Direct Measurement of Ammonia Storage on Passive SCR Systems for Lean Gasoline NOx Reduction Using Radio Frequency Sensing

Lean gasoline engine operation provides clear efficiency benefits relative to conventional stoichiometric combustion approaches. One of the key hurdles to the widespread, practical implementation of lean gasoline combustion remains the challenge of lean NOx control. One of the potential approaches for controlling NOx emission from lean gasoline engines is the so-called passive selective catalytic reduction (SCR) system. In such systems, periods of rich operation generate ammonia over a three-way catalyst (TWC), which is then adsorbed on the downstream SCR and consumed during lean operation. Brief periods of rich operation must occur in response to the depletion of stored ammonia on the SCR, which requires reliable measurements of the SCR ammonia inventory. Presently, lean exhaust system controls rely on a variety of gas sensors mounted up- and downstream of the catalysts, and which only provide an indirect inference of the operation state.In this study, a radio frequency (RF) sensor was used to provide a direction measurement of the amount of ammonia adsorbed on the SCR in real-time. The RF sensor was calibrated and deployed on a BMW N43B20 4-cylinder lean gasoline engine equipped with a passive SCR system. Brief periods of rich operation performed at lambda values between 0.98 and 0.99 generated the ammonia, subsequently stored on the SCR for consumption during periods of lean operation. The experiments compared real-time measurements of SCR ammonia inventory from the RF sensor with estimates of ammonia coverage derived from exhaust gas composition measurements upstream and downstream of the catalyst. The results showed a high degree of correlation between the RF measurements and SCR ammonia storage inventory, and demonstrated NOx conversion efficiencies above 98%, confirming the feasibility of the concept. Relative to stoichiometric operation, lean-gasoline operation resulted in fuel efficiency gains of up to 10%, which may be further improved through direct feedback control from the RF sensor to optimize lean–rich cycling based on actual, measured SCR ammonia levels.

Ragaller, Paul↗

Effects of head modeling errors on the spatial frequency representation of MEG

Abstract Objectives. We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM). Approach. A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.33 S m −1 was defined. The vertices were then randomly perturbed radially up to 2%, 4%, 6%, 8% and 10% of the radius. For each head perturbation case, the forward signal was calculated for dipolar sources located at 2 cm, 4 cm, 6 cm and 8 cm from the origin (center of the sphere), and for a 324 sensor array located at 10 cm to 15 cm from the origin. Equivalent current dipole (ECD) source localization was performed for each of these forward signals. The signal for each perturbed spherical head case was then analyzed in the spatial frequency domain, and the signal and ECD errors were quantified relative to the unperturbed case. Main results. In the noiseless and high signal-to-noise ratio (SNR) case of approximately ≥6 dB, inaccuracies in our spherical BEM head conductor models lead to increased signal and ECD inaccuracies when sensor arrays are placed closer to the head. This is true especially in the case of deep and superficial sources. In the noisy case however, the higher SNR for closer sensor arrays allows for an improved ECD fit and outweighs the effects of head geometry inaccuracies. Significance. OPMs may be placed directly on the head, as opposed to the more commonly used superconducting quantum interference device sensors which must be placed a few centimeters away from the head. OPMs thus allow for signals of higher spatial resolution to be captured, resulting in potentially more accurate source localizations. Our results suggest that an increased emphasis on accurate head modeling for OPMs may be necessary to fully realize its improved source localization potential.

Yeo, Wan-Jin (ORCID:0000000241417123)↗

Porous Membranes for Moisture Probe Protection (SR18024)

In the presence of contaminants, moisture probes can give false moisture readings and have shorter lifetimes. Absolute humidity probes are composed of porous, hygroscopic metallic oxide thin films (Al 2 O 3 ) coupled to electrodes (e.g. Au and Al). While these materials provide absolute humidity readings at low water levels at a relatively low cost, they are sensitive to the presence of contaminants, especially ammonia, due to its high hygroscopicity and ability to bind to the probe. Without frequent recalibration, especially in the presence of contaminants, the humidity levels are inaccurately reported due to measurement drift that occurs when the pores close, changing the impedance of the probe. The goal of this project was to improve the stability and reliability of these moisture probes by incorporating a molecular sieve into the probe to allow only the water to reach the sensor. Molecular sieves contain pores that allow molecule specific permeation. Two dimensional inorganic nanosheets (e.g. BN, MoO 2 , MoS 2 ) have recently been shown to behave as molecular sieves for water. Compared to zeolites, nanoporous materials have higher flux rates through the pores, leading to faster water permeation. Graphene oxide sheets have also been successfully employed for unimpeded water permeation; however, at lower humidity levels, the structure is unstable and the pores shrink, preventing the sieving of molecules. Compared to graphene oxide, sheets based off of inorganic materials, such as molybdenum, have been found to be more stable at lower humidity levels and have faster permeation rates. By creating a barrier in before the Al 2 O 3 sensor chip to prevent the permeation of contaminants into the probe, the lifetime of the probe will be extended. While the molybdenum sheets are a promising material for this application, their performance against ammonia and tritiated compounds have not yet been evaluated. This technology can be applied to other applications, including gas and liquid purification for environmental remediation, single molecule sensors, field effect transistors, and catalysts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Eddy Current Probe Parameters Identification Using a Genetic Algorithm and Simultaneous Perturbation Stochastic Approximation

This study tries to identify the coil parameters using numerical methods. The eddy current testing (ECT) is used for evaluation of a crack with the aid of numerical simulations by utilizing the identification of these parameters. In this study, a comparison of the performance of the GA and SPSA algorithms to identify the parameter values of the coil sensors are presented. So, the optimization probe geometry is introduced in the simulation with Three-dimensional finite element simulations (FLUX finite element code) were conducted to obtain eddy current signals resulting from a crack in a plate made of aluminium. The simulation results are compared with experimental measurements for the defect present in a plate.

42 ENGINEERING↗

Defect Characterization Through Automated Laser Track Trace Identification in SLM Processes Using Laser Profilometer Data

This paper presents recent developments in statistical image processing to demonstrate feasibility of layer-by-layer nondestructive inspection for selective laser melting (SLM) of metallic parts. A matrix of 10 mm × 10 mm stainless 316 squares was deposited with the first row consisting of just the sintered surface, Row 2 a single layer, Row 3 with 2 layers and so on. These layers were scanned to emulate the layer-by-layer collection of top surface geometry using a laser sensor. The resultant data were utilized to generate ISO 25718 roughness parameters and subsequently to perform track identification. This calculation consisted of two salient steps: (1) computing the gradients of surface roughness, which vanish at the peaks and pits, and (2) extracting the scanning direction by taking Hough transform of the geometry. This algorithm was repeated for all layers, and the alignment of the roughness with the rotating scan was observed to be persistent for all layers. Correlation between surface properties obtained along various scan directions and defect probability is explored.

36 MATERIALS SCIENCE↗

Super-porous Pt/CuO/Pt hybrid platform for ultra-sensitive and selective H 2 O 2 detection

A super-porous Pt/CuO/Pt hybrid electrode is demonstrated with extremely high sensing performance parameters for the hydrogen peroxide (H 2 O 2 ) detection. A unique physiochemical approach is adapted for the fabrication of 3-D super-porous Pt/CuO/Pt sensing platform. Here, the super-porous Pt/CuO/Pt hybrid platform demonstrates a superior sensitivity of 16,694 µA mM -1 cm -2 with a limit of detection of 2.91 nM (S/N = 3). It also demonstrates an excellent selectivity against the interfering molecules such as NaCl, fructose, ascorbic acid, citric acid, dopamine and glucose with a wide linear range. The demonstrated performance ranks the Pt/CuO/Pt hybrid platform as one of the best H 2 O 2 sensors as summarized in the Table 2. The super-porous CuO layer is fabricated by a dynamic hydrogen bubbling technique of electrochemical deposition and metallic Pt NP decoration is achieved by the physical vapor deposition (PVD) and post-annealing. The super-porous CuO layer offers a drastically improved electrochemical active surface area, and the Pt NP decoration offers a significantly improved conductivity and improved charge accumulation for the H 2 O 2 reduction. The DFT simulations confirm the predominance of CuO over Cu 2 O and Pt over Pd for the H 2 O 2 detection based on the adsorption energy, density of states and charge accumulation calculations.

36 MATERIALS SCIENCE↗

Solvent–Solvent Correlations across Graphene: The Effect of Image Charges

Wetting experiments show pure graphene to be weakly hydrophilic, but its contact angle (CA) also reflects the character of the supporting material. Measurements and Molecular Dynamics simulations on suspended and supported graphene often reveal a CA reduction due to the presence of the supporting substrate. A similar reduction is consistently observed when graphene is wetted from both sides. The effect has been attributed to transparency to molecular interactions across the graphene sheet, however, the possibility of substrate-induced graphene polarization has also been considered. Computer simulations of CA on graphene have so far been determined by ignoring the material’s conducting properties. We improve the graphene model by incorporating its conductivity according to the Constant Applied Potential Molecular Dynamics. Using this method, we compare the wettabilities of suspended graphene and graphene supported by water by measuring the CA of cylindrical water drops on the sheets. The inclusion of graphene conductivity and concomitant polarization effects lead to a lower CA on suspended graphene but the CA reduction is significantly bigger when the sheets are also wetted from the opposite side. The stronger adhesion is accompanied by a profound change in the correlations among water molecules across the sheet. While partial charges on water molecules interacting across an insulator sheet attract charges of the opposite sign, apparent attraction among like charges is manifested across the conducting graphene. The change is associated with graphene polarization, as the image charges inside the conductor attract equally signed partial charges of water molecules on both sides of the sheet. Additionally, by using a non-polar liquid (diiodomethane), we affirm a detectable wetting translucency when liquid-liquid forces are dominated by dispersive interactions. Furthermore, our findings are important for predictive modeling toward a variety of applications including sensors, fuel cell membranes, water filtration, and graphene-based electrode materials in high-performance supercapacitors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Flash healing of laser-induced graphene

The advancement of laser-induced graphene (LIG) technology has streamlined the fabrications of flexible graphene devices. However, the ultrafast kinetics triggered by laser irradiation generates intrinsic amorphous characteristics, leading to high resistivity and compromised performance in electronic devices. Healing graphene defects in specific patterns is technologically challenging by conventional methods. Herein, we report the rapid rectification of LIG’s topological defects by flash Joule heating in milliseconds (referred to as F-LIG), whilst preserving its overall structure and porosity. The F-LIG exhibits a decreased I D /I G ratio from 0.84 – 0.33 and increased crystalline domain from Raman analysis, coupled with a 5-fold surge in conductivity. Pair distribution function and atomic-resolution imaging delineate a broader-range order of F-LIG with a shorter C-C bond of 1.425 Å. The improved crystallinity and conductivity of F-LIG with excellent flexibility enables its utilization in high-performance soft electronics and low-voltage disinfections. Notably, our F-LIG/polydimethylsiloxane strain sensor exhibits a gauge factor of 129.3 within 10% strain, which outperforms pristine LIG by 800%, showcasing significant potential for human-machine interfaces.

36 MATERIALS SCIENCE↗

Intermetallic Pd3Pb Nanowire Networks Boost Ethanol Oxidation and Oxygen Reduction Reaction with Significantly Improved Methanol Tolerance

Intermetallic nanocrystals are currently receiving extensive attentions due to their well- defined crystal structures, highly ordered atomic distribution and superior structural stability that endow them with optimized catalytic activities, stabilities and high selectivity as electrocatalysts for fuel cells. Here, for the first time, we reported the facile synthesis of intermetallic Pd3Pb nanowire networks (IM-Pd3Pb NNs) with a one-step wet-chemical strategy at a relatively low temperature (i.e. 170 °C) in 1 h. The as-prepared IM-Pd3Pb NNs exhibited superior bifunctional catalytic performances toward oxygen reduction reaction (ORR) and ethanol oxidation reaction (EtOR) compared to commercial Pt/C and Pd black, respectively. Significantly, IM-Pd3Pb NNs also showed excellent methanol- and CO-tolerant ability as ORR cathode and EtOR anode electrocatalysts, respectively. The electrochemical active surface area and mass activity of IM-Pd3Pb NNs are about 3.4 times and 2 times higher than Pd black toward EtOR, respectively. As the Pt-free bifunctional electrocatalysts, 3D IM-Pd3Pb architectures with exceptional catalytic performances hold great promise in various applica-tions of energy conversion and storage devices, sensors, electronics, optics and so on.

Shi, Qiurong↗

Direct Lorentz force compensation flowmeter for electrolytes

A simplified method of contactless Lorentz force (LF) measurements for flow meters on electrolytes is described and realized. Modification and comparative representation are discussed against recently well-developed methods. Based on the catapult effect, that current carrying conductor experiences a repulsive force in a magnetic field, we demonstrate force measurement method of LF velocimetry applications by commonly known “electromagnetic force” compensation principle. Measurement approach through zero point stability is considered to minimize mechanical influences and avoid gravimetric uncertainties. Here, the current carrying wires are static fixed in the vicinity of magnet system at zero point stable position, while occurring deflection of magnets by electrolyte flow is compensated by external applied current within wires. Measurements performed by developed servo-system which drives control loop by means of optical position sensor for simplified (i) single wire and (ii) coil-like extended compensation schemes. Guided by experiments on electrolyte flow, we demonstrate the applicability of adopted principle for conductivities ranging from 2 to 20 S/m. Further improvements are discussed in agreement with the parameters of demonstration setup, straightforward theory, and experimental results. We argue that this method is potentially suitable for: (a) applications with higher conductivity like molten metal (order of 10{sup 6 }S/m) assuming spatial configuration of setup and (b) for lower range of conductivity (below 1 S/m) while this is strongly subject to stiffness of system and noise mainly mechanical and thermal radiations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Output-weighted sampling for multi-armed bandits with extreme payoffs

We present a new type of acquisition function for online decision-making in multi-armed and contextual bandit problems with extreme payoffs. Specifically, we model the payoff function as a Gaussian process and formulate a novel type of upper confidence bound acquisition function that guides exploration towards the bandits that are deemed most relevant according to the variability of the observed rewards. This is achieved by computing a tractable likelihood ratio that quantifies the importance of the output relative to the inputs and essentially acts as an attention mechanism that promotes exploration of extreme rewards. Our formulation is supported by asymptotic zero-regret guarantees, and its performance is demonstrated across several synthetic benchmarks, as well as two realistic examples involving noisy sensor network data. Finally, we provide a JAX library for efficient bandit optimization using Gaussian processes.

Science & Technology - Other Topics↗

Hyperspectral target detection using manifold learning and multiple target spectra

Imagery collected from satellites and airborne platforms provides an important tool for remotely analyzing the content of a scene. In particular, the ability to remotely detect a specific material within a scene is of critical importance in nonproliferation and other applications. The sensor systems that process hyperspectral images collect the high-dimensional spectral information necessary to perform these detection analyses. For a d-dimensional hyperspectral image, however, where d is the number of spectral bands, it is common for the data to inherently occupy an m-dimensional space with m << d. In the remote sensing community, this has led to recent interest in the use of manifold learning, which seeks to characterize the embedded lower-dimensional, nonlinear manifold that the data discretely approximate. The research presented in this paper focuses on a graph theory and manifold learning approach to target detection, using an adaptive version of locally linear embedding that is biased to separate target pixels from background pixels. Finally, this approach incorporates multiple target signatures for a particular material, accounting for the spectral variability that is often present within a solid material of interest.

97 MATHEMATICS AND COMPUTING↗

Prioritized Threshold Allocation for Distributed Frequency Response

Higher penetration of renewable generation will increase the demand for adequate (and cost-effective) controllable resources on the grid that can mitigate and contain the contingencies locally before it can cause a network-wide collapse. However, end-use constraints can potentially lead to load unavailability when an event occurs, leading to unreliable demand response services. Sensors measurements and knowledge of the local load dynamics could be leveraged to improve the performance of load control algorithms. In the context of hierarchical frequency response using ensemble of switching loads, we present a metric to evaluate the fitness of each device in successfully providing the ancillary service. Furthermore a fitness-based assignment of control set-points is formulated which achieves reliable performance under different operating conditions. Monte Carlo simulations of ensembles of electric water heaters and residential air-conditioners are performed to evaluate the proposed control algorithm.

Nandanoori, Sai Pushpak↗

Design and Characterization of a MEMS Probe Scanner for On-chip Atomic Force Microscopy

This paper presents the design and characterization of a microelectromechanical systems (MEMS)-based probe scanner proposed to function as an on-chip atomic force microscope (AFM). The device comprises an in-plane stage with electrostatic actuators and electrothermal displacement sensors. The stage is able to precisely position an AFM probe over a sample to perform tapping-mode AFM imaging. For implementation, a standard silicon-on-insulator (SOI) microfabrication process is used. In a previously reported design, the embedded AFM probe featured only one piezoelectric transducer for simultaneous actuation and sensing, making its use in imaging problematic. To address this issue, the new design features separate actuation and sensing AlN piezoelectric transducers. An extra electrode is also incorporated on the probe that enables canceling the electrical feedthrough from the actuation to sensing. To accommodate the extra signal routing paths, mechanical design of the probe scanner is modified. Device characterization reveals an in-plane displacement range of 8 µm×7 µm with a bandwidth of up to 2.7 kHz. The frequencydomain behavior of the AFM probe is also studied and feedthrough cancellation is performed at the resonant frequency of 127.35 kHz.

42 ENGINEERING↗

Visual Measurement of Suture Strain for Robotic Surgery

Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Mercury Specie and Multi-Pollutant Control

This project was awarded to demonstrate the ability to affect and optimize mercury speciation and multi-pollutant control using non-intrusive advanced sensor and optimization technologies. The intent was to demonstrate plant-wide optimization systems on a large coal fired steam electric power plant in order to minimize emissions, including mercury (Hg), while maximizing efficiency and maintaining saleable byproducts. Advanced solutions utilizing state-of-the-art sensors and neural network-based optimization and control technologies were proposed to maximize the removal of mercury vapor from the boiler flue gas thereby resulting in lower uncontrolled releases of mercury into the atmosphere. Budget Period 1 (Phase I) - Included the installation of sensors, software system design and establishment of the as-found baseline operating metrics for pre-project and post-project data comparison. Budget Period 2 (Phase II) - Software was installed, data communications links from the sensors were verified, and modifications required to integrate the software system to the DCS were performed. Budget Period 3 (Phase III) - Included the validation and demonstration of all control systems and software, and the comparison of the optimized test results with the targets established for the project site. This report represents the final technical report for the project, covering the entire award period and representing the final results compared to project goals. NeuCo shouldered 61% of the total project cost; while DOE shouldered the remaining 39%. The DOE requires repayment of its investment. This repayment will result from commercial sales of the products developed under the project. NRG's Limestone power plant (formerly owned by Texas Genco) contributed the host site, human resources, and engineering support to ensure the project's success.

01 COAL, LIGNITE, AND PEAT↗

Data Visualization: Augmented Reality

In recent years, there has been an increasing interest in developing new technologies for automated characterization and visualization of condition monitoring data. Augmented Reality (AR) is a technology that is being developed to improve such data visualization. Augmented reality has been defined as a technology that merges virtual and physical components in real-time, and in three dimensions. Wearable, commercially-available AR devices allow onsite engineers and technicians to perform inspection tasks with significantly more available information such as comparisons of past and present sensor and imager data, onsite data analysis and result displays, and various forms of metadata including technical drawings, previous inspection reports and maintenance histories, operation manuals, codes and standards, and holograms representing data analysis results superimposed onto the in situ monitored system.

42 ENGINEERING↗