Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTIAL PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Effect of propellant deformation on ignition and combustion processes in solid propellant cracks

A comprehensive theoretical model was formulated to study the development of convective burning in a solid propellant crack which continually deforms due to burning and pressure loading. In the theoretical model, the effect of interrelated structural deformation and combustion processes was taken into account by considering (1) transient, one dimensional mass, momentum, and energy conservation equations in the gas phase; (2) a transient, one dimensional heat conduction equation in the solid phase; and (3) quasi-static deformation of the two dimensional, linear viscoelastic propellant crack caused by pressure loading. Partial closures may generate substantial local pressure peaks along the crack, implying a strong coupling between chamber pressurization, crack combustion, and propellant deformation, especially when the cracks are narrow and the chamber pressurization rates high. The maximum pressure in the crack cavity is generally higher than that in the chamber. The initial flame-spreading process is not affected by propellant deformation.

Kumar, M.↗

The Influence of Smoke Particle Properties and Cabin Characteristics on Smoke Detection in Lunar Gravity

Spacecraft fires pose a threat to the success of future Lunar, Martian, and deep space exploration missions. As NASA plans to return humans to the Moon in the next decade, novel mission requirements will present new fire safety challenges. For example, materials that are fire resistant on Earth are expected to burn under planned habitat conditions (elevated oxygen concentrations and reduced cabin pressure) and partial gravity (0.16g). Optimal smoke detector placement will depend on a combination of buoyant plume velocities, induced by partial gravity, and Environmental Control and Life Support Systems (ECLSS) parameters, including particle filtration rates, supply and return placement within the cabin, and forced air velocities. These ECLSS parameters must also address the need for rapid Lunar dust removal, as Lunar dust exposure poses a risk to crew health and hardware functionality. Here, we present progress toward a computational fluid dynamics model to evaluate smoke transport in a Lunar habitat. Recent work has demonstrated that if air supplies are placed on ceilings and returns on the floor, a buoyant smoke layer at the ceiling may disperse over the order of minutes even under low forced flow conditions. We expand upon these results to examine the influence of different supply and return configurations on smoke plume development. Additionally, we also address differences in the transport of smoke particles and Lunar dust by varying particle parameters like size, density, and shape factor. Finally, we discuss ongoing and future experimental efforts to measure smoke particle properties and transport under partial gravity, elevated oxygen, and reduced pressure conditions.

Claire Fortenberry↗

Metal--Insulator Transition in Bi{sub 2}Sr{sub 2}Cu{sub 1}O{sub 6+d}(Bi-2201) Thin Films

We have studied the influence of disorder induced by oxygen on the normal state resistivity of under doped Bi{sub 2}Sr{sub 2}Cu{sub 1}O{sub 6+d}(Bi-2201) thin films, deposited in situ onto heated SrTiO{sub 3}(100) substrates by using DC magnetron sputtering for an off-stoichiometric target. The compositions and structural characterization for the deposited films were carried by (EDX), (XPS) and X-ray diffraction measurements. The effect of partial oxygen pressure in the sputtering gas on the metal-insulator transition are presented.

36 MATERIALS SCIENCE↗

Design principles for high–pressure force fields: Aqueous TMAO solutions from ambient to kilobar pressures

Accurate force fields are one of the major pillars on which successful molecular dynamics simulations of complex biomolecular processes rest. They have been optimized for ambient conditions, whereas high-pressure simulations become increasingly important in pressure perturbation studies, using pressure as an independent thermodynamic variable. Here, we explore the design of non-polarizable force fields tailored to work well in the realm of kilobar pressures – while avoiding complete reparameterization. Our key is to first compute the pressure-induced electronic and structural response of a solute by combining an integral equation approach to include pressure effects on solvent structure with a quantum-chemical treatment of the solute within the embedded cluster reference interaction site model (EC-RISM) framework. Next, the solute’s response to compression is taken into account by introducing pressure-dependence into selected parameters of a well-established force field. In our proof-of-principle study, the full machinery is applied to N,N,N-trimethylamine-N-oxide (TMAO) in water being a potent osmolyte that counteracts pressure denaturation. EC-RISM theory is shown to describe well the charge redistribution upon compression of TMAO(aq) to 10 kbar, which is then embodied in force field molecular dynamics by pressure-dependent partial charges. The performance of the high pressure force field is assessed by comparing to experimental and ab initio molecular dynamics data. Beyond its broad usefulness for designing non-polarizable force fields for extreme thermodynamic conditions, a good description of the pressure-response of solutions is highly recommended when constructing and validating polarizable force fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Projections of H-mode access and edge pedestal in the SPARC tokamak

In order to inform core performance projections and divertor design, the baseline SPARC tokamak plasma discharge is evaluated for its expected H-mode access, pedestal pressure and edge-localized mode (ELM) characteristics. A clear window for H-mode access is predicted for full field DT plasmas, with the available 25 MW of design auxiliary power. Additional alpha heating is likely needed for H-mode sustainment. Pressure pedestal predictions in the developed H-mode are surveyed using the EPED model. The projected SPARC pedestal would be limited dominantly by peeling modes and may achieve pressures in excess of 0.3 MPa at a density of approximately 3 × 10 20 m -3 . High pedestal pressure is partially enabled by strong equilibrium shaping, which has been increased as part of recent design iterations. Edge-localized modes (ELMs) with >1 MJ of energy are projected, and approaches for reducing the ELM size, and thus the peak energy fluence to divertor surfaces, are under consideration. The high pedestal predicted for SPARC provides ample margin to satisfy its high fusion gain (Q) mission, so that even if ELM mitigation techniques result in a 2x reduction of the pedestal pressure, Q > 2 is still predicted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of flow-induced pressure fluctuations in a Francis turbine operating at the design and partial load regimes-LES simulations

High-fidelity large eddy simulations (LES) were conducted to characterize the spatial and temporal structure of turbulent flows in an industrial-sized Francis turbine while the unit operated at the design point and partial load. A pressure surge with an amplitude of 8% of the turbine head was observed at partial load while the amplitude was<1% at the design point. The vortex rope precession observed in the draft tube correlated to the amplitude and frequency of the pressure surge. Central and peripheral water injections at various volumetric rates were considered to control the flow-induced pressure fluctuations. Central injection at the 4% and 6% flow rates attenuated high amplitude pressure fluctuations by 40% and 75% respectively at partial load. At the same operating conditions, peripheral injections did not have the same desired effect. Although power generation was not changed with water injection at the design point, it was reduced by about 2.5% by central injection and 0.5% by peripheral injection at partial load, showing a water injection mitigation strategy could be applied without any penalty.

Design and partial load regime↗

Massive Pulmonary Embolism: Treatment with the Rotarex Thrombectomy System

This study was designed to evaluate the efficacy and safety of percutaneous mechanical thrombectomy (PMT) for acute massive pulmonary embolism (PE). Fourteen patients (8 men, 6 women) with a mean age of 55.4 (range, 38-71) years with acute massive PE were initially diagnosed by computed tomography (CT) and confirmed by pulmonary angiography. All patients presented with acute PE symptoms and hemodynamic compromise. Each patient was treated with Straub Rotarex thrombectomy device and five patients received additional thrombolysis. Technique success and clinical improvement were achieved in all patients without major complications. The mean pulmonary artery pressure (PAP) decreased from 37.6 {+-} 6.6 to 29 {+-} 6.4 mmHg (P < 0.01) after PMT. Partial arterial pressures of O{sub 2} (PaO{sub 2}) increased from 61.1 {+-} 9.2 to 88 {+-} 5.1 mmHg (P < 0.01). The Miller index was 0.67 {+-} 0.11 and 0.37 {+-} 0.13 (P < 0.01), respectively, before and after PMT (P < 0.01). Eleven patients had no recurrence of PE on a mean follow-up of 28.3 months, whereas the other three patients were lost to follow-up. The preliminary experience in our series suggests that the Straub Rotarex thrombectomy device, which has been utilized in peripheral arteries, also is useful for the treatment of acute massive PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Partial Defect Verification of the Pressurized Water Reactor Spent Fuel Assemblies

The International Atomic Energy Agency (IAEA) has the responsibility to carry out independent inspections of all nuclear material and facilities subject to safeguards agreements in order to verify compliance with non-proliferation commitments. New technologies have been continuously explored by the IAEA and Member States to improve the verification measures to account for declared inventory of nuclear material and detect clandestine diversion and production of nuclear materials. Even with these efforts, a technical safeguards challenge has remained for decades for the case of developing a method in identifying possible diversion of nuclear fuel pins from the Light Water Reactor (LWR) spent fuel assemblies. We had embarked on this challenging task and successfully developed a novel methodology in detecting partial removal of fuel from pressurized water reactor spent fuel assemblies. The methodology uses multiple tiny neutron and gamma detectors in the form of a cluster and a high precision driving system to obtain underwater radiation measurements inside a Pressurized Water Reactor (PWR) spent fuel assembly without any movement of the fuel. The data obtained in such a manner can provide spatial distribution of neutron and gamma flux within a spent fuel assembly. The combined information of gamma and neutron signature is used to produce base signatures and they are principally dependent on the geometry of the detector locations, and exhibit little sensitivity to initial enrichment, burn-up or cooling time. A small variation in the fuel bundle such as a few missing pins changes the shape of the signature to enable detection. This resulted in a breakthrough method which can be used to detect pin diversion without relying on the nuclear power plant operator's declared operation data. Presented are the results of various Monte Carlo simulation studies and experiments from actual commercial PWR spent fuel assemblies.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Experimental Validation of the Methodology for Partial Defect Verification of the Pressurized Water Reactor Spent Fuel Assemblies

A set of controlled experiments and Monte Carlo simulation studies with actual commercial pressurized water reactor (PWR) spent fuel assemblies were performed in order to validate an earlier proposal for partial defect testing of the PWR spent fuel assemblies. The proposed methodology involved insertion of tiny neutron and gamma detectors into the guide tubes of PWR assemblies, measurements and data evaluation. One of the key features of the data evaluation method was the concept of the base signature obtained by normalizing the ratio of gamma to neutron signals at each measurement position. As the base signature is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up, the methodology could be a powerful verification method which does not require operator declared information on the spent fuel. The benchmarking experiments indeed demonstrated that the methodology can be used for partial defect verification of the PWR spent fuel assemblies without operator declared data. The results from the experiments were compared with the simulations and the agreement between the two was well within ten percent. Thus, based on the simulation studies and benchmarking measurements, the methodology developed promises to be a powerful and practical way to detect partial defects that constitute 10% or more of the total active fuel pins. This far exceeds the detection threshold of 50% missing pins from a spent fuel assembly, a threshold defined by the IAEA Safeguards Criteria.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Partial Premixing Effects on the Reacting Jet of a High-Pressure Axially Staged Combustor

The effects of partial premixing on a reacting jet-in-crossflow is investigated in a five atmosphere axially staged combustor at stationary gas turbine relevant conditions. The facility consists of a dump style headend burner that provides a crossflow with a quasi-uniform velocity and temperature profile to the axial stage to isolate the effects of the jet-in-crossflow. The headend burner is run with methane and air at a lean equivalence ratio to match industry emission standards. For this work, the total air to the headend and axial stage is kept constant, and fuel is split between the headend and axial stage to represent different gas turbine loading conditions. For the cases analyzed, the fuel split to the axial stage went up to 25%. The axial stage consists of an optically accessible test section with a coaxial injector that provides variability to how long the methane and air can mix before entering the facility. Three different premixed levels are studied: fully premixed, nonpremixed, and partially premixed. The flow-field characteristics of the reacting jet-in-crossflow are analyzed using particle image velocimetry (PIV), and flame behavior is quantified by employing CH* chemiluminescence. NO measurements are made at the exit of the facility using a Horiba emissions analyzer. Furthermore, two different flames are observed: flames that burn in the leeward recirculation region and flames that burn at the core of the jet.

03 NATURAL GAS↗

Pulmonary function and X-ray

Pulmonary function and chest X-rays of humans exposed to pure oxygen environment at 258 mm Hg pressure

PULMONARY FUNCTION↗

Ultrasonic Apparatus and Technique to Measure Changes in Intracranial Pressure

Changes in intracranial pressure can be measured dynamically and non-invasively by monitoring one or more cerebrospinal fluid pulsatile components. Pulsatile components such as systolic and diastolic blood pressures are partially transferred to the cerebrospinal fluid by way of blood vessels contained in the surrounding brain tissue and membrane. As intracranial pressure varies these cerebrospinal fluid pulsatile components also vary. Thus, intracranial pressure can be dynamically measured. Furthermore, use of acoustics allows the measurement to be completely non-invasive. In the preferred embodiment, phase comparison of a reflected acoustic signal to a reference signal using a constant frequency pulsed phase-locked-loop ultrasonic device allows the pulsatile components to be monitored. Calibrating the device by inducing a known change in intracranial pressure allows conversion to changes in intracranial pressure.

William T Yost↗

Detection of melting by X-ray imaging at high pressure

The occurrence of partial melting at elevated pressure and temperature is documented in real time through measurement of volume strain induced by a fixed temperature change. Here we present the methodology for measuring volume strains to one part in 10{sup −4} for mm{sup 3} sized samples in situ as a function of time during a step in temperature. By calibrating the system for sample thermal expansion at temperatures lower than the solidus, the onset of melting can be detected when the melting volume increase is of comparable size to the thermal expansion induced volume change. We illustrate this technique with a peridotite sample at 1.5 GPa during partial melting. The Re capsule is imaged with a CCD camera at 20 frames/s. Temperature steps of 100 K induce volume strains that triple with melting. The analysis relies on image comparison for strain determination and the thermal inertia of the sample is clearly seen in the time history of the volume strain. Coupled with a thermodynamic model of the melting, we infer that we identify melting with 2 vol.% melting.

36 MATERIALS SCIENCE↗