals within four more years.

36 MATERIALS SCIENCE↗

Streamlining and Transparently Automating Complex Waste Determinations at Los Alamos National Laboratory - 17286

Environmental programs at Los Alamos National Laboratory (LANL) generate a large amount of sampling activities that can result in waste that needs to be characterized and properly disposed. Since 2011, sampling results are managed in the cloud-based Environmental Information Management (EIM) database, which contains over 16 million current and historical data records. In many cases, the database's analytical records are used to characterize and dispose waste from environmental operations. Three factors contribute to streamlining of the waste disposition operations: (1) if possible, use of the existing analytical data for waste characterization to avoid additional laboratory analysis; (2) reduction in time spent on data evaluation for various waste acceptance criteria; and (3) choice of the proper and least expensive disposal alternative. Use of the existing analytical data, when allowed by law, creates some paradoxical problems: when chemical analysis is requested with the purpose of characterizing waste, it creates only 100 to 400 analytical records. However, use of exiting analytical data at LANL may lead to evaluation of tens of thousands of analytical records, with many records for each single analyte. This occurs because data were collected for environmental characterization and not waste characterization. To streamline data analysis for waste disposition using existing data, LANL has created a Waste Data Summary (WDS) module in the site's EIM database. Recognizing that waste determination is performed by groups outside the environmental program at LANL, the WDS allows for logically guided data selection for a specific waste determination (solids, liquids, radiological, etc.) and reduces potentially thousands of rows of data into simple formatted data reports that are easy to comprehend and process. This allows the waste evaluators to review data using multiple approaches to make their own determination on the most appropriate disposal method. There are four basic principles of WDS operation: (1) The highest detected analytical result is evaluated for the selected samples (or the lowest undetected result if there are no detected results); (2) All approved disposal pathways are evaluated; (3) Any failures of the Waste Acceptance Criteria are visibly highlighted to focus the attention of the evaluator; and (4) The decision of the disposal path is left to the trained waste evaluator (WDS does not choose or suggest any disposal paths). The summary results are presented as the set of short data reports. These reports can be divided into two groups: general comparison reports and disposal pathway specific forms. The general comparison forms show all Resource Conservation and Recovery Act (RCRA) analytes with pass/fail evaluation and with preference for toxicity characteristic leaching procedure (TCLP) results (or 20x rule) for solid samples, the potential RCRA hazard codes assignment for detected analytes, and all rad results. The detected chemical and radioactivity results are compared to the background values and to Soil Screening and Soil Action limits (SSL/SAL limits). Disposal pathway specific forms follow Waste Acceptance Criteria requirements for all disposal pathways available at LANL. The programming of the WDS tries to maximize existing data by analyte substitutions (like using gross alpha for necessary alpha emitting isotopes) or by making calculations when analytical results do not agree with legal requirements (like total chlordane in the RCRA regulations, which is most often analyzed and reported as individual isomers). All forms may be annotated by the waste evaluator to provide additional information to support decision making. Upon final decision of a disposal path, the complete dataset used in the evaluation and the WDS forms with annotations is 'frozen' as an un-editable PDF export to document the data used in the waste disposal determination. The streamlined process results in less work for waste evaluators and reduces overall labor and analytical costs. By comparison, a full review of a 10,000 record parent dataset may take a waste evaluator over a week to review, whereas with the WDS module, the task can be accomplished in less than one hour with clear, reproducible results. These results can be reviewed and checked at any time by quality assurance personnel, thus ensuring transparency in the decision making process. LANL believes this approach has broad applicability to other sites where waste determination is based on review of existing data collected for more generalized environmental purposes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Accelerated Clip Algorithm for Unstructured Meshes: A Batch-Driven Approach

The clip technique is a popular method for visualizing complex structures and phenomena within 3D unstructured meshes. Meshes can be clipped by specifying a scalar isovalue to produce an output unstructured mesh with its external surface as the isovalue. Similar to isocontouring, the clipping process relies on scalar data associated with the mesh points, including scalar data generated by implicit functions such as planes, boxes, and spheres, which facilitates the visualization of results interior to the grid. In this paper, we introduce a novel batch-driven parallel algorithm based on a sequential clip algorithm designed for high-quality results in partial volume extraction. Our algorithm comprises five passes, each progressively processing data to generate the resulting clipped unstructured mesh. The novelty lies in the use of fixed-size batches of points and cells, which enable rapid workload trimming and parallel processing, leading to a significantly improved memory footprint and run-time performance compared to the original version. On a 32-core CPU, the proposed batch-driven parallel algorithm demonstrates a run-time speed-up of up to 32.6x and a memory footprint reduction of up to 4.37x compared to the existing sequential algorithm. The software is currently available under an open-source license in the VTK visualization system.

Tsalikis, Spiros↗

Robust estimation of charge carrier diffusivity using transient photoluminescence microscopy

Transient microscopy has emerged as a powerful tool for imaging the diffusion of excitons and free charge carriers in optoelectronic materials. In many excitonic materials, extraction of diffusion coefficients can be simplified because of the linear relationship between signal intensity and local excited state population. However, in materials where transport is dominated by free charge carriers, extracting diffusivities accurately from multidimensional data is complicated by the nonlinear dependence of the measured signal on the local charge carrier density. To obtain accurate estimates of charge carrier diffusivity from transient microscopy data, statistically robust fitting algorithms coupled to efficient 3D numerical solvers that faithfully relate local carrier dynamics to raw experimental measurables are sometimes needed. Here, we provide a detailed numerical framework for modeling the spatiotemporal dynamics of free charge carriers in bulk semiconductors with significant solving speed reduction and for simulating the corresponding transient photoluminescence microscopy data. To demonstrate the utility of this approach, we apply a fitting algorithm using a Markov chain Monte Carlo sampler to experimental data on bulk CdS and methylammonium lead bromide (MAPbBr 3 ) crystals. Parameter analyses reveal that transient photoluminescence microscopy can be used to obtain robust estimates of charge carrier diffusivities in optoelectronic materials of interest, but that other experimental approaches should be used for obtaining carrier recombination constants. Additionally, simplifications can be made to the fitting model depending on the experimental conditions and material systems studied. Our open-source simulation code and fitting algorithm are made freely available to the scientific community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A unified RANS–LES model: Computational development, accuracy and cost

Large eddy simulation (LES) is computationally extremely expensive for the investigation of wall-bounded turbulent flows at high Reynolds numbers. A way to reduce the computational cost of LES by orders of magnitude is to combine LES equations with Reynolds-averaged Navier–Stokes (RANS) equations used in the near-wall region. A large variety of such hybrid RANS–LES methods are currently in use such that there is the question of which hybrid RANS-LES method represents the optimal approach. The properties of an optimal hybrid RANS–LES model are formulated here by taking reference to fundamental properties of fluid flow equations. It is shown that unified RANS–LES models derived from an underlying stochastic turbulence model have the properties of optimal hybrid RANS–LES models. The rest of the paper is organized in two parts. First, a priori and a posteriori analyses of channel flow data are used to find the optimal computational formulation of the theoretically derived unified RANS–LES model and to show that this computational model, which is referred to as linear unified model (LUM), does also have all the properties of an optimal hybrid RANS–LES model. Second, a posteriori analyses of channel flow data are used to study the accuracy and cost features of the LUM. The following conclusions are obtained. (i) Compared to RANS, which require evidence for their predictions, the LUM has the significant advantage that the quality of predictions is relatively independent of the RANS model applied. (ii) Compared to LES, the significant advantage of the LUM is a cost reduction of high-Reynolds number simulations by a factor of 0.07Re{sup 0.46}. For coarse grids, the LUM has a significant accuracy advantage over corresponding LES. (iii) Compared to other usually applied hybrid RANS–LES models, it is shown that the LUM provides significantly improved predictions.

97 MATHEMATICS AND COMPUTING↗

Theoretical analysis of the sequential proton-coupled electron transfer mechanisms for H2 oxidation and production pathways catalyzed by nickel molecular electrocatalysts

The design of electrocatalysts for the oxidation and production of H2 is important for the development of alternative energy sources. This paper focuses on the electrocatalysts, where denotes 1,5-diaza-3,7-diphosphacyclooctane ligands with substituent groups R and R' covalently bound to the phosphorus and nitrogen atoms, respectively. Theoretical methods are used to investigate the mechanism of the step in the catalytic cycle corresponding to – e– → for H2 oxidation and the reverse reaction for H2 production. This step involves electron transfer (ET) between the Ni complex and the electrode as well as proton transfer (PT) between the Ni and the N. The sequential mechanisms, PT–ET and ET–PT, are investigated for the following (R,R’) substituents: (Me,Me), (Ph,Ph), and (Ph,Bz), where Me, Ph, and Bz denote methyl, phenyl, and benzyl substituents. Density functional theory is used to calculate reduction potentials, pKas, and PT pathways, and Marcus theory is used to describe the electrochemical electron transfer, including the effects of solute and solvent reorganization energies. For the (Ph,Ph) and (Ph,Bz) systems, the sequential PT–ET mechanism would require surmounting a large free energy barrier for the initial PT step, followed by thermodynamically favorable or thermoneutral ET. The sequential ET–PT mechanism for these systems would require a relatively large initial applied overpotential, followed by a PT reaction with a relatively low free energy barrier. Consistent with experimental data, the calculated overpotential required for the initial reduction in the ET–PT mechanism is lower for the (Ph,Bz) system than for the (Ph,Ph) system. The concerted mechanism, in which the electron and proton transfer simultaneously without a stable intermediate, may be thermodynamically favorable and is a direction of future research. This material is based upon work supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the US Department of Energy, Office of Science, Office of Basic Energy Sciences under FWP56073.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerating Asymptotically Exact MCMC for Computationally Intensive Models via Local Approximations

We construct a new framework for accelerating Markov chain Monte Carlo in posterior sampling problems where standard methods are limited by the computational cost of the likelihood, or of numerical models embedded therein. Our approach introduces local approximations of these models into the Metropolis–Hastings kernel, borrowing ideas from deterministic approximation theory, optimization, and experimental design. Previous efforts at integrating approximate models into inference typically sacrifice either the sampler’s exactness or efficiency; our work seeks to address these limitations by exploiting useful convergence characteristics of local approximations. We prove the ergodicity of our approximate Markov chain, showing that it samples asymptotically from the exact posterior distribution of interest. We describe variations of the algorithm that employ either local polynomial approximations or local Gaussian process regressors. Our theoretical results reinforce the key observation underlying this article: when the likelihood has some local regularity, the number of model evaluations per Markov chain Monte Carlo (MCMC) step can be greatly reduced without biasing the Monte Carlo average. Numerical experiments demonstrate multiple order-of-magnitude reductions in the number of forward model evaluations used in representative ordinary differential equation (ODE) and partial differential equation (PDE) inference problems, with both synthetic and real data. Supplementary materials for this article are available online.

97 MATHEMATICS AND COMPUTING↗