Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

MO-A-18C-01: Proton Therapy I: Basics of Proton Therapy

The goal of this session is to introduce the audience to the physics, dosimetry and treatment planning procedures used in proton therapy. The course material covers the basic physics of proton interaction with matter and physical characteristics of clinical proton beams. It will provide information on proton delivery systems and beam delivery techniques for scattered and scanning proton beams. It will include the requirements for dosimetry measurements and present the equipment needed for commissioning of proton beams for clinical use and quality assurance checks as well as methods used for proton beam calibration and dose verification of patient treatment fields. The session covers the treatment planning strategies for various anatomical sites, methods to address uncertainties in proton therapy and uncertainty mitigation to generate robust treatment plans. Challenges involved in the motion management in proton therapy will also be discussed. Learning Objectives: Gain knowledge on physics, dosimetry, treatment planning and quality assurance for proton therapy. Understand the uncertainties associated with proton therapy and currently used strategies for their mitigation in treatment planning.

07 ISOTOPE AND RADIATION SOURCES↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distance Determination by Gated Viewing Systems Taking into Account the Illuminating Pulse Shape

For gated viewing systems with triangular and trapezoidal illuminating pulses, we have obtained the range-intensity profiles (RIPs) of the signal as the time delay was varied between the leading edges of the gate pulse and the illuminating pulse. We have established that if the duration of the illuminating pulse Δt{sub las} is less than or equal to the duration of the gate pulse Δt{sub IC}, then the expressions for the characteristic distances are the same as for rectangular pulses and they can be used to determine the distance to objects. When Δt{sub las} > Δt{sub IC}, in the case of triangular illuminating pulses the RIP is bell-shaped. For trapezoidal pulses, the RIP is bell-shaped with or without a plateau section. We propose an empirical method for determining the characteristic distances to the RIP maximum and the boundary points for the plateau section, which we then use to calculate the distance to the object. Using calibration constants, we propose a method for determining the distance to an object and we have experimentally confirmed the feasibility of this method.

42 ENGINEERING↗

Robust and scalable uncertainty estimation with conformal prediction for machine-learned interatomic potentials

Abstract Uncertainty quantification (UQ) is important to machine learning (ML) force fields to assess the level of confidence during prediction, as ML models are not inherently physical and can therefore yield catastrophically incorrect predictions. Established a-posteriori UQ methods, including ensemble methods, the dropout method, the delta method, and various heuristic distance metrics, have limitations such as being computationally challenging for large models due to model re-training. In addition, the uncertainty estimates are often not rigorously calibrated. In this work, we propose combining the distribution-free UQ method, known as conformal prediction (CP), with the distances in the neural network’s latent space to estimate the uncertainty of energies predicted by neural network force fields. We evaluate this method (CP+latent) along with other UQ methods on two essential aspects, calibration, and sharpness, and find this method to be both calibrated and sharp under the assumption of independent and identically-distributed (i.i.d.) data. We show that the method is relatively insensitive to hyperparameters selected, and test the limitations of the method when the i.i.d. assumption is violated. Finally, we demonstrate that this method can be readily applied to trained neural network force fields with traditional and graph neural network architectures to obtain estimates of uncertainty with low computational costs on a training dataset of 1 million images to showcase its scalability and portability. Incorporating the CP method with latent distances offers a calibrated, sharp and efficient strategy to estimate the uncertainty of neural network force fields. In addition, the CP approach can also function as a promising strategy for calibrating uncertainty estimated by other approaches.

74 ATOMIC AND MOLECULAR PHYSICS↗

Uncertainty due to non-linearity in radiation thermometers calibrated by multiple fixed points

A new method to estimate the uncertainty due to non-linearity is described on the n= 3 scheme basis. The expression of uncertainty is mathematically derived applying the random walk method. The expression is simple and requires only the temperatures of the fixed points and a relative uncertainty value for each flux-doubling derived from the non-linearity measurement. We also present an example of the method, in which the uncertainty of temperature measurement by a radiation thermometer is calculated on the basis of non-linearity measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photogrammetry Applied to Wind Tunnel Testing

In image-based measurements, quantitative image data must be mapped to three-dimensional object space. Analytical photogrammetric methods, which may be used to accomplish this task, are discussed from the viewpoint of experimental fluid dynamicists. The Direct Linear Transformation (DLT) for camera calibration, used in pressure sensitive paint, is summarized. An optimization method for camera calibration is developed that can be used to determine the camera calibration parameters, including those describing lens distortion, from a single image. Combined with the DLT method, this method allows a rapid and comprehensive in-situ camera calibration and therefore is particularly useful for quantitative flow visualization and other measurements such as model attitude and deformation in production wind tunnels. The paper also includes a brief description of typical photogrammetric applications to temperature- and pressure-sensitive paint measurements and model deformation measurements in wind tunnels.

Liu, Tian-Shu↗

Real-time dynamic calibration of a tunable frequency laser source using a Fabry-Pérot interferometer

We report on a method for real-time dynamic calibration of a tunable external cavity diode laser by using a partially mode-matched plano-concave Fabry-Pérot interferometer in reflection geometry. Wide range laser frequency scanning is carried out by piezo-driven tilting of a diffractive grating playing the role of a frequency selective mirror in the laser cavity. The grating tilting system has a considerable mechanical inertness, so static laser frequency calibration leads to false results. The proposed real-time dynamic calibration based on the identification of primary- and Gouy-effect type secondary interference peaks with known frequency and temporal history can be used for a wide scanning range (from 0.2 GHz to more than 1 GHz). A concave spherical mirror with a radius of R = 100 cm and a plain 1% transmitting mirror was used as a Fabry-Pérot interferometer with various resonator lengths to investigate and demonstrate real-time calibration procedures for two kinds of laser frequency scanning functions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-flight calibration of the high-gain antenna pointing for the Mariner Venus-Mercury 1973 spacecraft

The methods used to in-flight calibrate the pointing direction of the Mariner Venus-Mercury 1973 spacecraft high gain antenna and the achieved antenna pointing accuracy are described. The overall pointing calibration was accomplished by performing calibration sequences at a number of points along the spacecraft trajectory. Each of these consisted of articulating the antenna about the expected spacecraft-earth vector to determine systematic pointing errors. The high gain antenna pointing system, the error model used in the calibration, and the calibration and pointing strategy and results are discussed.

Hardman, J. M.↗

Calibration of a Structural Finite Element Model for a Representative Inflatable Space Structure Utilizing Probabilistic Methods and Surrogate Models

A structural finite element model representing a novel inflatable airlock concept has been calibrated using full‐scale test data. The concept, denoted as the Non‐Axisymmetric Inflatable Pressure Structure (NAIPS), was developed under NASA’s Minimalistic Advanced Softgoods Hatch (MASH) Program. The current studies extended previous numerical efforts by incorporating the midbody section of the NAIPS to the dome section and calibrating the model with test data using a process that included surrogate models. Brief overviews of the finite element model and calibration process are provided. The completion of the calibration process provided a model that adequately replicated the test data. The successful demonstration of calibration of a finite element model representing an inflatable habitat provides confidence in the ability to use numerical simulations and associated surrogate models to support design and certification of inflatable space habitats.

Lyle, Karen H.↗

Machine learning based approach to predict ductile damage model parameters for polycrystalline metals

Damage models for ductile materials typically need to be parameterized, often with the appropriate parameters changing for a given material depending on the loading conditions. This can make parameterizing these models computationally expensive, since an inverse problem must be solved for each loading condition. Using standard inverse modeling techniques typically requires hundreds or thousands of high-fidelity computer simulations to estimate the optimal parameters. Additionally, the time of a human expert is required to set up the inverse model. Machine learning has recently emerged as an alternative approach to inverse modeling in these settings, where the machine learning model is trained in an offline manner and new parameters can be quickly generated on the fly, after training is complete. Here, this work utilizes such a workflow to enable the rapid parameterization of a ductile damage model called TEPLA with a machine learning inverse model. The machine learning model can efficiently estimate the model parameters much faster, as compared to previously employed methods, such as Bayesian calibration. The results demonstrate good accuracy on a synthetic test dataset and is validated against experimental data.

36 MATERIALS SCIENCE↗

Workflow-based automatic processing for Internet of Floating Things crowdsourced data

Data from sensors incorporated into mobile devices, such as networked navigational sensors, can be used to capture detailed environmental information. We describe here a workflow and framework for using sensors on boats to construct unique new datasets of underwater topography (bathymetry). Starting with a large number of measurements of position, depth, etc., obtained from such an Internet of Floating Things, we illustrate how, with a specialized protocol, data can be communicated to cloud resources, even when using delayed, intermittent, or disconnected networks. We then propose a method for automatic sensor calibration based on a novel reputation approach. Sampled depth data are interpolated efficiently on a cloud computing platform in order to provide a continuously updated bathymetric database. Our prototype implementation uses the FACE-IT Galaxy workflow engine to manage network communication and exploits the computational power of GPGPUs in a virtualized cloud environment, working with a CUDA-parallel algorithm, for efficient data processing. We report on an initial evaluation involving data from a sailing vessel in Italian coastal waters.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Radiation Dose and Image Quality for the Varian Cone Beam Computed Tomography System

Purpose: To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as 'new' and 'old' protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. Methods and Materials: A calibrated Farmer chamber and two standard cylindrical Perspex CT dosimetry phantoms with diameter of 16 cm (head phantom) and 32 cm (body phantom) were used to measure the weighted cone-beam computed tomography dose index (CBCTDIw) of the Varian CBCT system. The absorbed dose of different organs was measured in a female anthropomorphic phantom with thermoluminescent dosimeters (TLD) and the total effective dose was estimated according to International Commission on Radiological Protection (ICRP) Publication 103. The dose measurement and image quality were studied for head-and-neck and pelvic regions, and comparison was made between the new and old protocols. Results: The values of the new CBCTDIw head-and-neck and pelvic protocols were 36.6 and 29.4 mGy, respectively. The total effective doses from the new head-and-neck and pelvic protocols were 1.7 and 8.2 mSv, respectively. The absorbed doses of lens for the new 200{sup o} and old 360{sup o} head-and-neck protocols were 3.8 and 59.4 mGy, respectively. The additional secondary cancer risk from daily CBCT might be up to 2.8%. Conclusions: The new Varian CBCT provided volumetric information for image guidance with acceptable image quality and lower radiation dose. This imaging tool gave a better standard for patient daily setup verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-scale integration of satellite remote sensing improves characterization of dry-season green-up in an Amazon tropical evergreen forest

In tropical forests, leaf phenology-particularly the pronounced dry-season green-up-strongly regulates biogeochemical cycles of carbon and water fluxes. However, uncertainties remain in the understanding of tropical forest leaf phenology at different spatial scales. Phenocams accurately characterize leaf phenology at the crown and ecosystem scales but are limited to a few sites and time spans of a few years. Time-series satellite observations might fill this gap, but the commonly used satellites (e.g. MODIS, Landsat and Sentinel-2) have resolutions too coarse to characterize single crowns. To resolve this observational challenge, we used the PlanetScope constellation with a 3m resolution and near daily nadir-view coverage. We first developed a rigorous method to cross-calibrate PlanetScope surface reflectance using daily BRDF-adjusted MODIS as the reference. We then used linear spectral unmixing of calibrated PlanetScope to obtain dry-season change in the fractional cover of green vegetation (GV) and non-photosynthetic vegetation (NPV) at the PlanetScope pixel level. We used the Central Amazon Tapajos National Forest k67 site, as all necessary data (from field to phenocam and satellite observations) was available. For this proof of concept, we chose a set of 22 dates of PlanetScope measurements in 2018 and 16 in 2019, all from the six drier months of the year to provide the highest possible cloud-free temporal resolution. Our results show that MODIS-calibrated dry-season PlanetScope data (1) accurately assessed seasonal changes in ecosystem-scale and crown-scale spectral reflectance; (2) detected an increase in ecosystem-scale GV fraction (and a decrease in NPV fraction) from June to November of both years, consistent with local phenocam observations with R 2 around 0.8; and (3) monitored large seasonal trend variability in crown-scale NPV fraction. Finally, our results highlight the potential of integrating multi-scale satellite observations to extend fine-scale leaf phenology monitoring beyond the spatial limits of phenocams.

54 ENVIRONMENTAL SCIENCES↗

Optimization of {sup 1}H and {sup 13}C NMR methods for structural characterization of acetone and pyridine soluble/insoluble fractions of a coal tar pitch

{sup 1}H and {sup 13}C high-resolution liquid-state NMR methods were used for the quantitative characterization of different molecular weight fractions of a coal tar pitch (CTP). Three fractions were studied: pitch acetone solubles (PAS), pitch pyridine soluble-acetone insolubles (PPS), and pitch pyridine insolubles (PPI). Standard liquid-state NMR methods were modified and calibrated for use with undeuterated quinoline or undeuterated 1-methyl-2-pyrrolidinone (NMP) as the solvent. This made it possible to calculate the average structural parameters for the higher molecular weight (MW) fractions of the coal tar pitch. Quantitative comparisons of structural differences between the solubility-separated fractions of the pitch are reported. The aromaticity and the average number of aromatic rings per polynuclear aromatic structure were both found to decrease with increasing solubility. Similarly, pericondensed and all other quaternary carbon species were found to decrease with increasing solubility. This suggests that 'continental' type structures become more dominant as the solvent solubility of these coal derived fractions diminishes. The estimated average number of aromatic rings ranged from 1 to 2 rings in the PAS fraction, 4 to 21 rings in the PPS fraction, and 11 to 210 rings in the PPI fraction. These ring-numbers were directly related to the number average molecular mass (M{sub n}) assigned to the particular fraction in the average structural parameter (ASP) calculations. The lower-limit of the M{sub n} values was derived from the ASP calculations as 200, 450, and 6200 u for the PAS, PPS, and PPI fractions, respectively. 66 refs., 7 figs., 15 tabs.

01 COAL, LIGNITE, AND PEAT↗

Small-angle X-ray and neutron scattering

Small-angle scattering (SAS) is a technique that is able to probe the structural organization of matter and quantify its response to changes in external conditions. X-ray and neutron scattering profiles measured from bulk materials or materials deposited at surfaces arise from nanostructural inhomogeneities of electron or nuclear density. Furthermore, the analysis of SAS data from coherent scattering events provides information about the length scale distributions of material components. Samples for SAS studies may be prepared in situ or under near-native conditions and the measurements performed at various temperatures, pressures, flows, shears or stresses, and in a time-resolved fashion. In this Primer, we provide an overview of SAS, summarizing the types of instrument used, approaches for data collection and calibration, available data analysis methods, structural information that can be obtained using the method, and data depositories, standards and formats. Recent applications of SAS in structural biology and the soft-matter and hard-matter sciences are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Challenges for the determination of piezoelectric constants with piezoresponse force microscopy

At first sight, piezoresponse force microscopy (PFM) seems an ideal technique for the determination of piezoelectric coefficients, thus making use of its ultrahigh vertical resolution (<0.1 pm/V). In general, however, only qualitative PFM imaging is performed and in the few publications containing quantitative data, the obtained values vary considerably with respect to macroscopic measurements. In this contribution, we present a reliable calibration procedure for PFM followed by a careful analysis of the encounted difficulties using PFM for determining piezoelectric coefficients. We point out different approaches for their solution and expose why those difficulties cannot be circumvented without an extensive effort.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass- and energy-analyses of ions from plasma by means of a miniature Thomson spectrometer

The paper presents an improved version of a miniature mass-spectrometer of the Thomson-type, which has been adopted for ion analysis near the dense plasma region inside a vacuum chamber. Problems connected with the separation of ions from plasma streams are considered. Input diaphragms and pumping systems, needed to ensure good vacuum inside the analyzing region, are described. The application of the miniature Thomson-type analyzer is illustrated by ion parabolas recorded in plasma-focus facility and rod plasma injector experiment. A quantitative analysis of the recorded ion parabolas is presented. Factors influencing accuracy of the ion analysis are discussed and methods of the spectrometer calibration are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗