Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Bad River Band of Lake Superior Chippewa Indians Solar Project

The Bad River Band of Lake Superior Chippewa (the Tribe) implemented its first phase of energy independence through the installation of approximately 520 kW DC of solar photovoltaic (PV) at three tribal buildings: 200kW DC at the Wastewater Treatment Plant (WWTP), 300 kW DC at the Health & Wellness Center (Health Clinic), and 20 kW AC at the Chief Blackbird Administration Building (Administration Building). The solar PV systems were integrated with the existing utility grid and can operate independent of the grid using Battery Energy Storage Systems (BESS) in combination with solar and existing back-up gas generators. The BESS also creates resiliency, providing power when the grid is down. All three buildings are essential Tribal buildings.

14 SOLAR ENERGY↗

Dynamic analysis of a photovoltaic power system with battery storage capability

A photovolataic power system with a battery storage capability is analyzed. A dual battery current control concept is proposed, which enables the battery to either supply or accept power depending upon system environment and load conditions. A simulation of the power system, including the battery current control, is developed and evaluated. The evaulation demonstrate the visbility of the battery control concept of switch the battery from a charge to discharge mode and back as required by load and environmental conditions. An acceptable system operation is demonstrated over the entire insolation range. Additionally, system sensitivity, bandwidth, and damping characteristics of the battery control are shown to be acceptable for a projected hardware implementation.

Merrill, W. C.↗

Exergy Analysis of Solar Still with Sand Heat Energy Storage

This paper studies the experimental and exergy analysis of solar still with the sand heat energy storage system. The cumulative yield from solar still with and without energy storage material is found to be 3.3 and 1.89 kg/m{sup 2}, respectively for 8-h operation. Results show that the exergy efficiency of the system is higher with the least water depth of 0.02 m (m{sub w} = 20 kg). Competitive analysis of second law efficiency shows that the exergy efficiency improves the system by 30% than conventional single slope solar still without any heat storage. The maximum exergy efficiency with energy storage material is found as 13.2% and it is less than the conventional solar still without any material inside the basin.

14 SOLAR ENERGY↗

Hydrogen Storage Engineering Center of Excellence Metal Hydride Final Report

The Hydrogen Storage Engineering Center of Excellence (HSECoE) was established in 2009 by the U.S. Department of Energy (DOE) to advance the development of materials-based hydrogen storage systems for hydrogen-fueled light-duty vehicles. The overall objective of the HSECoE is to develop complete, integrated system concepts that utilize reversible metal hydrides, adsorbents, and chemical hydrogen storage materials through the use of advanced engineering concepts and designs that can simultaneously meet or exceed all the DOE targets. This report describes the activities and accomplishments during Phase 1 of the reversible metal hydride portion of the HSECoE, which lasted 30 months from February 2009 to August 2011. A complete list of all the HSECoE partners can be found later in this report but for the reversible metal hydride portion of the HSECoE work the major contributing organizations to this effort were the United Technology Research Center (UTRC), General Motors (GM), Pacific Northwest National Laboratory (PNNL), the National Renewable Energy Laboratory (NREL) and the Savannah River National Laboratory (SRNL). Specific individuals from these and other institutions that supported this effort and the writing of this report are included in the list of contributors and in the acknowledgement sections of this report. The efforts of the HSECoE are organized into three phases each approximately 2 years in duration. In Phase I, comprehensive system engineering analyses and assessments were made of the three classes of storage media that included development of system level transport and thermal models of alternative conceptual storage configurations to permit detailed comparisons against the DOE performance targets for light-duty vehicles. Phase 1 tasks also included identification and technical justifications for candidate storage media and configurations that should be capable of reaching or exceeding the DOE targets. Phase 2 involved bench-level testing and evaluation of system configurations, including material packaging and balance-of-plant components, and conceptual design validation. Phase 3 includes fabrication and testing of the selected prototype storage system(s) for model validation and performance evaluation against the DOE targets. A DOE decision was needed for the HSECoE to advance to each phase and work on some classes of storage materials were recommended not to continue.

08 HYDROGEN↗

The Role of Energy Storage in Commercial Building

Motivation and Background of Study This project was motivated by the need to understand the full value of energy storage (thermal and electric energy storage) in commercial buildings, the opportunity of benefits for building operations and the potential interactions between a building and a smart grid infrastructure. On-site or local energy storage systems are not new to the commercial building sector; they have been in place in US buildings for decades. Most building-scale storage technologies are based on thermal or electrochemical storage mechanisms. Energy storage technologies are not designed to conserve energy, and losses associated with energy conversion are inevitable. Instead, storage provides flexibility to manage load in a building or to balance load and generation in the power grid. From the building owner's perspective, storage enables load shifting to optimize energy costs while maintaining comfort. From a grid operations perspective, building storage at scale could provide additional flexibility to grid operators in managing the generation variability from intermittent renewable energy resources (wind and solar). To characterize the set of benefits, technical opportunities and challenges, and potential economic values of storage in a commercial building from both the building operation's and the grid operation's view-points is the key point of this project. The research effort was initiated in early 2010 involving Argonne National Laboratory (ANL), the National Renewable Energy Laboratory (NREL), and Pacific Northwest National Laboratory (PNNL) to quantify these opportunities from a commercial buildings perspective. This report summarizes the early discussions, literature reviews, stakeholder engagements, and initial results of analyses related to the overall role of energy storage in commercial buildings. Beyond the summary of roughly eight months of effort by the laboratories, the report attempts to substantiate the importance of active DOE/BTP R&D activities in this space.

14 SOLAR ENERGY↗

ARIES/Flatirons Facility - Hydrogen System Capability Buildout

Under the "Advanced Research on Integrated Energy Systems" (ARIES) initiative, hydrogen system capabilities including a MW-scale electrolyzer, storage system, and MW-scale fuel cell generator will be designed and commissioned at NREL's Flatirons Campus. This hydrogen infrastructure will support H2@Scale goals by enabling integrated systems R&D to study the science of scaling for hydrogen energy systems.The system is designed with flexibility to provide a testbed to demonstrate systems integration, grid services, energy storage, direct renewable hydrogen production, and innovative end use applications (e.g. HD transportation, natural gas blending, etc.).

Advanced Research on Integrated Energy Systems↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

Automatic and Transparent Resource Contention Mitigation for Improving Large-Scale Parallel File System Performance

Proportional to the scale increases in HPC systems, many scientific applications are becoming increasingly data intensive, and parallel I/O has become one of the dominant factors impacting the large-scale HPC application performance. On a typical large-scale HPC system, we have observed that the lack of a global workload coordination coupled with the shared nature of storage systems cause load imbalance and resource contention over the end-to-end I/O paths resulting in severe performance degradation. I/O load imbalance on HPC systems is generally a self-inflicted wound and mostly occurs between the I/O paths and resources consumed by each individual job. In this paper, we introduce TAPP-IO, a dynamic, shared load balancing framework for mitigating resource contention. TAPP-IO extends our previous work and solves two major limitations: First, it transparently intercepts file creation calls during runtime to balance the workload over all available storage targets. The usage of TAPP-IO requires no application source code modifications and is independent from any I/O middleware. The framework can be applied to almost any HPC platform and is suitable for systems that lack a centralized file system resource manager. Second, the framework proposes a new placement strategy to support not only file-per-process I/O, but also single shared file I/O. This opens the door to a new class of scientific applications that can leverage the placement library for improved performance. We demonstrate the effectiveness of our integration on the Titan system at the Oak Ridge National Laboratory. Our experiments with a synthetic benchmark and real-world HPC workload show that, even in a noisy production environment, TAPP-IO can improve large-scale application performance significantly.

Neuwirth, Sarah↗

PCM-Based Durable Write Cache for Fast Disk I/O

Flash based solid-state devices (FSSDs) have been adopted within the memory hierarchy to improve the performance of hard disk drive (HDD) based storage system. However, with the fast development of storage-class memories, new storage technologies with better performance and higher write endurance than FSSDs are emerging, e.g., phase-change memory (PCM). Understanding how to leverage these state-of-the-art storage technologies for modern computing systems is important to solve challenging data intensive computing problems. In this paper, we propose to leverage PCM for a hybrid PCM-HDD storage architecture. We identify the limitations of traditional LRU caching algorithms for PCM-based caches, and develop a novel hash-based write caching scheme called HALO to improve random write performance of hard disks. To address the limited durability of PCM devices and solve the degraded spatial locality in traditional wear-leveling techniques, we further propose novel PCM management algorithms that provide effective wear-leveling while maximizing access parallelism. We have evaluated this PCM-based hybrid storage architecture using applications with a diverse set of I/O access patterns. Our experimental results demonstrate that the HALO caching scheme leads to an average reduction of 36.8% in execution time compared to the LRU caching scheme, and that the SFC wear leveling extends the lifetime of PCM by a factor of 21.6.

99 GENERAL AND MISCELLANEOUS↗

The development of a solar powered residential heating and cooling system

A solar energy collector design is disclosed that would be efficient for both energy transfer and fluid flow, based upon extensive parametric analyses. Thermal design requirements are generated for the energy storage systems which utilizes sensible heat storage in water. Properly size system components (including the collector and storage) and a practical, efficient total system configuration are determined by means of computer simulation of system performance.

Oneill, M. J.↗

Distribution Systems Planning and Analysis Framework for Indian Feeders - Partnership with BSES/BRPL

Integration of distributed energy resources (DER) such as photovoltaics, electric vehicles (EVs) and battery energy storage systems (BESS) is expected to rapidly increase in distribution systems in India. These grid edge resources can have adverse impacts on the grid and can provide additional revenue streams as well. To mitigate these impacts distribution planning and analysis is required. So this paper presents a framework which can be used to complete all steps involved in distribution planning and analysis. This framework uses data in the same format as is readily available with Indian utilities and processes it to generate detailed feeder models and loading profiles. This framework already includes multiple DER use cases such as peak shaving for BESS and EV demand modelling and can be easily extended to simulate a number of additional use cases. All of these use cases can be simulated in parallel for multi-year time series simulations using an integrated command line interface. A suit of grid readiness metrics are then evaluated for each simulation to determine required network upgrades and associated costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applicability of HBU Fuel Cask R and D Project to Al Clad Fuel Storage - 18558

Aluminum clad spent nuclear fuel (SNF) not destined to be reprocessed at Savannah River's H Canyon will eventually be moved from existing wet and dry storage facilities into standardized dry storage systems (e.g., Universal Canisters), ideally suited for disposal. With the current lack of disposal capacity in the U.S., placement of this SNF into dry storage requires plans for demonstrating to the regulator the safety of both the extended storage and the subsequent transportation to a future disposal facility of this SNF. For commercial SNF, concerns related to extended dry storage and subsequent transportation have been, and continue to be, addressed through several demonstration projects including, but not limited to, one for the lower burnup SNF at Idaho National Laboratory (INL) and one for the higher burnup SNF at Dominion's North Anna Power Station. Lessons learned from the more recent Orano led higher burnup demonstration project (HBU Demo Project) provides relevant information for advancing the concept of a 'smart cask' system for dry interim storage, which will allow for collection of data to support the safety demonstration for extended dry storage and subsequent transportation of the aluminum clad SNF. This 'smart cask' would eliminate the need for multiple demonstration projects that may have to be performed for different types of aluminum clad SNF designs and/or for potentially age distinguishing parameters, such as burnup or initial enrichment. This 'smart cask' would be developed and deployed by leveraging the HBU Demo Project's experience associated with modifying and deploying a TN-32B bolted carbon steel vertical storage cask system to monitor key parameters related to the criticality, structural, confinement, and thermal safety of the SNF and the canister system containing this SNF. This paper will focus on how the extensive design, licensing, and fabrication experience accumulated by the HBU Demo Project's cask system can be leveraged to support the design, licensing, and fabrication of a 'smart cask' system intended to support/confirm the interim dry storage, potential extended storage, and subsequent transportation of aluminum clad SNF, such as the Advanced Test Reactor (ATR) SNF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DART: distributed adaptive radix tree for efficient affix-based keyword search on HPC systems

© 2018 Association for Computing Machinery. Affix-based search is a fundamental functionality for storage systems. It allows users to find desired datasets, where attributes of a dataset match an affix. While building inverted index to facilitate efficient affix based keyword search is a common practice for standalone databases and for desktop file systems, building local indexes or adopting indexing techniques used in a standalone data store is insufficient for highperformance computing (HPC) systems due to the massive amount of data and distributed nature of the storage devices within a system. In this paper, we propose Distributed Adaptive Radix Tree (DART), to address the challenge of distributed affix-based keyword search on HPC systems. This trie-based approach is scalable in achieving efficient affix-based search and alleviating imbalanced keyword distribution and excessive requests on keywords at scale. Our evaluation at different scales shows that, comparing with the "full string hashing" use case of the most popular distributed indexing technique - Distributed Hash Table (DHT), DART achieves up to 55× better throughput with prefix search and with suffix search, while achieving comparable throughput with exact and infix searches. Also, comparing to the "initial hashing" use case of DHT, DART maintains a balanced keyword distribution on distributed nodes and alleviates excessive query workload against popular keywords.

Zhang, Wei↗

A Comparison of Flow-Through Versus Non-Flow-Through Proton Exchange Membrane Fuel Cell Systems for NASA's Exploration Missions

As part of the Exploration Technology Development Program (ETDP) under the auspices of the Exploration Systems Mission Directorate (ESMD), NASA is developing both primary fuel cell power systems and regenerative fuel cell (RFC) energy storage systems within the fuel cell portion of the Energy Storage Project. This effort is being led by the NASA Glenn Research Center (GRC) in partnership with the NASA Johnson Space Center (JSC), Jet Propulsion Laboratory (JPL), NASA Kennedy Space Center (KSC), and industrial partners. The development goals are to improve fuel cell and electrolysis stack electrical performance, reduce system mass, volume, and parasitic power requirements, and increase system life and reliability. A major focus of this effort has been the parallel development of both flow-through and non-flow-through proton exchange membrane (PEM) primary fuel cell power systems. The plan has been, at the appropriate time, to select a single primary fuel cell technology for eventual flight hardware development. Ideally, that appropriate time would occur after both technologies have achieved a technology readiness level (TRL) of six, which represents an engineering model fidelity PEM fuel cell system being successfully tested in a relevant environment. Budget constraints in fiscal year 2009 and beyond have prevented NASA from continuing to pursue the parallel development of both primary fuel cell options. Because very limited data exists for either system, a toplevel, qualitative assessment based on engineering judgement was performed expeditiously to provide guidance for a selection. At that time, the non-flow-through technology was selected for continued development because of potentially major advantages in terms of weight, volume, parasitic power, reliability, and life. This author believes that the advantages are significant enough, and the potential benefits great enough, to offset the higher state of technology readiness of flow-through technology. This paper summarizes the technical considerations which helped form the engineering judgement that led to the final decision.

Hoberecht, Mark A.↗

ARIES/Flatirons Facility - Hydrogen System Capability Buildout

Under the "Advanced Research on Integrated Energy Systems" (ARIES) initiative, hydrogen system capabilities including a MW-scale electrolyzer, storage system, and MW-scale fuel cell generator will be designed and commissioned at NREL's Flatirons Campus. This hydrogen infrastructure will support H2@Scale goals by enabling integrated systems R&D to study the science of scaling for hydrogen energy systems. The system is designed with flexibility to provide a testbed to demonstrate systems integration, grid services, energy storage, direct renewable hydrogen production, and innovative end use applications (e.g. HD transportation, natural gas blending, etc.).

DIRECT ENERGY CONVERSION,HYDROGEN↗

ARIES / Flatirons Facility - Hydrogen System Capability Buildout

Under the "Advanced Research on Integrated Energy Systems" (ARIES) initiative, hydrogen system capabilities including a MW-scale electrolyzer, storage system, and MW-scale fuel cell generator will be designed and commissioned at NREL's Flatirons Campus. This hydrogen infrastructure will support H2@Scale goals by enabling integrated systems R&D to study the science of scaling for hydrogen energy systems.The system is designed with flexibility to provide a testbed to demonstrate systems integration, grid services, energy storage, direct renewable hydrogen production, and innovative end use applications (e.g. HD transportation, natural gas blending, etc.).

electrical grid↗

Mechanical capacitor

A new energy storage system (the mechanical capacitor), using a spokeless magnetically levitated composite ring rotor, is described and design formulas for sizing the components are presented. This new system is configured around a permanent magnet (flux biased) suspension which has active servo control in the radial direction and passive control in the axial direction. The storage ring is used as a moving rotor and electronic commutation of the stationary armature coils is proposed. There is no mechanical contact with the rotating spokeless ring; therefore, long life and near zero rundown losses are projected. A 7-kW h system is sized to demonstrate feasibility. A literature review of flywheel energy storage systems is also presented and general formulas are developed for comparing rotor geometries.

Kirk, J. A.↗