Development of Message Passing Routines for High Performance Parallel Computations

Computational Fluid Dynamics (CFD) calculations require a great deal of computing power for completing the detailed computations involved. In an effort shorten the time it takes to complete such calculations they are implemented on a parallel computer. In the case of a parallel computer some sort of message passing structure must be used to communicate between the computers because, unlike a single machine, each computer in a parallel computing cluster does not have access to all the data or run all the parts of the total program. Thus, message passing is used to divide up the data and send instructions to each machine. The nature of my work this summer involves programming the "message passing" aspect of the parallel computer. I am working on modifying an existing program, which was written with OpenMP, and does not use a multi-machine parallel computing structure, to work with Message Passing Interface (MPI) routines. The actual code is being written in the FORTRAN 90 programming language. My goal is to write a parameterized message passing structure that could be used for a variety of individual applications and implement it on Silicon Graphics Incorporated s (SGI) IRIX operating system. With this new parameterized structure engineers would be able to speed up computations for a wide variety of purposes without having to use larger and more expensive computing equipment from another division or another NASA center.

Summers, Edward K.↗

CEED-MS8:Initial Integration of CEED Software in ECP Applications

Key components of CEED software development involve fast finite element operator storage and evaluation, architecture optimizations, performant algorithms for all orders, global kernels for finite element operators, efficient use of the memory sub-system, optimal data locality and motion, enhanced scalability and parallelism, and fast tensor contractions. As ultimate goals of the project, CEED is exploring and identifying the best algorithms for the full range of discretizations and applying algorithmic and software development to support ECP applications’ needs. In this milestone we report on the initial integration of CEED software in the selected first-wave ECP/CEED apps and the continued exploration of other ECP applications as second-wave (milestone CEED-MS23) and third-wave (milestone CEED-MS35) ECP/CEED application candidates. An extensive evaluation of various approaches for GPU acceleration of the CEED computational motives is also a major focus of the report, both in the settings of CEED’s Nekbone and Laghos miniapps, as well as versions of CEED’s bake-off problems (introduced in milestone CEED-MS6). The first-wave ECP applications targeted for coupling with CEED software include the ExaSMR and MARBL applications. We also report on near-term collaboration with the seed-funded Urban Systems project, as well as engagements with ACME, ExaAM, GEOS and the Application Assessment and Proxy App projects. The ExaSMR project involves coupled thermal-hydraulics/neutronics, with the latter based on Monte Carlo methods and the former based on high-order discretizations of the Navier-Stokes and energy equations for accurate simulation of turbulent transport. The project requires fast and efficient turbulence simulation capabilities that will scale to exascale platforms. Work within CEED will ensure that all aspects of the Nek5000 workflow scale to the target problem space, which involves > 10 10 degrees of freedom in typical production runs. CEED’s goal is to provide implementations that perform with maximum attainable efficiency and deliver low turn-around times. A deliverable for this milestone is beta-release of the GPU-based variant of Nek5000. MARBL is targeting high-energy-density physics problems, including single fluid multi-material hydrodynamics and radiation/magnetic diffusion simulation, with applications in inertial confined fusion, pulsed power experiments, and equation of state/material strength analysis. The code uses high-order methods based arbitrary Lagrangian-Eulerian, direct Eulerian, and unstructured adaptive mesh refinement. A deliverable for this milestone is collaboration with MARBL for improved performance based on partially-assembled operators. The Urban exascale project is planning to couple real-time data with high performance simulations to study particulate transport in cities. Nek5000 will be used for large eddy and RANS (Reynolds-averaged Navier-Stokes) simulations of turbulent transport in these domains. Areas where the CEED team is aiding the Urban Canyon group include creating high-order meshes for urban geometries and developing boundary conditions appropriate for simulations close to real-life urban conditions. The software artifacts delivered as part of this milestone include GPU-enabled versions of the Nekbone and Laghos miniapps, which are provided through the CEED website, http://ceed.exascaleproject.org and the CEED GitHub organization, http://github.com/ceed. In addition to details and results from the above R&D efforts, in this document we are also reporting on other project-wide activities performed in Q4 of FY17, including: the CEED first annual meeting and participation of CEED researchers in a variety of outreach activities.

97 MATHEMATICS AND COMPUTING↗

Quantification of Data Needs, Data Collection and

Further to the development of a model analysis framework suitable for calibration and validation of complex multivariate multiphysics models, this report presents an approach to data collection and characterization which can work in parallel with the above-mentioned model analysis framework and support the calibration and validation of the case-study subcooled flow boiling model.

97 MATHEMATICS AND COMPUTING↗

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide relatively accurate motion fields and yield tMR-based motion corrected PET images with similar image quality as those reconstructed using fully sampled tMR data. The reduction of tMR acquisition time makes it more compatible with routine clinical cardiac PET-MR studies.

60 APPLIED LIFE SCIENCES↗

Parker Hybrid Hydraulic Drivetrain Demonstration

This report examines the benefits of Parker Hannifin hydraulic hybrid brake energy recovery systems used in commercial applications for vocational purposes. A detailed background on the problem statement being addressed as well as the solution set specific for parcel delivery will be provided. Objectives of the demonstration performed in high start & stop applications included opportunities in fuel usage reduction, emissions reduction, vehicle productivity, and vehicle maintenance. Completed findings during the demonstration period and parallel investigations with NREL, CALSTART, along with a literature review will be provided herein on this research area. Lastly, results identified in the study by third parties validated the savings potential in fuel reduction of on average of 19% to 52% over the baseline in terms of mpg (Lammert, 2014, p11), Parker data for parcel delivery vehicles in the field parallels this at a range of 35% - 50%, emissions reduction of 17.4% lower CO 2 per mile and 30.4% lower NO x per mile (Gallo, 2014, p15), with maintenance improvement in the areas of brake and starter replacement, while leaving room for further study in the area of productivity in terms of specific metrics that can be applied and studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Visual Analytics Approach for Correlation, Classification, and Regression Analysis

New approaches that combine the strengths of humans and machines are necessary to equip analysts with the proper tools for exploring today's increasing complex, multivariate data sets. In this paper, a novel visual data mining framework, called the Multidimensional Data eXplorer (MDX), is described that addresses the challenges of today's data by combining automated statistical analytics with a highly interactive parallel coordinates based canvas. In addition to several intuitive interaction capabilities, this framework offers a rich set of graphical statistical indicators, interactive regression analysis, visual correlation mining, automated axis arrangements and filtering, and data classification techniques. The current work provides a detailed description of the system as well as a discussion of key design aspects and critical feedback from domain experts.

97 MATHEMATICS AND COMPUTING↗

A scalable framework for efficient coupling of thermal and microstructural simulations in additive manufacturing

Predicting microstructure evolution in metal additive manufacturing (AM) is important for process optimization, but spatiotemporal scale disparities between thermal transport and microstructure evolution create significant challenges for efficient data transfer between simulation codes. To address this, we present Stork, a scalable framework for coupling thermal and microstructural simulations. Stork uses a sparse data representation to identify and store active solidification sub-volumes, enabling highly parallel quad-linear interpolation from coarse thermal grids to fine microstructure grids without large intermediate storage. We demonstrate the framework by coupling the semi-analytic heat transfer code 3DThesis with the time-parallel cellular automata code Toucan. This approach achieves over two orders of magnitude reduction in data generation time and file size compared to prior workflows. Numerical studies show that quad-linear interpolation preserves grain morphology and crystallographic texture in laser powder bed fusion (LPBF) simulations for coarsening ratios up to 16. Overall, Stork provides a scalable pathway for high-throughput, component-scale AM simulations on modern high-performance computing systems.

36 MATERIALS SCIENCE↗

Obtaining and Managing Answer Quality for Online Data-Intensive Services

Online data-intensive (OLDI) services use anytime algorithms to compute over large amounts of data and respond quickly. Interactive response times are a priority, so OLDI services parallelize query execution across distributed software components and return best effort answers based on the data so far processed. Omitted data from slow components could lead to better answers, but tracing online how much better the answers could be is difficult. Here, we introduce Ubora, a design method to measure the effect of slow-running components on the quality of answers. Ubora randomly samples online queries and executes them a second time. The first online execution omits data from slow components and provides interactive answers. The second execution uses mature results from intermediate components completed after the online execution finishes. Ubora uses memoization to speed up mature executions by replaying network messages exchanged between components. Our systems-level implementation works for a wide range of services, including Hadoop/Yarn, Apache Lucene, the EasyRec Recommendation Engine, and the OpenEphyra question-answering system. Ubora computes answer quality with more mature executions per second than competing approaches that do not use memoization. With Ubora, we illustrate that answer quality is effective at guiding online admission control. While achieving the same answer quality on high-priority queries, our adaptive controller had 55% higher peak throughput on low-priority queries than a competing controller guided by the rate of timeouts.

answer quality↗

Scientific Data Services -- A High-Performance I/O System with Array Semantics

As high-performance computing approaches exascale, the existing I/O system design is having trouble keeping pace in both performance and scalability. We propose to address this challenge by adopting database principles and techniques in parallel I/O systems. First, we propose to adopt an array data model because many scientific applications represent their data in arrays. This strategy follows a cardinal principle from database research, which separates the logical view from the physical layout of data. This high-level data model gives the underlying implementation more freedom to optimize the physical layout and to choose the most effective way of accessing the data. For example, knowing that a set of write operations is working on a single multi-dimensional array makes it possible to keep the subarrays in a log structure during the write operations and reassemble them later into another physical layout as resources permit. While maintaining the high-level view, the storage system could compress the user data to reduce the physical storage requirement, collocate data records that are frequently used together, or replicate data to increase availability and fault-tolerance. Additionally, the system could generate secondary data structures such as database indexes and summary statistics. We expect the proposed Scientific Data Services approach to create a “live” storage system that dynamically adjusts to user demands and evolves with the massively parallel storage hardware.

97 MATHEMATICS AND COMPUTING↗

Power Analysis for Applications and Data Centers

A portion of a chapter for the High Performance Parallelism Pearls 2 book. By using the NWPerf and CView software developed and deployed at PNNL administrators and users can visually see the performance, and power used by jobs running on a super computer in near-time.

Affinity↗

An Approach to Enhance pnetCDF Performance in Environmental Modeling Applications

I/O has been considered as a bottleneck in parallel applications. The software package, pnetCDF which works with parallel file systems, was developed to address this issue and provide parallel I/O capability. This study examines the performance of a novel approach which performs data aggregation along either row or column dimension of the spatial domain, and then applies the pnetCDF parallel I/O paradigm. The test was done with three different domain sizes which represents small, moderately large and large data domains, using a small scale Community Multi-scale Air Quality model (CMAQ) mocked up code. The examination includes comparing I/O performance with traditional serial I/O technique, straight application of pnetCDF, and the data aggregation along row and column dimension before applying pnetCDF. After the comparison, “optimal” I/O configurations for this new novel approach were quantified. Data aggregation along the row dimension (pnetCDFcr) works better than along the column dimension (pnetCDFcc) although it may perform slightly worse than straight the pnetCDF method with a small number of processors. When the number of processors becomes larger, pnetCDFcr out performs pnetCDF significantly. If the number of processors keeps increasing, pnetCDF reaches a point that the performance is even worse than the serial I/O technique. This new approach has also been tested on a real application where it performs two times better than the straight pnetCDF paradigm.

I/O↗

Methanol Partial Oxidation on MoO 3 /SiO 2 Catalysts: Application of Vibrational Spectroscopic Imaging Techniques in a High Throughput Operando Reactor

A novel prototype high throughput operando (OHT) reactor designed and built for catalyst screening and characterization is presented in this article. For the first time, this OHT reactor integrates Fourier Transformation infrared (FT-IR) imaging technique and Raman spectroscopy in operando conditions. Using a focal plane array (HgCdTe FPA, 128x128 pixels, and 1,675 Hz frame rate) detector for the FT-IR imaging system, we are able to simultaneously follow the catalyst activity and selectivity of all parallel reaction channels. Each set of image data has 16, 384 IR spectra with a spectral range of 900-4000 cm-1 in an 8 cm-1 resolution. It only takes 2-20 second, depending on signal to noise ratio, to collect a full image of all reaction channels. Results on reactant conversion and product selectivity are obtained from FT-IR spectral analysis. Six home-designed Raman probes, one for each reaction channel, are used for simultaneous collection of Raman spectra of all catalysts and possible reaction intermediates on the catalyst surface under real reaction environment. As a model system, methanol partial oxidation reaction on silica supported molybdenum oxide (MoO 3 /SiO 2 ) catalysts under different reaction conditions has been studied to show the performance of the OHT reactor.

10 SYNTHETIC FUELS↗

In situ multi-tier auto-ignition detection applied to dual-fuel combustion simulations

Here we use an anomaly detection methodology that is centered on analyzing fourth-order joint moments (co-kurtosis), particularly focusing on its application in auto-ignition of combustion problems with large numbers of species. Unsupervised anomaly detection is challenging to generalize across problem types and domains. A recent technique, centered on analyzing information in the fourth-order joint moment co-kurtosis, has shown promise, especially for high-dimensional scientific data. In this work we present developments to the co-kurtosis based anomaly detection method needed to make it effective and scalable for large-scale distributed scientific data, such as those generated by massively parallel simulations. An in situ co-kurtosis algorithm is employed as the anomaly detection method for identifying ignition kernels in simulations of turbulent combustion. Here, we extend an existing methodology which identifies regions of the domain where anomalies are present, and add another tier of anomaly detection where the individual samples contributing to the anomaly are identified. We apply this algorithm on-the-fly to a variety of turbulent reacting flow problems and compare it to the widely used (but significantly more expensive) chemical explosive mode analysis (CEMA). We demonstrate the ability of the method to detect and identify the onset of low and high temperature ignition which can be used for computational steering, as chemical and combustion anomalies occur intermittently at spatio-temporal locations unknown a priori. Finally, we apply our lightweight in situ algorithm to an exascale high-fidelity simulation with a total of 2.4 Trillion degrees of freedom, performed using an adaptive mesh refinement solver. Furthermore, through a scalability analysis, we show that the relative computational cost of this in-situ anomaly detection algorithm compared to an iteration of the reacting flow solver is negligible.

97 MATHEMATICS AND COMPUTING↗

Estimating gas concentration using a microcantilever-based electronic

This paper investigates the determination of the concentration of a chemical vapor as a function of several nonspecific microcantilever array sensors. The nerve agent dimethyl methyl phosphonate (DMMP) in parts-per-billion concentrations in binary and ternary mixtures is able to be resolved when present in a mixture containing parts-per-million concentrations of water and ethanol. The goal is to not only detect the presence of DMMP, but additionally to map the nonspecific output of the sensor array onto a concentration scale. We investigate both linear and nonlinear approaches the linear approach uses a separate least-squares model for each component, and a nonlinear approach which estimates the component concentrations in parallel. Application of both models to experimental data indicate that both models are able to produce bounded estimates of concentration, but that the outlier performance favors the linear model. The linear model is better suited to portable handheld analyzer, where processing and memory resources are constrained.

electronic nose↗

Dosimetry of Small Circular Fields for 6-MeV Electron Beams

Small field electron beams used in the clinic present complex dosimetry. This investigation reports dosimetric characteristics of small 6-MeV electron field measurements and Monte Carlo calculations, and examines their impact on patient dosimetry. Radiographic film and ionization chamber were used for dosimetric measurements for a 6-MeV electron beam from a Varian 21EX linac. A set of circular cerrobend cutouts with diameters ranging from 2 to 3.0 cm was made. A clinical Monte Carlo algorithm was used to calculate dosimetric parameters. As the cutout diameter decreased, the build-up portion of the percentage depth dose (PDD) curves shifted toward the phantom surface, the depth of maximum dose, d{sub max,} decreased from 1.2 cm to 0.6 cm, but the practical range, R{sub p}, remained constant at about 3.1 cm. The absorbed dose rate, D{sub r}, decreased linearly with decreasing diameter. Profile coverage ratios CR (ie, the ratio of a given isodose line to the cutout diameter) at d{sub max}, for 90% and 80%, CR{sub 90}, CR{sub 80}, are approximately 55% and 73%, respectively. As the cutout diameter decreased, the 90% to 10% penumbra to diameter ratio, PR, increased from 0.49 to 0.56 for 3- to 2-cm cutouts. The total 90% to 10% penumbra was about the same size as the cutout diameter. The measured output factors were in good agreement with Monte Carlo calculation within 2.2%. Accurate small electron field measurements were performed using parallel plate ion chamber and film. The data were well supported by Monte Carlo calculations. These data facilitate routine clinical treatments for small cutouts as d{sub max}, D{sub r}, and other data can be quickly obtained instead of performing labor-intensive individual patient measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Molecular-Flow Properties of RIB Type Vapor-Transport Systems Using a Fast-Valve

The advent of the fast-valve device, described previously, permits measurement of molecular-flow times of chemically active or inactive gaseous species through radioactive ion beam (RIB) target ion source systems, independent of size, geometry and materials of construction. Thus, decay losses of short-half-life RIBs can be determined for a given target/vapor-transport system in advance of on-line operation, thereby ascertaining the feasibility of the system design for successful processing of a given isotope. In this article, molecular-flow-time theory and experimentally measured molecular-flow time data are given for serial- and parallel-coupled Ta metal RIB vapor-transport systems similar to those used at ISOL based RIB facilities. In addition, the effect of source type on the molecular-flow time properties of a given system is addressed, and a chemical passivation method for negating surface adsorption enthalpies for chemically active gaseous species on Ta surfaces is demonstrated.

Alton, Gerald D↗

Sensitive Targeted Quantification of ERK Phosphorylation Dynamics and Stoichiometry in Human Cells without Affinity Enrichment

Mass spectrometry-based targeted quantification is a promising technology for site-specific quantification of posttranslational modifications (PTMs). However, a major constraint of most targeted MS approaches is the limited sensitivity for quantifying low-abundance PTMs, requiring the use of affinity reagents to enrich specific PTMs. Herein, we demonstrate the direct site-specific quantification of ERK phosphorylation isoforms (pT, pY, pTpY) and their relative stoichiometries using a highly sensitive targeted MS approach termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM). PRISM provides effective enrichment of target peptides within a given fraction from complex biological matrix with minimal sample losses, followed by selected reaction monitoring (SRM) quantification. The PRISM-SRM approach enabled direct quantification of ERK phosphorylation in human mammary epithelial cells (HMEC) from as little as 25 µg tryptic peptides from whole cell lysates. Compared to immobilized metal-ion affinity chromatography, PRISM provided >10-fold improvement in signal intensities, presumably due to the better peptide recovery of PRISM for handling small size samples. This approach was applied to quantify ERK phosphorylation dynamics in HMEC treated by different doses of EGF at both the peak activation (10 min) and steady state (2 h). At 10 min, the maximal ERK activation was observed with 0.3 ng/mL dose, whereas the maximal steady state level of ERK activation at 2 h was at 3 ng/ml dose, corresponding to 1200 and 9000 occupied receptors, respectively. At 10 min, the maximally activated pTpY isoform represented ~40% of total ERK, falling to less than 10% at 2 h. The time course and dose-response profiles of individual phosphorylated ERK isoforms indicated that singly phosphorylated pT-ERK never increases significantly, while the increase of pY-ERK paralleled that of pTpY-ERK. This data supports for a processive, rather than distributed, model of ERK phosphorylation. The PRISM-SRM quantification of protein phosphorylation illustrates the potential for simultaneous quantification of multiple PTMs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗