At least 1,783 records · Page 99

The New Structural Materials Science Beamlines BL8A and 8B at Photon Factory

BL8A and 8B are new beamlines for structural materials science at Photon Factory. The primary characteristics of both beamlines are similar. The incident beam is monochromatized by the Si(111) double-flat crystal monochromator and focused at the sample position by a Rh-coated bent cylindrical quartz mirror. The Weissenberg-camera-type imaging-plate (IP) diffractometers were installed. The X-ray diffraction experiments for structural studies of strongly correlated materials, such as transition metals, molecular conductors, endohedral fullerenes, nano-materials, etc, are conducted at these stations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Super-radiance in the sodium resonance lines from sodium iodide arc lamps

Super-radiance observed within the centers of the sodium resonance D lines emitted by arc lamps containing sodium iodide as additive in a high-pressure mercury plasma environment was studied by high-resolution emission spectroscopy. The spectral radiance of these self-reversed lines including super-radiance was simulated by considering a local enhancement of the source function due to the presence of an additional source of radiation near the arc wall. Causes of this hitherto unrecognized source of radiation are given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Impact of the Sun on Passive Remote Sensing at L-band

The sun is a strong source of radiation at L-band behaving roughly like a thermal source with a temperature ranging between 10(exp 5) - 10(exp 7) K, depending on solar activity. This is an important consideration at 1.4 GHz (the window set aside for passive use only) where future satellite sensors will operate to monitor soil moisture and sea surface salinity (e.g. SMOS, Aquarius, and Hydros). Straight forward calculations show that such a source of radiation can be a significant issue for these remote sensing applications, especially in the case of remote sensing of sea surface salinity. Radiation from the sun impacts passive remote sensing systems in several ways. First, is the solar radiation that comes directly from the sun (line-of-sight from sun to spacecraft that enters the radiometer through antenna side lobes). This is a particular problem for sensors in sunsynchronous orbits near the terminator (e.g. orbits with equatorial crossing times near 6am/6pm) because the spacecraft is in the sun most of the time. Second, is solar radiation that is reflected (specularly) from the mean surface to the radiometer. This contribution can be nearly as large as the direct ray, especially when the reflection is from the ocean surface which has a high reflection coefficient. Finally, there is "incoherent" signal reflected from the surface structure (roughness) to the radiometer antenna. Examples illustrating the significance of these terms is presented for the case of a pushbroom radiometer such as Aquarius and a conically scanning radiometer such as proposed for Hydros. Calculations are made using a set of theoretical patterns for these beams together with data on solar radiation obtained from by a worldwide network of observing stations known as Radio Solar Telescope Network (RSTN). Near solar minimum, solar contamination is not a problem unless the sun enters near the main beam. But near solar maximum, account must be made for radiation from the sun even when the signal enters in sidelobes far from the main beam.

LeVine, David M.↗

Assessment on security system of radioactive sources used in hospitals of Thailand

Unsecured radioactive sources have caused deaths and serious injuries in many parts of the world. In Thailand, there are 17 hospitals that use teletherapy with cobalt-60 radioactive sources. They need to be secured in order to prevent unauthorized removal, sabotage and terrorists from using such materials in a radiological weapon. The security system of radioactive sources in Thailand is regulated by the Office of Atoms for Peace in compliance with Global Threat Reduction Initiative (GTRI), U.S. DOE, which has started to be implemented since 2010. This study aims to perform an assessment on the security system of radioactive sources used in hospitals in Thailand and the results can be used as a recommended baseline data for development or improvement of hospitals on the security system of a radioactive source at a national regulatory level and policy level. Results from questionnaires reveal that in 11 out of 17 hospitals (64.70%), there were a few differences in conditions of hospitals using radioactive sources with installation of the security system and those without installation of the security system. Also, personals working with radioactive sources did not clearly understand the nuclear security law. Thus, government organizations should be encouraged to arrange trainings on nuclear security to increase the level of understanding. In the future, it is recommended that the responsible government organization issues a minimum requirement of nuclear security for every medical facility using radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

NEAR-INFRARED COUNTERPARTS TO CHANDRA X-RAY SOURCES TOWARD THE GALACTIC CENTER. I. STATISTICS AND A CATALOG OF CANDIDATES

We present a catalog of 5184 candidate infrared counterparts to X-ray sources detected toward the Galactic center. The X-ray sample contains 9017 point sources detected in this region by the Chandra X-ray Observatory during the past decade, including data from a recent deep survey of the central 2{sup 0} x 0.{sup 0}8 of the Galactic plane. A total of 6760 of these sources have hard X-ray colors, and the majority of them lie near the Galactic center, while most of the remaining 2257 soft X-ray sources lie in the foreground. We cross-correlated the X-ray source positions with the 2MASS and SIRIUS near-infrared catalogs, which collectively contain stars with a 10sigma limiting flux of K{sub s} <= 15.6 mag. In order to distinguish absorbed infrared sources near the Galactic center from those in the foreground, we defined red and blue sources as those which have H - K{sub s} >= 0.9 and <0.9 mag, respectively. We find that 5.8% +- 1.5% (2sigma) of the hard X-ray sources have real infrared counterparts, of which 228 +- 99 are red and 166 +- 27 are blue. The red counterparts are probably comprised of Wolf-Rayet and O stars, high-mass X-ray binaries, and symbiotic binaries located near the Galactic center. Foreground X-ray binaries suffering intrinsic X-ray absorption could be included in the sample of blue infrared counterparts to hard X-ray sources. We also find that 39.4% +- 1.0% of the soft X-ray sources have blue infrared counterparts; most of these are probably coronally active dwarfs in the foreground. There is a noteworthy collection of {approx}20 red counterparts to hard X-ray sources near the Sagittarius B H II region, which are probably massive binaries that have formed within the last several Myr. For each of the infrared matches to X-ray sources in our catalog we derived the probability that the association is real, based on the source properties and the results of the cross-correlation analysis. These data are included in our catalog and will serve spectroscopic surveys to identify infrared counterparts to X-ray sources near the Galactic center.

79 ASTRONOMY AND ASTROPHYSICS↗

Physiologically gated microbeam radiation using a field emission x-ray source array

Purpose: Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. Methods: The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic{sup ©} films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only during a portion of the mouse respiratory cycle when there was minimum motion. Parallel planes of microbeams with 12.4 Gy/plane dose and 900 μm pitch were delivered. The microbeam profiles with and without gating were analyzed using γ-H2Ax immunofluorescence staining. Results: The phantom study showed that the respiratory motion caused a 50% drop in PVDR from 11.5 when there is no motion to 5.4, whereas there was only a 5.5% decrease in PVDR for gated irradiation compared to the no motion case. In thein vivo study, the histology result showed gating increased PVDR by a factor of 2.4 compared to the nongated case, similar to the result from the phantom study. The full width at tenth maximum of the microbeam decreased by 40% in gating in vivo and close to 38% with phantom studies. Conclusions: The CNT field emission x-ray source array can be synchronized to physiological signals for gated delivery of x-ray radiation to minimize motion-induced beam blurring. Gated MRT reduces valley dose between lines during long-time radiation of a moving object. The technique allows for more precise MRT treatments and makes the CNT MRT device practical for extended treatment.

60 APPLIED LIFE SCIENCES↗

Thermal Fatigue Life of Glidcop Al-15 High-Heat-Load Components

Shanghai Synchrotron Radiation Facility (SSRF) is a third-generation of synchrotron radiation light source and is presently under construction as a large scale national scientific project in China. Depending on the outstanding thermal and mechanical performance, Glidcop Al-15, a dispersion strengthened copper alloy, is chosen to serve for the high-heat-load components at beam line front end in SSRF. Present study is to investigate the thermal fatigue lives of critical SSRF components. A nonlinear finite element method (FEM) is used to simulate the nonlinear three dimensional stress-strain fields of the critical component-Mask2 at SSRF beam line. The method consists of transient temperature analyses followed by elastic-plastic stress analyses. Then, a critical plane approach is used to predict the thermal fatigue life of mask2. The critical plane approach is appropriate for estimating service life of critical SSRF components since the results are in good consistent with the experimental ones taken at the Advanced Photon Source (APS).

36 MATERIALS SCIENCE↗

Picosecond Short-Range Disordering in Isochorically Heated Aluminum at Solid Density

Using ultrafast x-ray probing, we experimentally observed a progressive loss of ordering within solid-density aluminum as the temperature raises from 300 K to >10{sup 4} K. The Al sample was isochorically heated by a short ({approx}ps), laser-accelerated proton beam and probed by a short broadband x-ray source around the Al K edge. The loss of short-range ordering is detected through the progressive smoothing of the time-resolved x-ray absorption near-edge spectroscopy (XANES) structure. The results are compared with two different theoretical models of warm dense matter and allow us to put an upper bound on the onset of ion lattice disorder within the heated solid-density medium of {approx}10 ps.

07 ISOTOPE AND RADIATION SOURCES↗

Hard X-ray Fourier Transform Holography Using a Reference Scatterer Fabricated by Electron-Beam-Assisted Chemical-Vapor Deposition

We present a fabrication method for a reference source that is efficient when used for lensless Fourier transform holography. This method produces a reference source that yields high spatial resolution and enhanced signal-to-noise ratio in a Fourier-transformed real-space image, and is particularly useful for Fourier transform holography experiments in the hard x-ray region.

07 ISOTOPE AND RADIATION SOURCES↗

Electron-Impact Water-Jet Microfocus Source for Water-Window Microscopy

We demonstrate high-brightness operation of an electron-impact water-jet-anode soft x-ray source with an increased power loading of 15 times compared to our previously published results, with a corresponding increase in {approx}525-eV x-ray intensity of 6.4 times. This has been accomplished by improving the vacuum pumping system and the electron focusing optics, and increasing the liquid-jet velocity. The source now operates up to 120-W e-beam power and at a 525-eV brightness of 3.5x10{sup 9} ph/(sx{mu}m{sup 2}xsrxline). The source concept has potential to increase the x-ray brightness by another order of magnitude by optimizing the e-beam focusing and upgrading the power supply. Currently, spot enlargement with increased power is determined to be the most important limiting factor.

07 ISOTOPE AND RADIATION SOURCES↗

HARD X-RAYS AS A DIAGNOSTIC TOOL FOR WARM DENSE MATTER

We present the application of short-pulse laser-driven hard x-rays (>40 keV) for the direct density measurement of iron compressed by a laser-driven shock. By using an on-shot calibration of the line density, we are able to obtain line densities even though the x-ray source is not monochromatic. The consequences for the line density measurement using a polychromatic source are discussed in detail, as well as the calibration method we propose to solve this problem.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation Simulation using Wi-Fi Signal Strength and Frequency

For routine radiological operations, lost radioactive sources, decommissioning and cleanup of nuclear facilities, and radiological terrorist events such as Radioactive Dispersive Devices (RDDs) or Radiological Exposure Devices (REDs), individuals are tasked with accurately locating both point and distributed sources of radiation. Radiation workers must often practice these tasks, whether part of initial training or periodically as part of formal or informal exercises or drills. In such circumstances, it is desirable to have an accurate recreation of a radioactive source, including a method of detecting it, which does not include dangerous amounts of radiation. The goal of this research was to develop a radiation simulation technology that uses IEEE 802.11x W-LAN protocol, i.e. Wi-Fi sources and detectors for these, as an inexpensive, precise and accurate method of replicating sources of gamma radiation. For this work, existing 802.11x sources were used. Software was developed for use with an Android smartphone to detect the presence of these sources. The measurements followed the expected behavior as a function of distance from the sources, mimicking that of gamma radiation, thus demonstrating the fundamental principle of operation. The ultimate system will be used in an outreach program to interest students in the radiation protection field.

07 ISOTOPE AND RADIATION SOURCES↗

Web-based visual data exploration for improved radiological source detection

Radiation detection can provide a reliable means of detecting radiological material. Such capabilities can help to prevent nuclear and/or radiological attacks, but reliable detection in uncontrolled surroundings requires algorithms that account for environmental background radiation. The Berkeley Data Cloud (BDC) facilitates the development of such methods by providing a framework to capture, store, analyze, and share data sets. In the era of big data, both the size and variety of data make it difficult to explore and find data sets of interest and manage the data. Thus, in the context of big data, visualization is critical for checking data consistency and validity, identifying gaps in data coverage, searching for data relevant to an analyst's use cases, and choosing input parameters for analysis. Downloading the data and exploring it on an analyst's desktop using traditional tools are no longer feasible due to the size of the data. This study describes the design and implementation of a visualization system that addresses the problems associated with data exploration within the context of the BDC. Finally, the visualization system is based on a JavaScript front end communicating via REST with a back end web server.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Long-Term Results of an RTOG Phase II Trial (00-19) of External-Beam Radiation Therapy Combined With Permanent Source Brachytherapy for Intermediate-Risk Clinically Localized Adenocarcinoma of the Prostate

Purpose: External-beam radiation therapy combined with low-doserate permanent brachytherapy are commonly used to treat men with localized prostate cancer. This Phase II trial was performed to document late gastrointestinal or genitourinary toxicity as well as biochemical control for this treatment in a multi-institutional cooperative group setting. This report defines the long-term results of this trial. Methods and Materials: All eligible patients received external-beam radiation (45 Gy in 25 fractions) followed 2-6 weeks later by a permanent iodine 125 implant of 108 Gy. Late toxicity was defined by the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring scheme. Biochemical control was defined by the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus definition and the ASTRO Phoenix definition. Results: One hundred thirty-eight patients were enrolled from 20 institutions, and 131 were eligible. Median follow-up (living patients) was 8.2 years (range, 2.7-9.3 years). The 8-year estimate of late grade >3 genitourinary and/or gastrointestinal toxicity was 15%. The most common grade >3 toxicities were urinary frequency, dysuria, and proctitis. There were two grade 4 toxicities, both bladder necrosis, and no grade 5 toxicities. In addition, 42% of patients complained of grade 3 impotence (no erections) at 8 years. The 8-year estimate of biochemical failure was 18% and 21% by the Phoenix and ASTRO consensus definitions, respectively. Conclusion: Biochemical control for this treatment seems durable with 8 years of follow-up and is similar to high-dose external beam radiation alone or brachytherapy alone. Late toxicity in this multi-institutional trial is higher than reports from similar cohorts of patients treated with high-dose external-beam radiation alone or permanent low-doserate brachytherapy alone, perhaps suggesting further attention to strategies that limit doses to normal structures or to unimodal radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗