Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Correction to: Hesperetin induces the apoptosis of hepatocellular carcinoma cells via mitochondrial pathway mediated by the increased intracellular reactive oxygen species, ATP and calcium

The original version of this article unfortunately contained a mistake. During final figure preparation and manuscript submission, the similar graphs (Fig. 6c) in different papers were accidentally switched. It was subsequently noted in a further review that Fig. 2a does not match with the hesperetin concentration. The corrected figures and graphs are herein (Figs. 2a, 6c). This correction does not affect the results or conclusions of the original paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction to: ACC/AATS/AHA/ASE/ASNC/SCAI/SCCT/STS 2017 Appropriate Use Criteria for Coronary Revascularization in Patients With Stable Ischemic Heart Disease

To more clearly reflect the relationship between iFR (instantaneous wave-free ratio) and FFR (fractional flow reserve), this Correction document highlights the following changes to the original document published in the Journal of Nuclear Cardiology; the version available at JACC [1] has been updated to reflect the changes, with JACC’s Correction document available at [2].

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction to: The effect of beta blocker withdrawal on adenosine myocardial perfusion imaging

Regrettably the original version of the above article contained errors in Table 2 and wrong values in the text. The corrected table is presented here and the values which have been corrected now appear in bold text. Page 1223 abstract Global MBF showed an increase from 180.2 ± 59.9 to 193.6 ± 60.8 mL minute/100 g (P = .002) after beta blocker withdrawal. Page 1225 Mean systolic and mean diastolic blood pressure during adenosine were nearly identical (P = .77 and P = .79) with and without beta blocker. Mean heart rate and mean RPP during adenosine significantly increased after beta blocker withdrawal by 15.2% ± 17% (P = .001) and 16.2% ± 23% (P = .004), respectively. Page 1226 The data are listed in Table 2, lower third. Global MBF showed a significant increase by 7.4% ± 10% (P = .002) after beta blocker withdrawal. The individual data are depicted in Figure 1. All but three patients had a lower global MBF without beta blocker than with. The segmental MBF values (Figure 2) demonstrated a strong correlation over the entire range of perfusion values. The average effect was a slight perfusion shift of about 1015 mL minute-1/100 g in the range of 100-300 mL minute-1/100 g. The mCR under adenosine declined by 8.1% ± 11% (P = .038) and the normalized RPP by 16.2% ± 21% (P = .004) after betablocker discontinuation. Table 2 Hemodynamic response under adenosine, perfusion, and left-ventricular function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An AFM Dynamic Contact Model with Finite Thickness Correction to Study Micro-Rheology of Biological Cells

One of the major sources of error in Atomic Force Microscopy based Force Spectroscopic studies is bottom substrate effect, which comes due to assumption of infinite sample thickness. In the present work, anew experimentally validated mathematical correction for finite thickness of thesample is incorporated into a dynamic indentation model. This model is an extension of Sneddon’s static indentation contact model developed for conical tip indenters by incorporating the tip geometric effects, correction to hydrodynamic drag, viscoelastic nature of the sample and its finite thickness. The new model is applied to extract the viscoelastic properties of primary mesenchymal stem cells (MSC’s) extracted from human bone marrow and HCT-116 aggressive epithelial colorectal cancer cells. The micro-rheological studies indicated the presence of profound influence of infinite thickness assumption depending upon indentation depth and sample thickness at the point of indentation. The present model nullified this error and provided a better estimate of the rheological properties. The tests were conducted over a wide frequency bandwidth (0.5 to 126 Hz) and frequency dependent material properties were analyzed using power law structural damping model. It was found that MSC’s are stiffer and less viscous in nature compared to cancer cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Correction to: Shock Response of Polymethylmethacrylate

Table 1 had incorrect densities for the RH and Poly samples. The correct density for RH samples is 1.1892 ± 0.0003 g/cm 3 . The correct density for Poly samples is 1.1842 ± 0.0004 g/cm 3 . The authors thank Christopher Neel from the Air Force Research Laboratory for bringing this error to our attention. Additionally, there is an error in Eq. (6). 1.7576 × 10 -2 should be 1.7576 × 10 -7 .

36 MATERIALS SCIENCE↗

In vivo gene correction with targeted sequence substitution through microhomology-mediated end joining

Highlights: • A novel microhomology mediated end joining (MMEJ) gene correction method was tested. • MMEJ resulted in precise targeted sequence substitution (TSS) in vitro and in vivo. • MMEJ-TSS showed superior efficiency than homology-directed repair (HDR) in vitro. • MMEJ-TSS resulted in the survival of mice model of hereditary tyrosinemia in vivo. • MMEJ-TSS could overcome the limitations of HDR for gene therapy. Genome editing technology using programmable nucleases has rapidly evolved in recent years. The primary mechanism to achieve precise integration of a transgene is mainly based on homology-directed repair (HDR). However, an HDR-based genome-editing approach is less efficient than non-homologous end-joining (NHEJ). Recently, a microhomology-mediated end-joining (MMEJ)-based transgene integration approach was developed, showing feasibility both in vitro and in vivo. We expanded this method to achieve targeted sequence substitution (TSS) of mutated sequences with normal sequences using double-guide RNAs (gRNAs), and a donor template flanking the microhomologies and target sequence of the gRNAs in vitro and in vivo. Our method could realize more efficient sequence substitution than the HDR-based method in vitro using a reporter cell line, and led to the survival of a hereditary tyrosinemia mouse model in vivo. The proposed MMEJ-based TSS approach could provide a novel therapeutic strategy, in addition to HDR, to achieve gene correction from a mutated sequence to a normal sequence.

60 APPLIED LIFE SCIENCES↗

Effects of operator splitting and low Mach-number correction in turbulent mixing transition simulations

In this paper, transition and turbulence decay with the Taylor–Green vortex have been effectively used to demonstrate emulation of high Reynolds-number ( R e ) physical dissipation through numerical convective effects of various non-oscillatory finite-volume algorithms for implicit large eddy simulation (ILES), e.g. using the Godunov-based Eulerian adaptive mesh refinement code xRAGE. The inverse-chevron shock tube experiment simulations have been also used to assess xRAGE based ILES for shock driven turbulent mixing, compared with available simulation and laboratory data. The previous assessments are extended to evaluate new directionally-unsplit high-order algorithms in xRAGE, including a correction to address the well-known issue of excessive numerical diffusion of shock-capturing (e.g., Godunov-type) schemes for low Mach numbers. The unsplit options for hydrodynamics in xRAGE are discussed in detail, followed by fundamental tests with representative shock problems. Basic issues of transition to turbulence and turbulent mixing are discussed, and results of simulations of high- R e turbulent flow and mixing in canonical test cases are reported. Finally, compared to the directional-split cases, and for each grid resolution considered, unsplit results exhibit transition to turbulence with much higher effective R e —and significantly more so with the low Mach number correction.

97 MATHEMATICS AND COMPUTING↗

Polarization loss correction derived from hydrogen local-resistance measurement in low Pt-loaded polymer-electrolyte fuel cells

The reduction of platinum-loading on the cathode side of polymer-electrolyte fuel cells leads to a poorly understood increase in mass-transport resistance (MTR) at high current densities. This local resistance was measured using a facile hydrogen-pump technique with dilute active gases for membrane-electrode assemblies with catalyst layers of varying platinum-loading (0.03-0.40 mgPt/cm²). Furthermore, polarization curves in H 2 /air were measured and corrected for the overpotential caused by the increased MTR for low loadings on the air side due to the reduced concentration of reactant gas at the catalyst surface. The difference in performance after correction for all resistances including the MTR is minor, suggesting its origin to be diffusive in nature, and proving the meaningfulness of the facile hydrogen-pump technique for the characterization of the cathode catalyst layer under defined operation conditions.

30 DIRECT ENERGY CONVERSION↗

Daily Isocenter Correction With Electromagnetic-Based Localization Improves Target Coverage and Rectal Sparing During Prostate Radiotherapy

Purpose: To evaluate dosimetric consequences of daily isocenter correction during prostate cancer radiation therapy using the Calypso 4D localization system. Methods and Materials: Data were analyzed from 28 patients with electromagnetic transponders implanted in their prostates for daily target localization and tracking. Treatment planning isocenters were recorded based on the values of the vertical, longitudinal, and lateral axes. Isocenter location obtained via alignment with skin tattoos was compared with that obtained via the electromagnetic localization system. Daily isocenter shifts, based on the isocenter location differences between the two alignment methods in each spatial axis, were calculated for each patient over their entire course. The mean isocenter shifts were used to determine dosimetric consequences of treatment based on skin tattoo alignments alone. Results: The mean += SD of the percentages of treatment days with shifts beyond += 0.5 cm for vertical, longitudinal and lateral shifts were 62% += 28%, 35% += 26%, and 38% +=21%, respectively. If daily electromagnetic localization was not used, the excess in prescribed dose delivered to 70% of the rectum was 10 Gy and the deficit in prescribed dose delivered to 95% of the planning target volume was 10 Gy. The mean isocenter shift was not associated with the volumes of the prostate, rectum, or bladder, or with patient body mass index. Conclusions: Daily isocenter localization can reduce the treatment dose to the rectum. Correcting for this variability could lead to improved dose delivery, reduced side effects, and potentially improved treatment outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Verification Using Monte Carlo Calculations for Tissue Heterogeneity-Corrected Conformal Treatment Plans Following RTOG 0813 Dosimetric Criteria for Lung Cancer Stereotactic Body Radiotherapy

Purpose: The recently activated Radiation Therapy Oncology Group (RTOG) studies of stereotactic body radiation therapy (SBRT) for non-small-cell lung cancer (NSCLC) require tissue density heterogeneity correction, where the high and intermediate dose compliance criteria were established based on superposition algorithm dose calculations. The study was aimed at comparing superposition algorithm dose calculations with Monte Carlo (MC) dose calculations for SBRT for NSCLC and to evaluate whether compliance criteria need to be adjusted for MC dose calculations. Methods and Materials: Fifteen RTOG 0236 study sets were used. The planning tumor volumes (PTV) ranged from 10.7 to 117.1 cm{sup 3}. SBRT conformal treatment plans were generated using XiO (CMS Inc.) treatment planning software with superposition algorithm to meet the dosimetric high and intermediate compliance criteria recommended by the RTOG 0813 protocol. Plans were recalculated using the MC algorithm of a Monaco (CMS, Inc.) treatment planning system. Tissue density heterogeneity correction was applied in both calculations. Results: Overall, the dosimetric quantities of the MC calculations have larger magnitudes than those of the superposition calculations. On average, R{sub 100%} (ratio of prescription isodose volume to PTV), R{sub 50%} (ratio of 50% prescription isodose volume to PTV), D{sub 2cm} (maximal dose 2 cm from PTV in any direction as a percentage of prescription dose), and V{sub 20} (percentage of lung receiving dose equal to or larger than 20 Gy) increased by 9%, 12%, 7%, and 18%, respectively. In the superposition plans, 3 cases did not meet criteria for R{sub 50%} or D{sub 2cm}. In the MC-recalculated plans, 8 cases did not meet criteria for R{sub 100%}, R{sub 50%}, or D{sub 2cm}. After reoptimization with MC calculations, 5 cases did not meet the criteria for R{sub 50%} or D{sub 2cm}. Conclusions: Results indicate that the dosimetric criteria, e.g., the criteria for R{sub 50%} recommended by RTOG 0813 protocol, may need to be adjusted when the MC dose calculation algorithm is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the importance of correcting for the uncompensated Ohmic resistance in model experiments of the oxygen reduction reaction.

When measuring the current due to the Oxygen Reduction Reaction (ORR) and hydrogen oxidation reaction (HOR) on Pt and Pt alloys in aqueous electrolyte, it is important to take care of two major sources of error that are relatively easy to correct for. First, when measuring ORR voltammetry, adsorption processes are superimposed on the current. Second, the system resistance causes an Ohmic drop that may have a profound effect on the measured curves, especially at the higher currents close to the diffusion limiting current. More importantly, we show that it also influences the kinetic part of the potential curve in such a way that the Tafel slope may be determined incorrectly when failing to correct for Ohmic drop. Finally, because electrolyte resistance lowers with increasing temperature, failure to compensate for Ohmic.

08 HYDROGEN↗

How to correct relative voxel scale factors for calculations of vector-difference Fourier maps in cryo-EM

The atomic coordinates derived from cryo-electron microscopy (cryo-EM) maps can be inaccurate when the voxel scaling factors are not properly calibrated. Here, we describe a method for correcting relative voxel scaling factors between pairs of cryo-EM maps for the same or similar structures that are expanded or contracted relative to each other. We find that the correction of scaling factors reduces the amplitude differences of Fourier-inverted structure factors from voxel-rescaled maps by up to 20–30%, as shown by two cryo-EM maps of the SARS-CoV-2 spike protein measured at pH 4.0 and pH 8.0. This allows for the calculation of the difference map after properly scaling, revealing differences between the two structures for individual amino acid residues. Unexpectedly, the analysis uncovers two previously overlooked differences of amino acid residues in structures and their local structural changes. Furthermore, we demonstrate the method as applied to two cryo-EM maps of monomeric apo-photosystem II from the cyanobacteria Synechocystis sp. PCC 6803 and Thermosynechococcus elongatus. The resulting difference maps reveal many changes in the peripheral transmembrane PsbX subunit between the two species.

59 BASIC BIOLOGICAL SCIENCES↗

The Accuracy of Inhomogeneity Corrections in Intensity Modulated Radiation Therapy Planning in Philips Pinnacle System

The degree of accuracy of inhomogeneity corrections in a treatment planning system is dependent on the algorithm used by the system. The choice of field size, however, could have an effect on the calculation accuracy as well. There have been several evaluation studies on the accuracy of inhomogeneity corrections used by different algorithms. Most of these studies, however, focus on evaluating the dose in phantom using simplified geometry and open/static fields. This work focuses on evaluating the degree of dose accuracy in calculations involving intensity-modulated radiation therapy (IMRT) fields incident on a phantom containing both lung- and bone-equivalent heterogeneities using 6 and 10 MV beams. IMRT treatment plans were generated using the Philips Pinnacle treatment planning system and delivered to a phantom containing 55 thermoluminescent dosimeter (TLD) locations within the lung and bone and near the lung and bone interfaces with solid water. The TLD readings were compared with the dose predicted by the planning system. We find satisfactory agreement between planned and delivered doses, with an overall absolute average difference between measurement and calculation of 1.2% for the 6 MV and 3.1% for the 10 MV beam with larger variations observed near the interfaces and in areas of high-dose gradient. The results presented here demonstrate that the convolution algorithm used in the Pinnacle treatment planning system produces accurate results in IMRT plans calculated and delivered to inhomogeneous media, even in regions that potentially lack electronic equilibrium.

61 RADIATION PROTECTION AND DOSIMETRY↗

Practical spatial resolution of electron energy loss spectroscopy in aberration corrected scanning transmission elecron microscopy.

The resolution of electron energy loss spectroscopy (EELS) is limited by delocalization of inelastic electron scattering rather than probe size in an aberration corrected scanning transmission electron microscope (STEM). In this study, we present an experimental quantification of EELS spatial resolution using chemically modulated 2 x (LaMnO{sub 3})/2 x (SrTiO{sub 3}) and 2 x (SrVO{sub 3})/2 x (SrTiO{sub 3}) superlattices by measuring the full width at half maxima (FWHM) of integrated Ti M{sub 2,3}, Ti L{sub 2,3}, V L{sub 2,3}, Mn L{sub 2,3}, La N{sub 4,5}, La N{sub 2,3} La M{sub 4,5} and Sr L{sub 3} edges over the superlattices. The EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profile, obtained by curve-fitting, reveals a systematic trend with the energy loss for the Ti, V, and Mn edges. However, the experimental FWHM of the Sr and La edges deviates significantly from the observed experimental tendency. Spatial resolution of aberration corrected STEM/EELS measured for Ti M{sub 2,3}, Ti L{sub 2,3}, V L{sub 2,3}, Mn L{sub 2,3}, La N{sub 4,5}, La N{sub 2,3} La M{sub 4,5} and Sr L{sub 3} edges using oxide superlattices. EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profiles agrees with Egerton's empirical delocalization model for Ti, V, and Mn edges in thin samples. The FWHM of the Sr and La edges is larger than the model's prediction because of scattering by heavy atomic columns.

99 GENERAL AND MISCELLANEOUS↗

β-particle energy-summing correction for β-delayed proton emission measurements

One common approach to studying β-delayed proton emission is to measure the energy of the emitted proton and corresponding nuclear recoil in a double-sided silicon-strip detector (DSSD) after implanting the β-delayed proton-emitting (βp) nucleus. However, in order to extract the proton-decay energy, the measured energy must be corrected for the additional energy implanted in the DSSD by the β-particle emitted from the βp nucleus, an effect referred to here as β-summing. Here, we present an approach to determine an accurate correction for β-summing. Our method relies on the determination of the mean implantation depth of the βp nucleus within the DSSD by analyzing the shape of the total (proton + recoil + β) decay energy distribution shape. We validate this approach with other mean implantation depth measurement techniques that take advantage of energy deposition within DSSDs upstream and downstream of the implantation DSSD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency corrections for factorial moments and cumulants of overlapping sets of particles

In this note we discuss subtleties associated with the efficiency corrections for measurements of off-diagonal cumulants and factorial moments for a situation when one deals with overlapping sets of particles, such as correlations between numbers of protons and positively charged particles. In particular, we discuss the situation commonly encountered in heavy-ion experiments, where first all charges are reconstructed and then protons are selected from these charges by an additional particle identification procedure. We present the efficiency correction formulas for the case when the detection efficiencies follow a binomial distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗