Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerating Scientific Simulations with Bi-Fidelity Weighted Transfer Learning

High-fidelity modeling is an essential design tool for many engineering applications. However, for complex systems, computational cost can be a limiting factor. Analyzing parameter sensitivity, uncertainty quantification, and design optimization require many model evaluations. Surrogate models are often used to develop the relationship between model parameters and quantities of interest. However, in the case of complex systems, surrogate models require several degrees of freedom and, thus, a large number of data points to determine the correct dependencies. For many applications, this may be prohibitively expensive. The reduction of computational requirements can be achieved by leveraging low-fidelity models. Low-fidelity models represent the system at a coarser resolution with the advantage of computational efficiency. Therefore, a bi-fidelity modeling paradigm, which augments the accuracy of a low-fidelity model in a computationally efficient manner by invoking limited runs of a high-fidelity model, can be leveraged to sufficiently balance the accuracy and computational requirements. In this work, a bi-fidelity weighted transfer learning method using neural networks was applied to a computational fluid dynamics heat transfer modeling problem. The transfer learning advantage was investigated as a function of hyperparameters. Our main finding is that the use of a bi-fidelity modeling paradigm achieves accuracy close to that of a high-fidelity Gaussian process model while significantly reducing computational cost. The bi-fidelity model achieves comparable performance with 90 high-fidelity samples-that is, 60% less than the samples needed to achieve similar accuracy without the use of bi-fidelity modeling,

Borowiec, Katarzyna↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Strong Correspondence in Evapotranspiration and Carbon Dioxide Fluxes Between Different Eddy Covariance Systems Enables Quantification of Landscape Heterogeneity in Dryland Fluxes

Abstract The eddy covariance method is widely used to investigate fluxes of energy, water, and carbon dioxide at landscape scales, providing important information on how ecological systems function. Flux measurements quantify ecosystem responses to environmental perturbations and management strategies, including nature‐based climate‐change mitigation measures. However, due to the high cost of conventional instrumentation, most eddy covariance studies employ a single system, limiting spatial representation to the flux footprint. Insufficient replication may be limiting our understanding of ecosystem behavior. To address this limitation, we deployed eight lower‐cost eddy covariance systems in two clusters around two conventional eddy covariance systems in the Chihuahuan Desert of North America for a period of 2 years. These dryland settings characterized by large temperature variations and relatively low carbon dioxide fluxes represented a challenging setting for eddy covariance. We found very good closure of energy and water balance across all systems (within ±9% of unity). We found very good correspondence between the lower‐cost and conventional systems' fluxes of sensible heat (with concordance correlation coefficient (CCC) of ≥0.87), latent energy (evapotranspiration; CCC ≥ 0.89), and useful correspondence in the net ecosystem exchange ((NEE); with CCC ≥ 0.4) at the daily temporal resolution. Relative to the conventional systems, the low‐frequency systems were characterized by a higher level of random error, particularly in the NEE fluxes. Lower‐cost systems can enable wider deployment affording better replication and sampling of spatiotemporal variability at the expense of greater measurement noise that might be limiting for certain applications. Replicated eddy covariance observations may be useful when addressing gaps in the existing monitoring of critical and underrepresented ecosystems and for measuring areas larger than a single flux footprint.

54 ENVIRONMENTAL SCIENCES↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

[ 18 F](2 S ,4 R )4-Fluoroglutamine PET Detects Glutamine Pool Size Changes in Triple-Negative Breast Cancer in Response to Glutaminase Inhibition

Glutaminolysis is a metabolic pathway adapted by many aggressive cancers, including triple-negative breast cancers (TNBC), to utilize glutamine for survival and growth. In this study, we examined the utility of [ 18 F](2S,4R)4-fluoroglutamine ([ 18 F]4F-Gln) PET to measure tumor cellular glutamine pool size, whose change might reveal the pharmacodynamic (PD) effect of drugs targeting this cancer-specific metabolic pathway. High glutaminase (GLS) activity in TNBC tumors resulted in low cellular glutamine pool size assayed via high-resolution 1 H magnetic resonance spectroscopy (MRS). GLS inhibition significantly increased glutamine pool size in TNBC tumors. MCF-7 tumors, with inherently low GLS activity compared to TNBC, displayed a larger baseline glutamine pool size that did not change as much in response to GLS inhibition. The tumor-to-blood-activity-ratios (T/B) obtained from [ 18 F]4F-Gln PET images matched the distinct glutamine pool sizes of both tumor models at baseline. After a short course of GLS inhibitor treatment, the T/B values increased significantly in TNBC, but did not change in MCF-7 tumors. Across both tumor types and after GLS inhibitor or vehicle treatment, we observed a strong positive correlation between T/B values and tumor glutamine pool size measured using MRS ( r 2 =0.71). In conclusion, [ 18 F]4F-Gln PET tracked cellular glutamine pool size in breast cancers with differential GLS activity and detected increases in cellular glutamine pool size induced by GLS inhibitors. This work accomplished the first necessary step towards validating [ 18 F]4F-Gln PET as a PD marker for glutaminase-targeting drugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact multiwire proportional counters for the detection of fission fragments

Two large area multistep position sensitive (two dimensional) multiwire proportional counters have been developed for experiments involving study of fission dynamics using general purpose scattering chamber facility at IUAC. Both detectors have an active area of 20x10 cm{sup 2} and provide position signals in horizontal (X) and vertical (Y) planes, timing signal for time of flight measurements and energy signal giving the differential energy loss in the active volume. The design features are optimized for the detection of low energy heavy ions at very low gas pressures. Special care was taken in setting up the readout electronics, constant fraction discriminators for position signals in particular, to get optimum position and timing resolutions along with high count rate handling capability of low energy heavy ions. A custom made charge sensitive preamplifier, having lower gain and shorter decay time, has been developed for extracting the differential energy loss signal. The position and time resolutions of the detectors were determined to be 1.1 mm full width at half maximum (FWHM) and 1.7 ns FWHM, respectively. The detector could handle heavy ion count rates exceeding 20 kHz without any breakdown. Time of flight signal in combination with differential energy loss signal gives a clean separation of fission fragments from projectile and target like particles. The timing and position signals of the detectors are used for fission coincidence measurements and subsequent extraction of their mass, angular, and total kinetic energy distributions. This article describes systematic study of these fission counters in terms of efficiency, time resolution, count rate handling capability, position resolution, and the readout electronics. The detector has been operated with both five electrode geometry and four electrode geometry, and a comparison has been made in their performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inelastic x-ray scattering measurements of phonon dynamics in URu 2 Si 2

In this paper, we study high-resolution inelastic x-ray scattering measurements of the acoustic phonons of URu 2 Si 2 . At all temperatures, the longitudinal acoustic phonon linewidths are anomalously broad at small wave vectors revealing a previously unknown anharmonicity. The phonon modes do not change significantly upon cooling into the hidden order phase. In addition, our data suggest that the increase in thermal conductivity in the hidden order phase cannot be driven by a change in phonon dispersions or lifetimes. Hence, the phonon contribution to the thermal conductivity is likely much less significant compared to that of the magnetic excitations in the low temperature phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solubility controls on plutonium and americium release in subsurface environments exposed to acidic processing wastes

To identify the role of waste composition and sediment interactions in controlling Pu and Am mobility in contaminated sediments at Hanford, a legacy nuclear site, Pu and Am concentrations in solutions equilibrated with contaminated sediments from beneath the 216-Z-9 (Z-9) Trench were compared to the solubilities of PuO 2 materials, synthesized by methods representative of the disposed wastes, in the absence of sediments. Furthermore, this work shows that the solubilities of PuO 2 materials synthesized by different methods, and with varying particle sizes, agree with PuO 2 (am,hyd), although dissolution kinetics differed between materials. According to saturation index (SI) calculations, PuO 2 (am,hyd) is likely also controlling Pu release from sediments under conditions where phosphate concentrations are low. However, both Pu-phosphate and Am-phosphate phases, identified in SI calculations and by high resolution transmission electron microscopy, play roles in controlling release in low pH, high phosphate, shallow sediments just below the Z-9 Trench. The elevated phosphate is likely due to decomposition of tributyl phosphate from waste solutions over time. Sediments from deeper in the subsurface beneath the Z-9 Trench are less acidic and contain less phosphate, with Pu solubility likely controlled by PuO 2 (am,hyd) that precipitated following neutralization of the acidic waste stream. Controls on Am concentrations in deeper sediments are more complex and potentially involve sediment adsorption and/or release from Pu (1-x) Am x O 2 following Am in-growth. The concentrations of both Pu and Am were elevated in the colloidal fraction associated with shallow sediments, but not in PuO 2 experiments, suggesting the presence of Pu/Am pseudocolloids (e.g., Pu/Am associated with mineral colloids). However, Pu and Am association with the colloidal size fraction was not observed in deeper sediments, suggesting transport of Pu and Am to these depths beneath the Z-9 Trench was not due to colloidal transport.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High Speed Intact Protein Characterization Using 4X Frequency Multiplication, Ion Trap Harmonization, and 21 Tesla FTICR-MS

Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultra-high resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g. proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers, such as Orbitrap and ion cyclotron resonance (FTICR-MS) with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of ultra-high resolution spectra. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4X greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW=78 kDa) and monoclonal antibody (MW=150 kDa) were isotopically resolved with detection periods of 384 ms and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time-scales compatible with online separations.

Shaw, Jared B.↗

Temperature-resolution anomalies in the reconstruction of time dynamics from energy-loss experiments

Inelastic scattering techniques provide a powerful approach to studying electron and nuclear dynamics, via reconstruction of a propagator that quantifies the time evolution of a system. There is now growing interest in applying such methods to very low energy excitations, such as lattice vibrations, but in this limit the cross section is no longer proportional to a propagator. Significant deviations occur due to the finite temperature Bose statistics of the excitations. Here we consider this issue in the context of high-resolution electron energy-loss experiments on the copper-oxide superconductor Bi 2 Sr 2 CaCu 2 O 8 . We find that simple division of a Bose factor yields an accurate propagator on energy scales greater than the resolution width. However, at low energy scales, the effects of resolution and finite temperature conspire to create anomalies in the dynamics at long times. Here, we compare two practical ways for dealing with such anomalies, and discuss the range of validity of the technique in light of this comparison.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mapping Quasar Light Echoes in 3D with Ly α Forest Tomography

The intense radiation emitted by luminous quasars dramatically alters the ionization state of their surrounding IGM. This so-called proximity effect extends out to tens of Mpc, and manifests as large coherent regions of enhanced Ly (Ly) forest transmission in absorption spectra of background sightlines. In this work, we present a novel method based on Ly forest tomography, which is capable of mapping these quasar "light echoes" in three dimensions. Using a dense grid (10-100) of faint (m r ≈ 24.7 mag) background galaxies as absorption probes, one can measure the ionization state of the IGM in the vicinity of a foreground quasar, yielding detailed information about the quasar's radiative history and emission geometry. An end-to-end analysis-combining cosmological hydrodynamical simulations post-processed with a quasar emission model, realistic estimates of galaxy number densities, and instrument + telescope throughput-is conducted to explore the feasibility of detecting quasar light echoes. We present a new, fully Bayesian statistical method that allows one to reconstruct quasar light echoes from thousands of individual low-S/N transmission measurements. Armed with this tool, we undertake an exhaustive parameter study and show that light echoes can be convincingly detected for luminous (M 1450 <-27.5 mag, corresponding to m 1450 < 18.4 mag at z≃3.6) quasars at redshifts 3 < z QSO < 5, and that a relative precision better than 20% on the quasar age can be achieved for individual objects in the expected range of ages between 1 and 100 Myr. The observational requirements are relatively modest: Moderate-resolution (R ≳ 750), multiobject spectroscopy at a low signal-to-noise ratio (S/N > 5) is sufficient, requiring three-hour integrations using existing instruments on 8 m class telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

THE VLA-COSMOS SURVEY. IV. DEEP DATA AND JOINT CATALOG

In the context of the VLA-COSMOS Deep project, additional VLA A array observations at 1.4 GHz were obtained for the central degree of the COSMOS field and combined with the existing data from the VLA-COSMOS Large project. A newly constructed Deep mosaic with a resolution of 2.''5 was used to search for sources down to 4{sigma} with 1{sigma} {approx} 12 {mu}Jy beam{sup -1} in the central 50' x 50'. This new catalog is combined with the catalog from the Large project (obtained at 1.''5 x 1.''4 resolution) to construct a new Joint catalog. All sources listed in the new Joint catalog have peak flux densities of {>=}5{sigma} at 1.''5 and/or 2.''5 resolution to account for the fact that a significant fraction of sources at these low flux levels are expected to be slightly resolved at 1.''5 resolution. All properties listed in the Joint catalog, such as peak flux density, integrated flux density, and source size, are determined in the 2.''5 resolution Deep image. In addition, the Joint catalog contains 43 newly identified multi-component sources.

79 ASTRONOMY AND ASTROPHYSICS↗

EVN observations of HESS J1943+213: evidence for an extreme TeV BL Lac object

We report on the 1.6 GHz (18 cm) very long baseline interferometry (VLBI) observations of the unresolved, steady TeV source HESS J1943+213 located in the Galactic plane, performed with the European VLBI Network (EVN) in 2014. Our new observations with a nearly full EVN array provide the deepest image of HESS J1943+213 at the highest resolution ever achieved, enabling us to resolve the long-standing issues of the source identification. The milliarcsecond-scale structure of HESS J1943+213 has a clear asymmetric morphology consisting of a compact core and a diffuse jet-like tail. This is broadly consistent with the previous e-EVN observations of the source performed in 2011 and re-analyzed in this work. The core component is characterized by the brightness temperature of ≳1.8×10{sup 9} K, which is typical for low-luminosity blazars in general. Overall, the radio properties of HESS J1943+213 are consistent with the source classification as an “extreme high-frequency-peaked BL Lac object.” Remarkably, we note that because HESS J1943+213 does not reveal any optical or infrared signatures of the active galactic nucleus activity, it would never be recognized and identified as a BL Lac object if not for its location close to the Galactic plane where the High Energy Stereoscopic System surveyed for and the follow-up dedicated X-ray and radio studies triggered by the source detection in the TeV range. Our results suggest, therefore, a presence of an unrecognized, possibly very numerous population of particularly extreme HBLs and simultaneously demonstrate that the low-frequency VLBI observations with high angular resolution are indispensable for a proper identification of such objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic electrochemical cell for in situ structural characterization of amorphous thin-film catalysts using high-energy X-ray scattering

Porous, high-surface-area electrode architectures are described that allow structural characterization of interfacial amorphous thin films with high spatial resolution under device-relevant functional electrochemical conditions using high-energy X-ray (>50 keV) scattering and pair distribution function (PDF) analysis. Porous electrodes were fabricated from glass-capillary array membranes coated with conformal transparent conductive oxide layers, consisting of either a 40 nm–50 nm crystalline indium tin oxide or a 100 nm–150 nm-thick amorphous indium zinc oxide deposited by atomic layer deposition. These porous electrodes solve the problem of insufficient interaction volumes for catalyst thin films in two-dimensional working electrode designs and provide sufficiently low scattering backgrounds to enable high-resolution signal collection from interfacial thin-film catalysts. For example, PDF measurements were readily obtained with 0.2 Å spatial resolution for amorphous cobalt oxide films with thicknesses down to 60 nm when deposited on a porous electrode with 40 µm-diameter pores. This level of resolution resolves the cobaltate domain size and structure, the presence of defect sites assigned to the domain edges, and the changes in fine structure upon redox state change that are relevant to quantitative structure–function modeling. The results suggest the opportunity to leverage the porous, electrode architectures for PDF analysis of nanometre-scale surface-supported molecular catalysts. In addition, a compact 3D-printed electrochemical cell in a three-electrode configuration is described which is designed to allow for simultaneous X-ray transmission and electrolyte flow through the porous working electrode.

36 MATERIALS SCIENCE↗

Quantifying How Density Gradients and Front Curvature Affect Carbon Detonation Strength during SNe Ia

Accurately reproducing the physics behind the detonations of SNe Ia and the resultant nucleosynthetic yields is important for interpreting observations of spectra and remnants. The scales of the processes involved span orders of magnitudes, making the problem computationally impossible to ever fully resolve in full-star simulations in the present and near future. In the lower density regions of the star, the curvature of the detonation front will slow the detonation, affecting the production of intermediate mass elements. We find that shock strengthening due to the density gradient present in the outer layers of the progenitor is essential for understanding the nucleosynthesis there, with burning extending well below the density at which a steady-state detonation is extinct. We show that a complete reaction network is not sufficient to obtain physical detonations at high densities and modest resolution due to numerical mixing at the unresolved reaction front. At low densities, below 6 × 10 5 g cm -3 , it is possible to achieve high enough resolution to separate the shock and the reaction region, and the abundance structure predicted by fully resolved quasi-steady-state calculations is obtained. For our best current benchmark yields, we utilize a method in which the unresolved portion of Lagrangian histories are reconstructed based on fully resolved quasi-steady-state detonation calculations. These computations demonstrate that under-resolved simulations agree approximately, ~10% in post-shock values of temperature, pressure, density, and abundances, with expected detonation structures sufficiently far from the under-resolved region, but that there is still room for some improvement in the treatment of subgrid reactions in the hydrodynamics to before better than 1% can be achieved at all densities.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasi-zero lattice mismatch and band alignment of BaTiO{sub 3} on epitaxial (110)Ge

Growth, structural, and band alignment properties of pulsed laser deposited amorphous BaTiO{sub 3} on epitaxial molecular beam epitaxy grown (110)Ge layer, as well as their utilization in low power transistor are reported. High-resolution x-ray diffraction demonstrated quasi-zero lattice mismatch of BaTiO{sub 3} on (110)Ge. Cross-sectional transmission electron microscopy micrograph confirms the amorphous nature of BaTiO{sub 3} layer as well as shows a sharp heterointerface between BaTiO{sub 3} and Ge with no traceable interfacial layer. The valence band offset, {Delta}E{sub v}, of 1.99 {+-} 0.05 eV at the BaTiO{sub 3}/(110)Ge heterointerface is measured using x-ray photoelectron spectroscopy. The conduction band offset, {Delta}E{sub c}, of 1.14 {+-} 0.1 eV is calculated using the bandgap energies of BaTiO{sub 3} of 3.8 eV and Ge of 0.67 eV. These band offset parameters for carrier confinement and the interface chemical properties of the BaTiO{sub 3}/(110)Ge system are significant advancement towards designing Ge-based p-and n-channel metal-oxide semiconductor field-effect transistors for low-power application.

36 MATERIALS SCIENCE↗