Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Measurement and Modeling of Blocking Contacts for Cadmium Telluride Gamma Ray Detectors

Gamma ray detectors are important in national security applications, medicine, and astronomy. Semiconductor materials with high density and atomic number, such as Cadmium Telluride (CdTe), offer a small device footprint, but their performance is limited by noise at room temperature; however, improved device design can decrease detector noise by reducing leakage current. This thesis characterizes and models two unique Schottky devices: one with an argon ion sputter etch before Schottky contact deposition and one without. Analysis of current versus voltage characteristics shows that thermionic emission alone does not describe these devices. This analysis points to reverse bias generation current or leakage through an inhomogeneous barrier. Modeling the devices in reverse bias with thermionic field emission and a leaky Schottky barrier yields good agreement with measurements. Also numerical modeling with a finite-element physics-based simulator suggests that reverse bias current is a combination of thermionic emission and generation. This thesis proposes further experiments to determine the correct model for reverse bias conduction. Understanding conduction mechanisms in these devices will help develop more reproducible contacts, reduce leakage current, and ultimately improve detector performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Droplet Entrainment in Steam Supply System of Water-Cooled Small Modular Reactors: Experiment and Modeling Approaches

Droplet entrainment in steam-flow is a prominent phenomenon that needs adequate safety and risk analysis of postulated transient and accident scenarios—including experimental investigation and representative modeling and simulation (M&S)—for small modular reactor (SMR) system design and demonstration. This study identifies knowledge gaps by evaluating experimental and computational fluid dynamics modeling approaches to support early-stage reactor system design, testing, and model evaluation. Previous studies reported in the literature for steam-flow entrainment primarily focused on gigawatt capacity pressurized water reactor (PWR) systems. However, entrainment phenomena are even more prominent for PWR-type SMRs due to their more compact integrated designs, which need further research and development. To fill the research gaps, this study provides insight by specifying the phenomena of interest by leveraging the lessons learned from past research, adopting advanced M&S techniques and advanced instrumentation and control. The findings and recommendations are applicable for evaluating steam-flow entrainment models and for designing integral effect test and separate effect test facilities for gaining reactor design approvals.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Traveling Wave Tube (TVT) RF Power Combining Demonstration for use in the Jupiter Icy Moons Orbiter (JIMO)

The Jupiter Icy Moons Orbiter (JIMO) is set to launch between the years 2012 and 2015. It will possibly utilize a nuclear reactor power source and ion engines as it travels to the moons of Jupiter. The nuclear reactor will produce hundreds of kilowatts of power for propulsion, communication and various scientific instruments. Hence, the RF amplification devices aboard will be able to operate at a higher power level and data rate. The initial plan for the communications system is for an output of 1000 watts of RF power, a data rate of at least 10 megabits a second, and a frequency of 32 GHz. A higher data rate would be ideal to fully utilize the instruments aboard JIMO. At NASA Glenn, one of our roles in the JIMO project is to demonstrate RF power combining using multiple traveling wave tubes (TWT). In order for the power of separate TWT s to be combined, the RF output waves from each must be in-phase and have the same amplitude. Since different tubes act differently, we had to characterize each tube using a Network Analyzer. We took frequency sweeps and power sweeps to characterize each tube to ensure that they will behave similarly under the same conditions. The 200 watt Dornier tubes had been optimized to run at a lower power level (120 watts) for their extensive use in the ACTS program, so we also had to experiment with adjusting the voltage settings on several internal components (helix, anode, collector) of the tubes to reach the full 200 watt potential. from the ACTS program. Phase shifters and power attenuators were placed in the waveguide circuit at the inputs to the tubes so that adjustments could be made individually to match them exactly. A magic tee was used to route and combine the amplified electromagnetic RF waves on the tube output side. The demonstration of 200 watts of combined power was successful with efficiencies greater than 90% over a 500 MHz bandwidth. The next step will be to demonstrate the use of three amplifiers using two magic tees by adding a 200 watt Dornier tube to the Varian and Logimetrics combined setup for a total of 400 watts. After that we will use two 200 watt Dorniers for 400 watts and eventually four 200 watt Dornier tubes to demonstrate 800 watts. After demonstrating the success of power combining, we will need to verify the integrity of a modulated signal sent through the combined tubes. The purpose will be to see what effects separating and recombining will have on the modulated signal and also what effect it will have on combining efficiency. A Bit Error Rate (BER) will be determined by a Bit Error Rate Tester (BERT) by comparing the random information it transmits to what it receives back. The process began with two 100 watt tubes, a Varian and a Logimetrics, salvaged

Downey, Joseph A.↗

Radiochemistry as a (rho)R Diagnostic with the RAGS Gas Collection System

Radiochemical diagnostic techniques such as gas-phase capsule debris analysis may prove to be successful methods for establishing the success or failure of ignition experiments at the National Ignition Facility (NIF). Samples in the gas phase offer the most direct method of collection by simply pumping out the large target chamber following a NIF shot. The target capsules will be prepared with dopants which will produce radioactive noble gas isotopes upon activation with neutrons. We have designed and constructed the Radchem Apparatus for Gas Sampling (RAGS) in order to collect post-shot gaseous samples for NIF capsule diagnostics. The design of RAGS incorporates multiple stages intended to purify, transfer, and count the radioactive decays from gaseous products synthesized in NIF experiments. At the moment the dopant of choice is {sup 124}Xe, which will undergo (n,{gamma}) and (n, 2n) reactions to produce {sup 125}Xe and {sup 123}Xe. The half-lives of each are on the order of multiple hours and are suitable for long-term gamma-counting. These isotopes and the rest of the gases evolved in a NIF shot will be drawn through the NIF turbo pumps, past the temporarily shuttered cryo pumps (to aid our collection efficiency), and towards the first main portion of the RAGS system: the pre-cleaner. The pre-cleaner will consist of a water removal system, a series of heated getter cartridges to remove most other impurities such as N{sub 2}, O{sub 2}, CO{sub 2}, etc., and a residual gas analyzer (RGA) to monitor vacuum quality. The noble gases will flow through the precleaner and into the second stage of the system: the cryo collector. This cryo collector consists of a main cryo head for noble gas collection which will operate for approximately five minutes post-shot. Afterwards a valve will close and isolate the pre-cleaner, while the cryo head warms to release the Xe gas to one of two locations - either a second cryo station for in-situ gamma counting, or to a small cooled gas bottle for removal and counting. Additional capabilities of the RAGS system include a noble gas calibration apparatus attached to the NIF target chamber, which will be operated hours pre-shot to determine collection efficiency through the whole RAGS system via the signal detected from the RGA. Also it is possible there will be the addition of a helium puff system to drive the Xe through the pre-cleaner and collection stations. It is also likely that multiple cryo collection stations will be built into the system in the future to fractionate and collect other noble gases such as Kr, Ar, and possibly Ne. A prototype pre-cleaner has been built at Lawrence Berkeley National Laboratory (LBNL) and is in the testing phases. The information learned in this testing will help collaborators at Sandia National Laboratory that are building and delivering the systems that will be deployed at NIF. The LBNL testing so far has demonstrated that radioactive fission gases can be flowed through the system with and without carrier gases of air and/or He, and the activity can be collected on an activated charcoal sample. Further testing in the upcoming months will hopefully yield more information about any presence of Xe in the water removed from the system, and commissioning of a small cryo cooler as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Breakthrough: Better Fiber for Better Products

Researchers at Idaho National Laboratory have developed a cost-effective method for the continuous production of alpha silicon carbide fiber. The exceptionally strong, lightweight fiber could enable significant performance improvements in many everyday products.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Application of a Triple Bubbler System in Molten Salt for Accurate Mass and Volume Determination

Ongoing testing of the triple bubbler system has been applied to molten salt systems. The instrumentation was developed at Idaho National Laboratory for continuous monitoring of special nuclear materials in molten salt; and the instrument utilizes three dip tubes for determining the mass and volume of a liquid in a vessel. This paper will discuss the important design criteria of the bubbler probe for molten salt systems; and will describe lessons learned from using the system in a molten salt environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The impact assessment of eccentric installation and roughness change in piping on the orifice flow measurement

In orifice flowmeters used in nuclear power plants, requirements for the inner surface roughness of upstream piping and eccentric installation exist depending on certain standards. If these cannot be satisfied based on the installation condition, an appropriate error margin must be considered, although this remains to be clarified. In this research, quantitative data concerning the relative error of orifice flowmeters were obtained during experiments with the parameters of the inner surface roughness of upstream piping and the installation eccentricity of the orifice hole. The maximum Reynolds number of the experimental facility is about 1.6x10{sup 6}. In orifice flowmeters, the flow rate is calculated based on the differential pressure between upstream and downstream orifices and the peculiar discharge coefficient C. The latter value shows an upward trend with increasing roughness of piping, while change of 0.3% of C was observed in terms of roughness (case 2), which approaches the limits of the JIS standard. With significant roughness (Case 3) that exceeds five times the JIS standard, C is shown to have increased by about 1%. No influence was observed by varying the direction of eccentric installation, hence this was fixed and the amount of eccentricity was considered. Change in C of about 0.25% was observed when around twice the standard level of eccentricity was applied. The error margin data under conditions exceeding the JIS standard for the orifice flowmeter was obtained. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of rolling motion on critical heat flux for subcooled flow boiling in vertical tube

This paper presents defining characteristics of the critical heat flux (CHF) for the boiling of R-134a in vertical tube operation under rolling motion in marine reactor. It is important to predict CHF of marine reactor having the rolling motion in order to increase the safety of the reactor. Marine Reactor Moving Simulator (MARMS) tests are conducted to measure the critical heat flux using R-134a flowing upward in a uniformly heated vertical tube under rolling motion. MARMS was rotated by motor and mechanical power transmission gear. The CHF tests were performed in a 9.5 mm I.D. test section with heated length of 1 m. Mass fluxes range from 285 to 1300 kg m{sup -2}s{sup -1}, inlet subcooling from 3 to 38 deg. C and outlet pressures from 13 to 24 bar. Amplitudes of rolling range from 15 to 40 degrees and periods from 6 to 12 sec. To convert the test conditions of CHF test using R-134a in water, Katto's fluid-to-fluid modeling was used in present investigation. A CHF correlation is presented which accounts for the effects of pressure, mass flux, inlet subcooling and rolling angle over all conditions tested. Unlike existing transient CHF experiments, CHF ratio of certain mass flux and pressure are different in rolling motion. For the mass fluxes below 500 kg m{sup -2}s{sup -1} at 13, 16 (region of relative low mass flux), CHF ratio was decreased but was increased above that mass flux (region of relative high mass flux). Moreover, CHF tend to enhance in entire mass flux at 24 bar. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of porous medium on the high cycle temperature fluctuations in a mixing tee

Temperature fluctuations occur in the region where hot and cold fluids mix turbulently in the nuclear power plants. Temperature fluctuations cause thermal fatigue of piping systems. In the design of generation IV nuclear power plants, supercritical fluids are supposed to be used widely. This paper investigated the thermal striping phenomenon caused by the turbulent mixing in a supercritical water Tee. There are two key issues in the study of thermal striping phenomenon: One is to find the region which experiences the peak temperature fluctuation; the other is how to attenuate it. Porous media was used to attenuate the temperature fluctuations in this paper. The results show that porous media with proper parameters in a tee can reduce the temperature fluctuations magnificently. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cross flow characteristics in a three fuel assemblies

To evaluate the reactor thermal margin of APR+, reactor core flow distribution including both axial and lateral directional hydraulic resistances of fuel assemblies should be known. 3-Ch cross flow test facility has been constructed with three full-size fuel assemblies to investigate the cross flow characteristics. Performance tests have been performed. The axial and lateral directional hydraulic resistances of fuel assemblies have been measured. The test results have been compared to the CFD calculation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Monitoring Systems for the Characterisation of Nuclear Fuel and Waste - Methodology and Applications - 12055

The most characteristic behaviour of nuclear fuel or waste contaminated by fission material or isotopes resulting from fissile processes is the emission of neutrons. At the same time because of the high penetration of the material by neutrons, they are an ideal probe for measurement by non-destructive assay. The detection and data analysis in this case is quite different compared to methods using gamma measuring techniques. Neutron detection monitors have been in routine operation for a long time, showing their excellent detection capabilities. The neutron monitors designed for different applications have demonstrated their capabilities during daily operation in the field of burned up fuel elements and for nuclear waste with alpha activity. Lately the data analysis was refined and the quality of the results was improved by using MCNP calculations. Last but not least the layout and the calibration of neutron monitors are nowadays unfeasible without support by MCNP simulations. In the field of non-destructive assay the neutron monitors are undisputed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commissioning and Operation of a Robotic Arm for Waste Retrieval at Trawsfynydd NPP, North Wales - 12091

Trawsfynydd is one of the UK's first generation Magnox nuclear power plants. It started operation in 1965 and ceased generation in 1991. Before the site can enter the 'care and maintenance' phase a number of wet and dry waste stores around the site must be emptied and their contents made safe. Wet wastes include sludges and resins produced during the operating life of the NPP. The sludges and resins are stored in a number of different tanks that vary significantly in terms of size, shape, internal features and access. A dexterous long reach manipulator arm has been designed and built to facilitate tank clearance. Commissioning of the arm was carried out in parallel with Factory Acceptance Testing (FAT) at the manufacturer's site in Colorado, USA. In addition to basic functional testing this work included a full range of task based testing to ensure that the arm, tools, control system and support equipment were thoroughly exercised in representative conditions. Trawsfynydd is one of the lead sites in the UK's program for nuclear plant decommissioning. As such the lessons learned, both in terms of technology and process, will be applicable across the remainder of the fleet. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗