At least 1,783 records · Page 99

Galactic-latitude dependence of low-energy diffuse X-rays.

A flux of low-energy diffuse X-rays has been observed which is qualitatively well correlated with 21-cm column densities of hydrogen from intermediate to high galactic latitude. The intensity exceeds that predicted by an extrapolation to low energies of the power-law spectrum observed above 1 keV. The observed X-ray intensity and the apparent correlation with interstellar hydrogen is accounted for by an additional component of extragalactic radiation plus a local component. For the latter, we cannot exclude the possibility that the X-rays are produced in the upper atmosphere. In addition, we have observed a large flux of X-rays near the galactic plane and a prominent feature in the constellation Gemini.

Yentis, D. J.↗

Observation of the core of the Perseus cluster with the Einstein solid state spectrometer: Cooling gas and elemental abundances

Solid State Spectrometer observations of the core of the Perseus cluster have resulted in the detection of X-ray emission lines due to Si, S, and Fe. Analysis of the spectrum indicates that the X-ray emission has at least two characteristic temperatures. This is interpreted in the framework of radiative accretion in the core of the cluster. The derived parameters are a cooling time tc less than 2 x 109 yrs for the low temperature gas, a mass accretion rate of approximately 300 Mo/yr and a characteristic size of 10 to 20 Kpc for the cool gas. The Fe abundance in the core, approximately 0.4, is similar to the Fe abundance averaged over the whole cluster indicating that Fe emission is not strongly concentrated about NGC 1275. The Si and S abundances are consistent with solar values.

Mushotzky, R. F.↗

AGN Obscuration Through Dusty Infrared Dominated Flows. II. Multidimensional, Radiation-Hydrodynamics Modeling

We explore a detailed model in which the active galactic nucleus (AGN) obscuration results from the extinction of AGN radiation in a global ow driven by the pressure of infrared radiation on dust grains. We assume that external illumination by UV and soft X-rays of the dusty gas located at approximately 1pc away from the supermassive black hole is followed by a conversion of such radiation into IR. Using 2.5D, time-dependent radiation hydrodynamics simulations in a ux-limited di usion approximation we nd that the external illumination can support a geometrically thick obscuration via out ows driven by infrared radiation pressure in AGN with luminosities greater than 0:05 L(sub edd) and Compton optical depth, Tau(sub T) approx > & 1.

Dorodnitsyn, Anton↗

X-ray Security Imaging on Personal Dosimetry

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiobiological Studies Using Cs-137 Gamma or 320 kV X Rays

There are numerous self-shielded research irradiators used in various facilities throughout the United States. The irradiators employ radioactive sources containing either 137 Cs or 60 Co and the irradiators are used for a variety of radiobiological investigations involving cellular and/or animal models. A report from the National Academy of Sciences described security issues associated with particular radiation sources and the desire for their replacement with suitable X-ray irradiators. One possible replacement would be a 320 kV X-ray irradiator. The participants in this research successfully performed in vivo radiobiological studies involving mice exposed to filtered (HVL ≈ 4 mm Cu) 320 kV X rays. Two publications (one published and one submitted at the publishing of this report) documenting key findings are provided in Appendices A and B of this report. The 320 kV X rays were found suitable for in vivo (in mice) cell survival studies and are expected to be suitable for bone marrow transplantation studies using mice but this needs to be experimentally validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coherent emission from surface Josephson plasmons in striped cuprates

The interplay between charge order and superconductivity remains one of the central themes of research in quantum materials. In the case of cuprates, the coupling between striped charge fluctuations and local electromagnetic fields is especially important, as it affects transport properties, coherence, and dimensionality of superconducting correlations. Here, we study the emission of coherent terahertz radiation in single-layer cuprates of the La 2-x Ba x CuO 4 family, for which this effect is expected to be forbidden by symmetry. We find that emission vanishes for compounds in which the stripes are quasi-static but is activated when c-axis inversion symmetry is broken by incommensurate or fluctuating charge stripes, such as in La 1.905 Ba 0.095 CuO 4 and in La 1.845 Ba 0.155 CuO 4 . In this case, terahertz radiation is emitted by surface Josephson plasmons, which are generally dark modes, but couple to free space electromagnetic radiation because of the stripe modulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extreme γ –Ray Radiation Tolerance of Spectrometer–Grade CsPbBr 3 Perovskite Detectors

The perovskite compound CsPbBr 3 has recently been discovered as a promising room-temperature semiconductor radiation detector, offering an inexpensive and easy-to-manufacture alternative to the current benchmark material Cd 1–x Zn x Te (CZT). The performance of CsPbBr 3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co-60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. Notably, these results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr 3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma-ray radiation.

36 MATERIALS SCIENCE↗

The High Energy Astronomy Observatory X-ray Telescope

The High Energy Astronomy Observatory-Mission B (HEAO-B) is a satellite observatory for the purpose of performing a detailed X-ray survey of the celestial sphere. Measurements will be made of stellar radiation in the range 0.2 through 20 keV. The primary viewing requirement is to provide final aspect solution and internal alignment information to correlate an observed X-ray image with the celestial sphere to within one-and-one-half arc seconds. The Observatory consists of the HEAO Spacecraft together with the X-ray Telescope. The Spacecraft provides the required attitude control and determination system, data telemetry system, space solar power system, and interface with the launch vehicle. The X-ray Telescope includes a high resolution mirror assembly, optical bench metering structure, X-ray detectors, detector positioning system, detector electronics and aspect sensing system.

Miller, R.↗

ROSAT observations of the supernova remnant 3C 400.2

We have used the ROSAT point source proportional counter (PSPC) to examine the X-ray emission from 3C 400.2, a supernova remnant (SNR) which is a member of a class of remnants with limb-brightened radio and centrally condensed X-ray morphologies. The X-ray emission fills the radio shell and is characterized by an interior peak in the northwest region of the remnant. Otherwise, the surface brightness has a relatively smooth distribution. The X-ray peak is not correlated with any radio features or with the observed optical filaments. The PSPC X-ray spectrum is not well fitted by a power-law model but can be described in terms of thermal emission from a hot plasma with solar abundances. The only point source along the line of sight to the SNR is associated with a bright foreground F8 star. Thus the X-ray emission from 3C 400.2 is unlikely to be due to synchrotron radiation from an active pulsar. If the emission arises from a thermal plasma and the absorbing column along the line of sight to 3C 400.2 is 7.8 x 10(exp 21)sq cm, then the temperature of the plasma is 0.27 keV, and the 0.4-2.4 keV X-ray luminosity is 1.3 x 10(exp 36) ergs/s for an assumed distance of 6 kpc. An X-ray hardness ratio map shows a slight increase in the hardness of the emission in the regions of the remnant with a higher X-ray surface brightness. Assuming uniform absorption across the remnant, this increase implies the temperature is approximately 1.5 times greater in the high surface brightness regions of SNR. The relatively uniform spectrum and the anticorrelation between X-ray and radio features seems to rule out the possibility that 3C 400.2 is actually two overlapping or interacting SNRs. The morphology of 3C 400.2 can be explained in terms of a multiphase interstellar medium (ISM) in which the primary shock is expanding into an ISM studded with dense cloudlets, if the clouds are evaporated or disrupted on a timescale which is long compared to the age of the SNR. It may also be possible to explain the emission in terms of the interaction of the SNR with a massive wind-driven shell, although the existing models for the evolution of A SNR in this environment suggest that the H-alpha luminosity should be much larger than the X-ray luminosity, which is not observed. We cannot completely rule out the possibility that 3C 400.2's appearance as a centrally peaked X-ray SNR is the result of an interaction between the remnant and a cloud along the line of sight, although this seems unlikely.

Saken, Jon M.↗

Probing Diffuse Polymer Brush Interfaces Using Resonant Soft X-ray Scattering

The success of a neutron or x-ray scattering experiment relies on sufficient signal from the system being studied. The intensity of scattered radiation depends on instrument resolution, the structure of the scattering elements, and the interaction between the incident radiation and the sample—so-called ‘scattering contrast’. The contrast depends on the square of the difference in the scattering length densities (SLDs) for each component, and each SLD depends on the atoms and radiation involved (eq. 1). For neutrons, the scattering lengths bi are specific to the type of nuclei involved. For conventional x-ray scattering, b i depends on the electron density and thus the atomic number Z.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compact radio source 1413 + 135 is a far-IR extragalactic object

The radio source 1413 + 135 is shown to be one of the strongest known emitters of millimeter radiation. The energy distribution of this object, measured between meter and X-ray wavelengths, reveals that most of the power emitted by this object comes out at millimeter and far-IR wavelengths. If the emission at 1 mm is due to incoherent synchrotron radiation, then the source must be very compact, with a size around 25 micron arc sec, and contain a magnetic field larger than 10 G. The steep spectral index in the near-IR is attributed to a high-energy cutoff in the distribution of synchrotron emitting electrons at a Lorentz factor of approximately 300.

Beichman, C. A.↗

Spectroscopic analysis of radiation-generated changes in tensile properties of a polyetherimide film

The effects of electron radiation on Ultem, a polyetherimide were studied for doses from 2 x 10 to the 9th power to 6 x 10 to the 9th power rad. Specimens were studied for tensile property testing and for electron paramagnetic resonance and infrared spectroscopic measurements of molecular structure. A Faraday cup design and a method for remote temperature measurement were developed. The spectroscopic data show that radiation caused dehydrogenation of methyl groups, rupture of main-chain ether linkage, and opening of imide rings, all to form radicals and indicate that the so-formed atomic hydrogen attached to phenyl radicals, but not to phenoxyl radicals, which would have formed hydroxyls. The observed decays of the radiation-generated phenoxyl, gem-dimethyl, and carbonyl radicals were interpreted as a combining of the radicals to form crosslinking. This crosslinking is the probable cause of the major reduction in the elongation of the tensile specimens after irradiation. Subsequent classical solubility tests indicate that the irradiation caused massive crosslinking.

Long, E. R., Jr.↗

X-ray Security Imaging on Personal Dosimetry [Slides]

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hot bubbles in a magnetic interstellar medium - Another look at the soft X-ray background

An attempt is made to understand the origin and properties of an isolated local bubble of hot gas using models of explosive events in a magnetic interstellar medium which mimic the local bubble in terms of the C band X-ray surface brightness and radius. The residual bubble of hot gas reaches a maximum size with an internal pressure below ambient, and then shrinks to smaller volume and a pressure nearly equal to ambient. The X-ray brightness reaches its minimum at the time of maximum radius and rises thereafter. It is found that the bubble growth must have been confined by a probably unacceptably large external pressure in order for the hot gas in the maximally extended cavity to radiate at a rate like that observed in the soft X-ray background.

Edgar, Richard J.↗

A versatile Johansson-type tender x-ray emission spectrometer

We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6–5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (~0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (~30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗