Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHYSICS LABORATORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Characterization of Silicon PhotoMultipliers at LNS-INFN

The Silicon PhotoMultipliers (SiPMs) are a new generation of photodetectors having high sensitivity, excellent time resolution, compactness, low power supply, and insensitivity to magnetic fields. Their properties make them a valid alternative to the PMTs in several fields, such as particle physics, medicine, and space technology. At Laboratori Nazionali del Sud (LNS), a complete characterization of samples developed by different companies (Hamamatsu, STM, SensL) has been performed in order to measure the most significant properties, consisting of the dark noise, cross talk probability, photon detection efficiency, and charge and timing resolutions. Measurements have also been performed coupling the SiPMs with scintillating fibres and small size LYSO scintillators in order to investigate possible applications in Positron Emission Tomography (PET) diagnostics and in the monitoring of nuclear waste sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Radiation Dose Effects on Rat Bones Using Synchrotron Radiation Computed Microtomography

In this work, we investigated the consequences of irradiation in the femora and ribs of rats submitted to radiation doses of 5 Gy. Three different sites in femur specimens (head, distal metaphysis and distal epiphysis) and one in ribs (ventral) were imaged using synchrotron radiation microcomputed tomography to assess trabecular bone microarchitecture. Histomorphometric quantification was calculated directly from the 3D microtomographic images using synchrotron radiation. The 3D microtomographic images were obtained at the SYRMEP (SYnchrotron Radiation for MEdical Physics) beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. A better understanding of the biological interactions that occur after exposure to photon radiation is needed in order to optimize therapeutic regimens and facilitate development and strategies that decrease radiation-induced side effects in humans. Results showed significant differences between irradiated and non-irradiated specimens, mostly in head and distal metaphysis bone sites.

60 APPLIED LIFE SCIENCES↗

Results on charmonium-like states at BaBar

We present recent results on charmonium and charmonium-like states from the BaBar B-factory located at the PEP-II asymmetric energy e{sup +}e{sup -} storage ring at the SLAC National Accelerator Laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton induced quasi-monochromatic x-ray beams for soft x-ray spectroscopy studies and selective x-ray fluorescence analysis

We present the analytical features and performance of an x-ray spectroscopy end station of moderate energy resolution operating with proton-induced quasi-monochromatic x-ray beams. The apparatus was designed, installed and operated at the 5.5 MV Tandem VdG Accelerator Laboratory of the Institute of Nuclear Physics, N.C.S.R. 'Demokritos,' Athens. The setup includes a two-level ultrahigh vacuum chamber that hosts in the lower level up to six primary targets in a rotatable holder; there, the irradiation of pure element materials-used as primary targets-with few-MeV high current ({approx}{mu}A) proton beams produces intense quasi-monochromatic x-ray beams of selectable energy. In the chamber's upper level, a six-position rotatable sample holder hosts the targets considered for x-ray spectroscopy studies. The proton-induced x-ray beam, after proper collimation, is guided to the sample position whereas various filters can be also inserted along the beam's path to eliminate the backscattered protons or/and to absorb selectively components of the x-ray beam. The apparatus incorporates an ultrathin window Si(Li) spectrometer (FWHM 136 eV at 5.89 keV) coupled with low-noise electronics capable of efficiently detecting photons down to carbon K{alpha}. Exemplary soft x-ray spectroscopy studies and results of selective x-ray fluorescence analysis are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of the dielectric function for p-point water models

We compute the longitudinal dielectric function ɛl(k) for p-point water models, p = 3 (SPC/E, TIP3P), p = 4 (TIP4P-EW, OPC), and p = 5 (TIP5P-E) from the charge–charge fluctuation function SZZ(k), obtained from two methods: average of the charge in k-space (method:sum) and from the pair distribution function in Fourier space (method:integral). The latter requires a continuation to small k-values, which we thoroughly discuss. We conclude with a detailed comparison of the longitudinal dielectric function for the different p-point models and its main characteristics: small k and large k limits, position of the poles, and its (complex) zeros.

Shevy, Noah [Ames National Laboratory, Department ↗

Validation of Fast Reactor Depletion Tools Using EBR-II Measured Data

The validation of simulation tools for calculating fuel depletion and evolution in fast reactors is vital for design, licensing, deployment, operations, and material accountancy. The Physics Analysis Database (PADB) and Analytical Laboratory (AL) database contain measured data collected from Experimental Breeder Reactor II (EBR-II) and were used to validate the most recent versions of the Argonne Reactor Computation (ARC) tool suite and ORIGEN-S for calculating isotopic compositions in irradiated fast reactor fuel. The PADB contains important modeling and operational information about the EBR-II core design, fuel cycle, and analytical results from the legacy versions of the ARC tool suite. The AL database contains the measured isotopic compositions of irradiated samples taken from core subassemblies. A new procedure was developed for the ARC tool suite to perform the EBR-II depletion simulation, as well as to perform more detailed isotopic calculations using ORIGEN-S calculations by coupling it with the ARC suite. Both the ARC and ARC-ORIGEN results were compared with the AL measured data for all relevant samples and showed good agreement for the major actinides. Good agreement with measured data was also achieved using the ARC-ORIGEN approach for several fission products.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Untold Story of Building the First Megaton Thermonuclear Fusion Device: The Simple Element and IVY Mike

This report is a research and development engineer’s perspective on the fascinating story of the world’s first megaton-class thermonuclear device, IVY Mike (10.4 Mt). Few modern scientific endeavors have matched the complexity and breadth of scientific achievement in such a short amount of time as IVY Mike. This paper will take a look at the design, engineering, fielding, and execution of the world’s first megaton-class physics experiment by Los Alamos Scientific Laboratory and the birth of industrial liquid hydrogen use spawned by the Cold War effort. Although others have written on aspects of this technical history, they have not benefited from access to the original classified documents used by the present author. The present paper must necessarily omit some technical details that remain classified but represents the most comprehensive summary of the engineering and fabrication of the IVY Mike device in the open literature.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Solving the excitation and chemical abundances in shocks: The case of HH 1

We present deep spectroscopic (3600–24700 Å ) X-shooter observations of the bright Herbig–Haro object HH 1, one of the best laboratories to study the chemical and physical modifications caused by protostellar shocks on the natal cloud. We observe atomic fine structure lines, H i and He i recombination lines and H{sub 2} ro-vibrational lines (more than 500 detections in total). Line emission was analyzed by means of Non-local Thermal Equilibiurm codes to derive the electron temperature and density, and for the first time we are able to accurately probe different physical regimes behind a dissociative shock. We find a temperature stratification in the range 4000 K ÷ 80,000 K, and a significant correlation between temperature and ionization energy. Two density regimes are identified for the ionized gas, a more tenuous, spatially broad component (density ∼10{sup 3} cm{sup −3}), and a more compact component (density ⩾ 10{sup 5} cm{sup −3}) likely associated with the hottest gas. A further neutral component is also evidenced, having a temperature ≲10,000 K and a density >10{sup 4} cm{sup −3}. The gas fractional ionization was estimated by solving the ionization equilibrium equations of atoms detected in different ionization stages. We find that neutral and fully ionized regions co-exist inside the shock. Also, indications in favor of at least partially dissociative shock as the main mechanism for molecular excitation are derived. Chemical abundances are estimated for the majority of the detected species. On average, abundances of non-refractory/refractory elements are lower than solar of about 0.15/0.5 dex. This indicates the presence of dust inside the medium, with a depletion factor of iron of ∼40%.

79 ASTRONOMY AND ASTROPHYSICS↗

Muon lifetime measurement in Chiapas and the Escaramujo project

Escaramujo is a project with the goal of promote scientific development and integration regarding science for Latin America. It consists of a series of Laboratories and Workshops for High Energy Physics, astroparticle and instrumentation, given by Federico Izraelevitch. Escaramujo has been conduced at several institutions in Latin America. In this work, the moun mean lifetime measurements performed during the workshop held in Chiapas are presented. Furthermore, the results are compared with the corresponding value reported by the Particle Data Group (PDG).

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Ab initio many-fermion structure calculations on a quantum computer

To overcome the limitations of existing algorithms for solving self-bound quantum many-body problems—such as those encountered in nuclear and particle physics—that access only a restricted subset of energy levels and provide limited structural information, we introduce and demonstrate a novel quantum-classical approach capable of resolving the complete bound-state spectrum. This method also provides the total angular momentum 𝐽 associated with each eigenstate. Here, our approach is based on expressing the Hamiltonian in second-quantized form within a novel input model combined with a scan scheme, enabling broad applicability to configuration-interaction calculations across diverse fields. We apply this hybrid method to compute, for the first time, the bound-state spectrum together with corresponding 𝐽 values of 20 O using a realistic strong-interaction Hamiltonian. Our approach applies to hadron spectra and 𝐽 values solved in the relativistic basis light-front quantization approach.

Du, Weijie [Chinese Academy of Sciences (CAS), Lan↗

Quantum critical point followed by Kondo-like behavior due to Cu substitution in the itinerant antiferromagnet La 2 ⁢(Cu 𝑥 ⁢Ni 1−𝑥 ) 7

La 2 ⁢Ni 7 is an itinerant magnetic system with a small ordered moment of ∼ 0.1⁢µ 𝐵 /Ni and a series of antiferromagnetic (AFM) transitions at 𝑇 1 = 61.0K, 𝑇 2 = 56.5K, and 𝑇 3 = 42.2K. 𝑀 ⁡(𝐻), and 𝜌 ⁡(𝐻) isotherms as well as constant field 𝑀⁡ (𝑇) and 𝜌 ⁡(𝑇) measurements on single-crystalline samples manifest a complex, anisotropic 𝐻−𝑇 phase diagram with multiple phase lines. Here, in this study, we present the growth and characterization of single crystals of the La 2 ⁢(Cu 𝑥 ⁢Ni 1−𝑥 ) 7 series for 0 ≤ 𝑥 ≤ 0.181. We measured powder x-ray diffraction and composition, as well as anisotropic temperature- and field-dependent resistivity, temperature- and field-dependent magnetization, and temperature-dependent heat capacity on these single crystals. Using the measured data we infer a transition temperature-composition (𝑇−𝑥) phase diagram for this system to study the evolution of the AFM ordering upon Cu substitution. For 0 ≤ 𝑥 ≤ 0.097, the system remains magnetically ordered at base temperature with 𝑥 ≤ 0.012, showing signs of multiple AFM ordering temperatures. For the higher substitution levels 0.125 ≤ 𝑥 ≤ 0.181, there are no signatures of magnetic ordering, but anomalous features in resistance and heat capacity data are observed which are consistent with the Kondo effect in this system. The intermediate 𝑥 = 0.105 sample lies between the magnetic ordered and the Kondo regime and is in the vicinity of the AFM quantum critical point (QCP). Thus, La 2⁢ (Cu 𝑥 ⁢Ni 1−𝑥 ) 7 is an example of a small moment system that can be tuned through a QCP. Given these data combined with the fact that the La 2⁢ Ni 7 structure has kagomelike, Ni sublattices running perpendicular to the crystallographic 𝑐 axis, and a predicted 3⁢𝑑-electron flat band that contributes to the density of states near the Fermi energy, La 2 ⁢(Cu 𝑥 ⁢Ni 1−𝑥 ) 7 becomes a promising system to host and study exotic physics.

Das, Atreyee [Ames Laboratory, and Iowa State Univ↗

Resonant Raman scattering of polarized and unpolarized x-ray radiation from Mg, Al, and Si

The x-ray resonant Raman scattering (RRS) effect of polarized and unpolarized radiation in the vicinity of the 1s absorption threshold of low-Z elements such as magnesium, aluminum, and silicon is investigated. For the polarized and tunable exciting x-ray radiation the plane grating monochromator (PGM) beam line at the PTB laboratory in the BESSY II synchrotron radiation facility was employed, while unpolarized x-ray beams were induced by 1-MeV proton beam irradiation on various pure thick targets. For the latter case, a novel proton-induced x-ray fluorescence scattering chamber was designed and installed at the Tandem accelerator laboratory of the Institute of Nuclear Physics at N.C.S.R. 'Demokritos'. The total RRS cross sections deduced from both independent excitation modes were found to be in a good agreement, within the experimental uncertainties. The predictions of the existing theory with respect to the dependence of the RRS to the incident beam polarization state is calculated and discussed with respect to the experimental results.

36 MATERIALS SCIENCE↗

How fast can protons decay?

Current laboratory bounds imply that protons are extremely long-lived. However, this conclusion may not hold for all time and in all of space. We find that the proton lifetime can be ∼ 15 orders of magnitude shorter in the relatively recent past on Earth or at the present time elsewhere in the Milky Way. A number of terrestrial and astrophysical constraints are examined and potential signals are outlined. We also sketch possible models that could lead to spatial or temporal variations in the proton lifetime. A positive signal could be compelling evidence for a new long range force of nature, with important implications for the limitations of fundamental inferences based solely on laboratory measurements. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Localization Precision and Angular Resolution of a Cylindrical, Time-Encoded Imaging System From Adaptive Detector Movements

To the first order, the localization precision and angular resolution of a cylindrical, time-encoded imaging (c-TEI) system is governed by the geometry of the system. Improving either measure requires increasing the mask radius or decreasing the detector diameter, both of which are undesirable. Here, we propose an alternative option of repositioning the detector within the mask to increase the detector-to-mask distance in the direction of a source, thereby improving the localization precision and angular resolution in that direction. Since the detector-to-mask distance only increases for a small portion of the field of view (FOV), we propose implementing adaptive imaging where one leverages data collected during the measurement to optimize the system configuration. This article utilizes both simulations and experiments to set upper bounds on the potential gain from adaptive detector movements for one and two sources in the FOV. When only one source is present, adaptive detector movements can improve the localization precision and angular resolution by 20% for a source at 90 cm and by 32% for a far-field source. When two sources are present, adaptive detector movements can improve localization precision and angular resolution by up to 50% for sources that are ~10° apart (90 cm from the system). We experimentally verify these results through maximum likelihood estimation of the source position(s) and image reconstruction of point sources that are close together. As a demonstration of an adaptive imaging algorithm, we image a complex arrangement of special nuclear material at the Zero Power Physics Reactor facility at Idaho National Laboratory.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A cookbook for building a high-current dimpled H – magnetron source for accelerators

A high-current (>50 mA) dimpled H – magnetron source has been built at Fermilab for supplying H – beam to the entire accelerator complex. Despite many decades of expertise with slit H – magnetron sources at Fermilab, we were faced with many challenges from the dimpled H – magnetron source, which needed to be overcome in order to make it operational. Dimpled H – sources for high-energy physics are not new: Brookhaven National Laboratory has operated a dimpled H- source for more than two decades. However, the transference of that experience to Fermilab took about two years because a cookbook for building this type of source did not exist and seemingly innocuous or undocumented choices had a huge impact on the success or failure for this type of source. Moreover, it is the goal of this paper to document the reasons for these choices and to present a cookbook for building and operating dimpled H – magnetron sources.

43 PARTICLE ACCELERATORS↗