Tank Farm Safety Programmable System Software Management Plan

This Software Management Plan (SMP) applies to the configurable programmable logic controller (PLC) software configured as the Tank Farms Safety Programmable System (TFSPS). The TFSPS is identified as a safety-significant (SS) system to prevent loss of the safety function of SS structures, systems, and components (SSC). The TFSPS software is classified as grade level A configurable safety software. The TFSPS consists of safety instrumented systems (SIS) and safety instrumented alarm (SIA) systems.The purpose of this management plan is to describe how Washington River Protection Solutions (WRPS) will configure and manage the TFSPS software and the associated software life cycle (SLC). TFSPS software shall be configured by Process and Control Systems Engineering (P&CSE) as grade level A safety software for use by Production Operations as the primary stakeholders.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Risk of Precipitating Aluminum in Hanford DFLAW Feed Compositions

The Hanford Tank Operations Contractor (TOC), Washington River Protection Solutions (WRPS), developed the Tank Waste Disposition Integrated Flowsheet that defines process flowsheets during each phase of the Waste Treatment and Immobilization Plant transition to full operation. The TOC requested Savannah River National Laboratory (SRNL) personnel to perform a review of gibbsite precipitation risks for the Low-Activity Waste Pretreatment System (LAWPS) and Tank Side Cesium Removal (TSCR) processes at Hanford during the Direct Feed Low-Activity Waste (DFLAW) operational phase of the Hanford Low-Activity Waste (LAW) Vitrification Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Analysis of Actual and Potential Atmospheric Dispersion of Plutonium-239 from the Hanford Site Plutonium Finishing Plant

This report presents the results of two studies conducted to assess actual and potential plutonium-239 environmental contamination during demolition of the Plutonium Finishing Plant (PFP) at the Hanford Site near Richland, Washington. The assessments described herein were conducted by the National Atmospheric Release Advisory Center (NARAC) at Lawrence Livermore National Laboratory (LLNL). The overall objective of NARAC’s work is to help determine if contamination levels that warrant controls will extend beyond the established radiological control boundaries around the Hanford Site PFP in the course of further decontamination and demolition activities.

54 ENVIRONMENTAL SCIENCES↗

NDE Technology Development Program for Non-Visual Volumetric Inspection Technology: Technology Screening Report

The Pacific Northwest National Laboratory (PNNL) located in Richland, Washington, hosted and administered a Technology Screening test that allowed four different participants to demonstrate the NDE volumetric inspection technologies that were proposed in response to the WRPS EOI. This document provides a Technology Screening test report for the initial part of Phase I of a three-phase NDE Technology Development Program designed to identify and mature a system or set of non-visual volumetric NDE technologies for Hanford DST primary liner bottom inspection. Phase I of the program will baseline the performance of current or emerging non-visual volumetric NDE technologies for their ability to detect and characterize primary liner bottom flaws, and identify candidate technologies for adaptation and maturation for Phase II of the program.

42 ENGINEERING↗

Monitoring the Prototype Hanford Barrier – Fiscal Year 2018 Report

After a decade of development activities from 1983 to 1993, the 2.5-ha (6.2-acre) Prototype Hanford Barrier (PHB) was constructed between late 1993 and 1994 over the 216-B-57 Crib in the 200 East Area (46°34’01.23”N, 119°32’28.43”W) at the Hanford Site in southeastern Washington State. The PHB construction was part of a Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) treatability test of barrier performance for the 200-BP-1 Operable Unit. The CERCLA treatability test was an enhanced precipitation stress test from water year 1995 (WY95) to WY97 to determine barrier response to extreme precipitation events. A controlled fire test was conducted in 2008 to examine the recovery of vegetation under the natural condition and the performance of the barrier with limited vegetation

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System-Integration and Field-Testing Report

We have designed a system for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—OSIRIS —gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC IDM-200V, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. Spectral data analysis is similar to that performed by traditional gamma-ray spectrometers, except the OSIRIS gamma-ray spectral data are filtered to display only radioisotopic information relevant to CTBT on-site inspections, for example, the fission-product isotope Zr-95 and its daughter isotope Nb-95. The OSIRIS software assists the user during operation with software checklists for startup and shutdown, and menu-selected display windows during energy calibration and data acquisition. OSIRIS can be operated in either sample-counting mode or the in-situ mode. In this report, the extensive system-integration tests of the OSIRIS system carried out in 2015-2017 are described, including tests at Idaho National Laboratory, at the Nevada National Security Site (formerly, the Nevada Test Site), and at Pacific Northwest National Laboratory in Richland, Washington. We also note recent software enhancements and the steps to our successful commercialization of OSIRIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UW Translational Imaging Biomarker and Therapeutic Development

The development and validation of radiotracers is a critical step in the clinical translation of molecular imaging and theranostics to support personalized medicine. The proposed program is to support such efforts by an interdisciplinary team of investigators at the University of Washington (UW) and Fred Hutchinson Cancer Research Center (FHCRC) and to provide opportunities for trainees to learn the spectrum of translational research in imaging biomarkers and therapeutic development. The proposed translational research projects include "Preclinical Evaluation of PET Imaging for Use in the Translation of Targeted Alpha Therapy of Blood-Related Cancers to Clinical Studies" (Project 1-Wilbur, leader); "Hypoxia Imaging: Radiopharmaceuticals, Preclinical Studies, Mechanisms and Clinical trials" (Project 2-Krohn, leader); and "Diagnostic Applications of Radiolabeled Biologics in Solid Tumors" (Project 3-Minoshima, leader). These projects use radiotracers with long half-lives, such as F-18, Zr-89, I-124, and At-211, that can potentially be handled commercially if translation research is successful. The proposed research method is to use an interdisciplinary 'team' of expert investigators and trainees working on a specific project for 1 or 2 years along the timeline and milestones set by the Program Directors. Each team includes 1) a clinician expert; 2) a radiochemistry expert; 3) an imaging or radiation therapy expert; 4) a physicist; 5) trainees; and 6) a UW technology transfer officer. Two groups of trainees will be involved: clinical and basic science (radiochemistry) trainees. Clinical trainees will be recruited from 3 training programs: Nuclear Medicine Resident Program; Radiology Residency Program; and Residency Program in Radiation Oncology. Basic science trainees will be graduate students from degree-awarding departments (chemistry, material sciences, bioengineering) or post-doctoral students (radiology, radiation oncology, or collaborating departments). A goal of training is to develop future investigators who will be able to conduct independent translational research with knowledge and expertise earned in this interdisciplinary team environment. To address clinically relevant questions, the program will organize regular brainstorming meetings participated by clinicians from various medical disciplines; program investigators; trainees; technology transfer officers to discuss medical questions, relevant targets, and technical feasibility. UW provides outstanding research and clinical facilities and resources that can be accessed by investigators. The Departments of Radiology and Radiation Oncology at UW have been at the forefront of translational imaging and therapeutics research efforts in cancer, neurological disorders, and cardiovascular diseases. This funding opportunity will solidify ongoing efforts of interdisciplinary collaborations at UW into a cohesive program that will train a new generation of investigators. This will, in turn, accelerate the translational potential of new radiotracers by rapid developments of proof-of-concept and first-in-man studies along with in vivo validations in a clinically relevant context.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interaction between Heat Pump Water Heaters or Other Internal Point Source Loads and a Central Heating System

Water heating represents approximately 18% of residential energy consumption, or 4.6 quadrillion Btus of source energy use annually (EIA 2009). Heat pump water heaters (HPWHs) offer an efficient option for residential water heating, with the ability to reduce water heating energy consumption by up to 63%. Previous research has demonstrated the laboratory performance of HPWHs and has shown savings of 43 to 62% on water heating energy consumption are possible, based on field tests (Ecotope 2015). In order to achieve such high efficiencies, HPWHs employ a refrigeration cycle to move heat from the ambient air into the water. Therefore, when HPWHs are installed in conditioned space, they will remove heat from that space which can help the HVAC system in the cooling season and require additional energy from the HVAC system in the heating season. This project provides an unbiased evaluation of the space conditioning interactions between a HPWH and the heating system in several locations throughout the home to further our understanding of the impact that HPWHs have on space conditioning loads. This report explores the HPWH interaction factor from several perspectives: (1) a theoretical analysis, (2) a review of previous literature, and (2) an experimental assessment. The experiments were conducted in PNNL’s side-by-side Lab Homes, which provide a platform for evaluating energy-saving and grid-responsive technologies in a controlled environment. The PNNL Lab Homes are two factory-built homes installed on PNNL’s campus in Richland, Washington. The homes represent existing homes, which account for approximately 99% of occupied homes in the U.S. These 1500 ft2 homes have three bedrooms, two bathrooms, and are equipped with 7.7 HSPF heat pump and an electric forced air furnace. Both homes have R-22 floors, R-11 walls and R-22 ceiling insulation levels, with double-pane clear glass windows. The results of this experiment verified that the energy use of the HVAC system increases as a point source cooling load, like a HPWH, is moved closer to the thermostat. The opposite is also true, as a point source heating load is moved closer to the thermostat, the heating load decreases. The results show between 30-40% difference between the interaction that this type of load has when it is placed in the master bathroom compared to the living room for the PNNL Lab Homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final report: Understanding influence of thermal history and glass chemistry on kinetics of phase separation and crystallization in borosilicate glass-ceramic waste forms for aqueous reprocessed high level waste

This report provides an overview of the research activities conducted over the three-year period, October 1, 2015 to September 30, 2018. The project consisted of the US DOE component and a parallel project funded by the UK’s EPSRC. The US project is reported here, with some overview of the UK project results. The project was designed to be highly collaborative, including work in the US by Washington State University and Rutgers University, and in the UK by the University of Sheffield and the University of Warwick. Pacific Northwest National Laboratory supported the US project with some synthesis and some characterization. The overall program had two aims: (Aim 1) Understand fundamental mechanisms of the phase transitions leading to the conversion of melt to multiphase glass-ceramic as a function of composition and cooling rate; (Aim 2) Understand influence of glass chemistry on kinetics of phase separation and crystallization. This report includes the summary of the project objectives, approaches, results and deliverables.

36 MATERIALS SCIENCE↗

Monitoring the Prototype Hanford Barrier – Fiscal Year 2017 Report

After a decade of development activities from 1983 to 1993, the 2.5-ha (6.2-acre) Prototype Hanford Barrier (PHB) was constructed between late 1993 and 1994 over the 216-B-57 Crib in the 200 East Area (46°34’01.23”N, 119°32’28.43”W) at the Hanford Site in southeastern Washington State. The PHB construction was part of a Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) treatability test of barrier performance for the 200-BP-1 Operable Unit. The CERCLA treatability test was an enhanced precipitation stress test during water year 1995 (WY95) to WY97 to determine barrier response to extreme precipitation events. A controlled fire test was conducted in 2008 to examine the recovery of vegetation under the natural condition and the performance of the barrier with limited vegetation.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Remediation Technologies for Iodine-129: FY18 Bench Scale Results

At the U.S. Department of Energy’s (DOE’s) Hanford Site, located in southeastern Washington State, 129 I was produced as a byproduct of nuclear fission in the site’s nine Pu production reactors. Currently, there are large dilute 129 I groundwater plumes at Hanford, including a groundwater plume in the 200-UP-1 operable unit (OU) located within the Central Plateau. The interim Record of Decision (ROD) for the 200-UP-1 OU requires that DOE evaluate potential treatment options for I-129 before a final ROD is issued. A remedy evaluation plan was subsequently published and identified the approach for this effort. The laboratory evaluation reported herein is part of the remedy evaluation. This report builds from information gathered in previous literature reviews of potential remedy technologies and provides laboratory testing results for promising candidates in support of determining which candidates warrant additional evaluation through treatability testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold Cap Bubble Topology

The feed composition of a high level nuclear waste (HLW) glass melter establishes the overall melting rate by influencing the thermo-physical and morphological properties of a relatively insulating cold cap layer over the molten phase. Data from X ray tomography of laboratory scale quenched cold caps provide insight into the distribution and morphology of bubbles, collectively known as primary foam, within this layer for various feed compositions at temperatures between 600°C and 1040°C. The images were digitally segmented to capture features of interest, then processed to obtain statistics that characterize the cold cap structure, including total pellet volume, void fraction, bubble radius distribution and morphology as a function of temperature. These statistics will be used to analyze the melting behavior of the waste glass as a function of silicate content. This temperature-dependent morphological data can be used in future investigations to synthetically generate cold cap structures for use in models of heat transfer through the upper layer of a HLW glass melter, with emphasis on nuclear waste remediation application at the Hanford Site in Washington, USA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Critical Review of Ion Exchange in Nuclear Waste Glasses to Support the Immobilized Low-Activity Waste Integrated Disposal Facility Rate Model

There are over 50 million gallons of waste in underground tanks at the Hanford site in Washington State which was generated as a byproduct of nuclear materials fabrication for United States strategic defensive purposes. The waste, also known as high-level waste (HLW), is comprised of both radioactive and non-radioactive contaminants. To deal with the tank waste, the United States Department of Energy (DOE) plans to separate out the liquid, or supernatant, and salt-cake portions and treat them as low-activity waste (LAW). The LAW and HLW will be vitrified in separate facilities at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The LAW will be disposed of at the on-site Integrated Disposal Facility (IDF). The main species of concern in the immobilized low-activity waste (ILAW) include 99 Tc, 129 I, and U and other non-radioactive contaminants. Ultimately, it must be demonstrated that the contaminants released from the waste form pose minimal risk to humans and the environment. To aid in this demonstration, work is currently being done to expand the understanding of long-term glass waste form behavior, especially with regards to exposure to aqueous environments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Ion Exchange Using Crystalline Silicotitanate with 5.6 M Sodium Simulant

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering to remove solids and processing through ion exchange columns to remove cesium. The ion exchange media is currently (since 2018) targeted to be crystalline silicotitanate (CST). This material has been produced as an engineered form (generally spherical beads) by Honeywell UOP LLC (Des Plaines, IL). Previous forms of this media have been tested in a wide array of simulants and process scales, but column breakthrough and batch contact testing to date on actual tank waste has been limited to a few tank wastes. Washington River Protection Solutions requested a series of studies to demonstrate Cs load behavior in a small column format and determine if a simple batch contact test with CST can be used to qualify tank waste supernate prior to processing it in the LAWPS. The goal of the batch contact testing is to determine if there are any issues with the tank waste that would preclude Cs removal by the ion exchanger. Testing was conducted with IONSIV TM R9140-B CST provided by Honeywell UOP in 2018 (Batch 2081000057). The CST was received in the sodium (Na) form, so no pretreatment conditioning to convert to the Na form was required. Before use in testing, the CST was passed through a #25 sieve (710-micron openings) and collected on a #60 sieve (250-micron openings) with the intent of removing any large and fine particles. Physical properties were measured on the CST including particle size distribution (d50 = 570 microns) and scanning electron micrographic examination. The CST was rinsed with water until the contact solution was visually nearly clear. The CST bed density (1.00 g/mL) and CST bed void fraction (0.656) were measured on the sieved and rinsed CST. The batch contact testing varied Cs concentration in a 5.6 M Na simple simulant solution. Testing was conducted in a liquid volume to solids mass ratio of 200. The distribution coefficient (K d ) was determined to be 770 mL/g at the Cs equilibrium condition of 8.0 μg/mL; with a bed density of 1.00 g/mL, this corresponds to a predicted 50% Cs breakthrough of 770 bed volumes (BVs). The Cs load capacity at 8.0 μg/mL equilibrium condition was determined to be 6.16 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, albeit on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column. Three flowrates were tested: 1.19, 1.99, and 4.56 BV/h. The feed was displaced with 0.1 M NaOH, and then the columns were rinsed with water sequentially through the lead then lag columns. One column system was evaluated top to bottom with a gamma scanner to assess the axial Cs loading. Table ES.1 summarizes the relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Flue Gas Purification and Latent Heat Recovery for Pressurized Oxy-Combustion (Final Scientific/Technical Report)

Pressurized oxy-combustion has been identified by DOE as a transformational technology for coal power with carbon capture due to the advantages that are realized when the combustion process is pressurized. The staged pressurized oxy-combustion (SPOC) process is particularly attractive as the efficiency of the process is almost 6 percentage points greater than that of first generation oxy-combustion. A critical component of the SPOC process, and potentially other pressurized combustion processes, is the Direct Contact Cooler (DCC) where the latent heat of the flue gas moisture is recovery to improve plant efficiency while simultaneously removing SO x and NO x from the flue gas, so that the FGD and de-NO x processes can be eliminated, and the cost of electricity minimized. The objective of this R&D effort was to advance the TRL of the DCC technology, which included performance testing at a 100 kW scale to validate the process and obtain key engineering data for scale-up. A collateral objective was to study the gas- and liquid-phase kinetics, and the development of a systematic chemical mechanism validated by experimental data. Experiments in a bench-scale stirred reactor provided an updated understanding of the liquid chemistry and the effects of temperature and pH. This information was used to develop a reduced reaction mechanism, which was subsequently incorporated in an ASPENbased process model, to allow for evaluation of the DCC at full scale. A small-pilot DCC column was designed, constructed and tested using simulated flue gas at the pressurized oxy-combustion test facility at Washington University in St. Louis. In the majority of tests, the SO 2 capture approached 100%, making the NO x capture the primary metric of capture efficiency. An NO x capture efficiency of 90% was achieved when the gas residence time was 95 seconds, demonstrating that high capture rates can be attained with reasonable reactor size. At higher temperatures (up to 200°C inlet gas temperature) the total NO x scrubbing efficiency was reduced by approximately 10% (compared to room temp.) and this was attributed to a reduced NO oxidation rate. A significant amount of SO 2 was present in the gas outlet (10%) only when the temperature was high and the N:S ratio was low (N/S < 1), which highlights the necessity of controlling the NOx concentration in the flue gas for complete sulfur scrubbing. After incorporated our optimized chemical mechanism into an ASPEN process model, various full-scale configurations of the DCC were evaluate, and the results indicate that the proposed DCC can accomplish its intended goals at full scale and at a modest size. Thus, the results of this project indicate that the DCC is a promising technology for recovery of the latent heat of the moisture in the flue gas while simultaneously scrubbing the nitrogen and sulfur oxides, thus enabling pressurized oxy-combustion, in general, and the SPOC process, in particular.

01 COAL, LIGNITE, AND PEAT↗

Multifamily Building Stock Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-17-00701

U.S. multifamily buildings house 35 million households, consuming 4 quads of source energy and spending $48 billion on utility bills every year. Almost all of these households live in urban areas, where cities are taking the lead on setting aggressive energy goals. Cities currently do not have the data and tools necessary to identify and target opportunities to save energy in their building stock. Building on the open-source, OpenStudio-based ResStock platform, this project will extend the publicly-available ResStock modeling capabilities to the multifamily sector, enabling Radiant Labs, and others, to partner with cities to market and strategically deploy cost-effective, energy efficiency (EE) upgrades directly to high-priority households. Radiant Labs has been successful in using ResStock's single-family capabilities to provide value to the City of Boulder, Colorado. However, lack of multifamily capabilities in ResStock is a roadblock for Radiant Labs working with New York City, San Francisco, Washington, D.C., and other cities that have expressed significant interest in working with them. In addition, other cities, companies, and utilities can use these open-source capabilities to grow their EE portfolios, thereby multiplying the impact of this project. This work also enables national-scale analysis of EE potential in multifamily buildings, which is of strong interest to a variety of stakeholders, including the U.S. Department of Energy (DOE) Office of Energy Policy and Systems Analysis (EPSA), DOE Weatherization Assistance Program (WAP), U.S. Department of Housing and Urban Development (HUD), and the Bonneville Power Administration (BPA).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Marine Sciences Laboratory Radionuclide Air Emissions

The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office has oversight and stewardship duties associated with the Pacific Northwest National Laboratory Marine Sciences Laboratory (MSL), located on Battelle Land-Sequim. The facility has two buildings with the potential to emit low levels of radioactive materials. DOE-SC contracted for exclusive use of its radiological operations effective October 1, 2012. This report is prepared to document compliance with the Code of Federal Regulation, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants , Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code Chapter 246-247, Radiation Protection–Air Emissions . Compliance is indicated by comparing the estimated effective dose equivalent (EDE) to the maximally exposed individual (MEI) with the 10 millirem per year (mrem/yr) U.S. Environmental Protection Agency (EPA) standard. The MSL has only fugitive emissions sources. Despite the fact that the regulations are intended for application to point source emissions, fugitive emissions are included with regard to complying with the EPA standard. The EDE to the MSL MEI due to routine operations in 2016 was 5.7E-04 mrem (5.7E-06 mSv). No non-routine emissions occurred in 2016. The MSL is in compliance with the federal and state 10 mrem/yr standard.

40 CFR 61 Subpart H↗

PNNL Richland Campus Radionuclide Air Emissions Report for Calendar Year 2016

This report documents radionuclide air emissions that result in the 2016 highest effective dose equivalent (EDE) to an offsite member of the public, referred to as the maximally exposed individual (MEI). The report has been prepared in compliance with the Code of Federal Regulations (CFR), Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAP), Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code (WAC) Chapter 246-247, “Radiation Protection–Air Emissions.” The dose to the PNNL Richland Campus MEI from routine major and minor point source emissions in 2016 from PNNL Richland Campus sources is 5.8E-4 mrem (5.8E-6 mSv) EDE. The dose from all fugitive sources is 1.9E-6 mrem (1.9E-8 mSv) EDE. The dose from radon emissions is 1.3E-8 mrem (1.3E-10 mSv) EDE. No nonroutine emissions occurred in 2016. The total radiological dose to the MEI from all PNNL Richland Campus radionuclide emissions, including fugitive emissions and radon, is 5.8E-4 mrem (5.8E-6 mSv) EDE, or more than 10,000 times less than the federal and state standard of 10 mrem/yr, with which the PNNL Richland Campus is in compliance.