Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Properties of Heavy Cosmic Nuclei Phosphorus, Chlorine, Argon, Potassium, and Calcium: Results from the Alpha Magnetic Spectrometer

We report the unique properties of cosmic phosphorus (P), chlorine (Cl), argon (Ar), potassium (K), and calcium (Ca) fluxes in the GV to TV rigidity range collected by the Alpha Magnetic Spectrometer (AMS) on the International Space Station. With a total of one million events collected over 13.5 years, we observed that the rigidity dependencies of the five fluxes are well described by the sums of a primary cosmic ray component and a secondary cosmic ray component. The abundance ratios of all five elements to Si at the source are accurately determined independent of cosmic ray propagation. The source abundance of Ar and Ca (even-𝑍 elements) is larger than P, Cl, and K (odd-𝑍 elements). The secondary components of the P and the Cl fluxes are each ∼1/3 of the F flux, and the secondary components of the Ar, K, and Ca fluxes are each ∼1/2 of the F flux. The twenty elements measured by AMS, from He to Ca and Fe, can be categorized into four classes, two primary and two secondary, based on their rigidity dependence.

cosmic ray acceleration↗

SU-D-207-05: Real-Time Intrafractional Motion Tracking During VMAT Delivery Using a Conventional Elekta CBCT System

Purpose: Real-time kV projection streaming capability has become recently available for Elekta XVI version 5.0. This study aims to investigate the feasibility and accuracy of real-time fiducial marker tracking during CBCT acquisition with or without simultaneous VMAT delivery using a conventional Elekta linear accelerator. Methods: A client computer was connected to an on-board kV imaging system computer, and receives and processes projection images immediately after image acquisition. In-house marker tracking software based on FFT normalized cross-correlation was developed and installed in the client computer. Three gold fiducial markers with 3 mm length were implanted in a pelvis-shaped phantom with 36 cm width. The phantom was placed on a programmable motion platform oscillating in anterior-posterior and superior-inferior directions simultaneously. The marker motion was tracked in real-time for (1) a kV-only CBCT scan with treatment beam off and (2) a kV CBCT scan during a 6-MV VMAT delivery. The exposure parameters per projection were 120 kVp and 1.6 mAs. Tracking accuracy was assessed by comparing superior-inferior positions between the programmed and tracked trajectories. Results: The projection images were successfully transferred to the client computer at a frequency of about 5 Hz. In the kV-only scan, highly accurate marker tracking was achieved over the entire range of cone-beam projection angles (detection rate / tracking error were 100.0% / 0.6±0.5 mm). In the kV-VMAT scan, MV-scatter degraded image quality, particularly for lateral projections passing through the thickest part of the phantom (kV source angle ranging 70°-110° and 250°-290°), resulting in a reduced detection rate (90.5%). If the lateral projections are excluded, tracking performance was comparable to the kV-only case (detection rate / tracking error were 100.0% / 0.8±0.5 mm). Conclusion: Our phantom study demonstrated a promising Result for real-time motion tracking using a conventional Elekta linear accelerator. MV-scatter suppression is needed to improve tracking accuracy during MV delivery. This research is funded by Motion Management Research Grant from Elekta.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-01: A Novel and Efficient Daily QA Program for Both Modern Linear Accelerator and Optical Surface Motion Systems

Purpose: The camera-based optical surface monitoring system(OSMS) is a standard motion-tracking system for TrueBeam™ machine. Daily quality assurance(DQA) procedures for the TrueBeam and OSMS systems currently require multiple phantoms and test sequences. Machine Performance Check(MPC) uses the IsoCal™ phantom to test geometric and dosimetric aspects, and has been validated for routine TrueBeam DQA. This work examines the novel use of MPC to simultaneously conduct DQA of OSMS,utilizing one phantom and test sequence for QA of both the TrueBeam and OSMS systems. Methods: TrueBeam with 6 degree-of-freedom(6DOF) couch, MPC and OSMS were installed. The therapists routinely use MPC with the IsoCal phantom to verify geometric and dosimetric parameters with an automated sequence of varying gantry and collimator angles, MLC positions, and couch translations and rotations as the DQA for TrueBeam. A surface outline of the IsoCal phantom, generated from a CT dataset, was imported to OSMS and used to monitor the position of the phantom at isocenter and to track its movement up to 5cm/10°(yaw) and rotation in pitch and roll up to 3° in real time during the automated MPC sequence. Motion of the phantom throughout the MPC routine was compared to the couch position shown by the digital readout. Results: The coincidence of isocenter, as determined by OSMS, and TrueBeam radiation isocenter was within ±0.8mm/±0.8° in three axes. Between OSMS and TrueBeam 6DOF couch, the mean couch relative shifts/angles were within ±0.7mm/±0.8° for each axis. Reported pitch and roll values were within ±0.4mm/±0.4°. The total measurement time for each DQA session took approximately 5 minutes. Conclusion: Use of the IsoCal phantom and MPC for simultaneous DQA of TrueBeam and OSMS increases QA efficiency and reduces complexity. OSMS isocenter position and motion-tracking capability in 6DOF were verified in real-time and were found to be within 1mm of the expected value.

60 APPLIED LIFE SCIENCES↗

Microphysical-macrophysical interactions in low cloud systems over the Eastern North Atlantic

How low clouds over the oceans respond to changes in atmospheric greenhouse gases and aerosol particles is poorly understood. Climate model disagreement in these responses limits the accuracy of predictions of future climate. Processes governing the behavior of marine low cloud need to be improved in models and comprehensive long-term observations provide important constraints. Cloud structure and impacts on climate are shaped by processes operating on a wide range of time and space scales, which interact to modulate cloud dynamics, boundary layer structure, and precipitation. The Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) site at Graciosa Island (Azores, 28°W 39°N) began taking measurements in late 2013 to address the need for comprehensive cloud, aerosol, and meteorological observations in a remote marine low cloud environment. The site straddles the boundary between the subtropical and midlatitude climate zones in the eastern North Atlantic and experiences a great diversity of meteorological and cloud conditions. In addition, the ENA site is downwind of the North American continent and is periodically impacted by continental aerosol particles transported there on the prevailing winds. In response to a 2014 proposal call, our team (ENA Site Science Team) laid out a strategy to accelerate research focused on understanding the multi-scale interactions that shape cloud properties by maximizing the utility of the observational capabilities of the ENA site. The proposed work aligned with the scientific directions of the ASR Working Groups. The team, together with collaborators, conducted a program of research focused upon multi-scale cloud processes. The team worked with scientists both within and outside the Atmospheric System Research (ASR) program, and with the ARM infrastructure to ensure that the full potential of the ENA site is realized. The suite of instruments at the ENA site has been increasing since the site’s inception and is now essentially complete. In 2019, we laid out a two-year extension of the research, and were granted an extension of the Site Science award.

54 ENVIRONMENTAL SCIENCES↗

Advanced Photon Source Upgrade Project - Materials

An upgrade to Advanced Photon Source announced by DOE - http://go.usa.gov/ivZ -- will help scientists break through bottlenecks in materials design in order to develop materials with desirable functions.

43 PARTICLE ACCELERATORS↗

Energy Sources for Yotta-TeV Iceberg Showers

In late February of 2002, warming climate along the Antarctic Peninsula triggered a macroscopic particle acceleration event that smashed a 350 Gkg floating ice shelf, called the Larsen B. The particle shower released by the acceleration involved on the order of >10^6 iceberg particles accelerated to an aggregate total kinetic energy of ~10^17 J (100 Mt TNT equivalent). The explosion was so extreme that it caught glaciological science by surprise (an injury to the egos of glaciologists worldwide) and caused glaciers of the Antarctic Peninsula formerly buttressed by the missing ice shelf to surge (yielding a small increment to sea level rise). In this presentation, I shall describe research, both experimental and field oriented, that has revealed the energy source for this explosive event. I shall also describe how climate warming has the capacity to trigger this type of ice-shelf collapse. A review of the geologic record of ice-rafted debris on the ocean floor suggests that extreme, explosive ice-shelf collapse may be a ubiquitous catastrophe that has happened regularly in the past as part of glacial/interglacial climate cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 MeV ≤ E{sub n} ≤ 16 MeV) based on a few measurements with quasi-monoenergetic neutrons. This method is needed because a complete set of measurements is not available and the alternative approach of using responses based on Monte Carlo calculations is not feasible. Our approach uses Bayesian signal-background separation techniques and radial basis function interpolation methods. We present the analysis of data measured at the PTB accelerator facility PIAF. The method is quite general and it can be applied to other particle detectors with similar characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-Driven Analysis of Multipactor Dynamics via Dynamic Mode Decomposition

Multipactor effect is a performance-limiting kinetic plasma effect that can occur in high-power microwave and radio frequency (RF) devices. Multipactor effect is of special concern in vacuum or near-vacuum conditions such as those in particle accelerators and spaceborne devices. In this work, we present a data-driven reduced-order model (ROM) based on dynamic mode decomposition (DMD) for modeling of multipactor effects. We study multipactor effects and the resulting nonlinear harmonic generation by processing high-fidelity data generated from electromagnetic particle-in-cell (EMPIC) simulations using the DMD algorithm. We also investigate time-delay embedding extensions of DMD with improved generalizability and accuracy for modeling the electron plasma current density behavior. Here, the results show that DMD provides valuable insights into multipactor phenomena by extracting relevant modal spatiotemporal patterns and frequencies. In addition, DMD offers the potential to time extrapolate EMPIC simulations at a minimal cost, thereby reducing overall simulation time.

43 PARTICLE ACCELERATORS↗

MO-DE-BRA-03: TOPAS-edu: A Window Into the Stochastic World Through the TOPAS Tool for Particle Simulation

Purpose: The stochastic nature of the subatomic world presents a challenge for physics education. Even experienced physicists can be amazed at the varied behavior of electrons, x-rays, protons, neutrons, ions and the any short-lived particles that make up the overall behavior of our accelerators, brachytherapy sources and medical imaging systems. The all-particle Monte Carlo particle transport tool, TOPAS Tool for Particle Simulation, originally developed for proton therapy research, has been repurposed into a physics teaching tool, TOPAS-edu. Methods: TOPAS-edu students set up simulated particle sources, collimators, scatterers, imagers and scoring setups by writing simple ASCII files (in the TOPAS Parameter Control System format). Students visualize geometry setups and particle trajectories in a variety of modes from OpenGL graphics to VRML 3D viewers to gif and PostScript image files. Results written to simple comma separated values files are imported by the student into their preferred data analysis tool. Students can vary random seeds or adjust parameters of physics processes to better understand the stochastic nature of subatomic physics. Results: TOPAS-edu has been successfully deployed as the centerpiece of a physics course for master’s students at Queen’s University Belfast. Tutorials developed there takes students through a step by step course on the basics of particle transport and interaction, scattering, Bremsstrahlung, etc. At each step in the course, students build simulated experimental setups and then analyze the simulated results. Lessons build one upon another so that a student might end up with a full simulation of a medical accelerator, a water-phantom or an imager. Conclusion: TOPAS-edu was well received by students. A second application of TOPAS-edu is currently in development at Zurich University of Applied Sciences, Switzerland. It is our eventual goal to make TOPAS-edu available free of charge to any non-profit organization, along with associated tutorial materials developed by the TOPAS-edu community. Work supported in part by the U.S. Department of Energy under contract number DE-AC02-76SF00515. B. Villagomez-Bernabe is supported by CONACyT (Mexican Council for Science and Technology) project 231844.

60 APPLIED LIFE SCIENCES↗

Development of a magnetized coaxial plasma gun for compact toroid injection into the C-2 field-reversed configuration device

A compact toroid (CT) injector was developed for the C-2 device, primarily for refueling of field-reversed configurations. The CTs are formed by a magnetized coaxial plasma gun (MCPG), which consists of coaxial cylindrical electrodes and a bias coil for creating a magnetic field. First, a plasma ring is generated by a discharge between the electrodes and is accelerated by Lorenz self-force. Then, the plasma ring is captured by an interlinkage flux (poloidal flux). Finally, the fully formed CT is ejected from the MCPG. The MCPG described herein has two gas injection ports that are arranged tangentially on the outer electrode. A tungsten-coated inner electrode has a head which can be replaced with a longer one to extend the length of the acceleration region for the CT. The developed MCPG has achieved supersonic CT velocities of ∼100 km/s. Plasma parameters for electron density, electron temperature, and the number of particles are ∼5 × 10{sup 21} m{sup −3}, ∼40 eV, and 0.5–1.0 × 10{sup 19}, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Steering Group Report

The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOvA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed significantly, a central feature of the proposed Fermilab plan calls for building an intense proton facility, Project X, consisting of a linear accelerator with the currently planned characteristics of the ILC combined with Fermilab's existing Recycler Ring and the Main Injector accelerator. The major component of Project X is the linac. Cryomodules, radio-frequency distribution, cryogenics and instrumentation for the linac are the same as or similar to those used in the ILC at a scale of about one percent of a full ILC linac. Project X's intense proton beams would open a path to discovery in neutrino science and in precision physics with charged leptons and quarks. World-leading experiments would allow physicists to address key questions of the Quantum Universe: How did the universe come to be? Are there undiscovered principles of nature: new symmetries, new physical laws? Do all the particles and forces become one? What happened to the antimatter? Building Project X's ILC-like linac would offer substantial support for ILC development by accelerating the industrialization of ILC components in the U.S. and creating an engineering opportunity for ILC cost reductions. It o.ers an early and tangible application for ILC R&D in superconducting technology, attracting participation from accelerator scientists worldwide and driving forward the technology for still higher-energy accelerators of the future, such as a muon collider. To prepare for a future decision, the Fermilab Steering Group recommends that the laboratory seek R&D support for Project X, in order to produce an overall design of Project X and to spur the R&D and industrialization of ILC linac components needed for Project X. Advice from the High Energy Physics Advisory Panel will guide any future decision to upgrade the Fermilab accelerator complex, taking into account developments a.ecting the ILC schedule and the continuing evaluation of scientific priorities for U.S. particle physics. Fermilab should also work toward increased resources for longer-term future accelerators such as a muon collider, aiming at higher energies than the ILC would provide.

43 PARTICLE ACCELERATORS↗

Accelerator Science and Technology Breakthroughs, Achievements and Lessons from the Tevatron

For almost a quarter of a century, the Tevatron proton-antiproton collider was the centerpiece of the world's high energy physics program - beginning operation in December of 1985 until it was overtaken by LHC in 2011. The aim of this unique scientific instrument was to explore the elementary particle physics reactions with center of mass collision energies of up to 1.96 TeV. The initial design luminosity of the Tevatron was 1030cm-2s-1, however as a result of two decades of upgrades, the accelerator has been able to deliver 430 times higher luminosities to each of two high luminosity experiments, CDF and D0. The Tevatron will be shut off September 30, 2011. The collider was arguably one of the most complex research instruments ever to reach the operation stage and is widely recognized for many technological breakthroughs and numerous physics discoveries. In this John Adams lecture, I briefly present the history of the Tevatron, major advances in accelerator physics, and technology implemented during the long quest for better and better performance. Lessons learned from our experience are also discussed.

43 PARTICLE ACCELERATORS↗

The story of the Tevatron accelerators: Accelerator science and technology breakthroughs, achievements and lessons

For almost a quarter of a century, the Tevatron proton-antiproton collider was the centerpiece of the world's high energy physics program - since it began operation in December of 1985, until it was overtaken by LHC in 2011. The aim of this unique scientific instrument was to explore the elementary particle physics reactions with center of mass collision energies of up to 1.96 TeV. The initial design luminosity of the Tevatron was 10{sup 30} cm{sup -2} s{sup -1}, however as a result of two decades of upgrades, the accelerator has been able to deliver 430 times higher luminosities to each of two high luminosity experiments, CDF and D0. The Tevatron has been shut off since September 30, 2011. The collider was arguably one of the most complex research instruments ever to reach the operation stage and is widely recognized for many technological breakthroughs and numerous physics discoveries. In this paper, we briefly present the history of the Tevatron, major advances in accelerator physics, technology implemented during the long quest for better and better performance, and the lessons learned from our experience.

43 PARTICLE ACCELERATORS↗

Genesis Concentrator Target Particle Contamination Mapping and Material Identification

The majority of surface particles were found to be < 5 microns in diameter with increasing numbers close to the optical resolution limit of 0.3 microns. Acceleration grid EDS results show that the majority of materials appear to be from the SRC shell and SLA materials which include carbon-carbon fibers and Si-rich microspheres in a possible silicone binder. Other major debris material from the SRC included white paint, kapton, collector array fragments, and Al. Image analysis also revealed that SRC materials were also found mixed with the Utah mud and salt deposits. The EDS analysis of the acceleration grid showed that particles < 1 m where generally carbon based particles. Chemical cleaning techniques with Xylene and HF in an ultrasonic bath are currently being investigated for removal of small particles by the Genesis science team as well as ultra-pure water megasonic cleaning by the JSC team [4]. Removal of organic contamination from target materials is also being investigated by the science team with the use of UV-ozone cleaning devices at JSC and Open University [5]. In preparation for solar wind oxygen analyses at UCLA and Open University [1, 2], surface particle contamination on three Genesis concentrator targets was closely examined to evaluate cleaning strategies. Two silicon carbide (Genesis sample # 60001 and 60003) and one chemical vapor deposited (CVD) 13C concentrator target (60002) were imaged and mosaic mapped with optical microscopes. The resulting full target mosaic images and particle feature maps were subsequently compared with non-flight, but flight-like, concentrator targets and sample return capsule (SRC) materials. Contamination found on the flown concentrator acceleration grid was further examined using a scanning electron microscope (SEM). Energy dispersive X-ray spectroscopy (EDS) for particle identification was subsequently compared with the optical images from the flown targets. Figure 1 show that all three targets imaged in this report are fully intact and do not show any signs of material fractures. However, previous ellipsometry results and overview imaging of both flown SiC targets show a solar wind irradiation gradient from the center focal point to the outer edge [3]. In addition, due to the hard landing, each target has experienced varying degrees of impacts, scratches, and particle debris from the spacecraft and Utah impact site.

Calaway, Michael J.↗

The Implications of Experimentally Controlled Gravitational Accelerations for Combustion Science

An overview of basic combustion problems which have been investigated under the condition of reduced gravity is presented to identify promising research directions. Attention is given to the broad categories of gas-jet diffusion flames, droplet combustions, particle clouds, flame spreading over liquid pools, smoldering, and flame spreading over solid fuels. Fire safety in spacecraft is the primary application that is addressed by the studies of combustion under microgravity. The need for more complete testing of the issues discussed in orbiting spacecraft is identified in the light of limited earth-based testing. Attention is also directed toward the need for advanced diagnostic methods for in-flight and other combustion investigations.

Sacksteder, Kurt R.↗

Accelerator Production of {sup 225}Ac For Alpha-Immunotherapy

{sup 225}Ac has tremendous potential for the treatment of metastatic cancer due to the four alpha-particles emitted during its decay to stable {sup 209}Bi. Additionally, it is one of the few alpha-emitters being considered for clinical trials. The anticipated {sup 225}Ac demand for these trials is expected to far exceed the annual worldwide supply of approximately 1,000 mCi/yr. Consequently, the DOE Office of Science has funded investigations into accelerator-based production of {sup 225}Ac. Existing {sup 232}Th(p,x){sup 225}Ac cross section data indicate that up to 480 mCi/day of {sup 225}Ac could be created by bombarding a thick target of natural thorium with 100 MeV protons at the Los Alamos Isotope Production Facility. To verify these predictions, experiments are underway at the Los Alamos Neutron Science Center to measure the {sup 232}Th(p,x){sup 225}Ac production cross sections for protons in the energy range 40-200 MeV, and at 800 MeV. For 800 MeV protons, preliminary results indicate that the {sup 225}Ac production cross section is 12.4{+-}0.6 mb and the {sup 225}Ra production cross section is 3.2{+-}0.2 mb. Moreover, preliminary results suggest that the {sup 227}Ac production cross section is 16{+-}1 mb. Experiments to measure these same cross sections at proton energies below 200 MeV are planned for the last half of calendar year 2010.

43 PARTICLE ACCELERATORS↗

Timing Tricks For Complicated Accelerators [PowerPoint]

A brief description of the Los Alamos Neutron Science Center is given first, including static and dynamic scheduling. The principal tricks presented are prescient feed forward and pulser replication. Tricks with flip/flop pulsers are also included.

43 PARTICLE ACCELERATORS↗