Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Variability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Decision making for implementing non-traditional water sources: a review of challenges and potential solutions

Abstract The effects of climate change, population growth, and future hydrologic uncertainties necessitate increased water conservation, new water resources, and a shift towards sustainable urban water supply portfolios. Diversifying water portfolios with non-traditional water sources can play a key role. Rooftop harvested rainwater (RHRW), atmospheric and condensate harvesting, stormwater, recycled wastewater and greywater, and desalinated seawater and brackish water are all currently utilized and rapidly emerging non-traditional water sources. This review explores the status and trends around these non-traditional water sources, and reviews approaches and models for prioritizing, predicting, and quantifying metrics of concern. The analysis presented here suggests that understanding the challenges of location specific scenarios, socioeconomic knowledge gaps, water supply technologies, and/or water management structure is the crucial first step in establishing a model or framework approach to provide a strategy for improvement going forward. The findings of this study also suggest that clear policy guidance and onsite maintenance is necessary for variable water quality concerns of non-traditional sources like harvested rainwater and greywater. In addition, use of stormwater or reuse of wastewater raises public health concerns due to unknown risks and pathogen levels, thus rapid monitoring technologies and transparent reporting systems can facilitate their adoption. Finally, cost structure of desalination varies significantly around the world, largely due to regulatory requirements and local policies. Further reduction of its capital cost and energy consumption is identified as a hurdle for implementation. Overall, models and process analyses highlight the strength of comparative assessments across scenarios and water supply options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Entropy removal of medical diagnostics

Shannon entropy is a core concept in machine learning and information theory, particularly in decision tree modeling. To date, no studies have extensively and quantitatively applied Shannon entropy in a systematic way to quantify the entropy of clinical situations using diagnostic variables (true and false positives and negatives, respectively). Decision tree representations of medical decision-making tools can be generated using diagnostic variables found in literature and entropy removal can be calculated for these tools. This concept of clinical entropy removal has significant potential for further use to bring forth healthcare innovation, such as quantifying the impact of clinical guidelines and value of care and applications to Emergency Medicine scenarios where diagnostic accuracy in a limited time window is paramount. This analysis was done for 623 diagnostic tools and provided unique insights into their utility. For studies that provided detailed data on medical decision-making algorithms, bootstrapped datasets were generated from source data to perform comprehensive machine learning analysis on these algorithms and their constituent steps, which revealed a novel and thorough evaluation of medical diagnostic algorithms.

97 MATHEMATICS AND COMPUTING↗

An exploration of machine learning models for the determination of reaction coordinates associated with conformational transitions

Determining collective variables (CVs) for conformational transitions is crucial to understanding their dynamics and targeting them in enhanced sampling simulations. Often, CVs are proposed based on intuition or prior knowledge of a system. However, the problem of systematically determining a proper reaction coordinate (RC) for a specific process in terms of a set of putative CVs can be achieved using committor analysis (CA). Identifying essential degrees of freedom that govern such transitions using CA remains elusive because of the high dimensionality of the conformational space. Various schemes exist to leverage the power of machine learning (ML) to extract an RC from CA. Here, we extend these studies and compare the ability of 17 different ML schemes to identify accurate RCs associated with conformational transitions. We tested these methods on an alanine dipeptide in vacuum and on a sarcosine dipeptoid in an implicit solvent. Our comparison revealed that the light gradient boosting machine method outperforms other methods. In order to extract key features from the models, we employed Shapley Additive exPlanations analysis and compared its interpretation with the “feature importance” approach. For the alanine dipeptide, our methodology identifies ϕ and θ dihedrals as essential degrees of freedom in the C7ax to C7eq transition. For the sarcosine dipeptoid system, the dihedrals ψ and ω are the most important for the cisαD to transαD transition. We further argue that analysis of the full dynamical pathway, and not just endpoint states, is essential for identifying key degrees of freedom governing transitions.

Chemistry↗

Data from a throughfall exclusion experiment: Fine root dynamics, morphology, chemistry, and AMF colonization across four lowland Panamanian forests

Fine roots regulate forest nutrient, carbon, and water cycling, yet their variation within and among tropical forests remains under-characterized. We quantified root productivity, disappearance, and stocks to 1 m using minirhizotron imaging, and we measured morphology, elemental composition [root carbon (C), root nitrogen (N), root phosphorus (P)], and arbuscular mycorrhizal fungi (AMF) colonization to 20 cm using ingrowth cores and sequential coring. Sampling took place in four distinct lowland Panamanian forests (32 plots; 8 per forest) from 2018 through 2022 under control and throughfall-exclusion (drought) treatments in the Panama Rainforest Changes with Experimental Drying (PARCHED) experiment.The dataset is presented as an Excel workbook with six tabs. The first tab is the data dictionary. Tab S1 contains ingrowth-core production and mortality, morphology and soil moisture. Tab S2 contains sequential-coring standing stocks with associated morphology and soil moisture. Tab S3 contains minirhizotron row data records to 1 m depth, including per-frame root length and diameter, normalized length metrics, and session timing. Tab S4 contains AMF colonization. Tab S5 contains fine-root chemistry at 0–10 cm, reporting %P, %C, %N, and C:N for samples collected via ingrowth cores and sequential-coring standing stocks. CSV mirrors for each tab are provided, and a KML file supplies coordinates for all 32 plots.Key variables span live and dead fine-root biomass (and coarse fractions where applicable), specific root length (SRL) and area (SRA), diameter, root tissue density (RTD), soil moisture, AMF colonization, root %N, %C, %P, and C:N, along with minirhizotron root length and diameter. Depth, season, treatment, and plot/site identifiers are included to support cross-tab integration and analysis from 0–100 cm (minirhizotron) and 0–20 cm (cores).Units are reported in-column and missing values are coded as NA. No special software is required to open or use the files (Excel, CSV, and KML compatible).

54 ENVIRONMENTAL SCIENCES↗

Data and scripts associated with a manuscript analyzing ELM-FATES parameter sensitivity under pre-fire and postfire scenarios using machine learning

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “Fire Severity-Dependent Shifts in Vegetation Parameter Sensitivity: A Pre- and Post-Fire Analysis Using ELM-FATES and Explainable AI” submitted to Journal of Advances in Modeling Earth Systems (Zahura et al. 2026). The study examines vegetation physiological parameters controlling pre-fire and post-fire vegetation dynamics. To support this analysis, 73 vegetation parameters in Functionally Assembled Terrestrial Ecosystem Simulator (FATES) (Fisher et al., 2018) , which is coupled with E3SM (Energy Exascale Earth System Model) land model (ELM, ELM-FATES), were perturbed using a Sobol sequence to generate 1,024 ensemble members for two plant functional types: needleleaf evergreen extratropical trees (NEET) and C3 grass. Simulations were conducted for the pre-fire period (2016) and post-fire period (2018–2023). Burn severity was represented by modifying the Nesterov index in FATES to 75,000, 150,000, and 300,000 for low, moderate, and high severity, respectively. A no-fire scenario was also included. Simulations were performed for 16 grid cells in the American River Watershed across different burn severities and plant functional types. XGBoost (eXtreme Gradient Boosting) models were trained using the parameter ensembles and ELM-FATES-simulated outputs, including leaf area index (LAI), gross primary productivity (GPP), aboveground biomass, vegetation evaporation, transpiration, and soil evaporation. Models were trained separately for each year and burn severity, followed by SHAP (SHapley Additive exPlanations) analysis to identify changes in dominant parameters after fire disturbance. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. The data package contains the ELM-FATES simulation data. The scripts and data related to the analysis will be added later. The inputs and outputs from ELM-FATES are inside the “FATES” folder. “FATES_domain_surface” contains the domain and surface netcdfs that were used to run ELM-FATES in the study area. “FATES_parameters” contains the 1024 ensembles that were generated using Sobol sequence. “FATES_outputs” folder contains ELM-FATES simulated variables. All files are .csv and .nc (NetCDF).

Aboveground biomass↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B×B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincar´e map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. These action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 µrad. Utilizing the BPMs’ B×B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

43 PARTICLE ACCELERATORS↗

Challenges and Opportunities for Electric Utility Modeling and Asset Valuation Frameworks: Case Study on Valuing New Pumped Storage Hydropower

Asset valuation by electric utilities is becoming increasingly difficult in the rapidly changing electric sector. Rapid deployment of variable generation and inverter-based storage systems along with uncertain demand growth, climate, policies, and other factors create a challenging environment for understanding the value proposition of a new potential asset. This report describes an effort between the Tennessee Valley Authority (TVA) and three U.S. Department of Energy laboratories to perform a detailed review of utility modeling and analysis practices for asset valuation and identify challenges and opportunities for advancing its methods into the future. It focuses on a case study of new potential pumped storage hydropower (PSH) because of growing interest in new PSH capacity to provide energy balancing, firm capacity, and a range of ancillary services. Staff from the DOE labs conducted systematic interviews about current practices in capacity expansion modeling, production-cost modeling, hydrological modeling, and transmission stability modeling while also discussing how scenario analysis is conducted and how models and data are integrated. The effort resulted in a set of model, integration, and scenario recommendations that could be valuable to TVA, other utilities, system operators, and other stakeholders conducting integrated grid analysis. Individual model recommendations suggest exploring computational tradeoffs with detail and resolution across spatiotemporal structure, supply- and demand-side details, transmission overlays, market interactions, and ancillary services. Automated processes to pass data between models and conduct larger scenario suites could also enhance valuation practices by enabling a more consistent study of asset value across a broader range of uncertain future grid conditions where PSH could be particularly valuable. TVA and other industry stakeholders can learn from and adapt applied research-grade methods developed by DOE laboratories and other research institutions to improve decision making and accelerate progress towards a reliable, economic, sustainable energy system.

13 HYDRO ENERGY↗

An Analysis of the Spatial Variations in the Relationship Between Built Environment and Severe Crashes

Traffic crashes significantly contribute to global fatalities, particularly in urban areas, highlighting the need to evaluate the relationship between urban environments and traffic safety. This study extends former spatial modeling frameworks by drawing paths between global models, including spatial lag (SLM), and spatial error (SEM), and local models, including geographically weighted regression (GWR), multi-scale geographically weighted regression (MGWR), and multi-scale geographically weighted regression with spatially lagged dependent variable (MGWRL). Utilizing the proposed framework, this study analyzes severe traffic crashes in relation to urban built environments using various spatial regression models within Leon County, Florida. According to the results, SLM outperforms OLS, SEM, and GWR models. Local models with lagged dependent variables outperform both the global and generic versions of the local models in all performance measures, whereas MGWR and MGWRL outperform GWR and GWRL. Local models performed better than global models, showing spatial non-stationarity; so, the relationship between the dependent and independent variables varies over space. The better performance of models with lagged dependent variables signifies that the spatial distribution of severe crashes is correlated. Finally, the better performance of multi-scale local models than classical local models indicates varying influences of independent variables with different bandwidths. According to the MGWRL model, census block groups close to the urban area with higher population, higher education level, and lower car ownership rates have lower crash rates. On the contrary, motor vehicle percentage for commuting is found to have a negative association with severe crash rate, which suggests the locality of the mentioned associations.

Alisan, Onur (ORCID:0000000193113984)↗

Regression models using shapes of functions as predictors

Functional variables are often used as predictors in regression problems. A commonly used parametric approach, called scalar-on-function regression, uses the $\mathbb L^2$ inner product to map functional predictors into scalar responses. This method can perform poorly when predictor functions contain undesired phase variability, causing phases to have disproportionately large influence on the response variable. One past solution has been to perform phase–amplitude separation (as a pre-processing step) and then use only the amplitudes in the regression model. In this paper, we propose a more integrated approach, termed elastic functional regression model (EFRM), where phase-separation is performed inside the regression model, rather than as a pre-processing step. This approach generalizes the notion of phase in functional data, and is based on the norm-preserving time warping of predictors. Due to its invariance properties, this representation provides robustness to predictor phase variability and results in improved predictions of the response variable over traditional models. We demonstrate this framework using a number of datasets involving gait signals, NMR data, and stock market prices.

97 MATHEMATICS AND COMPUTING↗

Tank Closure Cesium Removal Ion Exchange Column CST Characterization: SRNL-STI-2024-00072 (Rev.0) pdf

Savannah River Mission Completion (SRMC) recently suspended operation of the Tank Closure Cesium Removal (TCCR) system which utilized an ion exchange (IX) process to remove radioactive cesium from waste supernate. During the demonstration phase, a total of three batches of Tank 10H dissolved salt waste were processed through the original TCCR columns. Subsequently, dissolved salt waste from Tank 9H was processed through TCCR in a phase referred to as TCCR 1A with four new IX columns. All eight columns have now been moved to Interim Safe Storage (ISS). For each batch processed through the TCCR IX columns, SRNL performed a number of analyses on surface and variable depth samples as well as batch equilibrium contact tests (BECT) to determine equilibrium loadings of Cs on the crystalline silicotitanate (CST) IX media. The BECTs were performed by lowering “teabags” containing ~0.1 g of CST each into the tank for a period of at least 10 days. The teabags were then retrieved and sent to SRNL for digestion and analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessing complexity and dynamics in epidemics: geographical barriers and facilitators of foot-and-mouth disease dissemination

Introduction: Physical and non-physical processes that occur in nature may influence biological processes, such as dissemination of infectious diseases. However, such processes may be hard to detect when they are complex systems. Because complexity is a dynamic and non-linear interaction among numerous elements and structural levels in which specific effects are not necessarily linked to any one specific element, cause-effect connections are rarely or poorly observed. Methods: To test this hypothesis, the complex and dynamic properties of geo-biological data were explored with high-resolution epidemiological data collected in the 2001 Uruguayan foot-and-mouth disease (FMD) epizootic that mainly affected cattle. County-level data on cases, farm density, road density, river density, and the ratio of road (or river) length/county perimeter were analyzed with an open-ended procedure that identified geographical clustering in the first 11 epidemic weeks. Two questions were asked: (i) do geo-referenced epidemiologic data display complex properties? and (ii) can such properties facilitate or prevent disease dissemination? Results: Emergent patterns were detected when complex data structures were analyzed, which were not observed when variables were assessed individually. Complex properties–including data circularity–were demonstrated. The emergent patterns helped identify 11 counties as ‘disseminators’ or ‘facilitators’ (F) and 264 counties as ‘barriers’ (B) of epidemic spread. In the early epidemic phase, F and B counties differed in terms of road density and FMD case density. Focusing on non-biological, geographical data, a second analysis indicated that complex relationships may identify B-like counties even before epidemics occur. Discussion: Geographical barriers and/or promoters of disease dispersal may precede the introduction of emerging pathogens. If corroborated, the analysis of geo-referenced complexity may support anticipatory epidemiological policies.

60 APPLIED LIFE SCIENCES↗

An efficient hybrid downscaling framework to estimate high-resolution river hydrodynamics

Flow depth and velocity are the most important hydrodynamic variables that govern various river functions, including water resources, navigation, sediment transport, and biogeochemical cycling. Existing high-resolution flow depth simulations rely on either computationally expensive river hydrodynamic models (RHMs) or data-driven models with formidable training costs, whereas data-driven modeling of flow velocity has rarely been explored. Here, using the hybrid Low-fidelity, Spatial analysis, and Gaussian process learning (LSG) model, we developed a downscaling approach to construct high-resolution flow depth and velocity from a two-dimensional (2-D) RHM simulation at coarse resolution. The LSG models were trained and tested in an urban watershed in Houston using two different hurricane-driven flood events. The high-resolution (as fine as 30 m resolution) and low-resolution (mostly 1000 m resolution) meshes include 664 724 and 14 536 grid cells, respectively. The results showed that through downscaling, the simulation errors were reduced to less than one-fourth and one-third of the errors of the low-resolution 2-D RHM for flow depth and velocity, respectively. Our analysis further revealed that the dominant uncertainty sources of the downscaled hydrodynamics are different, with flow velocity dominated by the dimensionality reduction error, which we reduced by using a regionalized training procedure. The downscaling approach achieves an 84-fold acceleration in computational time compared to the high-resolution 2-D RHM, making high-fidelity ensemble flood modeling feasible. More importantly, the developed method provides an opportunity to couple large-scale hydrodynamical processes with local physical, chemical, and biological processes in river models.

Tan, Zeli [Pacific Northwest National Laboratory (↗

Synthesizing, Compounding, and Characterizing a Heat Labile Polyurethane Foam

ABSTRACT A need exists for a packaging foam material that can be converted from solid to gaseous degradation products at reasonably low energy levels or temperatures, such as 100O C. This paper will primarily discuss the approaches currently being used to synthesize and characterize such a material. These approaches include the incorporation of novel polyols such as azo containing diols, polycarbonate diols, and polypropylene carbonate polyols into polyurethane foams. Characterization methods include NMR, FTIR, TGA, finite element analysis, impact strength, and others. This project will be funded for a duration of three years. Year 1 focused on developing the proposed test methods and producing an initial rigid polyurethane foam. Year 2 focuses on refining the materials and test methods. If appropriate, design of experiment (doe) techniques will be used to optimize components, component levels, density and other variables to attain required final material properties (TGA weight loss, impact strength, etc.). Year 3 focuses on scaling up to larger engineering quantities. The application for this material is in load securement for transportation of low level radioactive waste materials within the US Department of Energy (DOE) complex. Foam in place process equipment and operators will be shielded using this novel method over current practice. Current practice can involve time consuming methods of load securement in low level radiation environments. This new technique would eliminate exposure time securing the load and greatly improve the As Low As Reasonably Attainable (ALARA) conditions. The objective is to progress to higher Technical Readiness Levels (TRL) and larger pilot scale quantities. This paper discusses methodologies and presents current results to date.

Kranjc, Mark D.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-time biomass feedstock particle quality detection using image analysis and machine vision

Abstract A common and costly challenge in the nascent biorefinery industry is the consistent handling and conveyance of biomass feedstock materials, which can vary widely in their chemical, physical, and mechanical properties. Solutions to cope with varying feedstock qualities will be required, including advanced process controls to adjust equipment and reject feedstocks that do not meet a quality standard. In this work, we present and evaluate methods to autonomously assess corn stover feedstock quality in real time and provide data to process controls with low-cost camera hardware. We explore the use of neural networks to classify feedstocks based on actual processing behavior and pixel matrix feature parameterization to further assess particle attributes that may explain the variable processing behavior. We used the pretrained ResNet neural network coupled with a gated recurrent unit (GRU) time-series classifier trained on our image data, resulting in binary classification of feedstock anomalies with favorable performance. The textural aspects of the image data were statistically analyzed to determine if the textural features were predictive of operational disruptions. The significant textural features were angular second moment, prominence, mean height of surface profile, mean resultant vector, shade, skewness, variation of the polar facet orientation, and direction of azimuthal facets. Expansion of these models is recommended across a wider variety of labeled feedstock images of different qualities and species to develop a more robust tool that may be deployed using low-cost cameras within biorefineries.

09 BIOMASS FUELS↗

Analysis of hydrogen infrastructure for the feasibility, economics, and sustainability of a fuel cell powered data center

Data centers used for internet data services, cloud computing, and/or data storage consume vast amounts of electricity and are increasing rapidly in capacity. Consequently, their power consumption has raised concerns about energy sustainability and environmental impacts. Large-scale, on-site renewable energy could help reduce data centers’ carbon footprint; however, wind and solar power alone cannot provide an uninterrupted power supply to computer servers due to their natural variability. Instead, reliable power integration can be achieved by using fuel cells powered by hydrogen from sustainable resources (e.g., wind and solar energy). Establishing a hydrogen infrastructure will be critical for realizing these benefits and establishing fuel cells as a viable power source for data centers. Here, to facilitate the development of novel carbon-free fuel cell data enters, this paper presents renewable power integrated with hydrogen infrastructures in four scenarios to provide reliable hydrogen supply from production to storage. Various paths were analyzed toward a hydrogen supply infrastructure by determining the proper component sizes and calculating the cost of meeting the server load. We used a microgrid modeling software, Hybrid Optimization of Multiple Energy Resources (HOMER), and studied the feasibility of fuel cell powered data centers employing renewable hydrogen. The modeling results show various renewable integration configurations to meet reliable and sustainable power requirement under four scenarios for a carbon-free data center.

08 HYDROGEN↗