Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Reheating and primordial gravitational waves in generalized Galilean genesis

Galilean genesis is an alternative to inflation, in which the universe starts expanding from Minkowski with the stable violation of the null energy condition. In this paper, we discuss how the early universe is reheated through the gravitational particle production at the transition from the genesis phase to the subsequent phase where the kinetic energy of the scalar field is dominant. We then study the consequences of gravitational reheating after Galilean genesis on the spectrum of primordial gravitational waves. The resultant spectrum is strongly blue, and at high frequencies Ω{sub gw}∝ f{sup 3} in terms of the energy density per unit logarithmic frequency. Though this cannot be detected in existing detectors, the amplitude can be as large as Ω{sub gw}∼ 10{sup −12} at f∼ 100 MHz, providing a future test of the genesis scenario. The analysis is performed within the framework of generalized Galilean genesis based on the Horndeski theory, which enables us to derive generic formulas.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine learning-powered data cleaning for LEGEND: a semi-supervised approach using affinity propagation and support vector machines

Neutrinoless double-beta decay ($0\nu\beta\beta$) is a rare nuclear process that, if observed, will provide insight into the nature of neutrinos and help explain the matter-antimatter asymmetry in the Universe. The large enriched germanium experiment for neutrinoless double-beta decay (LEGEND) will operate in two phases to search for $0\nu\beta\beta$. The first (second) stage will employ 200 (1000) kg of High-Purity Germanium (HPGe) enriched in 76 Ge to achieve a half-life sensitivity of 10 27 (10 28 ) years. In this study, we present a semi-supervised data-driven approach to remove non-physical events captured by HPGe detectors powered by a novel artificial intelligence model. We utilize affinity propagation to cluster waveform signals based on their shape and a support vector machine to classify them into different categories. We train, optimize, and test our model on data taken from a natural abundance HPGe detector installed in the Full Chain Test experimental stand at the University of North Carolina at Chapel Hill. We demonstrate that our model yields a maximum sacrifice of physics events of $0.024 ^{+0.004}_{-0.003} \%$ after data cleaning. Our model is being used to accelerate data cleaning development for LEGEND-200 and will serve to improve data cleaning procedures for LEGEND-1000.

artificial intelligence↗

Experimental measurement of 12 C + 16 O fusion at stellar energies

The total cross section of the 12 C + 16 O fusion reaction has been measured at low energies to investigate the role of this reaction during late stellar evolution burning phases. A high-intensity oxygen beam, produced by the 5 MV pelletron accelerator at the University of Notre Dame, impinged on a thick, ultrapure graphite target. Protons and γ rays were simultaneously measured in the center-of-mass energy range from 3.64 to 5.01 MeV for singles and from 3.73 to 4.84 MeV for coincidence events, using silicon and Ge detectors. Statistical model calculations were employed to interpret the experimental results. The emergence of a new resonance-like broad structure and a decreasing trend in the S-factor data towards lower energies (opposite to previous data) are found for the 12 C + 16 O fusion reaction. Furthermore, based on these results the uncertainty range of the reaction rate within the temperature range of late stellar burning environments is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of 𝑑 2⁢ 𝜎/𝑑⁢|$\vec{q}$|⁢𝑑⁢𝐸 avail in charged current 𝜈 𝜇 -nucleus interactions at ⟨𝐸 𝜈 ⟩=1.86 GeV using the NOvA Near Detector

Double- and single-differential cross sections for inclusive charged-current 𝜈 𝜇 -nucleus scattering are reported for the kinematic domain 0 to 2 GeV/𝑐 in three-momentum transfer and 0 to 2 GeV in available energy, at a mean 𝜈 𝜇 energy of 1.86 GeV. The measurements are based on an estimated 995,760 𝜈 𝜇 charged-current (CC) interactions in the scintillator medium of the NOvA Near Detector. The subdomain populated by 2-particle-2-hole (2p2h) reactions is identified by the cross section excess relative to predictions for 𝜈 𝜇 -nucleus scattering that are constrained by a data control sample. Models for 2-particle-2-hole processes are rated by 𝜒 2 comparisons of the predicted-versus-measured 𝜈 𝜇 CC inclusive cross section over the full phase space and in the restricted subdomain. Shortfalls are observed in neutrino generator predictions obtained using the theory-based València and SuSAv2 2p2h models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Utilization of the Critic Subnetwork of a Generative Adversarial Network as Detector of Morphological Material Change in Image Data

The resolution of computed tomography (CT) has become high enough to monitor morphological changes due to aging in materials in long-term applications. For this work, we explored the utility of the critic of a generative adversarial network (GAN) to automatically detect such changes. The GAN was trained with images of pristine Pharmatose, which is used as a surrogate energetic material. It is important to note that images of the material with altered morphology were only used during the test phase. The GAN-generated images reproduced the microstructure of Pharmatose well, although some unrealistic particle fusion was seen. Calculated morphological metrics (volume fraction, interfacial line length, and local thickness) for the synthetic images also showed good agreement with the training data, albeit with signs of mode collapse in the interfacial line length. While the critic exposed changes in particle size, it showed limited ability to distinguish images by particle shape. The detection of shape differences was also a more challenging task for the selected morphological metrics that related to energetic material performance. We further tested the critic with images of aged Pharmatose. Subtle changes due to aging are difficult for the human analyst to detect; but both critic and morphological metrics analysis showed image differentiation.

36 MATERIALS SCIENCE↗

An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimum lithium loading of a liquid scintillator for neutron and neutrino detection

Neutral particle detection in high-background environments is greatly aided by the ability to easily load 6 Li into liquid scintillators. In this work, we describe a readily available and inexpensive liquid scintillation cocktail stably loaded with a Li mass fraction up to 1%. Compositions that give thermodynamically stable microemulsions (reverse-micellar systems) were explored, using a Compton spectrum quenching technique to distinguish these from unstable emulsions. Scintillation light yield and transmittance were characterized. Pulse shape discrimination (PSD) was measured using a 252 Cf source, showing that electron-like and proton-like recoil events are well-resolved even for Li loading up to 1%, providing a means of background suppression in neutron/neutrino detectors. While samples in this work were prepared with nat Li (7.59% 6 Li), the neutron capture peak was clearly visible in the PSD spectrum; this implies that while extremely high capture efficiency could be achieved with 6 Li-enriched material, a very inexpensive neutron-sensitive detector can be prepared with nat Li.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of B{sub s}{sup 0} Mixing Parameters from the Flavor-Tagged Decay B{sub s}{sup 0}{yields}J/{psi}{phi}

From an analysis of the flavor-tagged decay B{sub s}{sup 0}{yields}J/{psi}{phi} we obtain the width difference between the B{sub s}{sup 0} light and heavy mass eigenstates, {delta}{gamma}{sub s}=0.19{+-}0.07(stat){sub -0.01}{sup +0.02}(syst) ps{sup -1}, and the CP-violating phase, {phi}{sub s}=-0.57{sub -0.30}{sup +0.24}(stat){sub -0.02}{sup +0.08}(syst). The allowed 90% CL intervals of {delta}{gamma}{sub s} and {phi}{sub s} are 0.06<{delta}{gamma}{sub s}<0.30 ps{sup -1} and -1.20<{phi}{sub s}<0.06, respectively. The data sample corresponds to an integrated luminosity of 2.8 fb{sup -1} accumulated with the D0 detector at the Fermilab Tevatron collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of D⁺→K⁺η (') and Search for CP Violation in D⁺→π⁺η (') Decays

We report the first observation of the doubly Cabibbo-suppressed decays D⁺→K⁺η (') using a 791 fb⁻¹ data sample collected with the Belle detector at the KEKB asymmetric-energy e⁺e⁻ collider. The ratio of the branching fractions of doubly Cabibbo-suppressed relative to singly Cabibbo-suppressed D⁺→π⁺η (') decays are B(K⁺η)/B(D⁺→π⁺η)=(3.06±0.43±0.14)% and B(K⁺η (') )/B(D⁺→π⁺η (') ) = (3.77±0.39±0.10)%. From these, we find that the relative final-state phase difference between the tree and annihilation amplitudes in D⁺ decays, δ TA , is (72±9)° or (288±9)°. We also report the most precise measurements of CP asymmetries to date: A D⁺ CP =(+1.74±1.13±0.19)% and A D⁺→π+η' CP = (-0.12±1.12±0.17)%.

Won, E.↗

Crystallization and Preliminary X-ray Diffraction Analysis of Recombinant Chlorocatechol 1 2-dioxygenase from Pseudomonas Putida

Chlorocatechol 1,2-dioxygenase from the Gram-negative bacterium Pseudomonas putida (Pp 1,2-CCD) is considered to be an important biotechnological tool owing to its ability to process a broad spectrum of organic pollutants. In the current work, the crystallization, crystallographic characterization and phasing of the recombinant Pp 1,2-CCD enzyme are described. Reddish-brown crystals were obtained in the presence of polyethylene glycol and magnesium acetate by utilizing the vapor-diffusion technique in sitting drops. Crystal dehydration was the key step in obtaining data sets, which were collected on the D03B-MX2 beamline at the CNPEM/MCT - LNLS using a MAR CCD detector. Pp 1,2-CCD crystals belonged to space group P6{sub 1}22 and the crystallographic structure of Pp 1,2-CCD has been solved by the MR-SAD technique using Fe atoms as scattering centres and the coordinates of 3-chlorocatechol 1,2-dioxygenase from Rhodococcus opacus (PDB entry 2boy) as the search model. The initial model, which contains three molecules in the asymmetric unit, has been refined to 3.4 {angstrom} resolution.

54 ENVIRONMENTAL SCIENCES↗

Measurement of CP observables in B{sup {+-}{yields}D}{sub CP}K{sup {+-}}decays and constraints on the CKM angle {gamma}

Using the entire sample of 467x10{sup 6} {Upsilon}(4S){yields}BB decays collected with the BABAR detector at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, we perform an analysis of B{sup {+-}}{yields}DK{sup {+-}}decays, using decay modes in which the neutral D meson decays to either CP-eigenstates or non-CP-eigenstates. We measure the partial decay rate charge asymmetries for CP-even and CP-odd D final states to be A{sub CP+}=0.25{+-}0.06{+-}0.02 and A{sub CP-}=-0.09{+-}0.07{+-}0.02, respectively, where the first error is the statistical and the second is the systematic uncertainty. The parameter A{sub CP+} is different from zero with a significance of 3.6 standard deviations, constituting evidence for direct CP violation. We also measure the ratios of the charged-averaged B partial decay rates in CP and non-CP decays, R{sub CP+}=1.18{+-}0.09{+-}0.05 and R{sub CP-}=1.07{+-}0.08{+-}0.04. We infer frequentist confidence intervals for the angle {gamma} of the unitarity triangle, for the strong phase difference {delta}{sub B}, and for the amplitude ratio r{sub B}, which are related to the B{sup -}{yields}DK{sup -} decay amplitude by r{sub B}e{sup i({delta}{sub B}-{gamma})}=A(B{sup -}{yields}D{sup 0}K{sup -})/A(B{sup -}{yields}D{sup 0}K{sup -}). Including statistical and systematic uncertainties, we obtain 0.24<r{sub B}<0.45 (0.06<r{sub B}<0.51) and, modulo 180 deg., 11.3 deg. <{gamma}<22.7 deg. or 80.8 deg. <{gamma}<99.2 deg. or 157.3 deg. <{gamma}<168.7 deg. (7.0 deg. <{gamma}<173.0 deg.) at the 68% (95%) confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A measurement of the CP asymmetry difference between Λ c + → pK – K + and pπ – π + decays

The difference between the CP asymmetries in the decays Λ c + → pK – K + and Λ c + → pπ – π + is presented. Proton-proton collision data taken at centre-of-mass energies of 7 and 8 TeV collected by the LHCb detector in 2011 and 2012 are used, corresponding to an integrated luminosity of 3 fb –1 . The Λ c + candidates are reconstructed as part of the Λ b o → Λ c + μ – X decay chain. In order to maximize the cancellation of production and detection asymmetries in the difference, the final-state kinematic distributions of the two samples are aligned by applying phase-space-dependent weights to the Λ c + → pπ – π + sample. This alters the definition of the integrated CP asymmetry to A CP wgt (pπ – π + ).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Λ transverse polarization in e+e− collisions at $$ \sqrt{s} $$ = 3.68 − 3.71 GeV

Abstract With data samples collected with the BESIII detector at seven energy points at$$ \sqrt{s} $$ s = 3.68−3.71 GeV, corresponding to an integrated luminosity of 333 pb −1 , we present a study of the Λ transverse polarization in thee + e − →$$ \Lambda \overline{\Lambda} $$ Λ Λ ¯ reaction. The significance of polarization by combining the seven energy points is found to be 2.6σincluding the systematic uncertainty, which implies a non-zero phase between the transition amplitudes of the$$ \Lambda \overline{\Lambda} $$ Λ Λ ¯ helicity states. The modulus ratio and the relative phase of EM-psionicform factors combined with all energy points are measured to beR Ψ =$$ {0.71}_{-0.10}^{+0.10} $$ 0.71 − 0.10 + 0.10 ±0.03 and ∆Φ Ψ =$$ {23}_{-8.0}^{+8.8} $$ 23 − 8.0 + 8.8 ±1.6°, where the first uncertainties are statistical and the second systematic.

Physics↗

A simple method to fabricate an NIR detector by PbTe nanowires in a large scale

Highlights: • PbTe nanowires were grown by tellurization of the Pb sheets for the first time. • It was observed a band gap value for the PbTe nanostructures in the NIR region. • NIR detector was fabricated in a large scale using a simple method. • Effect of Te concentration on morphology of PbTe nanostructures was investigated. - Abstract: A simple method was used to fabricate a near-infrared (NIR) detector using PbTe nanostructures. Samples were synthesized by tellurization of lead sheets in a tube furnace. PbTe nanostructures with wires and flakes shapes were grown on the lead sheets that were placed at 300 and 330 °C, respectively, while, PbTe nanoporous were grown at 360 and 390 °C. X-ray diffraction patterns and X-ray photoelectron spectra results indicated that, the PbTe phase was formed in all samples. UV–vis diffuse reflectance spectra measurements showed a band gap for the PbTe nanostructures in the near-infrared region of the electromagnetic spectrum. Actually, the results indicated that, the band gap values of the PbTe nanowires and nanoporous were 1.54 eV and 1.61 eV, respectively. Finally, the PbTe nanostructures were used as a simple photoresponse device under a red light source. The photoresponse results revealed, PbTe nanowires are promising for photoelectrical applications in the NIR region.

36 MATERIALS SCIENCE↗

Characterization of molecular mass ranges of two coal tar distillate fractions (creosote and anthracene oils) and aromatic standards by LD-MS, GC-MS, probe-MS and size-exclusion chromatography

Laser-desorption mass spectrometry (LD-MS) method development was undertaken to improve estimates of mass ranges for complex hydrocarbon mixtures. A creosote oil, an anthracene oil, and a mixture of known polynuclear aromatic hydrocarbon (PAH) compounds were examined. The formation of cluster ions was possible without overloading the detector system. These multimer ions overlapped with higher-mass ion signals from the sample. However, careful balancing of sample concentration, laser power, total ion current, and delayed ion extraction appears to show high-mass materials without generating high-mass multimer (artifact) ions. It is possible to suppress the formation of cluster ions by keeping low target concentrations and, consequently, low gas phase concentrations formed by the laser pulse. The principal method used in this work was the fractionation of samples by planar chromatography followed by successive LD-MS analysis of the separated fractions directly from the chromatographic plates. This method separated the more abundant small molecules from the less abundant large molecules to permit the generation of their mass spectra independently, as well as reducing the concentration of sample by spreading over the PC-plate. The technique demonstrably suppressed multimer formation and greatly improved the reproducibility of the spectra. Results showed the presence of molecule ions in the ranges m/z 1000-2000 for the anthracene oil sample and m/z 600-1500 for the creosote oil sample, tailing off to m/z about 5,000. The creosote oil contained significantly less of this high-mass material than the anthracene oil sample, and in both cases, high-mass material was only present in low quantities. The method outlined in the paper appears directly applicable to the characterization of heavier coal and petroleum derived fractions. 44 refs., 14 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Shot-noise-limited optical Faraday polarimetry with enhanced laser noise cancelling

We present a shot-noise-limited measurement of optical Faraday rotations with sub-ten-nanoradian angular sensitivity. This extremely high sensitivity is achieved by using electronic laser noise cancelling and phase sensitive detection. Specially, an electronic laser noise canceller with a common mode rejection ratio of over 100 dB was designed and built for enhanced laser noise cancelling. By measuring the Faraday rotation of ambient air, we demonstrate an angular sensitivity of up to 9.0×10{sup −9} rad/√(Hz), which is limited only by the shot-noise of the photocurrent of the detector. To date, this is the highest angular sensitivity ever reported for Faraday polarimeters in the absence of cavity enhancement. The measured Verdet constant of ambient air, 1.93(3)×10{sup −9}rad/(G cm) at 633 nm wavelength, agrees extremely well with the earlier experiments using high finesse optical cavities. Further, we demonstrate the applications of this sensitive technique in materials science by measuring the Faraday effect of an ultrathin iron film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The hard x-ray nanotomography microscope at the advanced light source

Beamline 11.3.1 at the Advanced Light Source is a tender/hard (6–17 keV) x-ray bend magnet beamline recently re-purposed with a new full-field, nanoscale transmission x-ray microscope. The microscope is designed to image composite and porous materials possessing a submicrometer structure and compositional heterogeneity that determine materials’ performance and geologic behavior. The theoretical and achieved resolutions are 55 and <100 nm, respectively. The microscope is used in tandem with a <25 nm eccentricity rotation stage for high-resolution volume imaging using nanoscale computed tomography. The system also features a novel bipolar illumination condenser for the illumination of an ~100 μm spot of interest on the sample, followed by a phase-type zone plate magnifying objective of ~52 µm field of view and a phase detection ring. The zone plate serves as the system objective and magnifies the sample with projection onto an indirect x-ray detection system, consisting of a polished single crystal CsI(Tl) scintillator and a range of high-quality Plan Fluorite visible light objectives. The objectives project the final visible light image onto a water-cooled CMOS 2048 × 2048-pixel 2 detector. Here, in this paper, we will discuss the salient features of this instrument and describe early results from imaging the internal three-dimensional microstructure and nanostructure of target materials, including fiber-reinforced composites and geomaterials.

47 OTHER INSTRUMENTATION↗

Liquid Argon Time Projection Chamber Trigger Development with MicroBooNE

The Micro Booster Neutrino Experiment (MicroBooNE) is a Liquid Argon Time Projection Chamber (LArTPC) neutrino detector at Fermilab that has been operating since 2015. It aims to perform v-Ar cross-section measurements, explore the low-energy excess reported by the MiniBooNE experiment and perform a combined search for sterile neutrino oscillations as part of three LArTPCs that make up the Short Baseline Neutrino (SBN) Program at Fermilab. Since MicroBooNE is currently in an R&D phase, it offers a unique opportunity for the implementation and testing of TPC-based triggers as R&D towards the Deep Underground Neutrino Experiment (DUNE). One of the technical challenges of DUNE that we aim to address with this study is that of efficient self-triggering of a LArTPC utilizing TPC signal information. This capability will enable searches for rare processes in DUNE, such as neutrino interactions from a potential galactic supernova burst. This talk will describe the MicroBooNE TPC readout system and ongoing R&D efforts to develop and demonstrate TPC-based triggering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗