Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Validation Studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

Application of Extended Kalman Filter Techniques for Dynamic Model Parameter Calibration

Abstract -Phasor measurement has previously been used for sub-system model validation, which enables rigorous comparison of model simulation and recorded dynamics and facilitates identification of problematic model components. Recent work extends the sub-system model validation approach with a focus on how model parameters may be calibrated to match recorded dynamics. In this paper, a calibration method using Extended Kalman Filter (EKF) technique is proposed. This paper presents the formulation as well as case studies to show the validity of the EKF-based parameter calibration method. The proposed calibration method is expected to be a cost-effective means complementary to traditional equipment testing for improving dynamic model quality.

Extended Kalman Filter↗

SU-D-19A-04: Parameter Characterization of Electron Beam Monte Carlo Phase Space of TrueBeam Linacs

Purpose: For TrueBeam Monte Carlo simulations, Varian does not distribute linac head geometry and material compositions, instead providing a phase space file (PSF) for the users. The PSF has a finite number of particle histories and can have very large file size, yet still contains inherent statistical noises. The purpose of this study is to characterize the electron beam PSF with parameters. Methods: The PSF is a snapshot of all particles' information at a given plane above jaws including type, energy, position, and directions. This study utilized a preliminary TrueBeam PSF, of which validation against measurement is presented in another study. To characterize the PSF, distributions of energy, position, and direction of all particles are analyzed as piece-wise parameterized functions of radius and polar angle. Subsequently, a pseudo PSF was generated based on this characterization. Validation was assessed by directly comparing the true and pseudo PSFs, and by using both PSFs in the down-stream MC simulations (BEAMnrc/DOSXYZnrc) and comparing dose distributions for 3 applicators at 15 MeV. Statistical uncertainty of 4% was limited by the number of histories in the original PSF. Percent depth dose (PDD) and orthogonal (PRF) profiles at various depths were evaluated. Results: Preliminary results showed that this PSF parameterization was accurate, with no visible differences between original and pseudo PSFs except at the edge (6 cm off axis), which did not impact dose distributions in phantom. PDD differences were within 1 mm for R{sub 7} {sub 0}, R{sub 5} {sub 0}, R{sub 3} {sub 0}, and R{sub 1} {sub 0}, and PRF field size and penumbras were within 2 mm. Conclusion: A PSF can be successfully characterized by distributions for energy, position, and direction as parameterized functions of radius and polar angles; this facilitates generating sufficient particles at any statistical precision. Analyses for all other electron energies are under way and results will be included in the presentation.

07 ISOTOPE AND RADIATION SOURCES↗

Study of MPLNET-Derived Aerosol Climatology over Kanpur, India, and Validation of CALIPSO Level 2 Version 3 Backscatter and Extinction Products

The level 2 aerosol backscatter and extinction profiles from the NASA Micropulse Lidar Network (MPLNET) at Kanpur, India, have been studied from May 2009 to September 2010. Monthly averaged extinction profiles from MPLNET shows high extinction values near the surface during October March. Higher extinction values at altitudes of 24 km are observed from April to June, a period marked by frequent dust episodes. Version 3 level 2 Cloud Aerosol Lidar with Orthogonal Polarization (CALIOP) aerosol profile products have been compared with corresponding data from MPLNET over Kanpur for the above-mentioned period. Out of the available backscatter profiles, the16 profiles used in this study have time differences less than 3 h and distances less than 130 km. Among these profiles, four cases show good comparison above 400 m with R2 greater than 0.7. Comparison with AERONET data shows that the aerosol type is properly identified by the CALIOP algorithm. Cloud contamination is a possible source of error in the remaining cases of poor comparison. Another source of error is the improper backscatter-to-extinction ratio, which further affects the accuracy of extinction coefficient retrieval.

extinction profiles↗

Performance and wake flow characterization of a 1:8.7-scale reference USDOE MHKF1 hydrokinetic turbine to establish a verification and validation test database

As hydrokinetic turbine technologies continue to advance towards commercialization, public datasets on the performance characteristics for these devices and their flow field effects are invaluable to advance our understanding of these technologies and to validate analytical and numerical models. The Applied Research Laboratory at The Pennsylvania State University (ARL Penn State) collaborated with Sandia National Laboratories and the University of California at Davis to design, fabricate (at a 1:8.7 scale), and experimentally test a novel hydrokinetic turbine rotor design to provide an open platform and dataset for further study and development. The water tunnel test of this three-bladed, horizontal-axis rotor recorded power production, blade loading, the near-wake flow, cavitation effects, and noise generation. These state-of-the-art measurements demonstrate much of the complex physics associated with the flow through an unducted, horizontal-axis turbine, and they elucidate the performance characteristics and flow field effects at an unprecedented fidelity, accuracy and resolution. Measurements of powering coefficients (power, torque and thrust) as a function of tip-speed-ratio were performed. The dataset also includes unsteady measurements of driveshaft loading, blade strain, tower pressures, and radiated noise. Detailed flow mapping using laser Doppler velocimetry, and planar and stereo particle image velocimetry includes measurements of mean velocity and Reynolds stresses. Although the wake measurements are limited to less than half a diameter, they reveal the complex flow patterns in the near-wake structure of the rotor. The full database, available at the United States Department of Energy’s marine and hydrokinetic data repository, includes tunnel and model Computer Aided Design geometry files and inflow data sufficient for a “Model-the-Test” computational Verification and Validation study.

13 HYDRO ENERGY↗

Assessment of a hybrid finite element and finite volume code for turbulent incompressible flows

Hydra-TH is a hybrid finite-element/finite-volume incompressible/low-Mach flow simulation code based on the Hydra multiphysics toolkit being developed and used for thermal-hydraulics applications. In the present work, a suite of verification and validation (V&V) test problems for Hydra-TH was defined to meet the design requirements of the Consortium for Advanced Simulation of Light Water Reactors (CASL). The intent for this test problem suite is to provide baseline comparison data that demonstrates the performance of the Hydra-TH solution methods. The simulation problems vary in complexity from laminar to turbulent flows. A set of RANS and LES turbulence models were used in the simulation of four classical test problems. Numerical results obtained by Hydra-TH agreed well with either the available analytical solution or experimental data, indicating the verified and validated implementation of these turbulence models in Hydra-TH. Where possible, some form of solution verification has been attempted to identify sensitivities in the solution methods, and suggest best practices when using the Hydra-TH code. -- Highlights: •We performed a comprehensive study to verify and validate the turbulence models in Hydra-TH. •Hydra-TH delivers 2nd-order grid convergence for the incompressible Navier–Stokes equations. •Hydra-TH can accurately simulate the laminar boundary layers. •Hydra-TH can accurately simulate the turbulent boundary layers with RANS turbulence models. •Hydra-TH delivers high-fidelity LES capability for simulating turbulent flows in confined space.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electron Cloud Simulations for the Electron-Ion Collider in Brookhaven National Laboratory

For high-intensity circular accelerators and storage rings, if the secondary electron emission yield (SEY) of the vacuum chamber surfaces is high, an EC (Electron Cloud) could build up with the passage of the circulating beam. The presence of EC can strongly affect the beam quality, such as transverse instabilities, transverse emittance growth, and beam loss. Furthermore, the heat load from EC can exceed the available cryogenic capability. For the RHIC superconducting (SC) arc magnets, to be used for the hadron storage ring of the Electron-Ion Collider (EIC), the dynamic heat load budget is 0.5 W/m to the 4.5 K stainless steel beam pipe. This can limit the maximum beam bunches or intensity of the EIC, hence diminishing the luminosity provided by the EIC. The EC has affected the beam instability and significantly contributed to cryogenic heat load in the Large Hadron Collider (LHC). Positron storage rings for which ECs have been a critical factor in the design and performance include KEKB in Japan and EC buildup remains one of the concerns for future high-intensity accelerators design. EC considerations have driven the SuperKEKB collider design and the positron damping ring for the proposed International Linear Collider (ILC). The LHC luminosity upgrade is contingent on reducing the bunch spacing to 25 ns; at this bunch spacing, severe EC buildup has been observed. The success of the upgrade is likely contingent on limiting EC buildup. To study the EC heat load, we did some EC simulations with PyECLOUD code for the dipole, quadrupole, sextupole magnets, and the warm (drift) section of the EIC hadron storage ring. PyECLOUD is an EC simulation code developed by CERN. The code has been validated and used to study EC in the LHC, SPS, and PS. To eliminate EC buildup, the sources of electrons must be minimized. First, we will reduce the production of electrons due to residual gas ionization by specifying the maximum gas density, which requires a vacuum chamber with low electron-stimulated desorption (ESD) yields and a sufficient (preferably distributed) pumping speed. Second, we should reduce the secondary electrons with a lower secondary electron yield (SEY) material.

43 PARTICLE ACCELERATORS↗

Experimental Evaluation of Verification and Validation Tools on Martian Rover Software

We report on a study to determine the maturity of different verification and validation technologies (V&V) on a representative example of NASA flight software. The study consisted of a controlled experiment where three technologies (static analysis, runtime analysis and model checking) were compared to traditional testing with respect to their ability to find seeded errors in a prototype Mars Rover. What makes this study unique is that it is the first (to the best of our knowledge) to do a controlled experiment to compare formal methods based tools to testing on a realistic industrial-size example where the emphasis was on collecting as much data on the performance of the tools and the participants as possible. The paper includes a description of the Rover code that was analyzed, the tools used as well as a detailed description of the experimental setup and the results. Due to the complexity of setting up the experiment, our results can not be generalized, but we believe it can still serve as a valuable point of reference for future studies of this kind. It did confirm the belief we had that advanced tools can outperform testing when trying to locate concurrency errors. Furthermore the results of the experiment inspired a novel framework for testing the next generation of the Rover.

Brat, Guillaume↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of VOC Fenceline Sensors and Canister Grab Sampling near Chemical Facilities in Louisville, Kentucky

Experimental fenceline sensor pods (SPods) fitted with 30 s duration canister grab sampling (CGS) systems were deployed at a site near chemical facilities in Louisville, KY, from 4 June 2018 to 5 January 2020. The objective of the study was to better understand lower cost 10.6 eV photoionization detector (PID)-based volatile organic compound (VOC) sensors and investigate their utility for near-source emissions detection applications. Prototype SPods containing PID sensor elements from two different manufacturers yielded between 78% and 86% valid data over the study, producing a dataset of over 120,000 collocated pair fenceline measurements averaged into 5-min datapoints. Ten-second time-resolved SPod data from an elevated fenceline sensor signal day are presented, illustrating source emission detections from the direction of a facility 500 m west of the monitoring site. An SPod-triggered CGS acquired in the emission plume on this day contained elevated concentrations of 1,3-butadiene and cyclohexane (36 parts per billion by volume (ppbv) and 637 ppbv, respectively), compounds known to be emitted by this facility. Elevated concentrations of these compounds were observed in a subset of the 61 manual and triggered CGS grab samples acquired during the study, with winds from the west. Using novel wind-resolved visualization and normalization approaches described herein, the collocated pair SPod datasets exhibited similarity in emission source signature. With winds from the west, approximately 50% of SPod readings were above our defined theoretical detection limit indicating persistent measurable VOC signal at this site. Overall, this 19-month study demonstrated reasonable prototype SPod operational performance indicating that improved commercial forms of lower cost PID sensors could be useful for select VOC fenceline monitoring applications.

1,3-butadiene↗

Validation of picogram- and femtogram-input DNA libraries for microscale metagenomics

High-throughput sequencing libraries are typically limited by the requirement for nanograms to micrograms of input DNA. This bottleneck impedes the microscale analysis of ecosystems and the exploration of low biomass samples. Current methods for amplifying environmental DNA to bypass this bottleneck introduce considerable bias into metagenomic profiles. For this study, we describe and validate a simple modification of the Illumina Nextera XT DNA library preparation kit which allows creation of shotgun libraries from sub-nanogram amounts of input DNA. Community composition was reproducible down to 100 fg of input DNA based on analysis of a mock community comprising 54 phylogenetically diverse Bacteria and Archaea. The main technical issues with the low input libraries were a greater potential for contamination, limited DNA complexity which has a direct effect on assembly and binning, and an associated higher percentage of read duplicates. We recommend a lower limit of 1 pg (~100–1,000 microbial cells) to ensure community composition fidelity, and the inclusion of negative controls to identify reagent-specific contaminants. Applying the approach to marine surface water, pronounced differences were observed between bacterial community profiles of microliter volume samples, which we attribute to biological variation. This result is consistent with expected microscale patchiness in marine communities. We thus envision that our benchmarked, slightly modified low input DNA protocol will be beneficial for microscale and low biomass metagenomics.

100 fg↗

Validation of MODIS 3 km Land Aerosol Optical Depth from NASA's EOS Terra and Aqua Missions

In addition to the standard resolution product (10km), the MODerate resolution Imaging Spectroradiometer (MODIS) Collection 6 (C006) data release included a higher resolution (3km). Other than accommodations for the two different resolutions, the 10 and 3km Dark Target (DT) algorithms are basically the same. In this study, we perform global validation of the higher-resolution aerosol optical depth (AOD) over global land by comparing against AErosol RObotic NETwork (AERONET) measurements. The MODIS-AERONET collocated data sets consist of 161410 high-confidence AOD pairs from 2000 to 2015 for Terra MODIS and 2003 to 2015 for Aqua MODIS. We find that 62.5 and 68.4% of AODs retrieved from Terra MODIS and Aqua MODIS, respectively, fall within previously published expected error bounds of +/-(0.05+0.2 × AOD), with a high correlation (R = 0.87). The scatter is not random, but exhibits a mean positive bias of ∼ 0.06 for Terra and ∼ 0.03 for Aqua. These biases for the 3km product are approximately 0.03 larger than the biases found in similar validations of the 10km product. The validation results for the 3km product did not have a relationship to aerosol loading (i.e., true AOD), but did exhibit dependence on quality flags, region, viewing geometry, and aerosol spatial variability. Time series of global MODIS-AERONET differences show that validation is not static, but has changed over the course of both sensors' lifetimes, with Terra MODIS showing more change over time. The likely cause of the change of validation over time is sensor degradation, but changes in the distribution of AERONET stations and differences in the global aerosol system itself could be contributing to the temporal variability of validation.

Gupta, Pawan↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

LIDAR Wind Speed Measurements of Evolving Wind Fields

Light Detection and Ranging (LIDAR) systems are able to measure the speed of incoming wind before it interacts with a wind turbine rotor. These preview wind measurements can be used in feedforward control systems that are designed to reduce turbine loads. However, the degree to which such preview-based control techniques can reduce loads by reacting to turbulence depends on how accurately the incoming wind field can be measured. Past studies have assumed the validity of physicist G.I. Taylor’s 1938 frozen turbulence hypothesis, which implies that turbulence remains unchanged as it advects downwind at the mean wind speed. With Taylor’s hypothesis applied, the only source of wind speed measurement error is distortion caused by the LIDAR. This study introduces wind evolution, characterized by the longitudinal coherence of the wind, to LIDAR measurement simulations using the National Renewable Energy Laboratory’s (NREL’s) 5-megawatt turbine model to create a more realistic measurement model. A simple model of wind evolution was applied to a frozen wind field that was used in previous studies to investigate the effects of varying the intensity of wind evolution. LIDAR measurements were also evaluated using a large eddy simulation (LES) of a stable boundary layer that was provided by the National Center for Atmospheric Research.

17 WIND ENERGY↗

Status update of the BWR cask simulator

The performance of commercial nuclear spent fuel dry storage casks are typically evaluated through detailed numerical analysis of the system's thermal performance. These modeling efforts are performed by the vendor to demonstrate the performance and regulatory compliance and are independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Numerous studies have been previously conducted. Recent advances in dry storage cask designs have moved the storage location from above ground to below ground and significantly increased the maximum thermal load allowed in a cask in part by increasing the canister helium pressure. Previous cask performance validation testing did not capture these parameters. The purpose of the investigation described in this report is to produce a data set that can be used to test the validity of the assumptions associated with the calculations presently used to determine steady-state cladding temperatures in modern dry casks. These modern cask designs utilize elevated helium pressure in the sealed canister or are intended for subsurface storage. The BWR cask simulator (BCS) has been designed in detail for both the above ground and below ground venting configurations. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure (MAWP) rating of 24 bar at 400 C. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly is being deployed inside of a representative storage basket and cylindrical pressure vessel that represents the canister. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. Various configurations of outer concentric ducting will be used to mimic conditions for above and below ground storage configurations of vertical, dry cask systems with canisters. Radial and axial temperature profiles will be measured for a wide range of decay power and helium cask pressures. Of particular interest is the evaluation of the effect of increased helium pressure on heat load and the effect of simulated wind on a simplified below ground vent configuration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LIDAR Wind Speed Measurements of Evolving Wind Fields

Light Detection and Ranging (LIDAR) systems are able to measure the speed of incoming wind before it interacts with a wind turbine rotor. These preview wind measurements can be used in feedforward control systems that are designed to reduce turbine loads. However, the degree to which such preview-based control techniques can reduce loads by reacting to turbulence depends on how accurately the incoming wind field can be measured. Past studies have assumed the validity of physicist G.I. Taylor's 1938 frozen turbulence hypothesis, which implies that turbulence remains unchanged as it advects downwind at the mean wind speed. With Taylor's hypothesis applied, the only source of wind speed measurement error is distortion caused by the LIDAR. This study introduces wind evolution, characterized by the longitudinal coherence of the wind, to LIDAR measurement simulations using the National Renewable Energy Laboratory's (NREL's) 5-megawatt turbine model to create a more realistic measurement model. A simple model of wind evolution was applied to a frozen wind field that was used in previous studies to investigate the effects of varying the intensity of wind evolution. LIDAR measurements were also evaluated using a large eddy simulation (LES) of a stable boundary layer that was provided by the National Center for Atmospheric Research. The LIDAR measurement scenario investigated consists of a hub-mounted LIDAR that scans a circle of points upwind of the turbine in order to estimate the wind speed component in the mean wind direction. Different combinations of the preview distance that is located upwind of the rotor and the radius of the scan circle were analyzed. It was found that the dominant source of measurement error for short preview distances is the detection of transverse and vertical wind speeds from the line-of-sight LIDAR measurement. It was discovered in previous studies that, in the absence of wind evolution, the dominant source of error for large preview distances is the spatial averaging caused by the LIDAR's sampling volume. However, by introducing wind evolution, the dominant source of error for large preview distances was found to be the coherence loss caused by evolving turbulence. Different measurement geometries were compared using the bandwidth for which the measurement coherence remained above 0.5 and also the area under the measurement coherence curve. Results showed that, by increasing the intensity of wind evolution, the measurement coherence decreases. Using the coherence bandwidth metric, the optimal preview distance for a fixed-scan radius remained almost constant for low and moderate amounts of wind evolution. For the wind field with the simple wind evolution model introduced, the optimal preview distance for a scan radius of 75% blade span (47.25 meters) was found to be 80 meters. Using the LES wind field, the optimal preview distance was 65 meters. When comparing scan geometries using the area under the coherence curve, results showed that, as the intensity of wind evolution increases, the optimal preview distance decreases.

17 WIND ENERGY↗

The 2014 Sandia Verification and Validation Challenge: Problem statement

This paper presents a case study in utilizing information from experiments, models, and verification and validation (V&V) to support a decision. It consists of a simple system with data and models provided, plus a safety requirement to assess. The goal is to pose a problem that is flexible enough to allow challengers to demonstrate a variety of approaches, but constrained enough to focus attention on a theme. This was accomplished by providing a good deal of background information in addition to the data, models, and code, but directing the participants' activities with specific deliverables. In this challenge, the theme is how to gather and present evidence about the quality of model predictions, in order to support a decision. This case study formed the basis of the 2014 Sandia V&V Challenge Workshop and this resulting special edition of the ASME Journal of Verification, Validation, and Uncertainty Quantification.

42 ENGINEERING↗

Distribution Model Creation using Circuit Maps for Applied PV Impact Studies

Photovoltaic (PV) generation is becoming increasingly common on power distribution systems. The output fluctuations of this variable resource necessitate the creation of an accurate model to ensure that any adverse impacts to the distribution system are properly addressed. To reduce model creation time, a method of extracting data from AutoCAD drawings using scripted methods was developed. This paper will present a distribution model creation and validation process, document case studies of evaluating the impact of PV interconnections on utility distribution feeders, and discuss future applications. PV integration was found to be easier on 23 kV circuits compared to 4.16 kV circuits.

integrated circuit modeling↗