Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Parotid Gland Sparing With Helical Tomotherapy in Head-and-Neck Cancer

Purpose: This study evaluated the ability of helical tomotherapy to spare the function of the parotid glands in patients with head-and-neck cancer by analyzing dose-volume histograms, salivary gland scintigraphy, and quality of life assessment. Methods and Materials: Data from 76 consecutive patients treated with helical tomotherapy (Hi-Art Tomotherapy) at University Hospital Brussel were analyzed. During planning, priority was given to planning target volume (PTV) coverage: {>=}95% of the dose must be delivered to {>=}95% of the PTV. Elective nodal regions received 54 Gy (1.8 Gy/fraction). A dose of 70.5 Gy (2.35 Gy/fraction) was prescribed to the primary tumor and pathologic lymph nodes (simultaneous integrated boost scheme). Objective scoring of salivary excretion was performed by salivary gland scintigraphy. Subjective scoring of salivary gland function was evaluated by the European Organization for Research and Treatment of Cancer quality of life questionnaires Quality of Life Questionnaire-C30 (QLQ-C30) and Quality of Life Questionnaire-Head and Neck 35 (H and N35). Results: Analysis of dose-volume histograms (DVHs) showed excellent coverage of the PTV. The volume of PTV receiving 95% of the prescribed dose (V95%) was 99.4 (range, 96.3-99.9). DVH analysis of parotid gland showed a median value of the mean parotid dose of 32.1 Gy (range, 17.5-70.3 Gy). The median parotid volume receiving a dose <26 Gy was 51.2%. Quality of life evaluation demonstrated an initial deterioration of almost all scales and items in QLQ-C30 and QLQ-H and N35. Most items improved in time, and some reached baseline values 18 months after treatment. Conclusion: DVH analysis, scintigraphic evaluation of parotid function, and quality of life assessment of our patient group showed that helical tomotherapy makes it possible to preserve parotid gland function without compromising disease control. We recommend mean parotid doses of <34 Gy and doses <26 Gy to a maximum 47% of the parotid volume as planning goals. Intensity-modulated radiotherapy should be considered as standard treatment in patients with head-and-neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lymphopenia Association With Gross Tumor Volume and Lung V5 and Its Effects on Non-Small Cell Lung Cancer Patient Outcomes

Purpose: Radiation therapy (RT) can both suppress and stimulate the immune system. We sought to investigate the mechanisms underlying radiation-induced lymphopenia and its associations with patient outcomes in non-small cell lung cancer (NSCLC). Methods and Materials: Subjects consisted of 711 patients who had received definitive RT for NSCLC. A lymphocyte nadir was calculated as the minimum lymphocyte value measured during definitive RT. Associations between gross tumor volumes (GTVs) and lung dose-volume histogram (DVH) parameters with lymphocyte nadirs were assessed with Spearman correlation coefficients. Relationships between lymphocyte nadirs with overall survival (OS) and event free survival (EFS) were evaluated with Kaplan-Meier analysis and compared with log-rank test results. Multivariate regressions were conducted with linear and Cox regression analyses. All variables were analyzed as continuous if possible. Results: Larger GTVs were correlated with lower lymphocyte nadirs regardless of concurrent chemotherapy receipt (with concurrent: r = −0.26, P<.0001; without: r = −0.48, P<.0001). Analyses of lung DVH parameters revealed significant correlations at lower doses (lung V5-V10: P<.0001) that incrementally decreased and became nonsignificant at higher doses (lung V60-V70: P>.05). Of note, no significant associations were detected between GTV and lung DVH parameters with total leukocyte, neutrophil, or monocyte nadirs during RT or with lymphocyte count prior to RT. Multivariate analysis revealed larger GTV (P<.0001), receipt of concurrent chemotherapy (P<.0001), twice-daily radiation fractionation (P=.02), and stage III disease (P=.05) to be associated with lower lymphocyte nadirs. On univariate analysis, patients with higher lymphocyte nadirs exhibited significantly improved OS (hazard ratio [HR] = 0.51 per 10{sup 3} lymphocytes/μL, P=.01) and EFS (HR = 0.46 per 10{sup 3} lymphocytes/μL, P<.0001). These differences held on multivariate analyses, controlling for common disease and treatment characteristics including GTV. Conclusions: Lower lymphocyte nadirs during definitive RT were associated with larger GTVs and worse patient outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Proton Beam Therapy for Ocular Melanoma Using a Novel 3D Treatment Planning Technique

Purpose: We evaluated sparing of normal structures using 3-dimensional (3D) treatment planning for proton therapy of ocular melanomas. Methods and Materials: We evaluated 26 consecutive patients with choroidal melanomas on a prospective registry. Ophthalmologic work-up included fundoscopic photographs, fluorescein angiography, ultrasonographic evaluation of tumor dimensions, and magnetic resonance imaging of orbits. Three tantalum clips were placed as fiducial markers to confirm eye position for treatment. Macula, fovea, optic disc, optic nerve, ciliary body, lacrimal gland, lens, and gross tumor volume were contoured on treatment planning compute tomography scans. 3D treatment planning was performed using noncoplanar field arrangements. Patients were typically treated with 3 fields, with at least 95% of planning target volume receiving 50 GyRBE in 5 fractions. Results: Tumor stage was T1a in 10 patients, T2a in 10 patients, T2b in 1 patient, T3a in 2 patients, T3b in 1 patient, and T4a in 2 patients. Acute toxicity was mild. All patients completed treatment as planned. Mean optic nerve dose was 10.1 Gy relative biological effectiveness (RBE). Ciliary body doses were higher for nasal (mean: 11.4 GyRBE) than temporal tumors (5.8 GyRBE). Median follow-up was 31 months (range: 18-40 months). Six patients developed changes which required intraocular bevacizumab or corticosteroid therapy, but only 1 patient developed neovascular glaucoma. Five patients have since died: 1 from metastatic disease and 4 from other causes. Two patients have since required enucleation: 1 due to tumor and 1 due to neovascular glaucoma. Conclusions: 3D treatment planning can be used to obtain appropriate coverage of choroidal melanomas. This technique is feasible with relatively low doses to anterior structures, and appears to have acceptable rates of local control with low risk of enucleation. Further evaluation and follow-up is needed to determine optimal dose-volume relationships for organs at risk to decrease complications rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Distributed Trajectory-Oriented Approach to Managing Traffic Complexity

In order to handle the expected increase in air traffic volume, the next generation air transportation system is moving towards a distributed control architecture, in which ground-based service providers such as controllers and traffic managers and air-based users such as pilots share responsibility for aircraft trajectory generation and management. While its architecture becomes more distributed, the goal of the Air Traffic Management (ATM) system remains to achieve objectives such as maintaining safety and efficiency. It is, therefore, critical to design appropriate control elements to ensure that aircraft and groundbased actions result in achieving these objectives without unduly restricting user-preferred trajectories. This paper presents a trajectory-oriented approach containing two such elements. One is a trajectory flexibility preservation function, by which aircraft plan their trajectories to preserve flexibility to accommodate unforeseen events. And the other is a trajectory constraint minimization function by which ground-based agents, in collaboration with air-based agents, impose just-enough restrictions on trajectories to achieve ATM objectives, such as separation assurance and flow management. The underlying hypothesis is that preserving trajectory flexibility of each individual aircraft naturally achieves the aggregate objective of avoiding excessive traffic complexity, and that trajectory flexibility is increased by minimizing constraints without jeopardizing the intended ATM objectives. The paper presents conceptually how the two functions operate in a distributed control architecture that includes self separation. The paper illustrates the concept through hypothetical scenarios involving conflict resolution and flow management. It presents a functional analysis of the interaction and information flow between the functions. It also presents an analytical framework for defining metrics and developing methods to preserve trajectory flexibility and minimize its constraints. In this framework flexibility is defined in terms of robustness and adaptability to disturbances and the impact of constraints is illustrated through analysis of a trajectory solution space with limited degrees of freedom and in simple constraint situations involving meeting multiple times of arrival and resolving a conflict.

Idris, Husni↗

Single-Fraction Proton Beam Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations

Purpose/Objective(s): To evaluate the obliteration rate and potential adverse effects of single-fraction proton beam stereotactic radiosurgery (PSRS) in patients with cerebral arteriovenous malformations (AVMs). Methods and Materials: From 1991 to 2010, 248 consecutive patients with 254 cerebral AVMs received single-fraction PSRS at our institution. The median AVM nidus volume was 3.5 cc (range, 0.1-28.1 cc), 23% of AVMs were in critical/deep locations (basal ganglia, thalamus, or brainstem), and the most common prescription dose was 15 Gy(relative biological effectiveness [RBE]). Univariable and multivariable analyses were performed to assess factors associated with obliteration and hemorrhage. Results: At a median follow-up time of 35 months (range, 6-198 months), 64.6% of AVMs were obliterated. The median time to total obliteration was 31 months (range, 6-127 months), and the 5-year and 10-year cumulative incidence of total obliteration was 70% and 91%, respectively. On univariable analysis, smaller target volume (hazard ratio [HR] 0.78, 95% confidence interval [CI] 0.86-0.93, P<.0001), smaller treatment volume (HR 0.93, 95% CI 0.90-0.96, P<.0001), higher prescription dose (HR 1.16, 95% CI 1.07-1.26, P=.001), and higher maximum dose (HR 1.14, 95% CI 1.05-1.23, P=.002) were associated with total obliteration. Deep/critical location was also associated with decreased likelihood of obliteration (HR 0.68, 95% CI 0.47-0.98, P=.04). On multivariable analysis, critical location (adjusted HR [AHR] 0.42, 95% CI 0.27-0.65, P<.001) and smaller target volume (AHR 0.81, 95% CI 0.68-0.97, P=.02) remained associated with total obliteration. Posttreatment hemorrhage occurred in 13 cases (5-year cumulative incidence of 7%), all among patients with less than total obliteration, and 3 of these events were fatal. The most common complication was seizure, controlled with medications, both acutely (8%) and in the long term (9.1%). Conclusions: The current series is the largest modern series of PSRS for cerebral AVMs. PSRS can achieve a high obliteration rate with minimal morbidity. Post-treatment hemorrhage remains a potentially fatal risk among patients who have not yet responded to treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Response for Stereotactic Body Radiotherapy in Early-Stage Non-Small-Cell Lung Cancer

Purpose: To compare the efficacy of three lung stereotactic body radiotherapy (SBRT) regimens in a large institutional cohort. Methods: Between 2004 and 2009, 130 patients underwent definitive lung cancer SBRT to a single lesion at the Mallinckrodt Institute of Radiology. We delivered 18 Gy Multiplication-Sign 3 fractions for peripheral tumors (n = 111) and either 9 Gy Multiplication-Sign 5 fractions (n = 8) or 10 Gy Multiplication-Sign 5 fractions (n = 11) for tumors that were central or near critical structures. Univariate and multivariate analysis of prognostic factors was performed using the Cox proportional hazard model. Results: Median follow-up was 11, 16, and 13 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 groups, respectively. Local control statistics for Years 1 and 2 were, respectively, 75% and 50% for 9 Gy Multiplication-Sign 5, 100% and 100% for 10 Gy Multiplication-Sign 5, and 99% and 91% for 18 Gy Multiplication-Sign 3. Median overall survival was 14 months, not reached, and 34 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 treatments, respectively. No difference in local control or overall survival was found between the 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 groups on log-rank test, but both groups had improved local control and overall survival compared with 9 Gy Multiplication-Sign 5. Treatment with 9 Gy Multiplication-Sign 5 was the only independent prognostic factor for reduced local control on multivariate analysis, and increasing age, increasing tumor volume, and poor performance status predicted independently for reduced overall survival. Conclusion: Treatment regimens of 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 seem to be efficacious for lung cancer SBRT and provide superior local control and overall survival compared with 9 Gy Multiplication-Sign 5.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Pressure and Oxidation State on Pnictogen Metal-Silicate Partitioning

The partitioning of trace elements between metal and silicate melts serves as the foundation for understanding the differentiation of a planetary body into a metallic core and silicate mantle. Element activity influences metal-silicate partitioning behavior. Activity coefficients are directly dependent on composition and temperature, and can be indirectly dependent on oxygen fugacity and pressure. Distinguishing the effect of pressure from other variables on the activity coefficients and partitioning is important for understanding the chemical evolution of different planetary bodies during differentiation. In this study, we investigated the influence of pressure on the activity coefficients of Cu, Mo, Pd, Pt, As, Sb, and Bi in Fe-Si metallic liquids. All of these elements exhibit moderate to high activity coefficients in Fe-Si liquids at low pressure, which significantly controls their metal-silicate partitioning behavior. Identifying whether this strong dependence persists at higher pressures is critical to modeling and understanding the chemical consequences of core formation. New experiments at 10 GPa were used to derive activity coefficients for these metals which can be compared to activity coefficients determined at 1 GPa. Experiments were conducted at 10 GPa and 2373K using a 10/5 assembly in the 880-ton multi anvil press at NASA Johnson Space Center. The standard 10/5 COMPRES assembly was slightly modified to accommodate a sample capsule machined from single-crystal MgO that minimizes melt percolation out of the sample volume during the experiment. Experiment starting materials were comprised of 70 wt.% Knippa basalt and 30 wt.% metal. The metal mixture (~85 wt.% Fe) was created by adding the elements of interest (Cu, Mo, Pd, Pt, As, Sb, Bi) to Fe metal powder. Varied amounts of Si metal (0-10 wt.% Si) were added to the metal-silicate mixtures to generate a systematic series of starting materials. For each element, an epsilon interaction parameter in Fe-Si liquid was derived from the results of our 0-10 wt.% Si metal series. To investigate whether pressure influences the trace element activity coefficients in the 1-10 GPa pressure range, we compared our results at 10 GPa to those at 1-4 GPa [1-3]. Our results can also be directly compared to interaction parameters for Au, P, V, Mn, Ga, Zn, Cd, Sn, W, Pb, and Nb previously determined at 10 GPa and 2373K following the same methods [4]. Combined, this suite of interaction parameters will directly inform metal- silicate partitioning between 1 and 10 GPa, and assess whether these values can be extrapolated to modeling differentiation processes at pressures >10 GPa. [1] Righter et al. (2018) GCA 232, 101-123 [2] Righter et al. (2019) MaPS 54, 1379-1394 [3] Steenstra et al. (2020) Icarus, 335, 113391 [4] Righter et al. (2020) Geochem. Persp. Let. 15, 44-49

Kelsey Prissel↗

Local Control, Toxicity, and Cosmesis in Women >70 Years Enrolled in the American Society of Breast Surgeons Accelerated Partial Breast Irradiation Registry Trial

Purpose: The American Society of Breast Surgeons enrolled women in a registry trial to prospectively study patients treated with the MammoSite Radiation Therapy System breast brachytherapy device. The present report examined the outcomes in women aged >70 years enrolled in the trial. Methods and Materials: A total of 1,449 primary early stage breast cancers were treated in 1,440 women. Of these, 537 occurred in women >70 years old. Fisher's exact test was performed to correlate age ({<=}70 vs. >70 years) with toxicity and with cosmesis. The association of age with local recurrence (LR) failure times was investigated by fitting a parametric model. Results: Older women were less likely to develop telangiectasias than younger women (7.9% vs. 12.4%, p = 0.0083). The incidence of other toxicities was similar. Cosmesis was good or excellent in 92% of the women >70 years old. No significant difference was found in LR as a function of age. The 5-year actuarial LR rate with invasive disease for the older vs. younger population was 2.79% and 2.92%, respectively (p = 0.5780). In women >70 years with hormone-sensitive tumors {<=}2 cm who received hormonal therapy (n = 195), the 5-year actuarial rate of LR, overall survival, disease-free survival, and cause-specific survival was 2.06%, 89.3%, 87%, and 97.5%, respectively. These outcomes were similar in women who did not receive hormonal therapy. Women with small, estrogen receptor-negative disease had worse LR, overall survival, and disease-free survival compared with receptor-positive patients. Conclusions: Accelerated partial breast irradiation with the MammoSite radiation therapy system resulted in low toxicity and produced similar cosmesis and local control at 5 years in women >70 years compared with younger women. This treatment should be considered as an alternative to omitting adjuvant radiotherapy for older women with small-volume, early-stage breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Pressure on Trace Element Activity Coefficients in Metal-Silicate Systems

The partitioning of trace elements between metal and silicate melts serves as the foundation for understanding the differentiation of a planetary body into a metallic core and silicate mantle. Element activity influences metal-silicate partitioning behavior. Activity coefficients are directly dependent on composition and temperature, and can be indirectly dependent on oxygen fugacity and pressure. Distinguishing the effect of pressure from other variables on the activity coefficients and partitioning is important for understanding the chemical evolution of different planetary bodies during differentiation. In this study, we investigated the influence of pressure on the activity coefficients of Cu, Mo, Pd, Pt, As, Sb, and Bi in Fe-Si metallic liquids. All of these elements exhibit moderate to high activity coefficients in Fe-Si liquids at low pressure, which significantly controls their metal-silicate partitioning behavior. Identifying whether this strong dependence persists at higher pressures is critical to modeling and understanding the chemical consequences of core formation. New experiments at 10 GPa were used to derive activity coefficients for these metals which can be compared to activity coefficients determined at 1 GPa. Experiments were conducted at 10 GPa and 2373K using a 10/5 assembly in the 880-ton multi-anvil press at NASA Johnson Space Center. The standard 10/5 COMPRES assembly was slightly modified to accommodate a sample capsule machined from single-crystal MgO that minimizes melt percolation out of the sample volume during the experiment. Experiment starting materials were comprised of 70 wt.% Knippa basalt and 30 wt.% metal. The metal mixture (~85 wt.% Fe) was created by adding the elements of interest (Cu, Mo, Pd, Pt, As, Sb, Bi) to Fe metal powder. Varied amounts of Si metal (0-10 wt.% Si) were added to the metal-silicate mixtures to generate a systematic series of starting materials. For each element, an epsilon interaction parameter in Fe-Si liquid was derived from the results of our 0-10 wt.% Si metal series. To investigate whether pressure influences the trace element activity coefficients in the 1-10 GPa pressure range, we compared our results at 10 GPa to those at 1-4 GPa [1-3]. Our results can also be directly compared to interaction parameters for Au, P, V, Mn, Ga, Zn, Cd, Sn, W, Pb, and Nb previously determined at 10 GPa and 2373K following the same methods [4]. Combined, this suite of interaction parameters will directly inform metal-silicate partitioning between 1 and 10 GPa, and assess whether these values can be extrapolated to modeling differentiation processes at pressures >10 GPa.

Kelsey Prissel↗

Robotic Measurement of Holdup Deposit Volume in Gaseous Diffusion Piping to Quantify U-235 Content - 18375

During D and D of old gaseous diffusion uranium enrichment facilities, radiometric assay of U-235 holdup in pipes is a costly, time consuming, and labor-intensive process. Subject to human interpretation using approximate modeling, radiometric assay introduces significant challenges. Taking advantage of routine demolition activities in which D and D cuts pipes open, robotic in-pipe assay is explored. The novel method introduced here generates models of the internal pipe and deposit surface geometries that are used to derive volumetric quantities. The pipe surface is sensed using a non-contact inductive proximity sensor and the deposit surface is sensed using an optical laser triangulation sensor. These sensors are mounted on a spinning disk and driven down the pipe to construct a helical point cloud of discrete measurements. Surfaces are fit to each of the two point clouds to create a watertight volume that represents the holdup. This provides the location and volume per foot of pipe that is used to compare against criticality incredible (CI) thresholds during evaluation. The robotic system collects data autonomously, deploying and returning to the same pipe opening from which it is launched. This provides redundant measurements of the pipe and deposit surfaces as well as odometry used in localization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.

42 ENGINEERING↗

SU-E-T-27: A Dosimetric Evaluation of Boney Anatomy Versus Fiducial Marker Alignment for the Treatment of Prostate Cancer Using Scanned Beam Proton Therapy

Purpose: In prostate proton radiotherapy, three fiducial markers are used for patient daily alignment. However fiducial alignment can change beamline heterogeneity in proton therapy. The purpose of this study is to determine the difference in fiducial and boney anatomy alignment for patient treatment. Methods and materials: Prostate cancer patients who received proton treatment were included in this study. 3 fiducial markers were implanted before the initial CT. All the patients were re-CT’d every 2 weeks to check the fiducial marker position reproducibility as well as dosimetric consistence of target coverage. In geometry study, re-CT were fused to the initial CT base on the boney anatomy and the average fiducial marker displacement was measured the centers of the fiducials. Dosimetrically, the initial plan was recalculated directly to re-CT image set based on the boney alignment and fiducial alignment to determine the difference from daily treatment. Prostate coverage and hotspots were evaluated using the dose to 98% of the CTV (D98) and dose to 2% (D2), respectively. Results: The shift from the initial 6 patient CT image sets resulted in an average change in the fiducial location of 5.70 +/− 3 mm. Dosimetric comparison from a single patient revealed that differences from the planned dose resulted from both boney and fiducial alignment. Planned clinical treatment volume coverage resulted in a D98 of 70.44Gy and D2 of 70.84Gy compared to a D98 of 70.13Gy and D2 70.94Gy for boney alignment and a D98 of 70.08Gy and D2 71.18Gy for fiducial alignment respectively. Conclusion: This study demonstrates that with boney anatomy alignment there is little change to CTV coverage and only slightly worse CTV coverage and hotspot production with fiducial alignment. An increase patient cohort and further investigation is necessary to determine the whether boney alignment can help better control dose heterogeneity.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-02: Planning and Delivery of Fully Dynamic Trajectory Modulated Arc Therapy On Pituitary Adenoma: Dosimetric Advantages Over Conventional Volumetric Modulated Arc Therapy

Purpose: To assess the potential benefit of trajectory modulated arc therapy (TMAT) for treatments of small benign intracranial tumor, pituitary adenoma. Methods: A TMAT planning platform that incorporates complex source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement was used for the study. The platform couples an interactive trajectory generation tool with a VMAT algorithm that performs multi-resolution, progressive sampling MLC optimization on a user-designed trajectory. A continuous couch rotation of 160° angular span with ±20° mini gantry arcs was used to emulate a non-coplanar horizontal arc-like trajectory. Compared to conventional non-coplanar gantry arcs (60°-100° gantry rotation with couch kicks), TMAT limited the unnecessary low to medium dose spread in the anterior and posterior directions, where primary OARs (e.g., brainstem, optic chiasm, optic nerves, and lens) are in close proximity to the targeted pituitary tumor volume. For 5 standard fractionation pituitary adenoma cases (50.4Gy/28fractions), TMAT and non-coplanar VMAT plans were generated and compared under equivalent objectives/constraints. TMAT delivery was implemented and demonstrated on Varian TrueBeam via XML scripts. Results: Both techniques showed good target coverage while OARs were able to meet the constraints on QUANTEC guidelines. Notably, TMAT decreased the dose deposition in the anterior-to-posterior direction surrounding PTV. TMAT significantly reduced the mean doses on brainstem, optic nerves, eyes and lens by 47.29%±13.17%, 28.51%±8.68%, 80.82%±8.71% and 65.38%±19.99% compared with VMAT, all p≤0.01. Percentage reductions of maximum point dose in eyes and lens were 75.68%±10.30% and 70.72%±18.62% respectively for TMAT versus VMAT, all p≤0.01. A representative isocentric TMAT pituitary plan was delivered via an XML script with 200 control points and 282 MUs. Conclusion: Deliverable TMAT plans were achieved in developer mode in TrueBeam. TMAT was shown to be superior for pituitary adenoma irradiation in terms of OARs sparing.

60 APPLIED LIFE SCIENCES↗

SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electron field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.

60 APPLIED LIFE SCIENCES↗

Porous media matric potential and water content measurements during parabolic flight

Control of water and air in the root zone of plants remains a challenge in the microgravity environment of space. Due to limited flight opportunities, research aimed at resolving microgravity porous media fluid dynamics must often be conducted on Earth. The NASA KC-135 reduced gravity flight program offers an opportunity for Earth-based researchers to study physical processes in a variable gravity environment. The objectives of this study were to obtain measurements of water content and matric potential during the parabolic profile flown by the KC-135 aircraft. The flight profile provided 20-25 s of microgravity at the top of the parabola, while pulling 1.8 g at the bottom. The soil moisture sensors (Temperature and Moisture Acquisition System: Orbital Technologies, Madison, WI) used a heat-pulse method to indirectly estimate water content from heat dissipation. Tensiometers were constructed using a stainless steel porous cup with a pressure transducer and were used to measure the matric potential of the medium. The two types of sensors were placed at different depths in a substrate compartment filled with 1-2 mm Turface (calcined clay). The ability of the heat-pulse sensors to monitor overall changes in water content in the substrate compartment decreased with water content. Differences in measured water content data recorded at 0, 1, and 1.8 g were not significant. Tensiometer readings tracked pressure differences due to the hydrostatic force changes with variable gravity. The readings may have been affected by changes in cabin air pressure that occurred during each parabola. Tensiometer porous membrane conductivity (function of pore size) and fluid volume both influence response time. Porous media sample height and water content influence time-to-equilibrium, where shorter samples and higher water content achieve faster equilibrium. Further testing is needed to develop these sensors for space flight applications.

Parabolic Flight↗

Mapping Patterns of Local Recurrence After Pancreaticoduodenectomy for Pancreatic Adenocarcinoma: A New Approach to Adjuvant Radiation Field Design

Purpose: To generate a map of local recurrences after pancreaticoduodenectomy (PD) for patients with resectable pancreatic ductal adenocarcinoma (PDA) and to model an adjuvant radiation therapy planning treatment volume (PTV) that encompasses a majority of local recurrences. Methods and Materials: Consecutive patients with resectable PDA undergoing PD and 1 or more computed tomography (CT) scans more than 60 days after PD at our institution were reviewed. Patients were divided into 3 groups: no adjuvant treatment (NA), chemotherapy alone (CTA), or chemoradiation (CRT). Cross-sectional scans were centrally reviewed, and local recurrences were plotted to scale with respect to the celiac axis (CA), superior mesenteric artery (SMA), and renal veins on 1 CT scan of a template post-PD patient. An adjuvant clinical treatment volume comprising 90% of local failures based on standard expansions of the CA and SMA was created and simulated on 3 post-PD CT scans to assess the feasibility of this planning approach. Results: Of the 202 patients in the study, 40 (20%), 34 (17%), and 128 (63%) received NA, CTA, and CRT adjuvant therapy, respectively. The rate of margin-positive resections was greater in CRT patients than in CTA patients (28% vs 9%, P=.023). Local recurrence occurred in 90 of the 202 patients overall (45%) and in 19 (48%), 22 (65%), and 49 (38%) in the NA, CTA, and CRT groups, respectively. Ninety percent of recurrences were within a 3.0-cm right-lateral, 2.0-cm left-lateral, 1.5-cm anterior, 1.0-cm posterior, 1.0-cm superior, and 2.0-cm inferior expansion of the combined CA and SMA contours. Three simulated radiation treatment plans using these expansions with adjustments to avoid nearby structures were created to demonstrate the use of this treatment volume. Conclusions: Modified PTVs targeting high-risk areas may improve local control while minimizing toxicities, allowing dose escalation with intensity-modulated or stereotactic body radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma Knife Radiosurgery for Treatment of Cerebral Metastases From Non-Small-Cell Lung Cancer

Purpose: To evaluate clinical and physico-dosimetric variables affecting clinical outcome of patients treated with Gamma Knife radiosurgery (GKRS) for brain metastases from non-small cell lung cancer (NSCLC). Methods and Materials: Between 2001 and 2006, 373 patients (298 men and 75 women, median age 65 years) with brain metastases from NSCLC underwent GKRS. All of them had KPS {>=} 60%, eight or fewer brain metastases, confirmed histopathological diagnosis and recent work-up (<3 months). Thirty-five patients belonged to recursive partitioning analysis (RPA) Class I, 307 patients were in RPA Class II, 7 patients were in RPA Class III. Median tumor volume was 3.6 cm{sup 3}. Median marginal dose was 22.5 Gy at 50% isodose.; median 10 Gy and 12 Gy isodose volumes were 30.8 cm{sup 3} and 15.8 cm{sup 3}, respectively. Follow-up with MRI was performed every 3 months. Overall survival data were collected from internal database, telephone interviews, and identifying registries. Results: Mean follow-up after GKRS was 51 months (range, 6 to 96 months); mean overall survival was 14.2 months. Of 373 patients, 29 were alive at time of writing, 104 had died of cerebral progression, and 176 had died of systemic progression. In 64 cases it was not possible to ascertain the cause. Univariate and multivariate analysis were adjusted for the following: RPA class, surgery, WBRT, age, gender, number of lesions, median tumor volume, median peripheral dose, and 10 Gy and 12 Gy volumes. Identified RPA class and overall tumor volume >5 cc were the only two covariates independently predictive of overall survival in patients who died of cerebral progression. Conclusions: Global volume of brain disease should be the main parameter to consider for performing GKRS, which is a first-line therapy for patient in good general condition and controlled systemic disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Studying Turbulence Using Numerical Simulation Databases: Proceedings of the Summer Program - No. 7

The Seventh Summer Program of the Center for Turbulence Research took place in the four-week period, July 5 to July 31, 1998. This was the largest CTR Summer Program to date, involving thirty-six participants from the U. S. and nine other countries. Thirty-one Stanford and NASA-Ames staff members facilitated and contributed to most of the Summer projects. A new feature, and perhaps a preview of the future programs, was that many of the projects were executed on non-NASA computers. These included supercomputers located in Europe as well as those operated by the Departments of Defense and Energy in the United States. In addition, several simulation programs developed by the visiting participants at their home institutions were used. Another new feature was the prevalence of lap-top personal computers which were used by several participants to carry out some of the work that in the past were performed on desk-top workstations. We expect these trends to continue as computing power is enhanced and as more researchers (many of whom CTR alumni) use numerical simulations to study turbulent flows. CTR's main role continues to be in providing a forum for the study of turbulence for engineering analysis and in facilitating intellectual exchange among the leading researchers in the field. Once again the combustion group was the largest. Turbulent combustion has enjoyed remarkable progress in using simulations to address increasingly complex and practically more relevant questions. The combustion group's studies included such challenging topics as fuel evaporation, soot chemistry, and thermonuclear reactions. The latter study was one of three projects related to the Department of Energy's ASCI Program (www.llnl.gov/asci); the other two (rocket propulsion and fire safety) were carried out in the turbulence modeling group. The flow control and acoustics group demonstrated a successful application of the so-called evolution algorithms which actually led to a previously unknown forcing strategy for jets yielding increased spreading rate. A very efficient algorithm for flow in complex geometries with moving boundaries based on the immersed boundary forcing technique was tested with very encouraging results. Also a new strategy for the destruction of aircraft trailing vortices was introduced and tested. The Reynolds Averaged Modeling (RANS) group demonstrated that the elliptic relaxation concept for RANS calculations is also applicable to transonic flows with shocks; however, prediction of laminar/turbulent transition remains an important pacing item. A large fraction of the LES effort was devoted to the development and testing of a new algorithmic procedure (as opposed to phenomenological model) for subgrid scale modeling based on regularized de-filtering of the flow variables. This appears to be a very promising approach, and a significant effort is currently underway to assess its robustness in high Reynolds number flows and in conjunction with numerical methods for complex flows. As part of the Summer Program two review tutorials were given on Turbulent structures in hydrocarbon pool fires (Sheldon Tieszen), and Turbulent combustion modeling: from RANS to LES via DNS (Luc Vervisch); and two seminars entitled Assessment of turbulence models for engineering applications (Paul Durbin) and Subgrid-scale modeling for non-premixed, turbulent reacting flows (James Riley) were presented. A number of colleagues from universities, government agencies, and industry attended the final presentations of the participants on July 31 and participated in the discussions. There are twenty-six papers in this volume grouped in five areas. Each group is preceded with an overview by its coordinator.

Source record↗