Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data quality assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Understanding and Utilizing PBL Height Data from Multiple Observing Systems in the GEOS System

The accuracy of PBL height simulation is a key issue in many applications including forecasting near surface meteorology and air quality, however, it is a very challenging problem due to the lack of not only comprehensive, global Planetary Boundary Layer (PBL) observations but also a strategy and infrastructure to utilize PBL height data from a variety of sensors. Following the designation of PBL as an incubation class observable in the 2017 Decadal Survey, the PBL Incubation Study Team Report [14] made clear that “a future global PBL observing system requires modeling and data assimilation as essential components.” There is an urgent need for global modeling development in order to utilize Program of Record (POR) observations, assess their impacts, and identify gaps to be filled by future PBL missions. Our overall objective is to develop PBL data assimilation capabilities in the NASA Global Earth Observing System (GEOS), focusing on PBL height from multiple observing systems, to support the assessment and use of future PBL observations. The NASA GEOS system is composed of the GEOS global atmospheric general circulation model (AGCM) and the atmospheric data assimilation system (ADAS). The PBL parameterizations include the “Lock” K-profile scheme driven by surface and cloud-top buoyancy fluxes ([4]), and the “Louis” local scheme for stable conditions based on the Richardson number ([5]). Above the mixed layer defined by the Lock surface plume, shallow cumulus convection is represented by the mass flux scheme of [9]. Additional parameterizations are summarized in [1]. The ADAS employs the hybrid 4D Ensemble- Variational (EnVar) configuration ([15]), with the ensemble providing flow-dependent background error covariance information. The resultant analysis increments are fed back to the forecast model through the 4D incremental analysis update (IAU) approach ([11]). In this study, PBL height data are being or have been generated from radiosondes, GNSS RO, satellite (CATS, CALIPSO and ICESat-2) and ground-based (MPLNET) lidars, and wind profiler. Investigations have been conducted to specify quality marks for PBL height retrievals for the data assimilation purpose. These PBL height data have different strengths and weaknesses ([2], [3], [6], [7], [8], [10]), and the satellite PBL height data provide better global coverage and complement in-situ PBL height data. Radiosondes offer high accuracy and in situ measurement of temperature and humidity profiles, but with poor spatio-temporal sampling. The in-situ observing systems like MPLNET and wind profiler provide long history of PBL height records at each station. The GNSS RO based PBL height is retrieved based on the sharp gradients in refractivity profile that represent the fine vertical structure of temperature and moisture changes above the PBL. However, not all RO refractivity profiles reach the surface depending on location and regime, and RO refractivity retrievals can be negatively biased below 2km. The PBL height data from satellite lidars provide high resolution along track PBL height retrievals, but over land they are affected by previous day convective PBL aerosol and strongly associated with mixing layer and retrievals cannot be made below thick, attenuating clouds. A successful assimilation of PBL height data requires a thorough understanding of the observing method and the retrieval algorithm for each observing system in order to use the PBL height data from multiple observing systems properly. Due to the sensitivity of PBL height data to the observing method and choice of algorithm, it is important to use a model definition appropriate for each observation type to compute differences between PBL height data and model PBL height (OmFs). The GEOS model currently includes two PBL height definitions suitable for direct comparison with observed PBL height, and additional definitions are being added in this study. Evaluation of different model PBL height definitions is underway. Meanwhile, efforts have been made in the GEOS data assimilation system to develop PBL height data assimilation capability. PBL height data can be assimilated using two different approaches. The traditional approach is to construct an observation operator and its tangent linear and adjoint, which link control variables to PBL height data from each observing system. This observation operator can be very complicated, e.g., the lidar-based PBL height observation operator includes the backscatter lidar forward observation operator, the algorithm to derive PBL height from attenuated total backscatter, interpolation, and calculations handling the mismatch between observed and model scales. The other approach is to augment PBL height to the control variable vector, and it is adopted in this study. The latter approach was also used in previous studies, e.g., the assimilation of PBL height data from radiosonde and aircraft in the Real Time Mesoscale Analysis (RTMA) system for a dispersion modelling study ([13]); the PBL height assimilation study using lidar PBL height data at Greensburg, Kansas for a field campaign ([12]). The PBL height assimilation from multiple observing systems in this study allows us to take advantage of the diverse PBL height data that provide much better global coverage collectively under different meteorological conditions and with different temporal and spatial scales. As all the PBL heights are tightly coupled with the PBL thermodynamic variables, the strong correlations, which are provided by the 4D ensemble forecast, enable PBL height data from various sources to interact and combine coherently and provide additional information for PBL temperature and moisture fields. The results of comparisons among PBL height data from different sources and the evaluation of the model PBL height definitions with the PBL height data will be presented, and the PBL height data synergy strategies and preliminary results will also be discussed at the conference.

Y. Zhu↗

Corrective Action Decision Document/Corrective Action Plan for Corrective Action Unit 573: Alpha Contaminated Sites Nevada National Security Site, Nevada, Revision 0

CAU 573 comprises the following corrective action sites (CASs): • 05-23-02, GMX Alpha Contaminated Area • 05-45-01, Atmospheric Test Site - Hamilton These two CASs include the release at the Hamilton weapons-related tower test and a series of 29 atmospheric experiments conducted at GMX. The two CASs are located in two distinctly separate areas within Area 5. To facilitate site investigation and data quality objective (DQO) decisions, all identified releases (i.e., CAS components) were organized into study groups. The reporting of investigation results and the evaluation of DQO decisions are at the release level. The corrective action alternatives (CAAs) were evaluated at the FFACO CAS level. The purpose of this CADD/CAP is to evaluate potential CAAs, provide the rationale for the selection of recommended CAAs, and provide the plan for implementation of the recommended CAA for CAU 573. Corrective action investigation (CAI) activities were performed from January 2015 through November 2015, as set forth in the CAU 573 Corrective Action Investigation Plan (CAIP). Analytes detected during the CAI were evaluated against appropriate final action levels (FALs) to identify the contaminants of concern. Assessment of the data generated from investigation activities conducted at CAU 573 revealed the following: • Radiological contamination within CAU 573 does not exceed the FALs (based on the Occasional Use Area exposure scenario). • Chemical contamination within CAU 573 does not exceed the FALs. • Potential source material—including lead plates, lead bricks, and lead-shielded cables—was removed during the investigation and requires no additional corrective action.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CFD modeling of non-catalytic, partial-oxidation engine reformer for flare mitigation

Flaring associated natural gas is commonly employed in the oil and gas industry to reduce methane (CH 4 ) emissions but generates carbon dioxide (CO 2 ) and harmful pollutants, significantly contributing to air pollution and posing risks to public health. To mitigate this impact, M2X Energy Inc. has developed a small-scale, modular gas-to-methanol system. This system features an engine reformer that performs fuel-rich partial oxidation of wellhead gas to produce syngas—a mixture of carbon monoxide (CO) and hydrogen (H 2 )—followed by a downstream reactor for methanol synthesis. This study focused on computational fluid dynamics (CFD) modeling of the engine reformer to simulate partial oxidation chemistry, predict the rich-burn operating limit, and assess syngas quality, ultimately aiding in design and operational optimization. The CFD model, developed within a Reynolds-Averaged Navier-Stokes (RANS) turbulence framework, incorporated sub-models for turbulent combustion, a chemical mechanism with polycyclic aromatic hydrocarbon (PAH) pathways, and soot emissions to accurately capture the fuel-rich, turbulent jet ignition and combustion processes. Model validation against experimental data showed good agreement across pre- and main-chamber pressures, apparent heat release rates, and exhaust gas concentrations of key species (H 2 , CO, CO 2 , CH 4 ) for varying intake equivalence ratios. Here, the model identified a rich-burn operating limit near a fuel-air equivalence ratio of 2.35, consistent with experimental observations. Furthermore, syngas quality analysis revealed that extending the rich-burn limit through engine reformer optimization could enhance syngas production, contributing to higher methanol synthesis efficiency.

Computational Fluid Dynamics↗

Analysis of alternative climate datasets and evapotranspiration methods for the Upper Mississippi River Basin using SWAT within HAWQS

This study reports the application of Soil andWater Assessment Tool (SWAT) within the Hydrologic andWater Quality System(HAWQS) on-line platform, for the UpperMississippi River Basin (UMRB). TheUMRB is an important ecosystem located in the north central U.S. that is experiencing a range of ecological stresses. Specifically, testing of SWAT was performed for: (1) Hargreaves (HG) and Penman-Monteith (PM) PET methods, and (2) Livneh, National Climatic Data Center (NCDC) and Parameter-elevation Regressions on Independent Slopes Model (PRISM) climate datasets. The Livneh-PM combination resulted in the highest average annual water yield of 380.6 mm versus the lowest estimated water yield of 193.9 mm for the Livneh-HG combination, in response to 23-year uncalibrated simulations. Higher annual ET and PET values were predicted with HG method versus the PM method for all three weather datasets in response to the uncalibrated simulations, due primarily to higher HG-based estimates during the growing season. Based on these results, it was found that the HG method is the preferred PET option for the UMRB. Initial calibration of SWAT was performed using the Livneh data and HGmethod for threeMississippi Rivermain stem gauge sites, which was followed by spatial validation at 10 other gauge sites located within the UMRB streamnetwork. Overall satisfactory results were found for the calibration and validation gauge sites, with the majority of R2 values ranging between 0.61 and 0.82, Nash- Sutcliffe modeling efficiency (NSE) values ranging between 0.50 and 0.79, and Kling-Gupta efficiency (KGE) values ranging between 0.61 and 0.84. The results of an additional experimental suite of six scenarios,which represented different combinations of climate data sets and calibrated parameters, revealed that suggested statistical criteria were again satisfied by the different scenario combinations. Overall, the PRISM data exhibited the strongest reliability for the UMRB.

54 ENVIRONMENTAL SCIENCES↗

Can a shock-induced phonon up-pumping model relate to impact sensitivity of molecular crystals, polymorphs and cocrystals?

Impact sensitivity engineering of high-energy molecular crystals requires accurate predictive models. For this purpose, the promising multi-phonon based approach is selected, assessing a bit more its strengths and weaknesses. Presently used with high-quality phonon calculations of 22 molecular crystals, using a physics-based criterion to determine the phonon bath extent, the resulting intrinsic shock sensitivity index (SSI) is compared to the most common marker of impact sensitivity, h 50 , as determined from drop-weight impact tests. Selecting a data subset from experiments performed under very similar conditions (2.5 kg hammer with grit and 30–40 mg samples), the model can predict h 50 values for mono-molecular crystals with very good accuracy, including the ability to discriminate the polymorphs of HMX and CL20. This very good agreement validates an initial indirect up-pumping mechanism occurring under these conditions, where the doorway modes also interact with the phonon bath. However, the phonon bath criterion for mono-molecular crystals does not transfer well to cocrystals. Owing to the vibrational coupling of the co-molecules, it seems a broader phonon bath should be considered. Additionally recalling experimental uncertainty and various experimental factors affecting h 50 values for a given compounds, we recommend that the density of the sample, granularity and morphology be systematically considered and reported along with measurements, which will in turn allow for more systematic data and predictive capabilities for sensitivity models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The American Board of Radiology perspective on maintenance of certification: Part IV: Practice quality improvement in radiologic physics

Recent initiatives of the American Board of Medical Specialties (ABMS) in the area of maintenance of certification (MOC) have been reflective of the response of the medical community to address public concerns regarding quality of care, medical error reduction, and patient safety. In March 2000, the 24 member boards of the ABMS representing all medical subspecialties in the USA agreed to initiate specialty-specific maintenance of certification (MOC) programs. The American Board of Radiology (ABR) MOC program for diagnostic radiology, radiation oncology, and radiologic physics has been developed, approved by the ABMS, and initiated with full implementation for all three disciplines beginning in 2007. The overriding objective of MOC is to improve the quality of health care through diplomate-initiated learning and quality improvement. The four component parts to the MOC process are: Part I: Professional standing, Part II: Evidence of life long learning and periodic self-assessment, Part III: Cognitive expertise, and Part IV: Evaluation of performance in practice (with the latter being the focus of this paper). The key components of Part IV require a physicist-based response to demonstrate commitment to practice quality improvement (PQI) and progress in continuing individual competence in practice. Diplomates of radiologic physics must select a project to be completed over the ten-year cycle that potentially can improve the quality of the diplomate's individual or systems practice and enhance the quality of care. Five categories have been created from which an individual radiologic physics diplomate can select one required PQI project: (1) Safety for patients, employees, and the public, (2) accuracy of analyses and calculations, (3) report turnaround time and communication issues, (4) practice guidelines and technical standards, and (5) surveys (including peer review of self-assessment reports). Each diplomate may select a project appropriate for an individual, participate in a project within a clinical department, participate in a peer review of a self-assessment report, or choose a qualified national project sponsored by a society. Once a project has been selected, the steps are: (1) Collect baseline data relevant to the chosen project, (2) review and analyze the data, (3) create and implement an improvement plan, (4) remeasure and track, and (5) report participation to the ABR, using the template provided by the ABR. These steps begin in Year 2, following training in Year 1. Specific examples of individual PQI projects for each of the three disciplines of radiologic physics are provided. Now, through the MOC programs, the relationship between the radiologic physicist and the ABR will be continuous through the diplomate's professional career. The ABR is committed to providing an effective infrastructure that will promote and assist the process of continuing professional development including the enhancement of practice quality improvement for radiologic physicists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data preparation and evaluation techniques for x-ray diffraction microscopy

The post-experiment processing of X-ray Diffraction Microscopy data is often time-consuming and difficult. This is mostly due to the fact that even if a preliminary result has been reconstructed, there is no definitive answer as to whether or not a better result with more consistently retrieved phases can still be obtained. In addition, we show here that the first step in data analysis, the assembly of two-dimensional diffraction patterns from a large set of raw diffraction data, is crucial to obtaining reconstructions of highest possible consistency. We have developed software that automates this process and results in consistently accurate diffraction patterns. We have furthermore derived some criteria of validity for a tool commonly used to assess the consistency of reconstructions, the phase retrieval transfer function, and suggest a modified version that has improved utility for judging reconstruction quality.

36 MATERIALS SCIENCE↗

Pacific Northwest National Laboratory Site Environmental Report for Calendar Year 2011

The PNNL Site Environmental Report for Calendar Year 2011 was prepared pursuant to the requirements of Department of Energy (DOE) Order 231.1B, "Environment, Safety and Health Reporting" to provide a synopsis of calendar year 2011 information related to environmental management performance and compliance efforts. It summarizes site compliance with federal, state, and local environmental laws, regulations, policies, directives, permits, and orders and environmental managemePacific Northwest National Laboratory (PNNL), one of 10 national laboratories supporting the U.S. Department of Energy (DOE) Office of Science, provides innovative science and technology development in the areas of energy and the environment, fundamental and computational science, and national security. DOE’s Pacific Northwest Site Office (PNSO) is responsible for PNNL oversight in Richland, Washington, as well as facilities in Sequim, Seattle, and North Bonneville, Washington, and Portland, Oregon. This site environmental report provides a synopsis of ongoing environmental management performance and compliance activities conducted during 2011. The report addresses the operations occurring on PNNL’s Richland campus, which includes PNSO’s PNNL Site facilities and Battelle-owned and -leased facilities. The report includes a description of the PNSO Site and setting; addresses compliance with all applicable DOE, federal, state, and local regulations; documents environmental monitoring efforts and status; presents potential radiation doses to staff and the public in the surrounding area; and data quality assurance methodsnt performance.

air quality↗

2018 Annual Site Environmental Report Sandia National Laboratories, New Mexico

Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the United States Department of Energy (DOE) National Nuclear Security Administration. The National Nuclear Security Administration's Sandia Field Office administers the contract and oversees contractor operations at Sandia National Laboratories, New Mexico. Activities at the site support research and development programs with a wide variety of national security missions, resulting in technologies for nonproliferation, homeland security, energy and infrastructure, and defense systems and assessments. DOE and its management and operating contractor for Sandia are committed to safeguarding the environment reassessing sustainability practices and ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This report summarizes the environmental protection and monitoring programs in place at Sandia National Laboratories, New Mexico, during calendar year 2018. Environmental topics include air quality, ecology, environmental restoration, oil storage, site sustainability, terrestrial surveillance, waste management, water quality, and implementation of the National Environmental Policy Act. This report is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety, and Health Reporting and has been approved for public distribution.

54 ENVIRONMENTAL SCIENCES↗

Aerospace Systems Design in NASA's Collaborative Engineering Environment

Past designs of complex aerospace systems involved an environment consisting of collocated design teams with project managers, technical discipline experts, and other experts (e.g. manufacturing and systems operations). These experts were generally qualified only on the basis of past design experience and typically had access to a limited set of integrated analysis tools. These environments provided less than desirable design fidelity, often lead to the inability of assessing critical programmatic and technical issues (e.g., cost risk, technical impacts), and generally derived a design that was not necessarily optimized across the entire system. The continually changing, modern aerospace industry demands systems design processes that involve the best talent available (no matter where it resides) and access to the best design and analysis tools. A solution to these demands involves a design environment referred to as collaborative engineering. The collaborative engineering environment evolving within the National Aeronautics and Space Administration (NASA) is a capability that enables the Agency's engineering infrastructure to interact and use the best state-of-the-art tools and data across organizational boundaries. Using collaborative engineering, the collocated team is replaced with an interactive team structure where the team members are geographically distributed and the best engineering talent can be applied to the design effort regardless of physical location. In addition, a more efficient, higher quality design product is delivered by bringing together the best engineering talent with more up-to-date design and analysis tools. These tools are focused on interactive, multidisciplinary design and analysis with emphasis on the complete life cycle of the system, and they include nontraditional, integrated tools for life cycle cost estimation and risk assessment. NASA has made substantial progress during the last two years in developing a collaborative engineering environment. NASA is planning to use this collaborative engineering infrastructure to provide better aerospace systems life cycle design and analysis, which includes analytical assessment of the technical and programmatic aspects of a system from "cradle to grave." This paper describes the recent NASA developments in the area of collaborative engineering, the benefits (realized and anticipated) of using the developed capability, and the long-term plans for implementing this capability across the Agency.

Monell, Donald W.↗

CERES Fast Longwave And SHortwave Radiative Flux (FLASHFlux): Research to Operation

The Clouds and Earth’s Radiant Energy System (CERES) project provides satellite-based observations of how Earth’s energy flows are varying in time and space and how clouds and aerosols are affecting the Earth’s radiation budget. Nominally, CERES data products require months of validation and calibration before releasing a climate quality data. The Fast Longwave and Shortwave Radiative Flux (FLASHFlux) data product was developed as to provide key data for applied science research involving the renewable energy and agricultural sectors within a week of observations. FLASHFlux achieves this by using simplified calibration, an operation meteorology product from Global Modeling and Assimilation Office (GMAO), and its own surface parameterizations model. The CERES FLASHFlux provides two data products: 1) an hourly Level 2 Single Scanner Footprint (SSF) data separately for Aqua and Terra observations, and 2) a daily Level 3 Time Interpolated and Spatially Averaged (TISA) 1ox 1ogridded data that combines Aqua and Terra observations. We inter-compared of FLASHFlux Version4A calibration to the climate quality CERES Edition4A data product over time. In addition, we also inter-compared the impact of the fluxes by using the near real-time GMAO GEOS FP-IT instead of GMAO G5-CERES meteorology data. We also compare both SSF overpass and TISA radiative flux products to a set of surface measurement sites that are globally distributed and assess agreement.

P. C. Sawaengphokhai↗

Retrieval of Aerosol Optical Properties From GOCI-II Observations: Continuation of Long-Term Geostationary Aerosol Monitoring Over East Asia

Since the Geostationary Ocean Color Imager (GOCI) was successfully launched in 2010, the GOCI Yonsei aerosol retrieval (YAER) algorithm has been continuously updated to retrieve hourly aerosol optical properties. GOCI-II has 4 more channels including UV, finer spatial resolution (250 m), and daily full disk coverage as compared to GOCI, and was launched in February 2020, onboard the GEO-KOMPSAT-2B (GK-2B) satellite. In this study, we extended the YAER algorithm to GOCI-II data based on its improved performance in many aspects and present the first results of aerosol optical properties retrieved from GOCI-II data. Utilizing the overlapping period between the GOCI-II and GOCI in geostationary Earth orbit, we present GOCI-II aerosol retrievals for high aerosol-loading cases over East Asia and show that these have a consistent spatial distribution with those from GOCI. Furthermore, GOCI-II provides AOD at an even higher spatial resolution, revealing finer changes in aerosol concentrations. Validation results for one year data show that the GOCI-II AOD has a correlation coefficient of 0.83 and a ratio within the expected error (EE) of 59.4 % when compared with the aerosol robotic network (AERONET) data. We compared statistical metrics for the GOCI and GOCI-II AODs to assess the consistency between the two datasets. In addition, it was found that there is a strong correlation between the two datasets from the comparison of gridded GOCI and GOCI-II AOD products. It is expected that data from GOCI-II will continue long-term aerosol records with high accuracy that can be used to address air-quality issues over East Asia.

AOD↗

2015 China Green Low-Carbon City scorecard

In China’s rapid urbanization and industrialization, cities are playing important roles in helping the country reach its climate change mitigation goal of peaking CO2 emissions around 2030, and improving environmental quality. During the 12th Five-Year Plan (12th FYP) period (2011–2015), Chinese cities set ambitious goals and implemented diverse policies aimed at transitioning to a greener economy. The Chinese central government also set targets on a number of indicators, such economic energy intensity and carbon intensity (e.g., CO2 per unit GDP), and air quality (e.g., PM2.5 concentration). These targets are helpful for tracking implementation of individual policies or progress at a sectoral level. However, a more comprehensive and integrated approach is needed to assess progress and capture the multi-dimensional aspects of Chinese cities’ transition to a greener economy, an approach that offers comparison with international best practices, as well as working with data availability in China’s statistical system. This paper presents the development of a China Green LowCarbon City Index2 (CGLCCI, or City Index) and its application to 115 Chinese cities – the largest assessment of Chinese cities to date. The GCLCCI includes 23 key indicators across seven categories: economy, energy, industry, buildings, transportation, environment and land use, and climate policy and outreach. This paper applied the CGLCCI to benchmark the green and low-carbon development status of 115 Chinese cities in the year 2015. Data for the analysis came from government and publicly available data sources. The CGLCCI methodology provides a standardized method to benchmark each indicator, calculate overall city scores, and rank the cities.3 The results showed that the low-carbon transition in Chinese cities is still in its early stages. Compared to the best practices benchmarks, the 2015 City Index scores ranged from a low of 28 to a high score of 70 in 2015 (maximum score is 100). This paper also presents three top-performing cities in different stages of development and discusses how their scores across the index categories. Creating a green low-carbon index that relies on publicly available data in China, and regularly evaluating city performance, can encourage Chinese cities to learn best practices from each other, and to strengthen their goals and implementation efforts toward a green low-carbon transition.

Zhang, Jingjing↗

High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs

Effective and efficient health management of sensing channels and instrumentation supports reliable and accurate process monitoring capacities in any industry. Current practice in the nuclear industry relies on periodic calibration assessment and correction activities. This time based maintenance technique consists of three steps: i) removal of sensor to a test environment, ii) testing and recalibration, and iii) reinstallation of sensor into its working environment. This procedure is highly labor intensive, adds to the outage cost and timeline, and contributes to worker radiation exposure and ALARA requirements. Furthermore, the human element contributes to error factors in all stages of the procedure. The effectiveness of this calibration procedure after sensors are returned to working environmental variables also raises concerns, and the practicability of this periodic approach is uncertain for future reactor designs with longer operating cycles between refueling outages. Studies indicate that periodic calibration assessment find only 10% of sensing instrumentations with calibration issues during a single outage (18- 24 months), meaning at least 90% of sensors are undergoing unnecessary maintenance actions. This provides an opportunity to maintain the current levels of safety and functional integrity with fewer, more targeted maintenance actions and lower economic burden. Performance-based maintenance planning shows much promise over current periodic maintenance approaches. Specifically, online monitoring (OLM) utilizes the continually collected process data to non-intrusively monitor the calibration status of process instrumentation and detect the onset of de-calibration, thereby minimizing the number of recalibration procedures required. Ultimately, this can lead to termination of time based recalibration at NPPs. OLM utilizes the process measurements made for process monitoring and control to evaluate the calibration status of the sensors and instrumentation making the measurements. OLM can detect and differentiate sensor faults and process anomalies, thus providing a valuable tool to suit the industry's and regulatory body's requirements. Though supported by more than a decade of research, OLM for sensor calibration assessment is yet to be implemented in the US fleet due to regulatory requirements and constraints. As shown in Figure 1, OLM utilizes process data to train statistical models that predict normal, error-free process behavior. Measured process values are compared with error-corrected predictions to ascertain the presence of faults. The reliability of OLM is dependent on the quality of its predictions, measured in part by the uncertainty in these predictions. This research develops a framework to accurately quantify the prediction uncertainty based on Bayesian inference techniques to provide the required confidence levels for OLM systems. The expected outcomes include signal validation by high-accuracy, high-confidence uncertainty quantification for variable sensor types and operating ranges. Furthermore, the framework will facilitate fault detection capacities and so-called virtual sensors, a capability to replace faulty sensor measurements with error-corrected values when a sensor fault is detected. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An assessment of AVIRIS data for hydrothermal alteration mapping in the Goldfield Mining District, Nevada

Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) data were acquired over the Goldfield Mining District, Nevada, in September 1987. Goldfield is one of the group of large epithermal precious metal deposits in Tertiary volcanic rocks, associated with silicic volcanism and caldera formation. Hydrothermal alteration consists of silicification along fractures, advanced agrillic and argillic zones further away from veins and more widespread propylitic zones. An evaluation of AVIRIS data quality was performed. Faults in the data, related to engineering problems and a different behavior of the instrument while on-board the U2, were encountered. Consequently, a decision was made to use raw data and correct them only for dark current variations and detector read-out-delays. New software was written to that effect. Atmospheric correction was performed using the flat field correction technique. Analysis of the data was then performed to extract spectral information, mainly concentrating on the 2 to 2.45 micron window, as the alteration minerals of interest have their distinctive spectral reflectance features in this region. Principally kaolinite and alunite spectra were clearly obtained. Mapping of the different minerals and alteration zones was attempted using ratios and clustering techniques. Poor signal-to-noise performance of the instrument and the lack of appropriate software prevented the production of an alteration map of the area. Spectra extracted locally from the AVIRIS data were checked in the field by collecting representative samples of the outcrops.

Carrere, Veronique↗

Public Health Data Applications Using the CDC Tracking Network: Augmenting Environmental Hazard Information with Lower-latency NASA Data

Exposure to environmental hazards is an important determinant of health, and the frequency and severity of exposures is expected to be impacted by climate change. Through a partnership with the U.S. National Aeronautics and Space Administration, the U.S. Centers for Disease Control and Prevention’s National Environmental Public Health Tracking Network is integrating timely observations and model data of priority environmental hazards into its publicly accessible Data Explorer (https://ephtracking.cdc.gov/DataExplorer/). Newly integrated datasets over the contiguous U.S. (CONUS) include: daily 5-day forecasts of air quality based on the Goddard Earth Observing System Composition Forecast (GEOS-CF), daily historical (1980-present) concentrations of speciated PM2.5 based on the Modern Era Retrospective analysis for Research and Applications, version 2 (MERRA-2), and Moderate Resolution Imaging Spectroradiometer (MODIS) daily near real-time maps of flooding (MCDWD). Data integrated into the CDC Tracking Network are broadly intended to improve community health through action by informing both research and early warning activities, including (1) describing temporal and spatial trends in disease and potential environmental exposures, (2) identifying populations most affected, (3) generating hypotheses about associations between health and environmental exposures, and (4) developing, guiding, and assessing environmental public health policies and interventions aimed at reducing or eliminating health outcomes associated with environmental factors.

air quality↗

Aerospace Systems Design in NASA's Collaborative Engineering Environment

Past designs of complex aerospace systems involved an environment consisting of collocated design teams with project managers, technical discipline experts, and other experts (e.g., manufacturing and systems operation). These experts were generally qualified only on the basis of past design experience and typically had access to a limited set of integrated analysis tools. These environments provided less than desirable design fidelity, often lead to the inability of assessing critical programmatic and technical issues (e.g., cost, risk, technical impacts), and generally derived a design that was not necessarily optimized across the entire system. The continually changing, modern aerospace industry demands systems design processes that involve the best talent available (no matter where it resides) and access to the the best design and analysis tools. A solution to these demands involves a design environment referred to as collaborative engineering. The collaborative engineering environment evolving within the National Aeronautics and Space Administration (NASA) is a capability that enables the Agency's engineering infrastructure to interact and use the best state-of-the-art tools and data across organizational boundaries. Using collaborative engineering, the collocated team is replaced with an interactive team structure where the team members are geographical distributed and the best engineering talent can be applied to the design effort regardless of physical location. In addition, a more efficient, higher quality design product is delivered by bringing together the best engineering talent with more up-to-date design and analysis tools. These tools are focused on interactive, multidisciplinary design and analysis with emphasis on the complete life cycle of the system, and they include nontraditional, integrated tools for life cycle cost estimation and risk assessment. NASA has made substantial progress during the last two years in developing a collaborative engineering environment. NASA is planning to use this collaborative engineering engineering infrastructure to provide better aerospace systems life cycle design and analysis, which includes analytical assessment of the technical and programmatic aspects of a system from "cradle to grave." This paper describes the recent NASA developments in the area of collaborative engineering, the benefits (realized and anticipated) of using the developed capability, and the long-term plans for implementing this capability across Agency.

Monell, Donald W.↗

SU-G-206-07: Dual-Energy CT Inter- and Intra-Scanner Variability Within One Make and Model

Purpose: It can be logistically quite difficult to scan patients on the same exact device for their repeat visits in multi-scanner facilities. The reliability between dual-energy CT scanners’ quantitative results is not known, nor is their individual repeatability. Therefore, we evaluated inter- and intra-scanner variability with respect to several key clinical quantitative metrics specific to dual-energy CT. Methods: Eleven identical GE HD-750 CT scanners in a busy clinical environment were used to perform dual-energy (DE) CT scans of a large elliptical quality control (QC) phantom (Gammex, Inc.; Middleton, WI) which contains many standard insert materials. The DE-QC phantom was scanned bi-weekly during 2016; 3 to 4 scans were obtained from each scanner (a total of 35 data sets were used for analysis). Iodine accuracy for the 2mg/ml, 5mg/ml and 15mg/ml rods (from the Iodine(Water) image set) and soft tissue HU (40 HU based on NIST constants) from the 50keV data set were used to assess inter- and intra-scanner variability (standard deviation). Results: Intra-scanner variability average for 2mg/ml Iodine was 0.10 mg/ml (range 0.05–0.15 mg/ml), for 5mg/ml Iodine was 0.12 mg/ml (range 0.07–0.16 mg/ml), for 15 mg/ml Iodine was 0.25 mg/ml (range 0.16–0.37 mg/ml), and for the soft tissue inserts was 2.1 HU (range 1.8–2.6 HU). Inter-scanner variability average for 2mg/ml Iodine was 0.16 mg/ml (range 0.11–0.19 mg/ml), for 5mg/ml Iodine was 0.18 mg/ml (range 0.11–0.22 mg/ml), for 15 mg/ml Iodine was 0.35 mg/ml (range 0.23–0.44 mg/ml), and for the soft tissue inserts was 3.8 HU (range 3.1–4.5 HU). Conclusion: Intra-scanner variability for the iodine and soft tissue inserts averaged 3.1% and 5.2% respectively, and inter-scanner variability for these regions analyzed averaged 5.0% and 9.5%, respectively. Future work will include determination of smallest measurable change and acceptable limits for DE-CT scanner variability over longer time intervals. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.

60 APPLIED LIFE SCIENCES↗