Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Jet pump assisted artery

A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

Source record↗

Local phenomena, chapter 3, part C

Oceanic and coastal phenomena with dimensions ranging to 100 km are dealt with. The two major categories discussed are waves, their generation and dynamics and ocean-land related problems. The dynamics, of surface waves in both capillary and gravity ranges indicates that microwave technology provides a superior means of measuring simultaneously the spatial and temporal properties of ocean waves. The need for basic studies of physical phenomena in support of active microwave sensing is indicated. Active microwave scattering from surface waves is discussed in terms of wave dynamics.

Source record↗

Low cost silicon solar arrays

Continuous growth methodology for silicon solar cell ribbons deals with capillary effects, die effects, thermal effects and crystal shape effects. Emphasis centers on the shape of the meniscus at the ribbon edge as a factor contributing to ribbon quality with respect to defect densities. Structural and electrical characteristics of edge defined, film-fed grown silicon ribbons are elaborated. Ribbon crystal solar cells produce AMO efficiencies of 6 to 10%.

Ravi, K. V.↗

Vapor-modulated heat pipe report. Flight data analysis and further development of variable-conductance heat pipes

The design and testing of a heat pipe for spacecraft application is presented. The application in mind calls for heat loads up to 20 watts, a set-point temperature of 294K, and a sink that varies from -220K to nearly as high as the set-point. The overall heat pipe length is 137 cm. Two basically different mechanisms of achieving variable conductance in the pipe by vapor-flow throttling were studied. In one, the thermal resistance between the heat source and sink is due to a saturation-temperature drop corresponding to the vapor-pressure drop developed across the valve. In the other, the pressure difference across the valve induces capillary groove and wick dry out in an evaporation region, and thus results in an increased thermal resistance. This mechanism was selected for fabrication and testing. The pipe is a stainless-steel/methanol two-heat-pipe system. Results are presented and discussed. Engineering drawings and specifications of the pipe are shown.

Eninger, J. E.↗

Prediction of cryogenic heat pipe performance

A 304 stainless steel heat pipe with slab type capillary structure and nitrogen as the working fluid was studied in the temperature range of 60 K to 120 K. The pipe was 1.27 cm in outside diameter and 9.14 cm in total length. In the transient studies, described in detail in this report, saddles were included at evaporator and condenser ends and a radiator was included at the condenser end.

Colwell, G. T.↗

Science demonstrations

Three demonstrations of scientific concepts concerning liquids were performed during the Apollo-Soyuz Test Project mission. Chemical foaming, spreading of liquids, and capillary wicking were the subjects of each demonstration photographed in space. The results clearly illustrated the basic principles, and films suitable for educational uses are now available from the first author.

Snyder, R. S.↗

Extended analysis of Skylab experiment M558 data

A careful review of the data from Skylab M558 was made in an effort to explain the apparent anomaly of the existence of radial concentration gradients whereas none should bave been observed. The very close modelling of the experimental axial concentration profiles by the unsteady-state one-dimensional solution of Fick's Law of self-diffusion in liquid zinc, and the condition of initial uniform concentration in the radioactive pellet portion of the experimental specimens would have precluded the appearance of such radial concentration gradients. Statistical analyses were used to test the significance of the observed deviation from radial-concentration homogeneity. A student t-distribution test of significance showed that, at 90% or even at 80% level of significance, there were no significant deviations from uniformity in radial concentrations. It was also concluded that the two likely causes of any deviation that existed were the zinc to zinc-65 bonding procedure and surface phenomena such as surface tension and capillary action.

Ukanwa, A. O.↗

Flight contaminant trace analyser. Phase 1: Chromatographic input system

The purpose of this investigation was to develop two chromatographic columns which would enable a mass spectral identification of 40 specified compounds. The columns are for use in a toxic gas analyzer, which incorporates an automated gas chromatograph-mass spectrometer. Different types of stationary phases were investigated. The columns used were of the open tubular capillary type and were made of nickel. Limitations of initial and final temperature of operation led to final development of a column which could resolve most of the compounds required. The few unresolved components are capable of resolution and identification by the mass spectrometer. The columns (182m Ni x 0.8m 0.D x 0.5mm I.D) coated with Witconal La 23, yielded in excess of 200,000 theoretical plates and completed the analysis in less than 90 minutes using a carrier gas flow rate of 4 cc/min hydrogen.

Zlatkis, A.↗

Thermal Analysis of Axially Grooved Heat Pipes

The liquid viscous drag and the evaporator film coefficient were determined analytically for a heat pipe with axial rectangular grooves under zero-g conditions. The liquid pressure drop and the evaporator film coefficient for an axially grooved heat pipe were found to be expressed by the functions of the meniscus angle, which makes it possible to predict its performance analytically. The performance near its capillary pumping limit is influenced by the contact angle.

Kamotani, Y.↗

Preparation of eutectic superalloys by EFG

An attempt was made to produce airfoil shaped bars of three different eutectic superalloys by means of the edge-defined, film-fed growth (EFG) method. The alloys used were a gamma + delta Ni-Cb alloy, a gamma/gamma prime + delta Ni-Cb-Al alloy and a Co-TaC alloy containing Ni and Cr. The development of a new die material was essential in the investigation since these alloys are reactive toward known die materials. Tantalum carbide was selected as a die material because it exhibited spontaneous capillary rise and slow rate of degradation in the liquid metals. Eutectic bars up to 1 mm thick and 6 mm wide were grown from TaC dies in order to determine the growth characteristics and the thermal gradient. Large bars of the gamma/gamma prime + delta alloy were grown and tensile tested. A die with a blind central cavity was designed and several hollow, tear-shaped bars were grown.

Hurley, G. F.↗

Streaming potential measurements of biosurfaces

A technique based on the measurement of streaming potentials has been developed to evaluate the electrokinetic region of the cell periphery. This approach is feasible for cell lines propagated in in-vitro cell cultures in monolayer form. The advantage of this system is that cells may be evaluated in the living state atttached to a substrate; it is not necessary to subject the cells to enzymatic, chemical, or mechanical trauma required to obtain monodisperse suspensions which are then normally evaluated by microelectrophoresis. In this manner, it should be possible to study the influence of substrate and environmental factors on the charge density and potential at the cell periphery. The apparatus and procedure are described as well as some results concerning the electrokinetic potential of borosilicate capillaries as a function of ionic strength, pH, and temperature. The effect that turbulence and entrance flow conditions have on accurate streaming-potential measurements is discussed. The electrokinetic potential of BALB/c 3T12 fibroblasts has been quantified as a function of pH, ionic strength, glutaraldehyde fixation, and Giemsa staining.

Van Wagenen, R. A.↗

Control of electro-osmotic flow

Electro-osmotic mobility of glass capillary is sharply reduced by coating of methyl cellulose. Stable protective layer is formed after approximately ten minute exposures to methyl cellulose solution.

Patterson, W. J.↗

Apparatus for determining surface tension

System for studying capillary action uses pressure transducer and chart recorder instead of manometer. Apparatus enables measurements to be made under controlled atmospheres. It also may be remotely operated. These features are particularly useful when dealing with noxious liquids and for study of surface tension under high-pressure conditions that require use of all-metal apparatus.

Razouk, R. E.↗

Preparation and characterization of methacrylate hydrogels for zeta potential control

A technique based on the measurement of streaming potentials has been developed to evaluate the effects of hydrophilic coatings on electroosmotic flow. The apparatus and procedure are described as well as some results concerning the electrokinetic potential of glass capillaries as a function of ionic strength, pH, and temperature. The effect that turbulence and entrance flow conditions have on accurate streaming potential measurements is discussed. Various silane adhesion promoters exhibited only a slight decrease in streaming potential. A coating utilizing a glycidoxy silane base upon which methylcellulose is applied affords a six-fold decrease over uncoated tubes. Hydrophilic methacrylate gels show similar streaming potential behavior, independent of the water content of the gel. By introduction of positive or negative groups into the hydrophilic methacrylate gels, a range of streaming potential values are obtained having absolute positive or negative signs.

Gregonis, D. E.↗

Electrophoretic separator for purifying biologicals

This technique separates a single narrow zone of sample mixture in an electrolyte medium into many zones containing a single component of the mixture and electrolyte between them. Since the densities of the separated zones generally differ from that of the intervening medium, such systems are gravitationally unstable and stabilization is required. The various techniques for stabilization include using the capillary space provided by thin films, the interstices of solid material such as filter paper and a variety of gel-forming substances.

Source record↗

Behavior of fluids in a weightless environment

Fluid behavior in a low-g environment is controlled primarily by surface tension forces. Certain fluid and system characteristics determine the magnitude of these forces for both a free liquid surface and liquid in contact with a solid. These characteristics, including surface tension, wettability or contact angle, system geometry, and the relationships governing their interaction, are discussed. Various aspects of fluid behavior in a low-g environment are then presented. This includes the formation of static interface shapes, oscillation and rotation of drops, coalescence, the formation of foams, tendency for cavitation, and diffusion in liquids which were observed during the Skylab fluid mechanics science demonstrations. Liquid reorientation and capillary pumping to establish equilibrium configurations for various system geometries, observed during various free-fall (drop-tower) low-g tests, are also presented. Several passive low-g fluid storage and transfer systems are discussed. These systems use surface tension forces to control the liquid/vapor interface and provide gas-free liquid transfer and liquid-free vapor venting.

Fester, D. A.↗

An investigation of electrohydrodynamic heat pipes

The principles of electrohydrodynamic heat pip operation are first discussed. Evaporator conductance experiments are then described. A heat pipe was designed in which grooved and ungrooved evaporator surfaces could be interchanged to evaluate the necessity of capillary grooves. Optimum electrode spacing was also studied. Finally, heat convection in evaporating thin films is considered.

Loehrke, R. I.↗

Development of a jet pump-assisted arterial heat pipe

The development of a jet pump assisted arterial heat pipe is described. The concept utilizes a built-in capillary driven jet pump to remove vapor and gas from the artery and to prime it. The continuous pumping action also prevents depriming during operation of the heat pipe. The concept is applicable to fixed conductance and gas loaded variable conductance heat pipes. A theoretical model for the jet pump assisted arterial heat pipe is presented. The model was used to design a prototype for laboratory demonstration. The 1.2 m long heat pipe was designed to transport 500 watts and to prime at an adverse elevation of up to 1.3 cm. The test results were in good agreement with the theoretical predictions. The heat pipe carried as much as 540 watts and was able to prime up to 1.9 cm. Introduction of a considerable amount of noncondensible gas had no adverse effect on the priming capability.

Bienert, W. B.↗