Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data assembly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Ultra-Pure, High Endurance Liquid Bladder with Volume Sensor for Space Applications

The NASA Portable Life Support System (PLSS) for the Exploration Extravehicular Mobility Unit (xEMU) incorporates a Feedwater Supply Assembly (FSA) to store consumable cooling water. The FSA accepts pure water prior to each Extra-Vehicular Activity (EVA), then supplies this water to a membrane evaporator at ambient suit pressure during the eight hour EVA. The FSA must function reliably for hundreds of EVAs over 15 years of service without introducing contamination that may accumulate and foul the membrane. We present a unique design that combines the benefits of a flexible fluoropolymer bladder with the strength and convenience of a rigid tank, providing an ultra-pure, ambient-pressure reservoir with fill-drain cycle life exceeding 3000, internal pressure tolerance exceeding 100 psi, high volumetric efficiency, near-zero dead volume, optical transparency for visual inspection, simplified mounting, and very low mass. We also incorporate a novel volume sensor suitable for both microgravity and arbitrarily accelerated environments and capable of real-time monitoring with accuracy on the order of 2.5% full scale. Analytical predictions are supported by experimental test data from a mature subscale prototype.

PLSS Portable Life Support System FSA Feedwater Su↗

DFTT report for Signal Analysis (2023)

The Detection Framework Testbed and Toolkit (DFTT) is a database and associated java programs intended to facilitate the development and testing of algorithms for operating suites of correlation and subspace detectors. This framework is a generalization of the system described in Harris and Dodge (2011) and Dodge and Harris (2016). DFTT allows retrospective processing of sequences of data using various system configurations. Results are saved in a database, so it is easy to compare the results obtained using different configurations of the system. The principal software components of DFTT are the ConfigCreator, the framework_runner and the Builder program. ConfigCreator assembles the files necessary to define a particular configuration used for processing. The framework_runner operates suites of detectors and saves the results in an Oracle™ database. Builder allows visual examination of templates and detected signals and allows editing and creation of detectors. In addition, there are tools for importing continuous data into the database. DFTT is licensed under the MIT license and has LLNL release number LLNL-CODE-801881. In the current fiscal year DFTT has been used in two different projects. The first (NTL-funded) project investigates the feasibility of screening nuisance detections using correlation detectors. The second (GNEM-funded) project seeks to extend the results of Harris and Dodge (2021) to 3- D sources and multiple stations. Each of these efforts required that additional functionality be added to DFTT. In this report I will summarize the enhancements to DFTT in the context of the relevant research effort.

58 GEOSCIENCES↗

A comparison of low-gravity measurements on-board Columbia during STS-40

The first NASA Spacelab Life Sciences mission (SLS-1) flew 5 Jun. to 14 Jun. 1991 on the orbiter Columbia (STS-40). The purpose of the mission was to investigate the human body's adaptation to the low-gravity conditions of space flight and the body's readjustment after the mission to the 1 g environment of earth. In addition to the life sciences experiments manifested for the Spacelab module, a variety of experiments in other scientific disciplines flew in the Spacelab and in Get Away Special (GAS) Canisters on the GAS Bridge Assembly. Several principal investigators designed and flew specialized accelerometer systems to better assess the results of their experiments by means of a low-gravity environment characterization. This was also the first flight of the NASA Microgravity Science and Applications Division (MSAD) sponsored Space Acceleration Measurement System (SAMS) and the first flight of the NASA Orbiter Experiments Office (OEX) sponsored Orbital Acceleration Research Experiment accelerometer (OARE). A brief introduction to seven STS-40 accelerometer systems are presented and the resulting data are discussed and compared. During crew sleep periods, acceleration magnitudes in the 10(exp -6) to 10(exp -5) g range were recorded in the Spacelab module and on the GAS Bridge Assembly. Magnitudes increased to the 10(exp -4) g level during periods of nominal crew activity. Vernier thruster firings caused acceleration shifts on the order of 10(exp -4) g and primary thruster firings caused accelerations as great as 10(exp -2) g. Frequency domain analysis revealed typical excitation of Orbiter and Spacelab structural modes at 3.5, 4.7, 5.2, 6.2, 7, and 17 Hz.

Rogers, Melissa J. B.↗

Methods for Quantitative Thermal Analysis of Lithium Solid-State and Beyond Battery Safety

The use of differential scanning calorimetry (DSC) to measure the thermal behavior of individual components and electrolyte/electrode combinations is common. However, here we focus on DSC tests on an anode, cathode, and electrolyte (ACE) component combination over a temperature range that includes many of the phase transitions and key reactions (i.e., to 500 °C) that contribute to thermal runaway. This method can help quantify the complex reaction network in a full cell, thereby informing potential safety issues. Here, we used DSC heat flow data from a solid-state Li 0.43 CoO 2 +C+PVDF | LLZO | Li metal ACE sample and its components to quantify key factors affecting results. We focused on three areas: (1) ACE sample preparation and assembly in DSC pans, (2) DSC measurement parameters, and (3) heat flow analysis. Key points include the choice of component ratios (e.g., commercially relevant N:P capacity ratio), the importance of conductive carbon and binder, type of pan used, DSC ramp rate, and integration method used when dealing with broad and overlapping exothermic peaks. This work deepens the scientific basis and best practices for obtaining heat flow data from ACE samples for early-stage evaluation of solid-state and beyond battery safety.

25 ENERGY STORAGE↗

Global Nonlinear Parametric Modeling with Application to F-16 Aerodynamics

A global nonlinear parametric modeling technique is described and demonstrated. The technique uses multivariate orthogonal modeling functions generated from the data to determine nonlinear model structure, then expands each retained modeling function into an ordinary multivariate polynomial. The final model form is a finite multivariate power series expansion for the dependent variable in terms of the independent variables. Partial derivatives of the identified models can be used to assemble globally valid linear parameter varying models. The technique is demonstrated by identifying global nonlinear parametric models for nondimensional aerodynamic force and moment coefficients from a subsonic wind tunnel database for the F-16 fighter aircraft. Results show less than 10% difference between wind tunnel aerodynamic data and the nonlinear parameterized model for a simulated doublet maneuver at moderate angle of attack. Analysis indicated that the global nonlinear parametric models adequately captured the multivariate nonlinear aerodynamic functional dependence.

Morelli, Eugene A.↗

Global Nonlinear Parametric Modeling with Application to F-16 Aerodynamics

A global nonlinear parametric modeling technique is described and demonstrated. The technique uses multivariate orthogonal modeling functions generated from the data to determine nonlinear model structure, then expands each retained modeling function into an ordinary multivariate polynomial. The final model form is a finite multivariate power series expansion for the dependent variable in terms of the independent variables. Partial derivatives of the identified models can be used to assemble globally valid linear parameter varying models. The technique is demonstrated by identifying global nonlinear parametric models for nondimensional aerodynamic force and moment coefficients from a subsonic wind tunnel database for the F-16 fighter aircraft. Results show less than 10% difference between wind tunnel aerodynamic data and the nonlinear parameterized model for a simulated doublet maneuver at moderate angle of attack. Analysis indicated that the global nonlinear parametric models adequately captured the multivariate nonlinear aerodynamic functional dependence.

Morelli, Eugene A.↗

Extension of SCALE/Sampler’s sensitivity analysis

Nuclear data are a major source of uncertainties in reactor physics calculations. The propagation of nuclear data uncertainties to important system responses is instrumental when determining appropriate safety margins in reactor safety analyses. It is also important to understand the major contributors to the observed uncertainties to make recommendations for further measurements and evaluations and aid in the understanding of the studied system. The SCALE code system allows for nuclear data uncertainty analysis based on the random sampling approach as implemented in SCALE’s Sampler sequence. Sampler was recently extended by a sensitivity analysis in terms of the calculation of two correlation-based sensitivity indices. This analysis allows for the identification of the top contributing nuclear reactions to any analyzed output uncertainty. This paper presents the sensitivity indices, along with their interpretation and limitations. It demonstrates the application in an eigenvalue and decay heat analysis for a boiling water reactor fuel assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring important upgrades to the Compact Muon Solenoid (CMS) to handle an increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.] (ORCID:0009000151↗

Quality Control of Silicon Sensor Modules for Particle Detectors

The High-Luminosity Large Hadron Collider (HL-LHC) will produce a higher rate of particle collisions than the current Large Hadron Collider (LHC), requiring significant upgrades to the Compact Muon Solenoid (CMS) to handle the increased amount of data. An important upgrade is the Phase-2 Outer Tracker Upgrade, which consists of 13,000 silicon sensor modules made of two parallel silicon sensors and readout electronics. These modules undergo careful quality control checks both during and after module assembly to ensure precise and reliable detector performance. This project focuses on precision testing for quality control of silicon sensor modules at Fermilab. Hands-on work includes visual inspection, current-voltage testing, module testing, and ultraviolet (UV) light exposure of modules showing abnormal current-voltage behavior. The ultraviolet exposure process improves the abnormal sensor readout data by placing the selected sensor side of the module directly under the UV light inside a controlled box. In addition to laboratory testing and ultraviolet experiments, I developed a Python-based data tool that connects to a module database and allows selected testing conditions and module information to be retrieved and displayed efficiently. These different testing procedures, experimental processes, and computational tools support the broader goal of identifying module issues and improving modules that will be used in the CMS Outer Tracker Phase-2 Upgrade.

Siddiqui, Hooriya [DuPage Coll.; Fermilab] (ORCID:↗

Blind Modeling Validation Exercises Using the Horizontal Dry Cask Simulator

The U.S. Department of Energy (DOE) established a need to understand the thermal-hydraulic properties of dry storage systems for commercial spent nuclear fuel (SNF) in response to a shift towards the storage of high-burnup (HBU) fuel (> 45 gigawatt days per metric ton of uranium, or GWd/MTU). This shift raises concerns regarding cladding integrity, which faces increased risk at the higher temperatures within spent fuel assemblies present within HBU fuel compared to low-burnup fuel (≤ 45 GWd/MTU). A dry cask simulator (DCS) was built at Sandia National Laboratories (SNL) in Albuquerque, New Mexico to produce validation-quality data that can be used to test the accuracy of the modeling used to predict cladding temperatures. These temperatures are critical to evaluating cladding integrity throughout the storage cycle of commercial spent nuclear fuel. A model validation exercise was previously carried out for the DCS in a vertical configuration. Lessons learned during the previous validation exercise have been applied to a new, blind study using a horizontal dry cask simulator (HDCS). Three modeling institutions – the Nuclear Regulatory Commission (NRC), Pacific Northwest National Laboratory (PNNL), and Empresa Nacional del Uranio, S.A., S.M.E. (ENUSA) – were granted access to the input parameters from the DCS Handbook, SAND2017-13058R, and results from a limited data set from the horizontal BWR dry cask simulator tests reported in the HDCS update report, SAND2019-11688R. With this information, each institution was tasked to calculate peak cladding temperatures and air mass flow rates for ten HDCS test cases. Axial as well as vertical and horizontal transverse temperature profiles were also calculated. These calculations were done using modeling codes (ANSYS/Fluent, STAR-CCM+, or COBRA-SFS), each with their own unique combination of modeling assumptions and boundary conditions. For this validation study, the ten test cases of the horizontal dry cask simulator were defined by three independent variables – fuel assembly decay heat (0.5 kW, 1 kW, 2.5 W, and 5 kW), internal backfill pressure (100 kPa and 800 kPa), and backfill gas (helium and air). The plots provided in Chapter 3 of this report show the axial, vertical, and horizontal temperature profiles obtained from the dry cask simulator experiments in the horizontal configuration and the corresponding models used to describe the thermal-hydraulic behavior of this system. The tables provided in Chapter 3 illustrate the closeness of fit of the model data to the experiment data through root mean square (RMS) calculations of the error in peak cladding temperatures (PCTs), PCT axial locations, axial temperature profiles, vertical and horizontal temperature profiles at two different axial locations, and air mass flow rates for the ten test cases, normalized by the experimental results. The model results are assigned arbitrary model numbers to retain anonymity. Due to the relatively flat axial temperature profiles, small temperature gradients resulted in large deviations of all models’ PCT axial location from the experimental PCT axial location. When the PCT axial location error is excluded in the calculation of the combined RMS of the normalized errors that considers PCT, the temperature profiles, and the air mass flow rates, the model data fits the experimental data to within 5%. When the vault information is excluded, the model data fits the experimental data to within 2.5%. An error analysis was developed further for one model, using the model and experimental uncertainties in each validation parameter to calculate validation uncertainties. The uncertainties for each parameter were used to define quantifiable validation criteria. For this analysis, the model was considered validated for a given comparison metric if the normalized error in that metric divided by the validation uncertainty was less than or equal to 1. When considering the combined RMS of the normalized errors of all metrics divided by their validation uncertainties, the model was found to have satisfied the criterion for model validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimating the Ultraviolet Emission of M Dwarfs with Exoplanets from Ca ii and Hα

M dwarf stars are excellent candidates around which to search for exoplanets, including temperate, Earth-sized planets. To evaluate the photochemistry of the planetary atmosphere, it is essential to characterize the UV spectral energy distribution of the planet's host star. This wavelength regime is important because molecules in the planetary atmosphere such as oxygen and ozone have highly wavelength-dependent absorption cross sections that peak in the UV (900–3200 Å). We seek to provide a broadly applicable method of estimating the UV emission of an M dwarf, without direct UV data, by identifying a relationship between noncontemporaneous optical and UV observations. Our work uses the largest sample of M dwarf star far- and near-UV observations yet assembled. We evaluate three commonly observed optical chromospheric activity indices—Hα equivalent widths and log(10) L(Hα)/L(bol), and the Mount Wilson Ca ii H&K S and R'(HK) indices—using optical spectra from the HARPS, UVES, and HIRES archives and new HIRES spectra. Archival and new Hubble Space Telescope COS and STIS spectra are used to measure line fluxes for the brightest chromospheric and transition region emission lines between 1200 and 2800 Å. Our results show a correlation between UV emission-line luminosity normalized to the stellar bolometric luminosity and Ca ii R'(HK) with standard deviations of 0.31–0.61 dex (factors of ∼2–4) about the best-fit lines. We also find correlations between normalized UV line luminosity and Hα log(10) L(Hα)/L(bol) and the S index. These relationships allow one to estimate the average UV emission from M0 to M9 dwarfs when UV data are not available.

Katherine Melbourne↗

Progress on the reevaluation and validation of the n+233U neutron cross sections

The set of 233 U resonance parameters of the ENDF/B-VIII.0 nuclear data library was adopted from the previous ENDF/B-VII.1 evaluation using the external levels to update the thermal values. Adoption of IAEA 2017 thermal standards ( σ f = 533.0 ± 2.2 b, σ c = 44.9 ± 0.9 b, and ν ‾ tot = 2.487 ± 0.011 ) and of the IAEA-recommended thermal-neutron induced prompt fission neutron spectrum (PFNS) with average PFNS energy of 2.030 ± 0.013 MeV requires a re-evaluation of 233 U neutron cross sections in the resolved resonance region. A newly produced evaluation is being tested on benchmarks carefully selected from the Handbook of International Criticality Safety Benchmark Experiments (ICSBEP) which are highly sensitive to 233 U data. An important goal of this work was to eliminate the strong negative gradient of the calculated effective multiplication factors with respect to the epithermal fission fraction observed in the validation of the ENDF/B-VIII.0 library for those assemblies. A significant improvement in integral performance of critical 233 U solutions is observed for the newly proposed evaluation. Further work addressing the fast neutron region is needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimating the Ultraviolet Emission of M Dwarfs with Exoplanets from Ca ii and Hα

M dwarf stars are excellent candidates around which to search for exoplanets, including temperate, Earth-sized planets. To evaluate the photochemistry of the planetary atmosphere, it is essential to characterize the UV spectral energy distribution of the planet’s host star. This wavelength regime is important because molecules in the planetary atmosphere such as oxygen and ozone have highly wavelength-dependent absorption cross sections that peak in the UV (900–3200 Å). We seek to provide a broadly applicable method of estimating the UV emission of an M dwarf, without direct UV data, by identifying a relationship between noncontemporaneous optical and UV observations. Our work uses the largest sample of M dwarf star far- and near-UV observations yet assembled. We evaluate three commonly observed optical chromospheric activity indices—Hα equivalent widths and log{sub 10} L Hα /L bol , and the Mount Wilson Ca ii H&K S and R HK ' indices—using optical spectra from the HARPS, UVES, and HIRES archives and new HIRES spectra. Archival and new Hubble Space Telescope COS and STIS spectra are used to measure line fluxes for the brightest chromospheric and transition region emission lines between 1200 and 2800 Å. Our results show a correlation between UV emission-line luminosity normalized to the stellar bolometric luminosity and Ca ii R HK ' with standard deviations of 0.31–0.61 dex (factors of ~2–4) about the best-fit lines. We also find correlations between normalized UV line luminosity and Hα log 10 L Hα /L bol and the S index. These relationships allow one to estimate the average UV emission from M0 to M9 dwarfs when UV data are not available.

79 ASTRONOMY AND ASTROPHYSICS↗

Updates to the n+ 63,65 Cu RRR+URR Evaluations [Slides]

This work updates neutron reactions on 63,65 Cu. It also discusses the motivations of the research which is to correct deficiencies in benchmark performance since critical assembly configurations use Cu as a reflector. This presentation discusses the incorporation of URR parameters fit to 2017 63 Cu(n, γ) measurement by Weigand et al., as well as preliminary work on angular distributions and states that validation against copper-sensitive ICSBEP benchmarks is ongoing. The presentation concludes by stating that R -matrix analysis coupled to consistent average parameters used in the URR have been performed for 63,65 Cu isotopes, that future work will focus on the angular distributions, and that an analysis of additional data measured on natural Cu sample is in progress.

07 ISOTOPE AND RADIATION SOURCES↗

Unreal Engine Testbed for Computer Vision of Tall Lunar Tower Assembly

The Tall Lunar Tower project at the NASA Langley Research Center is focused on the design, modeling, fabrication, and testing of a supervised autonomously assembly engineering development unit for tall lunar towers. The lunar south pole environment poses many challenges for robotic assembly of the tall tower, particularly to computer vision camera systems due to a high-contrast lighting environment. This paper will present an Unreal Engine 5 video game engine Lunar South Pole Lighting Testbed to simulate realistic lunar lighting conditions for synthetic image generation. The fidelity of the simulation environment is investigated by comparing the accuracy of computer vision models trained using synthetic image data and trained from real image data collected in a lunar analog environment.

Unreal Engine↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SAGE III ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2π steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the ight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

SAGE III/ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2pi steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the flight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗