Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Feasibility of coherent X-ray production by X-ray pumping

It is suggested that coherent X-rays can be produced by inverting the electron population in a suitable target, such as Li, through irradiation with X-rays generated by fast electrons traversing an electromagnetic field (as in a storage ring). Conditions to be satisfied by target and radiation parameters are stated, and examples given.

Csonka, P. L.↗

Relative abundances of positrons and antiprotons in the primary cosmic ray flux

Observations on the ratio of positrons to the electron-positron sum made in the 5 to 50 GeV range by Buffington et al. (1974) are used to put an upper limit on the ratio of antiprotons to protons at various energies. The calculation of the latter ratio is based on detailed measurements of the cross section of antiproton production up to intersecting storage ring energies.

Badhwar, G. D.↗

Unfolding first and second order diffracted radiation when using synchrotron radiation sources - A technique

A technique is presented of using a single calibrated XUV detector for radiometric measurements of synchrotron radiation after the radiation passes through a monochromator that produces a mixture of first- and second-order diffracted radiation. Irradiance measurements are made with the synchrotron source operating at two different energies for the orbiting electrons. The known change in the spectral distribution produced by the electron energy change is used to calculate the flux in both first and second order. The dependence of the precision of these determinations on the two detected currents and on the detector calibration at both first- and second-order wavelengths is calculated. Experimental results using the National Bureau of Standards synchrotron (SURF-I) are presented, and anticipated results for the new NBS electron storage ring (SURF-II) are calculated.

Saloman, E. B.↗

Feasibility of coherent X-ray production by X-ray pumping

It is suggested that coherent soft X rays can be produced by inverting the electron population in a suitable target, such as Li, through irradiation with X rays generated by fast electrons traversing an electromagnetic field (as in a storage ring). Conditions to be satisfied by target and radiation parameters are stated, and examples given.

Csonka, P. L.↗

Measurements of selected psi /3684/ branching ratios from a study of secondary lepton pairs

The measurements considered were made at the electron-positron storage ring at the Stanford Linear Accelerator Center. The apparatus used consists of two identical spectrometers mounted in a collinear configuration about the beam-interaction region. The energies of secondary electrons or positrons are measured with good resolution in large NaI(Tl) total-absorption detectors. Data accumulated without gamma-ray converters were examined for electron-positron pairs. The data taken with gamma-ray converters in place and at center-of-mass energies within 1 MeV of the resonance energy were scanned for evidence of either charged particles or converted gamma rays accompanying the detected muon pairs.

Hilger, E.↗

Search for monenergetic gamma rays from psi /3684/ decay

Results are reported of a search for monoenergetic gamma rays with energies above 50 MeV arising from psi (3684) decay. The measurements were made by operating an electron-positron storage ring at a center-of-mass energy of 3684 MeV and detecting the secondary gamma rays with large-crystal NaI(T1) spectrometers. No significant evidence is found for the emission of such radiation, and upper limits are placed on such emissions for energies above 50 MeV.

Simpson, J. W.↗

A calibration of detectors and gratings between 100 and 600 Angstroms

Calibration and efficiency measurements of magnetic electron multipliers, diffraction gratings, and photocathodes over the wavelength range 100 to 600 A are reported. For some of the measurements it was found necessary to use the synchrotron radiation from a storage ring. Measurements of grating efficiencies, the polarization produced by diffraction gratings, and the photoelectric yields of various photocathodes are included.

Samson, J. A. R.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. XXI - Absolute energy distribution of stars in the ultraviolet

The absolute energy distribution in the ultraviolet is given for the stars alpha Vir, eta UMa, and alpha Leo. The calibration is based on absolute heterochromatic photometry between 2920 and 1370 A carried out with an Aerobee sounding rocket. The fundamental radiation standard is the synchrotron radiation from 240-MeV electrons in a certain synchrotron storage ring. On the basis of the sounding-rocket calibration, the preliminary OAO-2 spectrometer calibration has been revised; the fluxes for the three program stars are tabulated in energy per second per square centimeter per unit wavelength interval.

Bless, R. C.↗

An investigation of high-multiplicity gamma events in pp collisions with c.m. energies between 22 and 62 GeV

An experiment was conducted at the CERN intersecting storage rings using colliding proton beams to investigate high-multiplicity gamma-ray events. The objective of the study was to reveal certain features of multiple pion production as well as other possible mechanisms of gamma-ray production. The detector system consisted of ten planes of spark chambers, three scintillation counter hodoscopes and two arrays of lead-glass Cerenkov counters, the first array containing 16 counters and the second, 60 counters. The event trigger was obtained from the Cerenkov counters, and the energies in all the Cerenkov counters after trigger, as well as the information on all the charged particles given by the scintillation counters and spark chambers were recorded on magnetic tape. The relationship between the number of gamma-rays per event and the number of Cerenkov counters triggered by a neutral secondary was established by means of a Monte Carlo calculation.

Dell, G. F.↗

Flywheel energy storage. II - Magnetically suspended superflywheel

This article, the second of a two part paper, describes the general design requirements for a flywheel energy storage system. A new superflywheel energy storage system, using a spokeless, magnetically suspended, composite material pierced disk rotor is proposed. The new system is configured around a permanent magnet ('flux biased') magnetic suspension system with active control in the radial direction and passive control in the axial direction. The storage ring is used as a moving rotor and electronic commutation of stationary armature coils is proposed. There is no mechanical contact with the rotating ring and long life and low run down losses are projected. A discussion of major components for a 10 kwh system is presented.

Kirk, J. A.↗

Lyman-alpha fluorescence from hydrogen photofragments of CH4 and H2O

The process of H-Lyman-alpha fluorescence produced through photodissociation of CH4 and H2O provides an example for the usefulness of the detection of fluorescence of dissociation fragments as an aid in identifying some high lying Rydberg states. In the first experiment reported, an electron storage ring synchrotron radiation source was used. The fluorescence produced was detected with a solar blind photomultiplier and a Cs photocathode with a spectral sensitivity in the wavelength range from 1050 to 1950 A. In the second experiment considered, an intense atomic line source was employed.

Wu, C. Y. R.↗

Study of the potential usefulness of superfine holographic x-ray gratings in AXAF and astrophysics in general

Present day high energy electron storage rings and insertion devices (wigglers and undulators) provide the necessary technology to manufacture superfile (line density or=100,00/mm) holographic X-ray gratings. The usefulness in future astrophysical research of such gratings is determined, as a function of the grating size and line density. A model design is given for an instrument which would fit within the (presently specified) constraints of the planned Advanced X-ray Astrophysics Facility (AXAF).

Csonka, P. L.↗

Photoabsorption cross section of acetylene in the EUV region

The measurement of the absolute photoabsorption cross sections of C2H2 in the 175-740 A region by means of a double ionization chamber is reported. The continuum background source is the synchrotron radiation emitted by the Wisconsin 240 MeV electron storage ring. It is found that the cross sections range from 2 to a maximum of 36 Mb. Two new Rydberg series are identified and the cross section data are applied in the analysis of various sum rules. From the rules, it is shown that the data of C2H2 in the 580-1088 A range may be too low, while the measured ionization transition moment may be too high.

Wu, C. Y. R.↗

Calculations on the production and use of superfine holographic X-ray gratings for astrophysical observations

Superfine holograhic X-ray gratings may be produced by transferring onto metal an interference pattern generated by two branches of a sufficiently coherent X-ray beam, emitted in the form of synchrotron radiation from high energy electron storage rings. Generation of the coherent beam requires restrictions on the beam size. A calculation is presented which allows an exact evaluation of this restriction. The effect of defocusing optics on the expected resolution is also studied.

Csonka, P. L.↗

Trace element abundance determinations by Synchrotron X Ray Fluorescence (SXRF) on returned comet nucleus mineral grains

Trace element analyses were performed on bulk cosmic dust particles by Proton Induced X Ray Emission (PIXE) and Synchrotron X Ray Fluorescence (SXRF). When present at or near chondritic abundances the trace elements K, Ti, Cr, Mn, Cu, Zn, Ga, Ge, Se, and Br are presently detectable by SXRF in particles of 20 micron diameter. Improvements to the SXRF analysis facility at the National Synchrotron Light Source presently underway should increase the range of detectable elements and permit the analysis of smaller samples. In addition the Advanced Photon Source will be commissioned at Argonne National Laboratory in 1995. This 7 to 8 GeV positron storage ring, specifically designed for high-energy undulator and wiggler insertion devices, will be an ideal source for an x ray microprobe with one micron spatial resolution and better than 100 ppb elemental sensitivity for most elements. Thus trace element analysis of individual micron-sized grains should be possible by the time of the comet nucleus sample return mission.

Flynn, G. J.↗

Non-destructive trace element microanalysis of as-received cometary nucleus samples using synchrotron x ray fluorescence

The Synchrotron X ray Fluorescence (SXRF) microprobe at the National Synchrotron Light Source (NSLS), Brookhaven National Laboratory, will be an excellent instrument for non-destructive trace element analyses of cometary nucleus samples. Trace element analyses of as-received cometary nucleus material will also be possible with this technique. Bulk analysis of relatively volatile elements will be important in establishing comet formation conditions. However, as demonstrated for meteorites, microanalyses of individual phases in their petrographic context are crucial in defining the histories of particular components in unequilibrated specimens. Perhaps most informative in comparing cometary material with meteorites will be the halogens and trace metals. In-situ, high spatial resolution microanalyses will be essential in establishing host phases for these elements and identifying terrestrial (collection/processing) overprints. The present SXRF microprobe is a simple, yet powerful, instrument in which specimens are excited with filtered, continuum synchrotron radiation from a bending magnet on a 2.5 GeV electron storage ring. A refrigerated cell will be constructed to permit analyses at low temperatures. The cell will consist essentially of an air tight housing with a cold stage. Kapton windows will be used to allow the incident synchrotron beam to enter the cell and fluorescent x rays to exit it. The cell will be either under vacuum or continuous purge by ultrapure helium during analyses. Several other improvements of the NSLS microprobe will be made prior to the cometary nucleus sample return mission that will greatly enhance the sensitivity of the technique.

Sutton, S. R.↗

Development and calibration of UV/VUV radiometric sources

A program exists at NIST to calibrate radiometric sources for the spectral range from 118-350 nm. These include deuterium lamps, hollow-cathode lamps, RF-excited dimer lamps, and wall-stabilized argon arcs. Sources have been calibrated for and used by researchers in solar physics, astrophysics, atmospheric physics (ozone measurements), magnetically controlled fusion, and photobiology. The argon arcs were developed in our laboratory, and provide intense sources of both radiance and irradiance. Calibrations are performed relative to two primary sources, a wall-stabilized hydrogen arc and a 12,000 K black-body line arc, both developed in our laboratory. Also we recently have begun periodic calibrations on the NIST storage ring, SURF II, to insure consistency between our respective radiometric bases. Various sources have been calibrated for space' applications, including several which are flyable. Also, some development and testing of radiometers for semiconductor lithography were recently carried out with an intense argon arc source.

Bridges, J. M.↗

UV/VUV radiometric calibrations at SURF II

Since 1981 more than 150 instrument calibrations have been performed on the radiometric instrumentation calibration beamline at the Synchrotron Ultraviolet Radiation Facility (SURF II) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland. This 300 MeV electron storage ring operates routinely at electron currents greater than 250 mA. The spectrometer calibration beamline provides a continuum of radiation from 4 nm through the visual spectral region in the form of an intense beam with total angular divergence of 1.2 mrad. The probable uncertainty for the flux ranges from about 5 percent at 4 nm to less than 2 percent above 20 nm. The new system will radiometrically trace to SURF II, and thus is expected to reduce the calibration uncertainty for diodes in this region by a factor of five to the 1-2 percent level.

Furst, Mitchell L.↗