Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROWAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Surface Melting Over the Greenland Ice Sheet Derived From Enhanced Resolution Passive Microwave Brightness Temperatures (1979–2019)

Surface melting is a major component of the Greenland ice sheet surface mass balance, and it affects sea level rise through direct runoff and the modulation of ice dynamics and hydrological processes, supraglacially, englacially and subglacially. Passive microwave (PMW) brightness temperature observations are of paramount importance in studying the spatial and temporal evolution of surface melting due to their long temporal coverage (1979–present) and high temporal resolution (daily). However, a major limitation of PMW datasets has been the relatively coarse spatial resolution, which has historically been of the order of tens of kilometers. Here, we use a newly released PMW dataset (37 GHz, horizontal polarization) made available through a NASA “Making Earth System Data Records for Use in Research Environments” (MeASUREs) program to study the spatiotemporal evolution of surface melting over the Greenland ice sheet at an enhanced spatial resolution of 3.125 km. We assess the outputs of different detection algorithms using data collected by automatic weather stations (AWSs) and the outputs of the Modèle Atmosphérique Régional (MAR) regional climate model. We found that sporadic melting is well captured using a dynamic algorithm based on the outputs of the Microwave Emission Model of Layered Snowpack (MEMLS), whereas a fixed threshold of 245 K is capable of detecting persistent melt. Our results indicate that, during the reference period from 1979 to 2019 (from 1988 to 2019), surface melting over the ice sheet increased in terms of both duration, up to 4.5 (2.9) d per decade, and extension, up to 6.9 % (3.6 %) of the entire ice sheet surface extent per decade, according to the MEMLS algorithm. Furthermore, the melting season started up to 4.0 (2.5) d earlier and ended 7.0 (3.9) d later per decade. We also explored the information content of the enhanced-resolution dataset with respect to the one at 25 km and MAR outputs using a semi-variogram approach. We found that the enhanced product is more sensitive to local-scale processes, thereby confirming the potential of this new enhanced product for monitoring surface melting over Greenland at a higher spatial resolution than the historical products and for monitoring its impact on sea level rise. This offers the opportunity to improve our understanding of the processes driving melting, to validate modeled melt extent at high resolution and, potentially, to assimilate these data in climate models.

Surface melting↗

Microwave Radiometer RFI Detection Using Deep Learning

Radio frequency interference (RFI) is a risk for microwave radiometers due to their requirement of very high sensitivity. The Soil Moisture Active Passive (SMAP) mission has an aggressive approach to RFI detection and filtering using dedicated spaceflight hardware and ground processing software. As more sensors push to observe at larger bandwidths in unprotected or shared spectrum, RFI detection continues to be essential. This article presents a deep learning approach to RFI detection using SMAP spectrogram data as input images. The study utilizes the benefits of transfer learning to evaluate the viability of this method for RFI detection in microwave radiometers. The well-known pretrained convolutional neural networks, AlexNet, GoogleNet, and ResNet-101 were investigated. ResNet-101 provided the highest accuracy with respect to validation data (99%), while AlexNet exhibited the highest agreement with SMAP detection (92%).

Microwave radiometry↗

The Fourth Stokes Parameter for Geolocation in Passive Microwave Remote Sensing from Space

Polarimetric microwave radiometers such as SMAP are capable of measuring the fourth Stokes parameter in brightness temperature over the Earth surface. The value of this parameter is normally small but exhibits sharp spikes when the scene includes large differences in emission from the surface, such occur at land/water boundaries. In this manuscript, it is shown that these spikes can be used to accurately locate coastlines with potential application to geolocation in passive microwave remote sensing from space. Examples are presented using the L-band radiometer on SMAP, first with theory using calculations with the SMAP antenna pattern and orbit and then with SMAP measurements of the fourth Stokes parameter over Madagascar. Using the SMAP data, the coastline is located with a standard deviation less than 2 km. The results are consistent with the conventional approach used for geolocation of the SMAP radiometer footprint.

Passive Microwave Remote Sensing↗

A Comprehensive Machine Learning Study to Classify Precipitation Type over Land from Global Precipitation Measurement Microwave Imager (GPM-GMI) Measurements

Precipitation type is a key parameter used for better retrieval of precipitation characteristics as well as to understand the cloud–convection–precipitation coupling processes. Ice crystals and water droplets inherently exhibit different characteristics in different precipitation regimes (e.g., convection, stratiform), which reflect on satellite remote sensing measurements that help us distinguish them. The Global Precipitation Measurement (GPM) Core Observatory’s microwave imager (GMI) and dual-frequency precipitation radar (DPR) together provide ample information on global precipitation characteristics. As an active sensor, the DPR provides an accurate precipitation type assignment, while passive sensors such as the GMI are traditionally only used for empirical understanding of precipitation regimes. Using collocated precipitation type flags from the DPR as the “truth”, this paper employs machine learning (ML) models to train and test the predictability and accuracy of using passive GMI-only observations together with ancillary information from a reanalysis and GMI surface emissivity retrieval products. Out of six ML models, four simple ones (support vector machine, neural network, random forest, and gradient boosting) and the 1-D convolutional neural network (CNN) model are identified to produce 90–94% prediction accuracy globally for five types of precipitation (convective, stratiform, mixture, no precipitation, and other precipitation), which is much more robust than previous similar effort. One novelty of this work is to introduce data augmentation (subsampling and bootstrapping) to handle extremely unbalanced samples in each category. A careful evaluation of the impact matrices demonstrates that the polarization difference (PD), brightness temperature (Tc) and surface emissivity at high-frequency channels dominate the decision process, which is consistent with the physical understanding of polarized microwave radiative transfer over different surface types, as well as in snow and liquid clouds with different microphysical properties. Furthermore, the view-angle dependency artifact that the DPR’s precipitation flag bears with does not propagate into the conical-viewing GMI retrievals. This work provides a new and promising way for future physics-based ML retrieval algorithm development.

machine learning/artificial intelligence↗

Flood Monitoring Using Enhanced Resolution Passive Microwave Data: A Test Case Over Bangladesh

Monitoring floods is a major issue in water resources management and risk mitigation, especially in the Global South. Optical and radar observations, even providing a fine spatial resolution, are still limited by cloud cover interaction or insufficient temporal resolution. On the other hand, passive microwave (PMW) sensors collect information on a daily frequency with minor cloud cover interaction, but they have been historically limited in terms of spatial resolution. Here, we evaluate the capability of an enhanced spatial resolution PMW dataset (3.125 km) in monitoring spatio-temporal evolution of flood events, focusing on a major flood event that occurred in October 2005 in Bangladesh. We apply an algorithm aimed to remove the seasonal variability of surface temperature from the PMW timeseries, exploiting the difference in emissivity between dry and water-covered pixels. We assess the capability of the algorithm in capturing flood evolution and extension through the comparison with quantities obtained from optical data collected by the Moderate Resolution Imaging Spectroradiometer (MODIS) and water level measurements. We also compare the enhanced product with the historical coarser resolution dataset by means of a variogram-based analysis to evaluate the improvements in terms of spatial representation. Finally, we evaluate the possibility to extract the water fraction within a single pixel by using an Advanced Microwave Scanning Radiometer—Earth Observing System (AMSR-E) emissivity dataset and compare the estimates with MODIS-derived water fractions. Our results show that the enhanced PMW product outperforms the coarser one when compared to flood mapped from optical data based on information content, indicating that it is possible to integrate such a product into the mapping of floods at a global scale on a daily basis.

flood detection↗

A Comparison of Passive Microwave Emission Models for Estimating Brightness Temperature at L- and P-band Under Bare and Vegetated Soil Conditions

P-band radiometry has been demonstrated to have a deeper sensing depth than at L-band, making the consideration of multi-layer microwave interactions necessary. Additionally, the scattering and phase interference effects are different at P-band, requiring a re-consideration of the need for coherent models. However, the impact remains to be clarified, and understanding the validity and limitations of these models at both L-band and P-band is crucial for their refinement and application. Therefore, two general categories of microwave emission models, including two stratified coherent models (Njoku and Wilhite) and four incoherent models (conventional tau-omega model and three multi-layer models being zero-order, first-order, and incoherent solution), were intercompared for the first time on the same dataset. This evaluation utilized observations of L-band and P-band radiometry under different land cover conditions from a tower-based experiment in Victoria, Australia. Model estimations of brightness temperature (TB) were consistent with measurements, with the lowest root mean square error (RMSE) at P-band V-polarization under corn (2 K) and the highest RMSE at L-band H-polarization under bare soil (13 K). Coherent models performed slightly better than incoherent models under bare soil (3 K less RMSE), while the opposite was true under vegetated soil conditions (1 K less RMSE). Coherent and incoherent models showed maximum differences (3 K at P-band, 2 K at L-band), correlating strongly with soil moisture variations at 0-10 cm. Findings suggest that coherent and incoherent models perform similarly; thus, incoherent models may be preferable for estimating TB at L- and P-band due to reduced computational complexity.

Soil moisture profile↗

The West-Coast Hyperspectral Microwave Sensor Intensive Experiment (WHyMSIE): A Prototype for A PBL Mission of Missions

We present an overview of the 2024 West-Coast Hyperspectral Microwave Sensor Intensive Experiment(WHyMSIE). WHyMSIE is a joint NASA-NOAA multi-sensor airborne experiment, embracing passive and active sensors from the Program of Record (PoR) along with novel technology funded through the NASA ESTO Instrument Incubation Program. At the core of this effort is the demonstration of the Conical Scanning Millimeter-wave Imaging Radiometer Hyperspectral (CoSMIR-H) instrument, a PBL DSI funded effort to develop hyperspectral sounding capability in the thermal microwave domain finalized to improved temperature and water vapor soundings in the Earth’s Planetary Boundary Layer (PBL). An overview of the field campaign design, instrument payload and validation plan is presented here.

Planetary Boundary Layer↗

Ground-Based Microwave Measurements of ClO and O3 Over Scott Base, Antarctica

We present measurements from a new microwave instrument that has been deployed at Scott Base, Antarctica, primarily to measure ClO. The new instrument allows for the extension of the time series of lower stratospheric ClO measurements begun in 1996 at this site, while some of the technical improvements offer the possibility of making additional measurements. We show measurements of ClO and O 3 in both the upper and lower stratosphere near both the fall and spring equinox and document the diurnal variations of these measurements throughout the season. The ground-based measurements are compared with Aura Microwave Limb Sounder (MLS) measurements, which are available twice per day, and with a NASA Goddard 2D model (GSFC2D) simulation. We show that, in agreement with the GSFC2D model diurnal variations, upper stratospheric ClO mixing ratios gradually increase throughout the daylight hours, while in the lower stratospheric austral spring, when heterogeneous chemistry associated with polar stratospheric clouds occurs, daily maximum ClO mixing ratios of near 2 ppbv occur near noon. We also show measurements of stratospheric O 3 , primarily in the upper stratosphere, which, while exhibiting a low bias of ∼15%–20% relative to Aura MLS, show temporal variations in good agreement with MLS.

stratospheric ozone↗

The Hyperspectral Microwave Photonic Instrument (HyMPI) and its NEDT Performance

This work presents an overview of a hyperspectral microwave-photonic spectrometer and demonstrates the system end-to-end noise equivalent delta temperature (NEDT) performance. The system aims at augmenting the remote sensing capability from space, with a focus on the Earth’s planetary boundary layer (PBL) thermal microwave (MW) spectral region (0-200 GHz). Combining a Photonic Integrated Circuit (PIC) channelizer and an application-specific integrated circuit (ASIC) spectrometer, the PIC & ASIC (PICASIC) module is capable of processing 40 GHz spectra at hyperspectral (4 MHz) resolution. The photonic technology is agnostic to the spectral region and multiple photonic modules can cover the entire 200 GHz spectrum. Measured results of the end-to-end system NEDT agree with predicted values confirming that the NEDT is primarily dominated by the noise figure of the MW front-end, with the optical link adding no significant noise. The data also demonstrate that a single module enables simultaneous super- and hyper-spectral resolution channel analysis across a 40 GHz range.

spectrometer↗

Differential Resistance of Two Dimensional Electron Systems Subject to Microwave Radiation

We present the expression for differential resistance of a disordered two-dimensional electron gas placed in a perpendicular magnetic field and subject to microwave irradiation. We demonstrate that in strong dc electric fields the current oscillates as a function of the strength of the applied constant electric field. We demonstrate that the amplitude of oscillations of the differential resistivity is characterized by the back-scattering rate off disorder. We argue that the dominant contribution to the non-linearity in strong electric fields originates from the modification of electron scattering off disorder by electric fields, or so-called 'displacement' mechanism. The non-equilibrium mechanism, which is related to modification of electron distribution function by electric fields turns out to be inefficient in strong electric fields, although it describes current in weak electric fields. We further analyze the positions of maxima and minima of the differential resistance as a function of the applied electric field and frequency of microwave radiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SLAC All Access: Vacuum Microwave Device Department

The Vacuum Microwave Device Department (VMDD) builds the devices that make SLAC's particle accelerators go. These devices, called klystrons, generate intense waves of microwave energy that rocket subatomic particles up to nearly the speed of light.

43 PARTICLE ACCELERATORS↗

Printed Microwave Connector

This paper describes the development of a printed, planar microwave connector operating from 1-7 GHz. The connector, which is based on a Grounded Coplanar Waveguide (GCPW) transmission line structure, is fabricated using 3D-printed thermoplastic material (PEEK) and conductive nanoparticle silver ink. Electromagnetic models were established to provide guidance on design tradeoffs and their impact on microwave performance. New mechanical designs were also developed to provide accurate alignment and robust connection of the two halves of the planar connector structure. Initial connector prototypes were fabricated to validate the new planar design using conventional double-sided copper laminates (Isola MT40). The designs were then implemented in an all-printed version of the connector. Electromagnetic models of the printed connectors were developed using the measured dielectric properties of printed PEEK. The insertion loss of the printed connectors was measured to be less than 1.7dB across the band.

Microwave Connector, printed electronics, additive↗

PRINTED, PLANAR MICROWAVE CONNECTOR WITH MULTIPLE SIGNAL LINES

Microwave connectors with a planar geometry have been demonstrated using additive manufacturing techniques. This planar form factor is expected to enable connectors to be integrated directly with other components onto a printed circuit board. The connectors were developed with multiple signal lines that will increase the density of signal connections to PCBs, eliminating the physical constraints of single-signal COTS microwave connectors. This work developed electromagnetic models (using Ansys HFSS) of these planar connectors to predict performance and optimize connector design. Materials and printing processes were developed to fabricate the connectors based on high-temperature PEEK thermoplastics. The multiple signal connectors were designed to operate over the 1-6GHz band and are built upon the single signal printed planar geometry connector introduced in a previous paper [1].

Additive Manufacturing↗

Microwave-absorbing properties of Co-filled carbon nanotubes

Co-filled carbon nanotubes composites were synthesized via using a simple and efficient wet chemistry solution method. The samples were characterized by transmission electron microscopy. Microwave-absorbing properties were investigated by measuring complex permittivity and complex permeability of the absorber in a frequency range of 2-18 GHz. The reflection loss (R.L.), matching frequency (f{sub m}) and matching thickness (d{sub m}) were calculated using the theory of the absorbing wall. The electromagnetic properties and microwave-absorbing characteristics effects of the modified carbon nanotubes by the encapsulation of metal Co were investigated. A matching thickness is found corresponding to a matching frequency. The maximum reflection loss is about -39.32 dB and the bandwidth corresponding to the reflection loss below -10 dB is 3.47 GHz. With increasing thickness, the maximum reflection loss shifts to lower frequency.

36 MATERIALS SCIENCE↗

Iron hydroxyl phosphate microspheres: Microwave-solvothermal ionic liquid synthesis, morphology control, and photoluminescent properties

A variety of iron hydroxyl phosphate (NH{sub 4}Fe{sub 2}(PO{sub 4}){sub 2}OH.2H{sub 2}O) nanostructures such as solid microspheres, microspheres with the core in the hollow shell, and double-shelled hollow microspheres were synthesized by a simple one-step microwave-solvothermal ionic liquid method. The effects of the experimental parameters on the morphology and crystal phase of the resultant materials were investigated. Structural dependent photoluminescence was observed from the double-shelled hollow microspheres and the underlying mechanisms were discussed. - Graphical abstract: A variety of iron hydroxyl phosphate (NH{sub 4}Fe{sub 2}(PO{sub 4}){sub 2}OH.2H{sub 2}O) nanostructures were synthesized by a simple one-step microwave-solvothermal ionic liquid method. Structural dependent photoluminescence was observed from the double-shelled hollow microspheres.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Calibrating ground‐based microwave radiometers: Uncertainty and drifts

Abstract The quality of microwave radiometer (MWR) calibrations, including both the absolute radiometric accuracy and the spectral consistency, determines the accuracy of geophysical retrievals. The Microwave Radiometer Calibration Experiment (MiRaCalE) was conducted to evaluate the performance of MWR calibration techniques, especially of the so‐called Tipping Curve Calibrations (TCC) and Liquid Nitrogen Calibrations (LN2cal), by repeatedly calibrating a fourth‐generation Humidity and Temperature Profiler (HATPRO‐G4) that measures downwelling radiance between 20 GHz and 60 GHz. MiRaCalE revealed two major points to improve MWR calibrations: (i) the necessary repetition frequency for MWR calibration techniques to correct drifts, which ensures stable long‐term measurements; and (ii) the spectral consistency of control measurements of a well known reference is useful to estimate calibration accuracy. Besides, we determined the accuracy of the HATPRO's liquid nitrogen‐cooled blackbody's temperature. TCCs and LN2cals were found to agree within 0.5 K when observing the liquid nitrogen‐cooled blackbody with a physical temperature of 77 K. This agreement of two different calibration techniques suggests that the brightness temperature of the LN2 cooled blackbody is accurate within at least 0.5 K, which is a significant reduction of the uncertainties that have been assumed to vary between 0.6 K and 1.5 K when calibrating the HATPRO‐G4. The error propagation of both techniques was found to behave almost linearly, leading to maximum uncertainties of 0.7 K when observing a scene that is associated with a brightness temperature of 15 K.

Küchler, N.↗

Development of MKIDs for Measurement of the Cosmic Microwave Background with the South Pole Telescope

We present details of the design, simulation, and initial test results of prototype detectors for the fourth-generation receiver of the South Pole Telescope (SPT). Optimized for the detection of key secondary anisotropies of the cosmic microwave background (CMB), SPT-3G+ will measure the temperature and polarization of the mm/sub-mm sky at 220, 285, and 345 GHz, beyond the peak of the CMB blackbody spectrum. The SPT-3G+ focal plane will be populated with microwave kinetic inductance detectors (MKIDs), allowing for significantly increased detector density with reduced cryogenic complexity. We present simulation-backed designs for single-color dual-polarization MKID pixels at each SPT-3G+ observation frequency. We further describe design choices made to promote resonator quality and uniformity, enabling us to maximize the available readout bandwidth. We also discuss aspects of the fabrication process that enable rapid production of these devices and present an initial dark characterization of a series of prototype devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Superconducting Microwave Properties of Aluminum Manganese

A microwave kinetic inductance detector (MKID) is a superconducting pair breaking detector that offers a number of unique advantages for realizing large-format arrays of ultra-sensitive detectors, such as inherent multiplexibility and relative ease of fabrication. With the detection threshold being set by the Cooper pair binding energy, and correspondingly, the superconducting critical temperature (T c ), typically well-understood MKID materials such as aluminum (Al) present a lower limit on the operating frequency. Aluminum manganese (Al-Mn) is a promising candidate material for MKIDs because it can be fabricated with nearly identical processing as pure Al, but allows for control of the T c , with varying levels of Mn doping or post-deposition heat treatment. In this study, we present initial results from an early characterization of AlMn using a series of lumped-element superconducting microwave resonators, including measurements of T c , internal quality factor, and noise performance over a range of Mn doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗