Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Approach, Technical Success, Complications, and Stent Patency of Sharp Recanalization for the Treatment of Chronic Venous Occlusive Disease: Experience in 123 Patients

Purpose: To report the technical success and complications following sharp recanalization of chronic venous occlusions. Materials and Methods: A total of 123 patients, including 75 (61.0%) men and 48 (39.0%) women, with mean age of 50.5 ± 17.5 years (range 19–90 years), underwent sharp recanalization of chronic venous occlusions. The etiologies of occlusion were chronic deep venous thrombosis (n = 43; 35.0%), prior central venous access (n = 39; 31.7%), indwelling cardiac leads (n = 21; 17.1%), and occluded venous stents (n = 20; 16.3%). The sites of venous occlusion included 59/123 (48.0%) thoracic central veins, 37 (30.1%) non-thoracic central veins, and 27 (22.0%) peripheral veins. Median length of occlusion was 3.2 ± 1.4 cm (range 1.3–10.9 cm). Results: Sharp recanalization was most commonly attempted with transseptal needles in 108/123 (87.8%), with a mean number of 1.2 ± 0.4 crossing devices per patient (range 1–4 devices). Targeting devices included a loop snare (n = 92; 74.8%), partially deployed Wallstent (n = 21; 17.1%), partially deployed Amplatzer vascular plug (n = 8; 6.5%), and an angioplasty balloon (n = 3; 2.4%). Technical success was achieved in 111 (90.2%) patients. There were 3 (2.4%) severe, 1 (0.8%) moderate, and 7 (5.7%) minor adverse events. Severe adverse events included 1 case each of pericardial tamponade, hemothorax, and inferior vena cava filter occlusion. 88 (71.5%) patients had venous stents placed; at the last follow-up examination, 68/86 (79.0%) stents were patent. Conclusion: Sharp recanalization has a high technical success and low rate of adverse events in the recanalization of chronic venous occlusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Fenestration for Branch Vessel Reconnection in Aortic Dissection Using a Novel Diamond-Tipped Chronic Total Occlusion Drilling Device: A Technical Report

Purpose: Aortic dissection is a complex condition with high morbidity and mortality. Endovascular treatments including percutaneous fenestration can be used to manage branch vessel ischaemia or risk of aortic rupture. A variety of techniques for aortic fenestration have been described. We describe the novel use of the TruePath Chronic Total Occlusion (CTO) device for aortic intimal fenestration to achieve side branch reconnection. Materials and Methods: We present three cases of aortic dissection presenting with symptoms of aortic side branch occlusion and end organ malperfusion, treated with aortic fenestration using the TruePath CTO device via trans-brachial and trans-femoral approaches. Results: Technical success was achieved in all three cases. No complications were encountered. Flow was restored in compromised visceral branches. Branches remained patent on follow-up CT angiography over a minimum 2.5-year follow-up period. Conclusion: Percutaneous aortic fenestration techniques enable a minimally invasive approach to treat visceral branch malperfusion associated with aortic dissection. The TruePath CTO device improves the control of the fenestration procedure with the potential to improve efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double-Barreled and Branched Endografting for Thoracoabdominal Aortic Aneurysm: The Hexapus Technique

Objective: To treat thoracoabdominal aortic aneurysm (TAAA), we introduced an alternative “Hexapus” technique by double-barreled and branched endografting. Technique and Result: We established 2 transfemoral and 2 transaxillary access routes first and then deployed two abdominal bifurcated stentgrafts landing at the descending thoracic aorta through transfemoral routes, respectively. Two pairs of parallel stentgrafts were deployed via bilateral transaxillary route from each of contralateral limbs of main body stentgrafts to visceral arteries. Finally, we extended the ipsilateral limbs of main body stentgrafts to bilateral common iliac arteries as distal landings. The creation of six branches (four viscerals and two iliacs) resembles a hexapus. We have executed this Hexapus technique in three patients, and the final angiography during operation and postoperative 12-month image follow-up showed patent visceral branches and no any endoleaks. Conclusion: Our Hexapus technique is feasible in treating TAAA if patient is inoperable or no commercial fenestrated or branched stentgraft is available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type II Endoleak After Endovascular Aortic Aneurysm Repair Using the Endurant Stent Graft System for Abdominal Aortic Aneurysm with Occluded Inferior Mesenteric Artery

Purpose: To evaluate the incidence of type II endoleak (EL-II) and aneurysm enlargement after endovascular aneurysm repair (EVAR) using the Endurant stent graft in patients with abdominal aortic aneurysm (AAA) with occluded inferior mesenteric artery (IMA). Materials and Methods: Between 2012 and 2017, 103 patients who underwent EVAR using the Endurant stent graft for AAA with occluded IMA (50 patients with prophylactic embolized IMA and 53 with spontaneous occluded IMA) were retrospectively reviewed. The incidence of EL-II and aneurysm enlargement was evaluated. Predictive factors for persistent EL-II were evaluated based on patient characteristics, preprocedural anatomical characteristics, intraprocedural details, and postprocedural complications. Results: Incidence rates of early EL-II and persistent EL-II were 6.8% (7/103 patients) and 4.9% (5/103 patients), respectively. Aneurysm enlargement was found in 10 patients (9.7%), including all 5 patients with persistent EL-II, 3 with de novo EL-II, and 2 with no EL-II. The rates of freedom from aneurysm enlargement at 1, 2, and 3 years were 98.7%, 97.0%, and 93.1% for the group without persistent EL-II, and 80.0%, 60.0%, and 20.0% for the group with persistent EL-II (p < 0.001), respectively. The maximum aneurysm diameter (odds ratio (OR), 1.16; 95% confidence interval (CI), 1.01–1.34; p = 0.0362) and the number of patent lumbar arteries (OR, 2.72; 95% CI, 1.07–6.90; p = 0.0357) were predictive of persistent EL-II. Conclusions: The incidence of EL-II after EVAR using the Endurant stent graft for AAA with occluded IMA was low, but most early EL-II persisted and resulted in aneurysm enlargement. Level of Evidence Level 4, Case Series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted Sonic Therapy (RAST) for Noninvasive Hepatic Ablation in a Porcine Model: Mitigation of Body Wall Damage with a Modified Pulse Sequence

Purpose: Robotically assisted sonic therapy (RAST) is a nonthermal, noninvasive ablation method based on histotripsy. Prior animal studies have demonstrated the ability to create hepatic ablation zones at the focal point of an ultrasound therapy transducer; however, these treatments resulted in thermal damage to the body wall within the path of ultrasound energy delivery. The purpose of this study was to evaluate the efficacy and safety of a pulse sequence intended to mitigate prefocal body wall injury. Materials and Methods: Healthy swine (n = 6) underwent hepatic RAST (VortxRx software version 1.0.1.3, HistoSonics, Ann Arbor MI) in the right hepatic lobe. A 3.0 cm spherical ablation zone was prescribed for each. Following treatment, animals underwent MRI which was utilized for ablation zone measurement, evaluation of prefocal injury, and assessment of complications. Each animal was euthanized, underwent necropsy, and the tissue was processed for histopathologic analysis of the ablation zone and any other sites concerning for injury. Results: No prefocal injury was identified by MRI or necropsy in the body wall or tissues overlying the liver. Ablation zones demonstrated uniform cell destruction, were nearly spherical (sphericity index = 0.988), and corresponded closely to the prescribed size (3.0 × 3.1 × 3.4 cm, p = 0.70, 0.36, and 0.01, respectively). Ablation zones were associated with portal vein (n = 3, one occlusive) and hepatic vein thrombosis (n = 4, one occlusive); however, bile ducts remained patent within ablation zones (n = 2). Conclusions: Hepatic RAST performed with a modified ultrasound pulse sequence in a porcine model can mitigate prefocal body wall injuries while maintaining treatment efficacy. Further study of hepatic RAST appears warranted, particularly in tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Treatment Strategy for Primary Budd–Chiari Syndrome with Both Inferior Vena Cava and Hepatic Vein Involvement: Patients from Two Centers in China

Objective: This retrospective study evaluated interventional treatments (recanalization, balloon dilation, and/or stent placement) for Budd–Chiari syndrome (BCS), caused by combined obstruction of the inferior vena cava (IVC) and hepatic veins (HVs). Methods: Before and after interventional therapy, patients with BCS (n = 162; asymptomatic 105.2 ± 103.3 mo; follow-up 15 [6–24] mo) underwent imaging studies (color Doppler ultrasound, CT, or MRI), and inferior vena cavography and manometry. Venous lesions were characterized by occlusion features, and presence of thrombosis and peripheral collateral vessels. Results: One, 2, and 3 main HV occlusions were observed, respectively, in 25 (15.4%), 61 (37.7%), and 76 (46.9%) patients. Eighty-three (51.2%), 98 (60.5%), and 104 (64.2%) patients had, respectively, large accessory HVs, venous collaterals formed between the HVs, or venous communicating branches between the HV and the peritoneal veins. The middle, left, and right HV was patent in 32 (19.8%), 35 (21.6%), and 44 (27.2%) patients. Recanalization of both hepatic and caval occlusions was successful in 96% (51/53) of those attempted; recanalization of IVC occlusion was successful in 97% (106/109). Among 157 patients successfully treated, 146 were cured and 11 showed clinical improvement. Clinical symptoms were relieved in 82.4% after the initial intervention, and 94.2% after the second intervention. Conclusion: Recanalization and balloon angioplasty was effective for the management of BCS with concurrent HV and IVC occlusions. The majority of patients required only IVC recanalization. The outcome of patients treated only by IVC intervention was similar to that of patients given combined HV and IVC intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiphase Microstructure in a Metastability-Assisted Medium Carbon Alloy Steel

A medium carbon alloy steel is processed by austenizing at 900 °C for 30 min, then rapid quenching into a patented quenching liquid and holding at 170 °C for 5 min, finally isothermally holding at 250 °C for different times. The morphology and mechanical properties are performed by using optical microscopy and scanning electron microscopy. A multiphase microstructure characterized by a mixture of lenticular prior martensite (PM), fine needle bainitic ferrite and filmy retained austenite (RA) is obtained. It is found that the PM formed firstly upon quenching can accelerate the subsequent bainitic transformation and promote refinement of multiphase colonies. The results show that an optimum mechanical property of a 4000.9 MPa bending strength and a 2030 MPa tensile strength is achieved at 250 °C for 120 min, which is attributed to the multiphase microstructural characteristics and a high product of the volume fraction of RA and the carbon content of austenite.

36 MATERIALS SCIENCE↗

Bettye Washington Greene: An Industrial Chemist and Inventor Who Lit a Path for Innovation

American civil rights pioneer John Lewis once wrote: “You are a light. You are the light. Never let anyone— any person or any force—dampen, dim or diminish your light.” At a time when the civil rights movement was shedding light on inequalities for African Americans, Dr. Bettye Washington Greene (March 20, 1935 – June 16, 1995) was forging a path that would light the way–figuratively and literally—for generations to come. She was one of the few African American women to earn a Ph.D. in chemistry in the 1960s, an era marked by the passing of the Voting Rights Act of 1965. Washington Greene’s doctoral thesis evaluated light-scattering methods to determine the size of particles, which influences molecular effectiveness, activity, and stability. The fundamental knowledge she provided critically aided the pharmaceutical, catalyst and cosmetics industries [1]. Following her doctoral defense, Bettye went on to become the first African American female employed in a scientific research role at the Dow Chemical Company, where her innovations were awarded three patents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of geometry on columnar to equiaxed transition during electron beam powder bed fusion of IN718

Correlation between spot-melt scan parameters (linear spot-density aka areal energy density), build geometry, and solidification microstructure evolution (columnar vs equiaxed) in a powder bed fusion technology is investigated. It is shown that to maintain the equiaxed solidification microstructure evolution in electron beam powder bed additive manufacturing (AM), the areal energy density per layer needs to be scaled with respect to the 2D cross-sectional area of the layer being melted. Samples with two different cross-sectional areas (40 × 40 mm and 20 × 20 mm) have been fabricated with varying areal energy densities. For a given square cross-section (20 × 20 mm), increasing the areal energy density (4.8 MJ/sq.m to 14.7 MJ/sq.m) transitioned the solidification microstructure from columnar to equiaxed. The observed microstructure data (Electron Back Scattered Diffraction - EBSD) is quantified by calculating the principal component (PC) score using a spatial statistics methodology. The sample with equiaxed grains is found to have a low PC score while the sample with columnar grain had a high PC score. A semi-analytical model is used to simulate the heat transfer and the local solidification conditions as a function of processing parameters (linear spot-density). The result from the heat transfer model is correlated with previously quantified microstructure data. Space-Time analysis of the melt pattern is done and correlated with the observed microstructure. In addition, from the findings, appropriate parameters have been used to additively manufacture a turbine blade with site-specific or hybrid solidification microstructure (traditional fabrication possible via a patented method of localized cold working and heat treatment).

36 MATERIALS SCIENCE↗

Vacuum-assisted extrusion to reduce internal porosity in large-format additive manufacturing

Large-scale 3D printing of polymer composite structures has gained popularity and seen extensive use over the last decade. Much of the research related to improving the mechanical properties of 3D-printed parts has focused on exploring new materials and optimizing print parameters to improve geometric control and minimize voids between printed beads. However, porosity at the microstructural level (within the printed bead) has been much less studied although it is almost universally observed at levels of 4 %-10 % when using fiber reinforced materials. This study introduces a vacuum-assist approach that minimizes internal porosity by removing ambient air from the interstitial space between pellets in the hopper and acts as a negative pressure vent for gases that evolve during the initial stages of single-screw extrusion. Vacuum-assisted extrusion was able to reduce porosity below 2 % across a wide range of processing parameters, moisture content, fiber reinforcements, and printing platforms. Specifically, when printing on a large-format extruder (Strangpresse Model-30), the vacuum-assisted extrusion reduced internal porosity by 35–75 % compared to conventional non-vacuum extrusion, and only pores with length scale > 2 microns are affected. The success of this approach prompted the design of a patent-pending continuous vacuum hopper relevant for large-scale 3D printing on commercial systems.

36 MATERIALS SCIENCE↗

Cycle Design and Optimization of Pressure Swing Adsorption Cycles for Pre-Combustion CO 2 Capture

Novel pressure-swing adsorption (PSA) cycles were developed based on patented TDA AMS- 19 (activated carbon) adsorbent for pre-combustion CO 2 capture in integrated gasi cation combined cycle (IGCC) power plants. A variety of cycles comprising of counter-current blowdown, pressure equalization, steam purge and light product pressurization steps were designed and simulated using an in-house one dimensional detailed model. Full process opti- mization studies were performed for all cycles to evaluate their feasibility for pre-combustion CO 2 capture. The CO 2 purity and recovery Pareto fronts obtained using the multi-objective optimization were used to assess their ability to simultaneously achieve high CO 2 purity (>95%) and recovery (>90%). The cycles that achieved the purity-recovery (95%-90%) requirements were subjected to energy-productivity optimizations under the constraints of CO 2 purity and recovery. Three cycle designs were ranked in terms of lowest energy con- sumption at 95% CO 2 purities and 90% CO 2 recoveries. It was found that a 10-step cycle with three pressure equalization steps achieved a minimum energy consumption of 95.7 kWhe/tonne of CO 2 captured at a productivity of 3.3 mol CO 2 captured/m 3 adsorbent/s.

36 MATERIALS SCIENCE↗

Active interrogation of Special Nuclear Material containers using AmBe quasi-forward biased directional source and PGNAA

Special Nuclear Material (SNM) including 95% 235 U and 239 Pu is capable of being identified by utilizing a quasi-forward directional AmBe source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). HPGe and LaBr 3 detector arrays were used to identify and quantify the peak-to-background and peak-to-total ratios of the associated photon spectra from the SNM encased in a polyethylene shield. The conducted simulations varied the volume of the SNM and neutron source strength in the MCNP data card to conduct an uncertainty analysis. Photopeaks identified include K-shell X-rays from 235 U and 239 Pu, 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peak from the prompt gamma interaction from hydrogen. Relationships between peak-to-total and peak-to-background as a function of SNM and particle history were investigated to aid in the analysis. The capabilities of both detector systems to acquire well resolved photopeak with a 5% relative error or less, with a 1 Ci source activity, and a peak-to-background ratio of 1.15. Finally, this was determined to take 326 s for LaBr 3 and 163 s for HPGe which is comparable to current methods for material detection which take between 100 and 900 s to acquire.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source

Source location of Special Nuclear Material (SNM) encompassing 95% 235 U and 239 Pu is identified by utilizing a directional source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron spectroscopy simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). BC-408, HPGe, LaBr 3 detector arrays were used to identify the location of the SNM using total counts incident on each detector, and PGNAA photopeaks from HPGe and LaBr 3 detector arrays in a polyethylene shield. The conducted simulations varied the volume and location of the SNM in the MCNP input files to observe how the source location method behaved. PGNAA photopeaks used for source identification include 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peaks from the prompt gamma interaction from hydrogen. The capabilities of each detector systems to acquire well resolved photopeaks with a 1% relative error or less, and total relative error for F4 and F8 tallies were less than 0.015% relative error. Source predictions of the SNM with uneven amounts of polyethylene shielding between the source and detectors was observed to overpredict and give invalid source location predictions. Source locations of the SNM with even amounts of polyethylene material between the source and each detector were found to be valid. With a 1 Ci 241 Am source activity, it was determined that 1630 s were needed to obtain the results for each detector system with the quasi-forward directional AmBe source. Coupling source and material identification together would increase acquisition time but would only require one system to determine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of acid responsive genes in the susceptibility of Escherichia coli to ciclopirox

Highlights: • Ciclopirox antibacterial activity was analysed by genome-wide expression profiling. • Ciclopirox affects expression of glutamate-dependent acid resistance pathway genes. • Down-regulation of hns transcription likely increases ciclopirox activity. • Susceptibility to ciclopirox accompanies increased cell size and decreased motility. • The findings identify probable pathways for ciclopirox action against E. coli. Antibiotic resistance poses a huge threat to the effective treatment of bacterial infections. To circumvent the limitations in developing new antibiotics, researchers are attempting to repurpose pre-developed drugs that are known to be safe. Ciclopirox, an off-patent antifungal agent, inhibits the growth of Gram-negative bacteria, and genes involved in galactose metabolism and lipopolysaccharide (LPS) biosynthesis are plausible antibacterial targets for ciclopirox, since their expression levels partially increase susceptibility at restrictive concentrations. In the present study, to identify new target genes involved in the susceptibility of Escherichia coli to ciclopirox, genome-wide mRNA profiling was performed following ciclopirox addition at sublethal concentrations, and glutamate-dependent acid resistance (GDAR) genes were differentially regulated. Additional susceptibility testing, growth analyses and viability assays of GDAR regulatory genes revealed that down-regulation of evgS or hns strongly enhanced susceptibility to ciclopirox. Further microscopy and phenotypic analyses revealed that down-regulation of these genes increased cell size and decreased motility. Our findings could help to maximise the efficacy of ciclopirox against hard-to-treat Gram-negative pathogens.

60 APPLIED LIFE SCIENCES↗

Recent and future developments in pultrusion technology with consideration for curved geometries: A review

Herein this paper examined the current state and future developments in pultrusion with particular emphasis on its application in curved part manufacturing. The relationship between factors such as resin chemistry, fiber characteristics, and die geometry that influences the properties of pultruded product were highlighted. Moreover, the specific challenges associated with pultruding curved parts such as the complexities in achieving uniformity and structural integrity in such geometries were discussed. The review emphasized mold design, process improvement, adaptive control systems for precise resin impregnation and material selection to address these challenges. Additionally, the paper suggests the integration of real-time monitoring and data analytics as ways to enhance quality control during curved parts pultrusion. These advancements will help to overcome challenges specific to curved pultrusion and make the process more efficient. Other manufacturing techniques such as filament winding, thermoforming, pulforming were mentioned as alternatives to curved parts pultrusion. The review also explores pultruded variable curvature processes, highlighting some notable patents and article related to this subject matter. Production of pultruded variable curvature parts was seen as a key driver that can shape the future of pultrusion. Finally, the paper anticipates future trends, with sustainability, customization, integration of advanced materials, and development of techniques for pultrusion of composites parts.

42 ENGINEERING↗

Development of an anti-clogging perforated plate atomizer for a zero liquid discharge humidification-dehumidification desalination system

An anti-clogging perforated plate atomizer is designed for high temperature and salinity applications in a novel solar-powered zero liquid discharge humidification-dehumidification desalination system (US Patent Application US62882953). Herein this paper presents a detailed discussion on its design, and operation. Experiments are performed on seven atomizers to study the effect of design, and operating parameters on spray cone angle, and average droplet diameter. Spray cone angle remains constant with change in air mass flux, and increases with increasing orifice diameter, and manifold diameter. It also increases initially with water mass flow rate, and manifold height, before attaining a constant value. Average droplet diameter increases with increasing water mass flow rate, and decreasing air mass flux, orifice diameter, and manifold diameter. Further, anti-clogging performance of the atomizer is tested with hypersaline water of 100,000 ppm total dissolved solid (NaCl) at elevated temperatures such as air at 175 °C and saline water at 45 °C. Results show no clogging for 2–13 h of operation. Near-complete suppression of atomizer clogging makes our new additively-manufactured perforated plate atomizer an ideal fit for high salinity, and zero liquid discharge humidification-dehumidification desalination systems. Additionally, its open-surface design allows additional surface modifications to further reduce clogging, and enhance self-cleaning characteristics.

47 OTHER INSTRUMENTATION↗

Clinically applicable 53-Gene prognostic assay predicts chemotherapy benefit in gastric cancer: A multicenter study

BACKGROUND:We previously established a 53-gene prognostic signature for overall survival (OS) of gastric cancer patients. This retrospective multi-center study aimed to develop a clinically applicable gene expression detection assay and to investigate the prognostic value of this signature. METHODS:A TCGA gastric adenocarcinoma cohort (TCGA-STAD) was used for comparing 53-gene signature with other gene signatures. A high-throughput mRNA hybridization gene expression assay was developed to quantify the expression of 53-genes in formalin-fixed paraffin-embedded tissues of 540 patients enrolled from three hospitals. 180 patents were randomly selected from two hospitals to build a prognostic prediction model based on the 53-gene signature using leave-p-out (one-third out) cross-validation method together with Cox regression and Kaplan-Meier analysis, and the model was assessed on three validation cohorts. FINDINGS:In the evaluation phase, studies based on TCGA-STAD showed that the 53-gene signature was significantly superior to other three prognostic signatures and was independent of TCGA molecular subtypes and clinical factors. For clinical validation and utility, the prognostic scores were generated using the newly developed assay, which was reliable and sensitive, in 100 sampling training sets and were significantly associated with OS in 100 sampling validation sets. The scores were significantly associated with OS in three independent and combined validation cohorts, and in patients with stages II and III/IV. The multivariate Cox regression demonstrated that the prognostic power of the score was independent of clinical factors, consistent with those findings in the TCGA dataset. Finally, patients with good prognostic scores exhibited significantly a better 5-year OS rate from adjuvant FOLFOX chemotherapy after surgery than from other chemotherapies. INTERPRETATION:The 53-gene prognostic score system is clinically applicable for predicting the OS of patients independent of clinical factors in gastric cancers, which could also be a promising predictive biomarker for FOLFOX regimen. FUNDING:Chinese National Science and Technology, National Natural Science Foundation and Natural Science Foundation of Jiangsu Province.

60 APPLIED LIFE SCIENCES↗