Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

An EPID based method for efficient and precise asymmetric jaw alignment quality assurance

Purpose: The aim of this work was to investigate the use of amorphous silicon electronic portal imaging devices (EPIDs) for regular quality assurance of linear accelerator asymmetric jaw junctioning. Methods: The method uses the beam central axis position on the EPID measured to subpixel accuracy found from two EPID images with 180 degree sign opposing collimator angles. Individual zero jaw position (''half-beam blocked'') images are then acquired and the jaw position precisely determined for each using penumbra interpolation. The accuracy of determining jaw position with the EPID method was measured by translating a block (simulating a jaw) by known distances, using a translation stage, and then measuring each translation distance with the EPID. To establish the utility of EPID based junction dose measurements, radiographic film measurements of junction dose maxima/minima as a function of jaw gap/overlap were made and compared to EPID measurements. Using the method, the long-term stability of zero jaw positioning was assessed for four linear accelerators over a 1-1.5 yr time period. The stability at nonzero gantry angles was assessed over a shorter time period. Results: The accuracy of determining jaw translations with the method was within 0.14 mm found using the translation stage [standard deviation (SD) of 0.037 mm]. The junction doses measured with the EPID were different from film due to the nonwater equivalent EPID scattering properties and hence different penumbra profile. The doses were approximately linear with gap or overlap, and a correction factor was derived to convert EPID measured junction dose to film measured equivalent. Over a 1 yr period, the zero jaw positions at gantry zero position were highly reproducible with an average SD of 0.07 mm for the 16 collimator jaws examined. However, the average jaw positions ranged from -0.7 to 0.9 mm relative to central axis for the different jaws. The zero jaw position was also reproducible at gantry 90 degree sign position with 0.1 mm SD variation with the mean jaw position offset from the gantry zero position consistently by 0.3-0.4 mm for the jaws studied. Conclusions: The EPID based method is efficient and yields more precise data on linear accelerator jaw positioning and reproducibility than previous methods. The results highlight that zero jaw positions are highly reproducible to a level much smaller than the displayed jaw resolution and that there is a need for better methods to calibrate the jaw positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Deep Learning Models for Climate-Related Natural Disaster Detection from UAV Images and Remote Sensing Data

This research study utilized artificial intelligence (AI) to detect natural disasters from aerial images. Flooding and desertification were two natural disasters taken into consideration. The Climate Change Dataset was created by compiling various open-access data sources. This dataset contains 6334 aerial images from UAV (unmanned aerial vehicles) images and satellite images. The Climate Change Dataset was then used to train Deep Learning (DL) models to identify natural disasters. Four different Machine Learning (ML) models were used: convolutional neural network (CNN), DenseNet201, VGG16, and ResNet50. These ML models were trained on our Climate Change Dataset so that their performance could be compared. DenseNet201 was chosen for optimization. All four ML models performed well. DenseNet201 and ResNet50 achieved the highest testing accuracies of 99.37% and 99.21%, respectively. This research project demonstrates the potential of AI to address environmental challenges, such as climate change-related natural disasters. This study’s approach is novel by creating a new dataset, optimizing an ML model, cross-validating, and presenting desertification as one of our natural disasters for DL detection. Three categories were used (Flooded, Desert, Neither). Our study relates to AI for Climate Change and Environmental Sustainability. Drone emergency response would be a practical application for our research project.

AI↗

Physics-based shape matching for intraoperative image guidance

Purpose: Soft-tissue deformations can severely degrade the validity of preoperative planning data during computer assisted interventions. Intraoperative imaging such as stereo endoscopic, time-of-flight or, laser range scanner data can be used to compensate these movements. In this context, the intraoperative surface has to be matched to the preoperative model. The shape matching is especially challenging in the intraoperative setting due to noisy sensor data, only partially visible surfaces, ambiguous shape descriptors, and real-time requirements. Methods: A novel physics-based shape matching (PBSM) approach to register intraoperatively acquired surface meshes to preoperative planning data is proposed. The key idea of the method is to describe the nonrigid registration process as an electrostatic–elastic problem, where an elastic body (preoperative model) that is electrically charged slides into an oppositely charged rigid shape (intraoperative surface). It is shown that the corresponding energy functional can be efficiently solved using the finite element (FE) method. It is also demonstrated how PBSM can be combined with rigid registration schemes for robust nonrigid registration of arbitrarily aligned surfaces. Furthermore, it is shown how the approach can be combined with landmark based methods and outline its application to image guidance in laparoscopic interventions. Results: A profound analysis of the PBSM scheme based on in silico and phantom data is presented. Simulation studies on several liver models show that the approach is robust to the initial rigid registration and to parameter variations. The studies also reveal that the method achieves submillimeter registration accuracy (mean error between 0.32 and 0.46 mm). An unoptimized, single core implementation of the approach achieves near real-time performance (2 TPS, 7–19 s total registration time). It outperforms established methods in terms of speed and accuracy. Furthermore, it is shown that the method is able to accurately match partial surfaces. Finally, a phantom experiment demonstrates how the method can be combined with stereo endoscopic imaging to provide nonrigid registration during laparoscopic interventions. Conclusions: The PBSM approach for surface matching is fast, robust, and accurate. As the technique is based on a preoperative volumetric FE model, it naturally recovers the position of volumetric structures (e.g., tumors and vessels). It cannot only be used to recover soft-tissue deformations from intraoperative surface models but can also be combined with landmark data from volumetric imaging. In addition to applications in laparoscopic surgery, the method might prove useful in other areas that require soft-tissue registration from sparse intraoperative sensor data (e.g., radiation therapy)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Multi-pass Thomson scattering measurement on the TST-2 spherical tokamak

In multi-pass Thomson scattering (TS) scheme, a laser pulse makes multiple round trips through the plasma, and the effective laser energy is enhanced, and we can increase the signal-to-noise ratio as a result. We have developed a coaxial optical cavity in which a laser pulse is confined, and we performed TS measurements using the coaxial cavity in tokamak plasmas for the first time. In the optical cavity, the laser energy attenuation was approximately 30% in each round trip, and we achieved a photon number gain of about 3 compared with that obtained in the first round trip. In addition, the temperature measurement accuracy was improved by accumulating the first three round trip waveforms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Slope Error Measurement Tool for Solar Parabolic Trough Collectors: Preprint

The National Renewable Energy Laboratory (NREL) has developed an optical measurement tool for parabolic solar collectors that measures the combined errors due to absorber misalignment and reflector slope error. The combined absorber alignment and reflector slope errors are measured using a digital camera to photograph the reflected image of the absorber in the collector. Previous work using theimage of the reflection of the absorber finds the reflector slope errors from the reflection of the absorber and an independent measurement of the absorber location. The accuracy of the reflector slope error measurement is thus dependent on the accuracy of the absorber location measurement. By measuring the combined reflector-absorber errors, the uncertainty in the absorber location measurementis eliminated. The related performance merit, the intercept factor, depends on the combined effects of the absorber alignment and reflector slope errors. Measuring the combined effect provides a simpler measurement and a more accurate input to the intercept factor estimate. The minimal equipment and setup required for this measurement technique make it ideal for field measurements.

14 SOLAR ENERGY↗

TU-C-BRE-10: A Streamlined Approach to EPID Transit Dosimetry

Purpose: To investigate the feasibility of a simple and efficient transit dosimetry method using the electronic portal imaging device (EPID) for dose delivery error detection and prevention. Methods: In the proposed method, 2D reference transit images are generated for comparison with online images acquired during treatment. Reference transit images are generated by convolving through-air EPID measurements of each field with pixel-specific kernels selected from a library of pre-calculated Monte Carlo pencil kernels of varying radiological thickness. The kernel used for each pixel is selected based on the calculated radiological thickness of the patient along a line joining the pixel and the virtual source. The accuracy of the technique was evaluated in flat homogeneous and heterogeneous plastic water phantoms, a heterogeneous cylindrical phantom, and an anthropomorphic head phantom. Gamma criteria of 3%/3 mm was used to quantify the accuracy of the technique for the various cases. Results: An average of 99.9% and 99.7% of the points in the comparison between the measured and predicted images passed a 3%/3mm gamma for the homogeneous and heterogeneous plastic water phantoms, respectively. 97.1% of the points passed for the analysis of the heterogeneous cylindrical phantom. For the anthropomorphic head phantom, an average of 97.8% of points passed the 3%/3mm gamma criteria for all field sizes. Failures were observed primarily in areas of drastic thickness or material changes and at the edges of the fields. Conclusion: The data suggest that the proposed transit dosimetry method is a feasible approach to in vivo dose monitoring. Future research efforts could include implementation for more complex fields and sensitivity testing of the method to setup errors and changes in anatomy. Oncology Data Systems provided partial funding support but did not participate in the collection or analysis of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second release of the CoRe database of binary neutron star merger waveforms

Abstract We present the second data release of gravitational waveforms from binary neutron star (BNS) merger simulations performed by the Computational Relativity ( CoRe ) collaboration. The current database consists of 254 different BNS configurations and a total of 590 individual numerical-relativity simulations using various grid resolutions. The released waveform data contain the strain and the Weyl curvature multipoles up to ℓ = m = 4 . They span a significant portion of the mass, mass-ratio, spin and eccentricity parameter space and include targeted configurations to the events GW170817 and GW190425. CoRe simulations are performed with 18 different equations of state, seven of which are finite temperature models, and three of which account for non-hadronic degrees of freedom. About half of the released data are computed with high-order hydrodynamics schemes for tens of orbits to merger; the other half is computed with advanced microphysics. We showcase a standard waveform error analysis and discuss the accuracy of the database in terms of faithfulness. We present ready-to-use fitting formulas for equation of state-insensitive relations at merger (e.g. merger frequency), luminosity peak, and post-merger spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative Analysis Guidance in Safety Software Validation

Quantitative analysis in software development has been a challenging topic over the years in safety software. While qualitative processes for vigorous safety software verification and validation (V and V) have been provided through standard such as IEEE 1012, quantitative analysis for V and V tasks such as correctness, completeness or accuracy evaluation have not been formally defined. In practice, there are quantitative analyses in terms of using software metrics. Many of these software metrics are useful in analyzing the test results. Some of them are used for providing guidance in code evaluation activities e.g. numbers of line of codes not exceeding certain limits, recursive calls are not allowed, etc. However, few can be used for providing quantitative analysis guidance for the V and V tasks such as completeness evaluation. AREVA Federal Services (AFS) has provided services for many nuclear projects in US. Through compliance with IEEE 1012, AFS V and V processes have provided vigorous qualitative processes ensuring quality level of the software products used in the project meeting the required nuclear software level. In addition, quantitative analysis is developed to provide structured validation framework ensuring 'zero defect' in the software products. This paper describes some aspects of the quantitative approaches using a sample safety application. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Failure Detection Strategy for Intrafraction Prostate Motion Monitoring With On-Board Imagers for Fixed-Gantry IMRT

Purpose: To develop methods to monitor prostate intrafraction motion during fixed-gantry intensity-modulated radiotherapy using MV treatment beam imaging together with minimal kV imaging for a failure detection strategy that ensures prompt detection when target displacement exceeds a preset threshold. Methods and Materials: Real-time two-dimensional (2D) marker position in the MV image plane was obtained by analyzing cine-MV images. The marker's in-line movement, and thus its time-varying three-dimensional (3D) position, was estimated by combining the 2D projection data with a previously established correlative relationship between the directional components of prostate motion. A confirmation request for more accurate localization using MV-kV triangulation was triggered when the estimated prostate displacement based on the cine-MV data was greater than 3 mm. An interventional action alert followed on positive MV-kV confirmation. To demonstrate the feasibility and accuracy of the proposed method, simulation studies of conventional-fraction intensity-modulated radiotherapy sessions were done using 536 Calypso-measured prostate trajectories from 17 radiotherapy patients. Results: A technique for intrafraction prostate motion management has been developed. The technique, using 'freely available' cine-MV images and minimum on-board kV imaging (on average 2.5 images/fraction), successfully limited 3D prostate movement to within a range of 3 mm relative to the MV beam for 99.4% of the total treatment time. On average, only approximately one intervention/fraction was needed to achieve this level of accuracy. Conclusion: Instead of seeking to accurately and continuously localize the prostate target as existing motion tracking systems do, the present technique effectively uses cine-MV data to provide a clinically valuable way to minimize kV usage, while maintaining high targeting accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report for "Non-Accelerator Physics – Research in High Energy Physics: Dark Energy Research on DES"

One of the greatest mysteries in modern cosmology is the fact that the expansion of the universe is observed to be accelerating. This acceleration may stem from dark energy, an additional energy component of the universe, or may indicate that the theory of general relativity is incomplete on cosmological scales. The growth rate of large-scale structure in the universe and particularly the largest collapsed structures, clusters of galaxies, is highly sensitive to the underlying cosmology. Clusters will provide one of the single most precise methods of constraining dark energy with the ongoing Dark Energy Survey (DES). The accuracy of the cosmological constraints derived from DES clusters necessarily depends on having an optimized and well-calibrated algorithm for selecting clusters as well as an optical richness estimator whose mean relation and scatter compared to cluster mass are precisely known. Calibrating the galaxy cluster richness-mass relation and its scatter was the focus of the funded work. Specifically, we employ X-ray observations and optical spectroscopy with the Keck telescopes of optically-selected clusters to calibrate the relationship between optical richness (the number of galaxies in a cluster) and underlying mass. This work also probes aspects of cluster selection like the accuracy of cluster centering which are critical to weak lensing cluster studies.

43 PARTICLE ACCELERATORS↗

Diagnosing collisions of magnetized, high energy density plasma flows using a combination of collective Thomson scattering, Faraday rotation, and interferometry (invited)

A suite of laser based diagnostics is used to study interactions of magnetised, supersonic, radiatively cooled plasma flows produced using the Magpie pulse power generator (1.4 MA, 240 ns rise time). Collective optical Thomson scattering measures the time-resolved local flow velocity and temperature across 7–14 spatial positions. The scattering spectrum is recorded from multiple directions, allowing more accurate reconstruction of the flow velocity vectors. The areal electron density is measured using 2D interferometry; optimisation and analysis are discussed. The Faraday rotation diagnostic, operating at 1053 nm, measures the magnetic field distribution in the plasma. Measurements obtained simultaneously by these diagnostics are used to constrain analysis, increasing the accuracy of interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IDENTIFICATIONS AND PHOTOMETRIC REDSHIFTS OF THE 2 Ms CHANDRA DEEP FIELD-SOUTH SOURCES

We present reliable multiwavelength identifications and high-quality photometric redshifts for the 462 X-ray sources in the {approx}2 Ms Chandra Deep Field-South (CDF-S) survey. Source identifications are carried out using deep optical-to-radio multiwavelength catalogs, and are then combined to create lists of primary and secondary counterparts for the X-ray sources. We identified reliable counterparts for 442 (95.7%) of the X-ray sources, with an expected false-match probability of {approx} 6.2%; we also selected four additional likely counterparts. The majority of the other 16 X-ray sources appear to be off-nuclear sources, sources associated with galaxy groups and clusters, high-redshift active galactic nuclei (AGNs), or spurious X-ray sources. A likelihood-ratio method is used for source matching, which effectively reduces the false-match probability at faint magnitudes compared to a simple error-circle matching method. We construct a master photometric catalog for the identified X-ray sources including up to 42 bands of UV-to-infrared data, and then calculate their photometric redshifts (photo-z's). High accuracy in the derived photo-z's is accomplished owing to (1) the up-to-date photometric data covering the full spectral energy distributions (SEDs) of the X-ray sources, (2) more accurate photometric data as a result of source deblending for {approx}10% of the sources in the infrared bands and a few percent in the optical and near-infrared bands, (3) a set of 265 galaxy, AGN, and galaxy/AGN hybrid templates carefully constructed to best represent all possible SEDs, (4) the Zurich Extragalactic Bayesian Redshift Analyzer used to derive the photo-z's, which corrects the SED templates to best represent the SEDs of real sources at different redshifts and thus improves the photo-z quality. The reliability of the photo-z's is evaluated using the subsample of 220 sources with secure spectroscopic redshifts. We achieve an accuracy of |{delta}z|/(1 + z) {approx} 1% and an outlier [with |{delta}z|/(1 + z)>0.15] fraction of {approx}1.4% for sources with spectroscopic redshifts. We performed blind tests to derive a more realistic estimate of the photo-z quality for sources without spectroscopic redshifts. We expect there are {approx}9% outliers for the relatively brighter sources (R {approx}< 26), and the outlier fraction will increase to {approx}15%-25% for the fainter sources (R {approx}> 26). The typical photo-z accuracy is {approx}6%-7%. The outlier fraction and photo-z accuracy do not appear to have a redshift dependence (for z {approx} 0-4). These photo-z's appear to be the best obtained so far for faint X-ray sources, and they have been significantly ({approx}>50%) improved compared to previous estimates of the photo-z's for the X-ray sources in the {approx}2 Ms Chandra Deep Field-North and {approx}1 Ms CDF-S.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband, high dynamics and high resolution charge coupled device-based spectrometer in dynamic mode for multi-keV repetitive x-ray sources

We present a new operating mode, using a charged coupled device as dispersionless spectrometer dedicated to repetitive x-ray sources in the multi-keV domain. This enables to get spectra with high statistics in a short acquisition time and a way compatible with the operation of other diagnostics requiring accumulation. Several reconstruction algorithms for the spreading events are discussed, and a near Fano-limited resolution is demonstrated by using single pixel events. In this case, a method to take into account partial canceling of the events is presented. Experimental characterization and detailed modeling of the detector are performed, which allow to determine absolute number of photon with {+-}35% accuracy. Characterization of the 5-25 keV x rays emitted by a short pulse laser-produced plasma is reported, as well as their dependency with the atomic number, the laser duration, and energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the energy distribution of laser-generated relativistic electrons in cone-wire targets

Transport of relativistic electrons in a solid Cu wire target has been modeled with the implicit hybrid particle-in-cell code LSP to investigate the electron energy distribution and energy coupling from the high-intensity, short-pulse laser to electrons entering to the wire. Experiments were performed on the TITAN laser using a 1.5 mm long Cu wire attached to a Au cone tip at the laser intensity of 1 Multiplication-Sign 10{sup 20} W/cm{sup 2} which was irradiated into the cone. The simulated Cu K{alpha} wire profile and yields matched the measurements using a two-temperature energy distribution. These modeling results show that the cold component of the energy spectrum can be determined with {+-}100 keV accuracy from the fit to the initial experimental fall-off of the K{alpha} emission while the simulated profiles were relatively insensitive to the hotter component of the electron distribution (>4 MeV). The slope of measured escaped electrons was used to determine the hotter temperature. Using exponential energy distributions, the laser-to-electron-in-wire coupling efficiencies inferred from the fits decreased from 3.4% to 1.5% as the prepulse energy increases up to 1 J. The comparison of the energy couplings using the exponential and Relativistic Maxwellian distribution functions showed that the energy inferred in the cold component is independent of the type of the distribution function.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum compatible sample positioning device for matrix assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry imaging

The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in {approx}1 x 10{sup -8} mbar vacuum. The range of motion is set to 100 mm x 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption/ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The ''oversampling'' MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple method for the measurement of reflective foil emissivity

Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pseudopotentials for quantum Monte Carlo studies of transition metal oxides

Quantum Monte Carlo (QMC) calculations of transition metal oxides are partially limited by the availability of high-quality pseudopotentials that are both accurate in QMC and compatible with major plane-wave electronic structure codes. We have generated a set of neon-core pseudopotentials with small cutoff radii for the early transition metal elements Sc to Zn within the local density approximation of density functional theory. The pseudopotentials have been directly tested for accuracy within QMC by calculating the first through fourth ionization potentials of the isolated transition metal (M) atoms and the binding curve of each M-O dimer. We find the ionization potentials to be accurate to 0.16(1) eV, on average, relative to experiment. The equilibrium bond lengths of the dimers are within 0.5(1)% of experimental values, on average, and the binding energies are also typically accurate to 0.18(3) eV. The level of accuracy we find for atoms and dimers is comparable to what has recently been observed for bulk metals and oxides using the same pseudopotentials. Our QMC pseudopotential results compare well with the findings of previous QMC studies and benchmark quantum chemical calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compositional analysis of GaAs/AlGaAs heterostructures using quantitative scanning transmission electron microscopy

We demonstrate a method for compositional mapping of Al{sub x}Ga{sub 1–x}As heterostructures with high accuracy and unit cell spatial resolution using quantitative high angle annular dark field scanning transmission electron microscopy. The method is low dose relative to spectroscopic methods and insensitive to the effective source size and higher order lens aberrations. We apply the method to study the spatial variation in Al concentration in cross-sectioned GaAs/AlGaAs core-shell nanowires and quantify the concentration in the Al-rich radial band and the AlGaAs shell segments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗