Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transversity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Temperature dependence of viscoelastic Poisson’s ratio of cement mortar

Abstract Concrete creep research has focused primarily on uniaxial response. However, biaxially prestressed concrete structures are common, resulting in a multiaxial stress state that can complicate the behavior of a viscoelastic material like concrete. Significant creep strains may be induced in directions transverse to each principle stress due to Poisson’s effect. Past research is unclear regarding the viscoelastic or viscoplastic properties of concrete outside of uniaxial response. It has been reported in separate studies that concrete viscoelastic/viscoplastic Poisson’s ratio (VPR) is an increasing, decreasing and constant function with time, with all reported measurements performed at room temperature. In this paper, the 3D basic creep response of mature cement mortar is examined using a confined compression experiment that allows direct determination of the full stress and infinitesimal strain tensors in a single test, which enables the determination of VPR under a multiaxial stress state. For this purpose, a unique, miniature version of the standardized concrete creep frame is designed that is amenable to placing in climate chambers and temperature ovens. The experimental results indicate that the VPR of sealed, mature cement mortar is nearly constant and equal to the elastic at room temperature, while the VPR gradually increases with time when measured at 60 °C.

Construction & Building Technology↗

Data for: Ultrasonic characterization of material heterogeneities in stainless steel parts fabricated by powder bed fusion

These are the raw ultrasonic waveform files and nanoindentation measurements for three additively manufactured 316L stainless steel components with different fabrication parameters. Each part's length is divided into four segmented regions where their fabrication energy densities change. Part V+ begins at 33 J/mm^3 and increases in energy density by 3 J/mm^3 with each segment. Part C remains at a constant 33 J/mm^3 throughout the part. Part V- begins at 33 J/mm^3 and decreases in energy density by 3 J/mm^3 with each segment. We have found that the ultrasonic waves in regions with higher energy densities will traverse more quickly, as shown by the shorter time of flight, and vice versa. Similarly, nanoindentation measurements of reduced modulus and hardness follow this trend. We have measured the direction in which the parts were fabricated (build direction) and the segmented regions that are perpendicular to the build direction (transverse directions). The build direction longitudinal wave velocity measurements are considerably lower than their transverse direction counterparts, indicating anisotropy between the two directions. In Part C, we have removed material from one of its surfaces and recorded its ultrasonic and nanoindentation measurements with each material removal iteration. Changes in the material properties are more prominent by nanoindentation, suggesting material heterogeneity between the part's surface and interior. The README.txt file has information on how to navigate the files and process the data.

Anisotropy↗

Direct Observations of Sub-micropulse Electron-beam Effects from Short-range Wakefields in TESLA-type Superconducting RF Cavities

The preservation of the low emittance of electron beams during transport in the accelerating structures of large facilities is an ongoing challenge. In the cases of the TESLA-type superconducting rf cavities currently used in the European X-ray Free-electron Laser (FEL) and the under construction Linac Coherent Light Source upgrade (LCLS-II), off-axis beam transport may result in emittance dilution due to transverse long-range and short-range wakefields (SRW)*. To investigate such effects, experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility with its unique two-cavity configuration after the photocathode rf gun. We used optical transition radiation (OTR) imaging with a UV-visible synchroscan streak camera to display sub-micropulse y-t effects in the 41-MeV beam. The head-tail transverse kicks within the 11-ps-long micropulses were observed at the 100-micron level for steering off-axis in one cavity and several 100 microns for two cavities. Since the SRW kick angles go inversely with energy, these results may inform the commissioning plans of the LCLS-II injector where beam will be injected at ~1 MeV into a cryomodule.

43 PARTICLE ACCELERATORS↗

Design of an RF-Dipole Crabbing Cavity System for the Electron-Ion Collider

The Electron-Ion Collider requires several crabbing systems to facilitate head-on collisions between electron and proton beams in increasing the luminosity at the interaction point. One of the critical rf systems is the 197 MHz crabbing system that will be used in crabbing the proton beam. Many factors such as the low operating frequency, large transverse voltage requirement, tight longitudinal and transverse impedance thresholds, and limited beam line space makes the crabbing cavity design challenging. The rf-dipole cavity design is considered as one of the crabbing cavity options for the 197 MHz crabbing system. The cavity is designed including the HOM couplers, FPC and other ancillaries. This paper presents the detailed electromagnetic design, mechanical analysis, and conceptual cryomodule design of the crabbing system.

De Silva, S. U.↗

Superconducting RF Gun with High Current and the Capability to Generate Polarized Electron Beams

High-current low-emittance CW electron beams are indispensable for nuclear and high-energy physics fixed target and collider experiments, cooling high energy hadron beams, generating CW beams of monoenergetic X-rays (in FELs) and gamma-rays (in Compton sources). Polarization of electrons in these beams provides extra value by opening a new set of observables and frequently improving the data quality. We report on the upgrade of the unique and fully functional CW SRF 1.25 MeV SRF gun, built as part of the Coherent electron Cooling (CeC) project, which has demonstrated sustained CW operation with CsK2Sb photocathodes generating electron bunches with record-low transverse emittances and record-high bunch charge exceeding 10 nC. We propose to extend the capabilities of this system to high average current of 100 milliampere in two steps: increasing the current 30-fold at each step with the goal to demonstrate reliable long-term operation of the high-current low-emittance CW SRF guns. We also propose to test polarized GaAs photocathodes in the ultra-high vacuum (UHV) environment of the SRF gun, which has never been successfully demonstrated in RF accelerators.

43 PARTICLE ACCELERATORS↗

Modeling of the Optical Stochastic Cooling at the IOTA Storage Ring Using ELEGANT

In support of the Optical Stochastic Cooling (OSC) experiment at IOTA, we implemented a high-fidelity model of OSC in ELEGANT. The element is generalizable to any OSC experiment and captures three main behaviors; (i) the longitudinal time of flight OSC, (ii) the effects between the transverse motion of particles in the beam and the transverse distribution of undulator radiation, and (iii) the incoherent contributions of neighboring particles. Together these produce a highly accurate model of OSC and were benchmarked using the results from the IOTA OSC experiment.

43 PARTICLE ACCELERATORS↗

Modeling of standing wave RF cavities for tracking through multi-pass energy recovery linac

Short bunches, high current and multiple linac pass are all characteristics of Energy Recovery Linacs (ERLs), which may result in collective effects. They in turn, may affect the beam, degrading its quality, or even yield to instabilities causing a beam loss. To study and mitigate these effects one needs a numerical simulation code, that can take into account both the collective effects, as well as, particular ERL features, such as a multi-turn design that does not reach a steady state or the multiple passages of the beam through Radio-Frequency (RF) cavities at different energies. CODAL [1], a code developed by SOLEIL in collaboration with IJCLab, enables such studies. It is a 6 dimensional (6D) tracking code applying 'kicks' based on the integration of the local Hamiltonian for each element of the lattice. It is also capable of simulating space charge, wakefields and coherent synchrotron radiation. However, to correctly take into account the ERL dynamics, an upgrade had to be made to include the effect of a standing wave RF cavity in 6D. In this paper, we will concentrate on the implementation and benchmarking (with DESY’s tracking code ASTRA [2]) of both the longitudinal and the transverse models (by J.B. Rosenzweig and L. Serafini [3]), which we use to carry out tracking of fully analytical 6D RF cavity.

Bogacz, A.↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗

Beam Performance of the Positron Transport Line for CEBAF Positron Upgrade

The Low Energy Recirculator Facility (LERF) at Jefferson Lab, formerly operated for the Free-Electron Laser program, has been proposed as the injector complex for the planned 12 GeV CEBAF positron upgrade (Ce+BAF), with an additional pathway to support a potential 22 GeV CEBAF electron upgrade. In this configuration, LERF would generate and pre-accelerate positrons to 123 MeV, matching the present injection energy into the North Linac. Due to the relatively large emittance expected from the positron source, a comprehensive acceptance study has been performed from LERF through the CEBAF recirculating linacs and beam transport lines to the experimental halls. The objective is to establish the positron phase-space acceptance and provide design feedback to the positron production and capture systems. Furthermore, given CEBAF’s capability to deliver highly polarized beams, spin-tracking simulations have been carried out including magnet imperfections, alignment errors, and synchrotron-radiation–induced energy spread. Particular attention is given to the evolution of the spin tune and the corresponding depolarization mechanisms along the beam delivery path, especially for providing longitudinal polarization at the experimental halls. These results inform injector design choices and assess the overall feasibility of delivering high-polarization positron beams in CEBAF.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Benchmarking the Use of BPM Quadrupole Moments to Measure Emittance

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer transverse emittance. By compositing many BPMs together, it becomes possible to improve the quality of the quadrupole signal. The Fermilab Booster BPM system has been used to measure these quadrupole moments in the past year and derive emittances from them. Recent benchmarks show that the derived BPM emittances show similar emittance evolution and value to IPM and Multiwire data. This approach can both supplement and complement existing non-intercepting emittance monitors in accelerators.

Balcewicz, M. A. [Fermilab]↗

Simulations of positron injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130‑370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The simulation results for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are presented, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, <1 mm bunch length and normalized emittance of <100 mm mrad). The impact of target thickness, drive electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated.

Accelerator Physics↗

Measurements of the beam longitudinal properties in the Fermilab Linac

The Fermilab Linac delivers 400$\,$MeV, 25$\,$mA H$^-$ beam to a rapid cycling synchrotron called the Booster. Parameters of the Linac beam affect Booster performance and therefore quantifying them is important. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the phase of an upstream cavity and fitted to simulations. The cavity gradient and its phase with respect to the beam are recovered from readings of Beam Position Monitors. Since the cavity provides a significant transverse defocusing, the BSM measurements are correlated with transverse beam size measurements by a wire scanner. Simulations connect these three types of measurements, allowing to deduce the longitudinal emittance and Courant-Snyder parameters.

Sharankova, Ralitsa [Fermilab] (ORCID:000000027014↗

One-to-one mapping between the electromagnetic modes of cylindrical and coaxial half-wave cavities

Design of radio frequency (RF) couplers and diagnostics require a good understanding of the electromagnetic mode patterns of RF cavities. This study investigates the adiabatic transformation of transverse magnetic (TM) modes in a cylindrical cavity into transverse electromagnetic (TEM) modes of a coaxial cavity by gradually introducing an inner conductor. Using CST Studio Suite, we simulate the eigenmode evolution as the geometry transforms from a pure cylindrical to a coaxial configuration. We track the behavior of TM010 through TM014 modes to observe the continuous evolution into the corresponding TEM0 through TEM4 modes of the coaxial cavity. The process is governed by the evolution of the electric field orientation as the geometry shifts, enabling the axial TM fields to reorient into the radial electric field configuration of TEM modes. Field patterns, eigen-frequencies, and mode indentities are analyzed throughtout the transition. The results provide simulation-based evidence that TM to TEM conversion occurs without generation of newer eigenmodes, offering a valuable insight into the design of transition regions in superconducting RF (SRF) systems and provides a foundation for experimental validation.

Accelerator Physics↗

Laser Plasma Interaction in the MG Magnetic Field (Final Report)

Strong magnetic fields change properties of plasma. Employment of the magnetic fields can improve conditions for inertial confinement fusion. Compression and heating of the magnetized plasma is a base of the MagLIF pulsed power approach to the controlled fusion. Study of expansion and heating of plasma in the external magnetic fields, development of plasma instabilities, parametric and other effects are important for basic physics and applications. The main goal of the research for the grant was experimental investigation of laser produced plasma in the well characterized and controlled MG magnetic fields. We developed a platform for investigation of high intensity laser-plasma interaction (LPI) in the MG fields using a university-scale pulsed power machine. A Zebra machine at UNR generated transverse magnetic fields of 3 MG on the surface of the rod load and longitudinal fields of 1.4 MG in the coil loads. The magnetic fields were characterized with two-color Faraday rotation diagnostics. The pulsed power machine provided almost static magnetic fields for LPI compared to the much faster laser driven magnetic fields. We found that eddy currents in the rising magnetic field generate plasma on the metal targets. Eddy currents did not impact Si and CH dielectric targets. A Leopard laser with intensity in the focus up to 10 19 W/cm 2 produced plasma in the MG magnetic fields. The modified reflected Faraday diagnostics was used to study laser driven B-field at the MTW laser at Laboratory for Laser Energetics, UR. We demonstrated a slow dependence of the magnetic field in the coil on the applied laser intensity. The magnetic field increased by a factor of 2 if laser intensity increased by a factor of 30. This scaling is important for comparison of experiments at different laser facilities. Expansion of the plasma in the 2-3 MG external B-field was studied. Laser-produced plasma in the azimuthal magnetic field took the unique form of a thin disc expanding radially with a velocity of 250 km/s and confined in the vertical direction. A HYDRA MHD program at the University of Rochester was applied for simulations of LPI in the magnetic field B >3 MG. Simulations for the plasma disc parameters and the expansion dynamics were in a good agreement with experiments. Generation of narrow dense plasma jets in the longitudinal magnetic field of 0.6-0.8 MG was studied. Narrow plasma jets reached a length of 3-4 mm with the electron plasma density of (0.2-1.2)x10 20 cm -3 . A jet tip propagated with the velocity of 160-200 km/s. MHD simulations showed a good agreement of the dynamics of the formation of plasma jets with experiments. These jets are relevant to astrophysical jets. Simulations of K-shell spectra of Si plasma was performed for LPI in the B-field. The laser prepulse generated plasma near the laser target. A PrismSPECT model with a MeV electron beam produced by the laser was used. The spectral modelling showed the increased plasma density by a factor by 2-3 in the magnetic field. This was in agreement with the observed dynamics of the plasma plume confined by the axial magnetic field. The two-plasmon decay was studied in the 2.5-3 MG transversal magnetic fields. Strong 2-3.5 nm spectral widening and a 2-4 nm shifts of “red” and “blue” 3/2ω 0 spectral components were observed. The large shift and widening exceed the expected temperature and magnetic shift. PIC simulations are performing to clarify physics of this effect. The experimental research program for the grant is completed. New plasma effects in the MG fields were studied at the university-scale pulsed power generator. Two graduate and two undergraduate UNR and UR students carried experiments at the Zebra generator, supported and developed plasma diagnostics, provided data processing, and performed MHD simulations of LPI in the strong magnetic field. Research results are published in 9 referred papers and presented in 12 conferences. Program manager: Kramer U. Akli; Collaborators: R. C. Mancini and H. Sawada, University of Nevada, Reno (UNR); R. Betti and A. V. Maximov, University of Rochester (UR).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Room Temperature Quasi-static Characterization and Constitutive Model Parametrization of Flexible Polyurethane Foams of Different Densities Loaded in Different Orientations

This report describes the efforts to characterize and model General Plastics TF6070 and EF4000 flexible polyurethane foams under room temperature, large deformation quasi-static cyclic mechanical loading conditions. Densities from three to fifteen pound per cubic foot (PCF) are examined, which correspond to relative densities of approximately 4 to 20%. These foams are open cell structured and flexible at room temperature with a glass transition transition less than -30°C, and they fully recover their original shape when unloaded (at room temperature). Uniaxial compression tests were conducted with accompanying lateral image series for Digital Image Correlation (DIC) analysis with the goal of extracting transverse strain responses. Due to difficulties with DIC analysis at large strains, lateral strains were instead extracted for each test via edge tracking. The experimental results exhibit a nonlinear elastic response and anisotropic material behavior (particularly for the lower densities). Some hysteresis is observed that is different between the first and subsequent cycles of deformation indicating both a small degree of permanent damage (reduced stiffness during reloading) and viscoelasticity. These inelastic mechanisms are not considered in the modeling and calibration in this report. This work considers only the rate independent, room temperature foam behavior. Individual foam densities were calibrated for loading in two directions, parallel and perpendicular to the foam bubble rise direction, since the mechanical behavior is different in these two directions. The Flex Foam constitutive model was used for all parameterizations despite the fact that the model is isotropic. A review of the constitutive model is given as well as necessary data reduction procedures to parameterize it for each foam density and orientation are discussed. Finally, two different parameterizations are developed that take the undeformed foam density as an input that span all densities considered. These two parameterized models represent foams loaded in the rise and transverse directions respectively. We summarize the assumptions and limitations of the parameterizations provided in this report to guide analysis choices with them. All parameterizations presented herein have the following traits, room temperature, rate independent, damage-free, and non-dissipative . Isotropy (even if they are representing anisotropic data). Supplied Sierra Solid Mechanics Flex Foam Model Inputs are in units: pounds, inches, Celsius, and seconds

36 MATERIALS SCIENCE↗

Space charge fields in azimuthally symmetric beams: Integrated Green's function approach

Electromagnetic fields induced by the space charge in relativistic beams play an important role in Accelerator Physics. They lead to emittance growth, slice energy change, and the microbunching instability. Typically, these effects are modeled numerically since simple description exists only inthe limits of large- or small-scale current variations. In this paper we consider an axially symmetric charged beam inside a round pipe and find the solution of the space charge problem that is valid in the full range of current variations. We express the solution for the field components in terms of Green’s functions, which are fully determined by just a single function. We then find that this function is an on-axis potential from a charged disk in a round pipe, with transverse charge density ρ⊥(r), and it has a compact analythical expression. We finally provide an integrated Green’s function based approach for efficient numerical evaluation in the case when the transverse charge density stays the same along the beam

43 PARTICLE ACCELERATORS↗