Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

A Novel Design of Guiding Stress Wave Propagation

Impact loads can induce a series of undesirable physical phenomena including vibration, acoustical shock, perforation, fracture and fragmentation, etc. The energy associated with the impact loads can lead to severe structure damage and human injuries. A design approach which effectively reduces these negative impacts through shock/stress wave diversion is highly needed. In this paper, a computational model which predicts stress wave propagation by considering different beam geometries and configurations is developed. Additionally, a novel concept of wave guide design which modifies the stress wave propagation path without disturbance is also presented. Furthermore, this design approach is not only useful for material property characterization particularly at intermediate or high strain rates, but also allows stress wave propagation in a desired direction as the shock/impact energy can be redistributed in controllable paths. The numerical results are experimentally verified through a Drop-Hopkinson bar apparatus at Sandia National Laboratories.

36 MATERIALS SCIENCE↗

Results of the 2005-2008 Association of Residents in Radiation Oncology Survey of Chief Residents in the United States: Clinical Training and Resident Working Conditions

Purpose: To document clinical training and resident working conditions reported by chief residents during their residency. Methods and Materials: During the academic years 2005 to 2006, 2006 to 2007, and 2007 to 2008, the Association of Residents in Radiation Oncology conducted a nationwide survey of all radiation oncology chief residents in the United States. Chi-square statistics were used to assess changes in clinical training and resident working conditions over time. Results: Surveys were completed by representatives from 55 programs (response rate, 71.4%) in 2005 to 2006, 60 programs (75.9%) in 2006 to 2007, and 74 programs (93.7%) in 2007 to 2008. Nearly all chief residents reported receiving adequate clinical experience in commonly treated disease sites, such as breast and genitourinary malignancies; and commonly performed procedures, such as three-dimensional conformal radiotherapy and intensity-modulated radiotherapy. Clinical experience in extracranial stereotactic radiotherapy increased over time (p < 0.001), whereas clinical experience in endovascular brachytherapy (p <0.001) decreased over time. The distribution of gynecologic and prostate brachytherapy cases remained stable, while clinical case load in breast brachytherapy increased (p = 0.006). A small but significant percentage of residents reported receiving inadequate clinical experience in pediatrics, seeing 10 or fewer pediatric cases during the course of residency. Procedures involving higher capital costs, such as particle beam therapy and intraoperative radiotherapy, and infrequent clinical use, such as head and neck brachytherapy, were limited to a minority of institutions. Most residency programs associated with at least one satellite facility have incorporated resident rotations into their clinical training, and the majority of residents at these programs find them valuable experiences. The majority of residents reported working 60 or fewer hours per week on required clinical duties. Conclusions: Trends in clinical training and resident working conditions over 3 years are documented to allow residents and program directors to assess their residency training.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Twelve-Month Prostate-Specific Antigen Values and Perineural Invasion as Strong Independent Prognostic Variables of Long-Term Biochemical Outcome After Prostate Seed Brachytherapy

Purpose: To determine whether post-treatment prostate-specific antigen (ptPSA) values at 12 months and other clinical parameters predict long-term PSA relapse-free survival (PRFS) following prostate seed brachytherapy. Methods and Materials: Records of 204 hormone-naieve patients with localized adenocarcinoma of the prostate treated at St. Mary's Regional Medical Center in Reno, NV, and at Carson Tahoe Regional Medical Center in Carson City, NV, between 1998 and 2003, using I-125 or Pd-103 seed brachytherapy, were retrospectively analyzed. Treatment planning was done using a preplanned, modified peripheral loading technique. A total of 185 of 204 patients had PSA records at 12 months after implant. Variables included were age, initial pretreatment PSA, Gleason score, T stage, National Comprehensive Cancer Network (NCCN) risk group (RG), perineural invasion (PNI), external beam boost, dose, and ptPSA levels at 12 months with cutpoints at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml. Results: Median follow-up was 80 months, and median age was 69 years. The numbers of patients stratified by NCCN low, intermediate, and high RG were 110:65:10, respectively. Monotherapy and boost prescription doses were 145 Gy and 110 Gy for I-125, and 125 Gy and 100 Gy for Pd-103 seeds, respectively. The median dose (D90) was 95.4% of the prescribed dose. The 5-year PRFS at the 12-months ptPSA levels of {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml were 98.5%, 85.7%, 61.5%, and 22.2%, respectively. The 10-year PRFS at the 12-months ptPSA levels of {<=}1 and 1.01 to 2.00 ng/ml were 90.5% and 85.7%, respectively. In multivariate analysis, both ptPSA and PNI were significant independent predictors of PRFS. Hazard ratios (HR) for ptPSA levels at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml at 12 months were 1, 4.96, 27.57, and 65.10, respectively. PNI had an HR of 6.1 (p = 0.009). Conclusions: Presence of PNI and ptPSA values at 12 months are strong prognostic variables for long-term PRFS after definitive prostate brachytherapy seed implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication and testing of the transition section between modules of a wakefield accelerator

The fabrication process is presented for a typical transition section located between each cylindrical corrugated waveguide structure comprising the wakefield accelerator module. The transition section includes couplers for extracting the 180 GHz TM 01 accelerating mode and separate couplers for extracting the 190 GHz HE 11 dipole mode, both modes induced by the electron bunch traversing the cylindrical corrugated waveguide structure. Extraction of the high-power accelerating mode reduces the heat load due to the subterahertz wave power dissipation within the corrugated accelerating structure. Extraction of the low-power dipole mode serves the purpose of detecting the electron bunch transverse oscillations within the wakefield accelerator and identifying the onset of beam breakup instability. Comprehensive testing of the fully functional transition section with an electron beam was done at the Accelerator Test Facility in Brookhaven National Laboratory which verified the functionality of the transition section. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

SU-E-T-09: A Clinical Implementation and Optimized Dosimetry Study of Freiberg Flap Skin Surface Treatment in High Dose Rate Brachytherapy

Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists of multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.

60 APPLIED LIFE SCIENCES↗

The Simons Observatory: modeling optical systematics in the Large Aperture Telescope

We present geometrical and physical optics simulation results for the Simons Observatory Large Aperture Telescope. This work was developed as part of the general design process for the telescope, allowing us to evaluate the impact of various design choices on performance metrics and potential systematic effects. The primary goal of the simulations was to evaluate the final design of the reflectors and the cold optics that are now being built. We describe nonsequential ray tracing used to inform the design of the cold optics, including absorbers internal to each optics tube. We discuss ray tracing simulations of the telescope structure that allow us to determine geometries that minimize detector loading and mitigate spurious near-field effects that have not been resolved by the internal baffling. We also describe physical optics simulations, performed over a range of frequencies and field locations, that produce estimates of monochromatic far-field beam patterns, which in turn are used to gauge general optical performance. Finally, we describe simulations that shed light on beam sidelobes from panel gap diffraction.

Gudmundsson, Jon E. (ORCID:0000000317600355)↗

Evaluation of Fatigue Damage Accumulation Functions for Delamination Initiation and Propagation

The present report follows on the cohesive fatigue damage model methodology proposed in NASA-TP-2018-219838. In that report, an empirical function describing the incremental damage due to cyclic loading was used to calculate fatigue damage within a cohesive formulation. The form of the function was developed such that, when integrated at a constant stress amplitude from no damage to failure, it produces a life versus load response that is consistent with an S-N diagram. Therefore, the parameters of the damage model could be obtained by fitting the model predictions to an S-N diagram. The finite element analyses performed demonstrate that the cohesive fatigue accumulation function provides a link between the S-N diagram that describes crack initiation, and the Paris law that characterizes the rate of crack propagation. However, when the model was proposed, it was not known whether the form of the damage accumulation function associated with a desired S-N diagram is unique and, if not, if the link between S-N and the Paris law is unique and independent of the fatigue function selected. In the effort described herein, several alternative forms of the damage function that reproduce the desired features of S-N diagrams were found and evaluated. The effects of each of these functions on the predicted parameters of the Paris law and the propagation threshold are discussed. The results indicate that the predicted exponent m of the Paris law is indeed independent of the damage accumulation function. However, different functions predict different values for the pre-factor C of the Paris law. Therefore, the proper damage accumulation function must be selected by comparison with experiments. One of the new damage accumulation functions proposed herein was found to be particularly useful for analysis because of the ease with which the model parameters can be determined with a minimal amount of experimental information. The effectiveness of the proposed methodology and damage function was demonstrated by conducting analyses of a double cantilever beam test, a mixed-mode bending test, and a three-point bending test of a skin/doubler specimen. The results indicate that the same set of model parameters can provide accurate predictions of the rate of fatigue crack propagation for a variety of material interfaces, mode mixities, load levels, and stress ratios.

Cohesive elements↗

Characteristics of a symmetrical Cockcroft-Walton power supply of 50 Hz 1.2 MV/50 mA

A 1.2 MV/50 mA symmetrical Cockcroft-Walton (SCW) power supply of over 83% power efficiency, driven by 50 Hz frequency, was developed for an industrial electron beam irradiator. It is constructed by capacitors of 45 nF and 28.13 nF in the coupling column and capacitors of 18.75 nF in the smoothing column. Working status of the rectifier in high power output condition was analyzed, and the conduction angle of the rectifier was calculated. The power factor (PF) of the SCW circuit has been studied, and the equivalent condensance of the circuit has been derived. Measurements were done for the PF compensation. The surge impact during the short circuit transient process was considered in choosing the protection resistance. Test results showed that design specifications of the power supply were achieved, with the non-load voltage being up to 1.32 MV and the ratio of ripple voltage to output voltage as 9.4%.

43 PARTICLE ACCELERATORS↗

Variationally consistent Maxwell stress in flexoelectric structures under finite deformation and immersed in free space

Maxwell stress refers to the mechanical stress exerted on a dielectric material due to the presence of electric fields. It plays a significant role in the interaction between a dielectric material and the surrounding free space under finite deformation. Previous research on finite deformation of flexoelectricity mainly adopted a modified form of Maxwell stress, potentially not able to correctly capture some physical phenomena, such as the compression of a dielectric droplet in an electric field. In this work, we propose a consistent and complete variational principle for flexoelectricity, in which the Maxwell stress emerges naturally from the derivation, without introducing additional assumptions. An Isogeometric analysis-based numerical framework is developed accordingly and verified by both linear and nonlinear benchmark cases compared with experimental results. The present framework successfully captures and quantifies the behaviors of conductive liquids and soft dielectric solids subjected to an external electric field. Finally, a novel scenario is investigated in which a flexoelectric beam immersed in free space is analyzed, showing the interesting distribution of Maxwell stress-induced tractions at opposing boundaries. The test demonstrates that a higher dielectric constant can effectively enhance the material's stiffness in response to the external electric loading.

36 MATERIALS SCIENCE↗

A study of sacrificial mirrors for use prior to a laser wakefield accelerator driven by the Z-Petawatt laser

Many experiments at Sandia’s Z Pulsed Power Facility require x-ray backlighting diagnostics to understand experiment performance. Due to limitations in present-day source/detection modalities, most x-ray diagnostics at Z are restricted to photon energies <20 keV, ultimately limiting the density, amount, and atomic number of targets diagnosable in experiments. These limitations force the use of low-Z materials like Beryllium, and they prevent acquisition of important backlighting data for materials/densities that are opaque to soft x-rays and where background emission from the Z load and transmission lines overwhelm diagnostics. In this LDRD project, we have investigated the design and development of a laser wakefield acceleration platform driven by the Z-Petawatt laser – a platform that would enable the generation of a pulsed, collimated beam of high energy x-rays up to 100 keV. Geometrical considerations for implementation on the Z Machine require the use of sacrificial mirrors, which have been tested in offline experiments in the Chama target chamber in building 983. Our results suggest the use of sacrificial mirrors would not necessarily inhibit the laser wakefield x-ray process, particularly with the benefits stemming from planned laser upgrades. These conclusions support the continuation of laser wakefield source research and the development of the necessary infrastructure to deliver the Z-Petawatt laser to the Z center section along the appropriate lines of sight. Ultimately, this new capability will provide unprecedented views through dense states of matter, enabling the use of previously incompatible target materials/designs, and uncovering a new set of observables accessible through diffraction and spectroscopy in the hard x-ray regime. These will amplify the data return on precious Z shots and enhance Sandia’s ability to investigate fundamental physics in support of national security.

43 PARTICLE ACCELERATORS↗

Fracture of composite-adhesive-composite systems

This program was undertaken to initiate the development of a test method for testing adhesive joints in metal-adhesive-composite systems. The uniform double cantilever beam (UDCB) and the width tapered beam (WTB) specimen geometries were evaluated for measuring Mode I fracture toughness in these systems. The WTB specimen is the preferred geometry in spite of the fact that it is more costly to machine than the UDCB specimen. The use of loading tabs attached to thin sheets of composites proved to be experimentally unsatisfactory. Consequently, a new system was developed to load thin sheets of adherends. This system allows for the direct measurement of displacement along the load line. In well made joints separation occurred between the plies rather than in the adhesive.

Ripling, E. J.↗

Manipulator For A Vacuum Chamber

Rotary seal provides for external actuators. Positioner in vacuum employs four actuators; up/down, horizontal rotary, horizontal, and vertical rotary. External up/down and azimuthal actuators drives shaft entering vacuum chamber through sliding and rotating seal. Placement of actuator motors outside vacuum chamber reduces heat-removal load on system. Atop 2.5-cm-diameter shaft is stage supporting masses as great as 15 kg. Small motors on stage provide horizontal translation and rotation in vertical plane. Manipulator developed for calibrating plasma detectors by subjecting them to particle beams in vacuum. Standard, commercially available parts used.

Hunsaker, F.↗

Mass-additive modal test method for verification of constrained structural models

A method for deriving constrained or fixed-base modes and frequencies from free-free modes of a structure with mass-loaded boundaries is developed. Problems associated with design and development of test fixtures can be avoided with such an approach. The analytical methodology presented is used to assess applicability of the mass-additive method for three types of structures and to determine the accuracy of derived constrained modes and frequencies. Results show that mass loading of the boundaries enables local interface modes to be measured within a desired frequency bandwidth, thus allowing constrained modes to be derived with considerably fewer free-free modes than for unloaded boundaries. Good convergence was obtained for a simple beam and a truss-like Shuttle payload, both of which had well-spaced modes and stiff interface support structures. Slow convergence was obtained for a space station module prototype, a shell-like structure having high modal density.

Admire, John R.↗

Propulsion System Testing for the Iodine Satellite (iSAT) Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (less than 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. An iodine-based system is not without its challenges. The primary challenge is that the entire feed system must be maintained at an elevated temperature to prevent the iodine from depositing (transitioning from the gas phase directly back into the solid phase), which will block the propellant feed lines. Furthermore, deposition will occur unless the temperature in the lines is not greater than the temperature of the propellant reservoir. The flow rate can be controlled by adjusting the heating applied to the reservoir, but as with any thermal control there is a relatively slow response to changes in the heating rate. In the present paper, we describe the propulsion and propellant feed system for the iodine satellite (iSAT) flight demonstration mission. The system is based around the Busek BHT-200 Hall thruster, which has been modified for chemical compatibility with iodine vapor. While the gross propellant flow rate is maintained by the heated propellant reservoir, the flow to the anode and cathode are adjusted using two heated Vacco proportional flow control valves (PFCV), which provide very fast response on the flow rate adjustment. The flight mission design layout will be presented, showing how the system will be packaged into the overall 12-U spacecraft and the techniques being employed to protect the remaining spacecraft hardware from the propulsion system (e.g., plasma impingement, iodine deposition, thermal loads). In addition to the flight system design, results of testing the thruster and cathode with both operating on iodine propellant are presented. The tests are conducted on a thrust stand (see Fig. 1) in a large vacuum chamber containing a beam dump chilled to below -100 C to 'cryopump' the propellant. The thruster performance during these tests is presented, with these data used to evaluate the feed system and guide further refinements. Results of relatively long duration testing are presented to demonstrate the capability to operate for the length of the iSAT mission and to perform a number of re-starts as will be required by the mission concept of operations.

Polzin, Kurt A.↗

Gas well deliquification. 2nd. ed.

Chapter 1: Introduction; Chapter 2: Recognizing Symptoms of Liquid Loading in Gas Wells; Chapter 3: Critical Velocity; Chapter 4: Systems Nodal Analysis; Chapter 5: Sizing Tubing; Chapter 6: Compression; Chapter 7: Plunger Lift; Chapter 8: Use of Foam to Deliquefy Gas Wells; Chapter 9: Hydraulic Pumping; Chapter 10: Use of Beam Pumps to Deliquefy Gas Wells; Chapter 11: Gas Lift; Chapter 12: Electric Submersible Pumps; Chapter 13: Progressing Cavity Pumps; Chapter 14: Coal Bed Methane; Chapter 15: Production Automation. Chapter 14, by David Simpson, based in the San Juan Basin, addresses issues in coal bed methane, low pressure operations, gas compression, gas measurement, oil field construction, gas well deliquification and project management.

01 COAL, LIGNITE, AND PEAT↗

Development of an Extreme Environment Materials Research Facility at Princeton

The need for a fundamental understanding of material response to a neutron and/or high heat flux environment can yield development of improved materials and operations with existing materials. Such understanding has numerous applications in fields such as nuclear power (for the current fleet and future fission and fusion reactors), aerospace, and other research fields (e.g., high-intensity proton accelerator facilities for high energy physics research). A proposal has been advanced to develop a facility for testing various materials under extreme heat and neutron exposure conditions at Princeton. The Extreme Environment Materials Research Facility comprises an environmentally controlled chamber (48 m^3) capable of high vacuum conditions, with extreme flux beams and probe beams accessing a central, large volume target. The facility will have the capability to expose large surface areas (1 m^2) to 14 MeV neutrons at a fluence in excess of 10^13 n/s. Depending on the operating mode. Additionally beam line power on the order of 15-75 MW/m2 for durations of 1-15 seconds are planned... The multi-second duration of exposure can be repeated every 2-10 minutes for periods of 10-12 hours. The facility will be housed in the test cell that held the Tokamak Fusion Test Reactor (TFTR), which has the desired radiation and safety controls as well as the necessary loading and assembly infrastructure. The facility will allow testing of various materials to their physical limit of thermal endurance and allow for exploring the interplay between radiation-induced embrittlement, swelling and deformation of materials, and the fatigue and fracturing that occur in response to thermal shocks. The combination of high neutron energies and intense fluences will enable accelerated time scale studies. The results will make contributions for refining predictive failure modes (modeling) in extreme environments, as well as providing a technical platform for the development of new alloys, new materials, and the investigation of repair mechanisms. Effects on materials will be analyzed with in situ beam probes and instrumentation as the target is exposed to radiation, thermal fluxes and other stresses. Photon and monochromatic neutron fluxes, produced using a variable-energy (4-45 MeV) electron linac and the highly asymmetric electron-positron collisions technique used in high-energy physics research, can provide non-destructive, deep-penetrating structural analysis of materials while they are undergoing testing. The same beam lines will also be able to generate neutrons from photonuclear interactions using existing Bremsstrahlung and positrons on target quasi-monochromatic gamma rays. Other diagnostics will include infrared cameras, residual gas analyzer (RGA), and thermocouples; additional diagnostic capability will be added.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pathways to IEC Standards for Heliostat Design Qualification and Site Acceptance in Central Receiver CSP Applications

This paper surveys the existing landscape of standards relevant to heliostats, identifies their gaps, and proposes a path forward to a comprehensive set of heliostat guidelines, technical specifications, and standards under the framework of International Electrotechnical Commission (IEC) TC 117. Gaps in existing guidelines and standards are surveyed using a three-tiered taxonomy: component-level, heliostat-level, and field-level. At each level, the gap analysis is followed by a proposal for a coordinated path forward on the development of standards. At the component level, advances in the understanding of wind loading should inform a technical specification for drives and structures. Reflectors require consolidation of measurement guidelines into existing standards documents. Communications & controls require technical standards to inform their selection and secure implementation. At the heliostat level, IEC 62817 (solar trackers) adequately characterizes drive systems, structures, and electronics, but requires adaptation to heliostats' use patterns, operating modes, and expected life cycles. IEC 62817 does not address heliostat beam quality and pointing accuracy, but the process for determining both is elaborated in the SolarPACES Guideline for Heliostat Performance Testing. This SolarPACES document requires two main modifications: adaptation to IEC language and inclusion of testing after heliostats which have undergone accelerated weathering and mechanical cycling (to understand performance degradation). At the field level, IEC 62862-4-2 addresses the function and control of heliostat fields but does not cover the statistically rigorous testing of heliostat groups, or field performance factors like security and soiling. The addition of documents under IEC-62862-4 is proposed to address this gap.

beam↗

Generation of EM radiations using intense electron beam produced in vacuum

The results of a pulse power generator driving an axial virtual cathode oscillator are being presented in this paper as a source of high power microwave (HPM) radiations. The electron beam generator is also modified to attain the intense X-ray burst. The pulse power generator used for these applications is common and is having 10 ohms as its characteristic impedance with 50nS of pulse width. The peak charging voltage of the pulse forming line is 450 kV and hence 225 kV and 22.5 kA is peak voltage and peak current delivery capabilities respectively for the pulse power generator. The peak electrical power of the generator is 5GW for a matched load. The charging power supply for the pulse forming line consists of a high voltage generator made by pulse transformer and charging the pulse forming line in the first cycle of the charging pulse. To utilize the energy of the primary capacitive storage efficiently the pulse transformer is having 0.8 coupling coefficient between its primary and the secondary. The axial vircator chamber is evacuated to attain the vacuum of 2 x 10{sup -4} torr for the HPM application. In the case of modified electron beam chamber for the generation of X-rays the vacuum of same order is used. The pulse forming line is made using equal lengths of high voltage transmission lines, each having a length of 10 meters, connected in the parallel to give a net source impedance of 10 ohm. The pulse power generator can operate in repetitive mode and hence the HPM as well as X-rays may be generated in the repetitive burst. (author)

43 PARTICLE ACCELERATORS↗