Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “baseline estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Drug-Eluting Nitinol Stent Treatment of the Superficial Femoral Artery and Above-the-Knee Popliteal Artery (The Zilver PTX Single-Arm Clinical Study): A Comparison Between Diabetic and Nondiabetic Patients

Purpose: To describe the 1-year results of drug-eluting nitinol stent placement in the femoropopliteal artery of diabetic and nondiabetic patients. Materials and Methods: All patients enrolled in this prospective, multicenter study underwent paclitaxel-eluting stent placement for de novo or restenotic lesions of the superficial femoral and/or popliteal artery. Baseline and follow-up walking impairment questionnaire (WIQ) scores, Rutherford classifications, and ankle-brachial index (ABI) measurements were obtained. Follow-up was completed at 1, 6, and 12 months. Results: There were 285 diabetic patients and 502 nondiabetic patients treated. There were no significant differences in mean lesion length or lesion calcification between patient groups. Procedural success in both treatment groups was >97 %. There were no significant differences between diabetic and nondiabetic groups in Kaplan-Meier estimates of patency, event-free survival (EFS), or freedom from target lesion revascularization (TLR) at 6 and 12 months. Both groups experienced a significant increase in ABI and WIQ values after treatment, and these improvements were sustained to 12-month follow-up; however, nondiabetic patients had significantly greater 6- and 12-month WIQ scores compared with diabetic patients. Based on covariate analysis, the only factors shown to be significant and to negatively influence patency were longer lesion length (p = 0.009), higher Rutherford classification (p = 0.02), and lack of hypertension (p = 0.02); diabetic status was not found to be a significant factor. Conclusion: Diabetic and nondiabetic patients had similar estimates of primary patency, EFS, and freedom from TLR; however, diabetic patients showed less improvement in WIQ scores compared with nondiabetic patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluorodeoxyglucose Positron Emission Tomography Response and Normal Tissue Regeneration After Stereotactic Body Radiotherapy to Liver Metastases

Purpose: To characterize changes in standardized uptake value (SUV) in positron emission tomography (PET) scans and determine the pace of normal tissue regeneration after stereotactic body radiation therapy (SBRT) for solid tumor liver metastases. Methods and Materials: We reviewed records of patients with liver metastases treated with SBRT to {>=}40 Gy in 3-5 fractions. Evaluable patients had pretreatment PET and {>=}1 post-treatment PET. Each PET/CT scan was fused to the planning computed tomography (CT) scan. The maximum SUV (SUV{sub max}) for each lesion and the total liver volume were measured on each PET/CT scan. Maximum SUV levels before and after SBRT were recorded. Results: Twenty-seven patients with 35 treated liver lesions were studied. The median follow-up was 15.7 months (range, 1.5-38.4 mo), with 5 PET scans per patient (range, 2-14). Exponential decay curve fitting (r=0.97) showed that SUV{sub max} declined to a plateau of 3.1 for controlled lesions at 5 months after SBRT. The estimated SUV{sub max} decay half-time was 2.0 months. The SUV{sub max} in controlled lesions fluctuated up to 4.2 during follow-up and later declined; this level is close to 2 standard deviations above the mean normal liver SUV{sub max} (4.01). A failure cutoff of SUV{sub max} {>=}6 is twice the calculated plateau SUV{sub max} of controlled lesions. Parenchymal liver volume decreased by 20% at 3-6 months and regenerated to a new baseline level approximately 10% below the pretreatment level at 12 months. Conclusions: Maximum SUV decreases over the first months after SBRT to plateau at 3.1, similar to the median SUV{sub max} of normal livers. Transient moderate increases in SUV{sub max} may be observed after SBRT. We propose a cutoff SUV{sub max} {>=}6, twice the baseline normal liver SUV{sub max}, to score local failure by PET criteria. Post-SBRT values between 4 and 6 would be suspicious for local tumor persistence or recurrence. The volume of normal liver reached nadir 3-6 months after SBRT and regenerated within the next 6 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compatibility of Type 304H Stainless Steel in Static Molten FLiBe for Inertial Confinement Fusion Reactors: Role of Impurities and Redox Control

Molten fluoride salts, such as FLiBe (LiF-BeF2), are promising candidates for tritium breeding and heat transfer in fusion reactors, but corrosion of structural materials remains a major challenge. This study investigates the corrosion behavior of austenitic stainless steel 304H in purified and NiF2-containing FLiBe at 500°C and 600°C, focusing on the effects of impurities and redox control. Exposure to purified FLiBe resulted in the concurrent depletion of Cr, Mn, and Fe, with corrosion at 500 °C dominated by the combined oxide formation and elemental dissolution, while at 600°C elemental depletion was predominant. The addition of a controlled NiF2 impurity significantly accelerated corrosion at both temperatures, demonstrating the sensitivity of 304H to the salt redox state. Beryllium additions were effective in mitigating corrosion for both baseline and NiF2-containing FLiBe; minimal depletion of Cr, Mn, and Fe occurred with Be additions as low as 2.5 mg (147 wppm), and no NiBe intermetallics formed at 5 mg (294 wppm), indicating that small Be inventories can provide substantial protection without deleterious phase formation. Thermodynamic equilibrium and coupled thermodynamic-kinetic analyses at the salt-alloy interface suggested low corrosion rates in systems with limited hydrogen fluoride (HF) generation, highlighting the importance of salt redox control. Estimates for a Be addition rate were calculated for the HYLIFE-II fusion reactor that can mitigate corrosion-induced degradation, assuming complete conversion of tritium to tritium fluoride (TF). Overall, 304H shows reasonable compatibility with FLiBe under optimized redox conditions. These results provide quantitative guidance for material selection and salt management in fusion blanket and heat exchanger systems and motivate validation under flowing, nonisothermal, and irradiated conditions.

Pillai, Rishi [ORNL] (ORCID:0000000243688197)↗

Demonstration Project for a Multi-Material Lightweight Prototype Vehicle as Part of the Clean Energy Dialogue with Canada

The intent of the Multi-Material Lightweight Vehicle (“MMLV”) was to assess the feasibility of achieving a significant level of vehicle mass reduction, enabling engine downsizing resulting in a tangible fuel reduction and environmental benefit. The MMLV project included the development of two (2) lightweight vehicle designs, referred to as Mach-I and Mach-II MMLV variants, based on a 2013 Ford production C/D segment production vehicle (Fusion). Weight comparison, life cycle assessment and limited full vehicle testing are included in the project scope. The Mach-I vehicle variant was comprised of materials and processes that are commercially available or previously demonstrated. The 363 kg mass reduction associated with the Mach-I design enabled use of a one-liter, three-cylinder, gasoline turbocharged direct injection engine, maintaining the performance and utility of the baseline vehicle. The full MMLV project produced seven (7) MMLV Mach-I “concept vehicles” which were used for testing and evaluation. The full vehicle tests confirmed that MMLV Mach-I concept vehicle performed approximately equivalent to the baseline 2013 Ford Fusion vehicle thereby validating the design of the multi material lightweight vehicle design. The results of the Life Cycle Assessment, conducted by third party consultant, indicated that if the MMLV Mach-I design was built and operated in North America for 250,000 km (155,343 miles) it would produce significant environmental and fuel economy benefits including a 16% reduction in Global Warming Potential (GWP) and 16% reduction in Total Primary Energy (TPE). The LCA calculations estimated the combined fuel economy of 34 mpg (6.9 l/100 km) associated with the MMLV Mach-I Design compared to 28 mpg (8.4 l/100 km) for the 2013 Ford Fusion.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water Resource Assessment In The New Mexico Permian Basin: BLM 2023 Assessment Report

The Permian Basin is the highest producing oil field in the United States and is comprised of three component basins including; the Midland Basin, Delaware Basin and the Marfa Basin. This report describes the work conducted by Sandia National Laboratories (SNL) for the Bureau of Land Management (BLM) to investigate the occurrence of usable water (quality, and depth to water) in the Delaware Sub-basin of the Permian Basin. High Production Areas (HPAs) were identified for the region based on Reasonable Foreseeable Development Scenario (RFD) published by New Mexico Tech University. HPAs were established based on potential for future development of oil reserves. The study was initiated by the BLM-Carlsbad Field Office (CFO) based on concerns that special protections for groundwater in these HPAs may be warranted. A combination of analysis of existing data and field work to collect new data for analysis were used to complete the investigation objectives. This study summarizes the most recent analyses in an ongoing project and builds on previously completed work as listed in Table 1. Advancements in directional drilling and well completion technologies have resulted in an exponential growth in the use of hydraulic fracturing for oil and gas extraction in the Permian Basin. Within the New Mexico portion of the Delaware Sub-basin, water demand to complete each hydraulically fractured well is estimated to average 7.3 acre-feet (2.4 million gallons), resulting in 30 billion barrels of water over the life of the plan or 1.5 billion barrels per year. This rising demand is creating concern for the regions ability to provide the necessary water in a manner that fulfills BLM’s role of protecting human health and the environment while sustainably meeting the needs of various water users in the region. This report documents water-level and water chemistry baselines to aid the BLM in understanding the regional water supply dynamics under various management, policy, and growth scenarios and to pre-emptively identify risks to water sustainability.

54 ENVIRONMENTAL SCIENCES↗

Development of the IBSAL-SimMOpt Method for the Optimization of Quality in a Corn Stover Supply Chain

Variability on the physical characteristics of feedstock has a relevant effect on the reactor’s reliability and operating cost. Most of the models developed to optimize biomass supply chains have failed to quantify the effect of biomass quality and preprocessing operations required to meet biomass specifications on overall cost and performance. The Integrated Biomass Supply Analysis and Logistics (IBSAL) model estimates the harvesting, collection, transportation, and storage cost while considering the stochastic behavior of the field-to-biorefinery supply chain. This paper proposes an IBSAL-SimMOpt (Simulation-based Multi-Objective Optimization) method for optimizing the biomass quality and costs associated with the efforts needed to meet conversion technology specifications. The method is developed in two phases. For the first phase, a SimMOpt tool that interacts with the extended IBSAL is developed. For the second phase, the baseline IBSAL model is extended so that the cost for meeting and/or penalization for failing in meeting specifications are considered. The IBSAL-SimMOpt method is designed to optimize quality characteristics of biomass, cost related to activities intended to improve the quality of feedstock, and the penalization cost. A case study based on 1916 farms in Ontario, Canada is considered for testing the proposed method. Analysis of the results demonstrates that this method is able to find a high-quality set of non-dominated solutions.

09 BIOMASS FUELS↗

Sensitivity study for a remotely piloted microwave-powered sailplane used as a high-altitude observation

The sensitivity of several performance characteristics of a proposed design for a microwave-powered, remotely piloted, high-altitude sailplane to changes in independently varied design parameters was investigated. Results were expressed as variations from baseline values of range, final climb altitude and onboard storage of radiated energy. Calculated range decreased with increases in either gross weight or parasite drag coefficient; it also decreased with decreases in lift coefficient, propeller efficiency, or microwave beam density. The sensitivity trends for range and final climb altitude were very similar. The sensitivity trends for stored energy were reversed from those for range, except for decreasing microwave beam density. Some study results for single parameter variations were combined to estimate the effect of the simultaneous variation of several parameters: for two parameters, this appeared to give reasonably accurate results.

Turriziani, R. V.↗

Progress report on the Block 1 VLBI correlator implementation

The Block 1 VLBI Processor Subsystem (VPS) of the Very Long Baseline Interferometry (VLBI) System for the determination of station clock-sync parameters, UT1 and polar motion, and station platform parameters and for use in spacecraft tracking is discussed. The Block 1 VPS performs three basic functions: it receives the 500 kbit/sec video data over the GCF wideband data lines from each of the three DSN 64 m antennas; it cross correlates data; and it performs several postcorrelation data reduction operations on the correlated data including calibration, editing, and parameter estimation.

Peterson, J. C.↗

Navigation of space VLBI missions: Radioastron and VSOP

In the mid-1990s, Russian and Japanese space agencies will each place into highly elliptic earth orbit a radio telescope consisting of a large antenna and radio astronomy receivers. Very long baseline interferometry (VLBI) techniques will be used to obtain high resolution images of radio sources observed by the space and ground based antennas. Stringent navigation accuracy requirements are imposed on the space VLBI missions by the need to transfer an ultra-stable ground reference frequency standard to the spacecraft and by the demands of the VLBI correlation process. Orbit determination for the mission will be the joint responsibility of navigation centers in the U.S., Russia, and Japan with orbit estimates based on combining tracking data from NASA, Russian, and Japanese sites. This paper describes the operational plans, the inter-agency coordination, and data exchange between the navigation centers required for space VLBI navigation.

Ellis, Jordan↗

Influence of Spanwise Boundary Conditions on Slat Noise Simulations

The slat noise from the 30P/30N high-lift system is being investigated through computational fluid dynamics simulations with the OVERFLOW code in conjunction with a Ffowcs Williams-Hawkings acoustics solver. In the present study, two different spanwise grids are being used to investigate the effect of the spanwise extent and periodicity on the near-field unsteady structures and radiated noise. The baseline grid with periodic boundary conditions has a short span equal to 1/9th of the stowed chord, whereas the other, longer span grid adds stretched grids on both sides of the core, baseline grid to allow inviscid surface boundary conditions at both ends. The results indicate that the near-field mean statistics obtained using the two grids are similar to each other, as are the directivity and spectral shapes of the radiated noise. However, periodicity forces all acoustic waves with less than one wavelength across the span to be two-dimensional, without any variation in the span. The spanwise coherence of the acoustic waves is what is needed to make estimates of the noise that would be radiated from realistic span lengths. Simulations with periodic conditions need spans of at least six slat chords to allow spanwise variation in the low-frequencies associated with the peak of broadband slat noise. Even then, the full influence of the periodicity is unclear, so employing grids with a fine, central region and highly stretched meshes that go to slip walls may be a more efficient means of capturing the spanwise decorrelation of low-frequency acoustic phenomena.

Lockard, David P.↗

Validation of High-Resolution CFD Method for Slosh Damping Extraction of Baffled Tanks

Determination of slosh damping is a very challenging task as there is no analytical solution. The damping physics involve the vorticity dissipation which requires the full solution of the nonlinear Navier-Stokes equations. As a result, previous investigations and knowledge were mainly carried out by extensive experimental studies. A Volume-Of-Fluid (VOF) based CFD program developed at NASA MSFC was applied to extract slosh damping in a baffled tank from the first principle. First, experimental data using water with subscale smooth wall tank were used as the baseline validation. CFD simulation was demonstrated to be capable of accurately predicting natural frequency and very low damping value from the smooth wall tank at different fill levels. The damping due to a ring baffle at different liquid fill levels from barrel section and into the upper dome was then investigated to understand the slosh damping physics due to the presence of a ring baffle. Based on this study, the Root-Mean-Square error of our CFD simulation in estimating slosh damping was less than 4.8%, and the maximum error was less than 8.5%. Scalability of subscale baffled tank test using water was investigated using the validated CFD tool, and it was found that unlike the smooth wall case, slosh damping with baffle is almost independent of the working fluid and it is reasonable to apply water test data to the full scale LOX tank when the damping from baffle is dominant. On the other hand, for the smooth wall, the damping value must be scaled according to the Reynolds number. Comparison of experimental data, CFD, with the classical and modified Miles equations for upper dome was made, and the limitations of these semi-empirical equations were identified.

Yang, H. Q.↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of the hybrid sulfur cycle for use with concentrated solar heat. I. Conceptual design

We propose a detailed conceptual design of a solar hybrid sulfur (HyS) cycle. Numerous design tradeoffs, including process operating conditions and strategies, methods of integration with solar energy sources, and solar design options were considered. A baseline design was selected, and process flowsheets were developed. Pinch analyses were performed to establish the limiting energy efficiency. Detailed material and energy balances were completed, and a full stream table prepared. Design assumptions include use of: location in the southwest US desert, falling particle concentrated solar receiver, indirect heat transfer via pressurized helium, continuous operation with thermal energy storage, liquid-fed electrolyzer with PBI membrane, and bayonet-type acid decomposer. Thermochemical cycle efficiency for the HyS process was estimated to be 35.0%, LHV basis. The solar-to-hydrogen (STH) energy conversion ratio was 16.9%. This thus exceeds the Year 2015 DOE STCH target of STH >10%, and shows promise for meeting the Year 2020 target of 20%.

08 HYDROGEN↗

Experimental Tests of Lateral Bedload Transport Induced by a Yawed Submerged Vane Array in Open-Channel Flows

This work proposes the use of an array of yawed porous vanes to control the lateral bedload transport by locally steering bedform migration and maximize the amount of sediments redirected toward a potential sediment extraction system or bypass channel. A laboratory experiment was conducted in a quasifield-scale channel with an array of permeable vanes installed on one side, in live-bed conditions under bedload dominant regime, i.e., negligible suspended load. A baseline experiment without vanes was also performed for comparison. The evolution of migrating bedforms of different scales was tracked in space and time using a high-resolution, state-of-the-art laser scanning device. The bedload transport rate in the streamwise direction was first calculated using bedforms’ geometry and migration velocity, and then spatially distributed over the entire monitored area using a new Eulerian-averaged grid-mapping method. This allowed us to introduce a new methodology to estimate the lateral bedload transport using control volume theory and applying mass conservation. Quantitative assessments of lateral bedload transport along the channel yield consistent results, suggesting that the vanes effectively move sediments laterally as intended. Under the investigated setup, the maximum lateral sediment transport rate ranges from 9% to 18% of the whole domain-averaged streamwise transport rate. The developed methodology also allowed to identify the location where sediment capture could be maximized for the given vane spatial distribution.

42 ENGINEERING↗

Accurate radio and optical positions for southern radio sources

Accurate radio positions with a precision of about 0.01 arcsec are reported for eight compact extragalactic radio sources south of -45-deg declination. The radio positions were determined using VLBI at 8.4 GHz on the 9589 km Tidbinbilla (Australia) to Hartebeesthoek (South Africa) baseline. The sources were selected from the Parkes Catalogue to be strong, flat-spectrum radio sources with bright optical QSO counterparts. Optical positions of the QSOs were also measured from the ESO B Sky Survey plates with respect to stars from the Perth 70 Catalogue, to an accuracy of about 0.19 arcsec rms. These radio and optical positions are as precise as any presently available in the far southern sky. A comparison of the radio and optical positions confirms the estimated optical position errors and shows that there is overall agreement at the 0.1-arcsec level between the radio and Perth 70 optical reference frames in the far south.

Harvey, Bruce R.↗

Models of Sector Flows Under Local, Regional and Airport Weather Constraints

Recently, the ATM community has made important progress in collaborative trajectory management through the introduction of a new FAA traffic management initiative called a Collaborative Trajectory Options Program (CTOP). FAA can use CTOPs to manage air traffic under multiple constraints (manifested as flow constrained areas or FCAs) in the system, and it allows flight operators to indicate their preferences for routing and delay options. CTOPs also permits better management of the overall trajectory of flights by considering both routing and departure delay options simultaneously. However, adoption of CTOPs in airspace has been hampered by many factors that include challenges in how to identify constrained areas and how to set rates for the FCAs. Decision support tools providing assistance would be particularly helpful in effective use of CTOPs. Such DSTs tools would need models of demand and capacity in the presence of multiple constraints. This study examines different approaches to using historical data to create and validate models of maximum flows in sectors and other airspace regions in the presence of multiple constraints. A challenge in creating an empirical model of flows under multiple constraints is a lack of sufficient historical data that captures diverse situations involving combinations of multiple constraints especially those with severe weather. The approach taken here to deal with this is two-fold. First, we create a generalized sector model encompassing multiple sectors rather than individual sectors in order to increase the amount of data used for creating the model by an order of magnitude. Secondly, we decompose the problem so that the amount of data needed is reduced. This involves creating a baseline demand model plus a separate weather constrained flow reduction model and then composing these into a single integrated model. A nominal demand model is a flow model (gdem) in the presence of clear local weather. This defines the flow as a function of weather constraints in neighboring regions, airport constraints and weather in locations that can cause re-routes to the location of interest. A weather constrained flow reduction model (fwx-red) is a model of reduction in baseline counts as a function of local weather. Because the number of independent variables associated with each of the two decomposed models is smaller than that with a single model, need for amount of data is reduced. Finally, a composite model that combines these two can be represented as fwx-red (gdem(e), l) where e represents non-local constraints and l represents local weather. The approaches studied to developing these models are divided into three categories: (1) Point estimation models (2) Empirical models (3) Theoretical models. Errors in predictions of these different types of models have been estimated. In situations when there is abundant data, point estimation models tend to be very accurate. In contrast, empirical models do better than theoretical models when there is some data available. The biggest benefit of theoretical models is their general applicability in wider range situations once the degree of accuracy of these has been established.

Kulkarni, Deepak↗

Models of Sector Aircraft Counts in the Presence of Local, Regional and Airport Constraints

Recently, the ATM community has made important progress in collaborative trajectory management through the introduction of a new FAA traffic management initiative called a Collaborative Trajectory Options Program (CTOP). FAA can use CTOPs to manage air traffic under multiple constraints (manifested as flow constrained areas or FCAs) in the system, and it allows flight operators to indicate their preferences for routing and delay options. CTOPs also permits better management of the overall trajectory of flights by considering both routing and departure delay options simultaneously. However, adoption of CTOPs in airspace has been hampered by many factors that include challenges in how to identify constrained areas and how to set rates for the FCAs. Decision support tools providing assistance would be particularly helpful in effective use of CTOPs. Such DSTs tools would need models of demand and capacity in the presence of multiple constraints. This study examines different approaches to using historical data to create and validate models of maximum flows in sectors and other airspace regions in the presence of multiple constraints. A challenge in creating an empirical model of flows under multiple constraints is a lack of sufficient historical data that captures diverse situations involving combinations of multiple constraints especially those with severe weather. The approach taken here to deal with this is two-fold. First, we create a generalized sector model encompassing multiple sectors rather than individual sectors in order to increase the amount of data used for creating the model by an order of magnitude. Secondly, we decompose the problem so that the amount of data needed is reduced. This involves creating a baseline demand model plus a separate weather constrained flow reduction model and then composing these into a single integrated model. A nominal demand model is a flow model (gdem) in the presence of clear local weather. This defines the flow as a function of weather constraints in neighboring regions, airport constraints and weather in locations that can cause re-routes to the location of interest. A weather constrained flow reduction model (fwx-red) is a model of reduction in baseline counts as a function of local weather. Because the number of independent variables associated with each of the two decomposed models is smaller than that with a single model, need for amount of data is reduced. Finally, a composite model that combines these two can be represented as fwx-red (gdem(e), l) where e represents non-local constraints and l represents local weather. The approaches studied to developing these models are divided into three categories: (1) Point estimation models (2) Empirical models (3) Theoretical models. Errors in predictions of these different types of models have been estimated. In situations when there is abundant data, point estimation models tend to be very accurate. In contrast, empirical models do better than theoretical models when there is some data available. The biggest benefit of theoretical models is their general applicability in wider range situations once the degree of accuracy of these has been established.

Kulkarni, Deepak↗

An Assessment of and Access to NASA CERES Hourly Solar Irradiance Data Products Using POWER Web Services

The National Aeronautics and Space Administration’s (NASA) Clouds and Earth’s Radiant Energy System (CERES) Mission has been providing surface solar irradiance data products since March 2000. With an emphasis on global climate quality data products, CERES produces a suite of data parameters related to both the inputs and the observed and measured solar irradiance components at the top-of-atmosphere and at the surface. This paper discusses the global CERES SYN1Deg (Synoptic 1x1 degree resolution) solar irradiance data products, shows that the accuracy of the global horizontal irradiance (GHI) at the hourly time scale is <1% for bias and 24% RMS compared to the Baseline Surface Radiation Network (BSRN) measurements. This paper then shows the accuracy of the direct and diffuse components and a proposed “bias” correction based upon the solar zenith angle dependence that provides accuracy useful for solar applications on a global basis for all sunlit conditions. Lastly, a brief description of how to obtain these hourly solar irradiance products based upon SYN1Deg using the NASA’s Prediction of Worldwide Energy Resource (POWER) web services portal is given so users can utilize these estimates for testing and evaluation.

Surface solar irradiance↗