Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inflatable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

The {mu} problem and the axion in gauge mediation

We revisit the idea of generating the Higgs {mu} parameter through a spontaneously broken Peccei-Quinn (PQ) symmetry in a gauge-mediated supersymmetry breaking scenario. For the messenger scale of gauge mediation higher than the PQ scale, the setup naturally generates {mu}{approx}m{sub soft} and the Higgs soft parameter B < or approx. O(m{sub soft}) with the CP phase of B aligned to the phase of gaugino masses, while giving the PQ scale v{sub PQ{approx}{radical}}(m{sub soft{Lambda}}), where m{sub soft} denotes the gauge-mediated gaugino or sfermion masses and {Lambda} is the cutoff scale which can be identified as the Planck scale or the grand unified theory scale. The PQ sector of the model results in distinctive cosmology including a late thermal inflation. We discuss the issue of dark matter and baryogenesis in the resulting thermal inflation scenario, and find that a right amount of gravitino dark matter can be produced together with a successful Affleck-Dine leptogenesis, when the gravitino mass m{sub 3/2}=O(100) keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Superheavy dark matter through Higgs portal operators

The WIMPzilla hypothesis states that the dark matter is a super-weakly-interacting and super-heavy particle. Conventionally, the WIMPzilla abundance is set by gravitational particle production during or at the end of inflation. In this study we allow the WIMPzilla to interact directly with Standard Model fields through the Higgs portal, and we calculate the thermal production (freeze-in) of WIMPzilla dark matter from the annihilation of Higgs boson pairs in the plasma. The two particle-physics model parameters are the WIMPzilla mass and the Higgs-WIMPzilla coupling. The two cosmological parameters are the reheating temperature and the expansion rate of the universe at the end of inflation. We delineate the regions of parameters space where either gravitational or thermal production is dominant, and within those regions we identify the parameters that predict the observed dark matter relic abundance. Allowing for thermal production opens up the parameter space, even for Planck-suppressed Higgs-WIMPzilla interactions.

79 ASTRONOMY AND ASTROPHYSICS↗

Relaxion: A landscape without anthropics

The relaxion mechanism provides a potentially elegant solution to the hierarchy problem without resorting to anthropic or other fine-tuning arguments. This mechanism introduces an axion-like field, dubbed the relaxion, whose expectation value determines the electroweak hierarchy as well as the QCD strong C P -violating θ ¯ parameter. During an inflationary period, the Higgs mass squared is selected to be negative and hierarchically small in a theory which is consistent with ’t Hooft’s technical naturalness criteria. However, in the original model proposed by Graham, Kaplan, and Rajendran, the relaxion does not solve the strong C P problem, and in fact contributes to it, as the coupling of the relaxion to the Higgs field and the introduction of a linear potential for the relaxion produces large strong C P violation. Herein we resolve this tension by considering inflation with a Hubble scale which is above the QCD scale but below the weak scale, and estimating the Hubble temperature dependence of the axion mass. The relaxion potential is thus very different during inflation than it is today. We find that provided the inflationary Hubble scale is between the weak scale and about 3 GeV, the relaxion resolves the hierarchy, strong C P , and dark matter problems in a way that is technically natural.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exciting Gauge Field and Gravitons in Brane-Antibrane Annihilation

In this Letter we point out the inevitability of an explosive production of gauge field and gravity wave during an open string tachyon condensation in a cosmological setting, in an effective field theory model. We will be particularly studying a toy model of brane-antibrane inflation in a warped throat where inflation ends via tachyon condensation. We point out that a tachyonic instability helps fragmenting the homogeneous tachyon and excites gauge field and contributes to the stress-energy tensor which also feeds into the gravity waves.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonlinear Metric Perturbation Enhancement of Primordial Gravitational Waves

We present the evolution of the full set of Einstein equations during preheating after inflation. We study a generic supersymmetric model of hybrid inflation, integrating fields and metric fluctuations in a 3-dimensional lattice. We take initial conditions consistent with Einstein's constraint equations. The induced preheating of the metric fluctuations is not large enough to backreact onto the fields, but preheating of the scalar modes does affect the evolution of vector and tensor modes. In particular, they do enhance the induced stochastic background of gravitational waves during preheating, giving an energy density in general an order of magnitude larger than that obtained by evolving the tensor fluctuations in an homogeneous background metric. This enhancement can improve the expectations for detection by planned gravitational wave observatories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mechanism Design for Demand Response Programs

Demand response (DR) programs serve to reduce the consumption of electricity at times when the supply is scarce and expensive. Consumers or agents with flexible consumption profiles are recruited by an aggregator who manages the DR program. The aggregator calls on a subset of its pool of recruited agents to reduce their electricity use during DR events. Agents are paid for reducing their energy consumption from contractually established baselines. Baselines are counter-factual consumption estimates of the energy an agent would have consumed if they were not participating in the DR program. Baselines are used to determine payments to agents. This creates an incentive for agents to inflate their baselines in order to increase the payments they receive. There are several newsworthy cases of agents gaming their baseline for economic benefit. We propose a novel self-reported baseline mechanism (SRBM) where each agent reports its baseline and marginal utility. These reports are strategic and need not be truthful. Based on the reported information, the aggregator selects or calls on agents with a certain probability to meet the load reduction target. Called agents are paid for observed reductions from their self-reported baselines. Agents who are not called face penalties for consumption shortfalls below their baselines. Under SRBM, we show that truthful reporting of baseline consumption and marginal utility is a dominant strategy. Thus, SRBM eliminates the incentive for agents to inflate baselines. SRBM is assured to meet the load reduction target. To conclude, we show that SRBM is almost optimal in the metric of average cost of DR provision faced by the aggregator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical Model Development of a Variable-Geometry Attenuator Wave Energy Converter

Because the wave energy industry is still in its infancy, an optimal design for wave energy converters (WECs) has yet to be established; more work is needed to explore various cost-reduction pathways. The primary cost-reduction pathway considered for this work is the optimization of the geometric profile on an attenuator WEC to maximize power production while, at the same time, minimizing capital expenditures through the use of variable-geometry modules. In this investigation, the variable-geometry modules consist of inflatable bags placed on either side of a base central steel cylinder that would be inflated in low-moderate sea states to maximize power capture and then deflated in moderate-extreme sea states to minimize wave loading. The numerical model and simulation of the attenuator WEC were developed and completed using WEC-Sim, which is an open-source code that is appropriate for use in evaluating the dynamic response of the different WEC models in operational seas. The power production estimates were obtained from the Wave Energy Prize (WEP) sea states, which are representative of U. S. deployment sites, to calculate the average climate capture width that is used in the WEP ACE calculation. Preliminary capital expenditure costs were obtained assuming the base central steel cylinder mass was equal to the fluid displaced mass, minus the mass of the variable-geometry bags. The additional weight required to offset the additional buoyancy from the variable-geometry bags was assumed to come from the addition of seawater ballast. The variable-geometry attenuator model was found to have a similar power capture efficiency as a fixed-body model, but is expected to have a lower characteristic capital expenditure given its more streamlined profile, which demonstrates that variable-geometry modules may provide a realistic cost-reduction pathway to help design a more cost-competitive WEC.

50 EE - Wind and Water Power Program - Water (EE-4↗

Design of a Two-Body Wave Energy Converter Featuring Controllable Geometry

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continue to prove themselves as a promising modern renewable energy field. A wave energy converter (WEC) concept currently being explored is the variable-geometry WEC (VGWEC), which aims to add an extra control option to WEC design. VGWECs attempt to incorporate controllable geometric features to adjust the floating body hydrodynamics to favor either power absorption, load shedding, or other operational goals. These variable geometry components have been proposed to be controlled on a sea-state-to-sea-state or wave-to-wave time scale depending on the force (or torque) and bandwidth limitations of the actuators required to manipulate just the controllable geometric hull features. Having control over both the WEC geometry components and the power takeoff (PTO) offers the potential to improve overall system performance and reliability if a cost-effective solution can be found for a given WEC architecture. This paper will present the recent developments and results of a VGWEC concept that incorporates variable-geometry modules into a two-body WEC. In the proposed VGWEC concept, the variable-geometry modules consist of air-inflatable bags in the surface float and a water inflatable ring in the subsurface body. The surface float is tethered directly to the subsurface body through tether lines, each connected to a separate PTO. Adjusting the geometry of both the surface and subsurface bodies along with the PTO coefficients can maximize power in design sea states while reducing motion response and PTO forces when transitioning to sea states where rated power is reached and load shedding is prioritized. The ability to transition between operating condition is expected to increase the sea state operational map and power capacity.

geometry control↗

Ex vivo evaluation of a coherent normalization procedure to quantify in vivo finger strontium XRS measurements

Purpose: Energy dispersive x-ray fluorescence spectroscopy (XRS) measurements were performed on human cadaver index fingers to measure bone strontium content in the presence of intact overlying soft-tissue. This work assesses the feasibility of applying a normalization procedure including soft-tissue correction of x-ray absorption as a means to quantify an ex vivo bone strontium XRS measurement. Methods: Bone strontium measurements were made using an excitation-detection system incorporating an {sup 125}I x-ray excitation source and an Ortec registered Ametek-AMT Si(Li) detector in 180 deg. backscatter geometry. Spectral processing was accomplished using an in-house nonlinear least-squares Marquardt fitting routine. Bone strontium was quantified using an egs5 Monte Carlo based x-ray soft-tissue correction algorithm in conjunction with the normalization of strontium x-rays to the coherent scatter peaks of 35.5 keV {sup 125}I {gamma}-rays. Results: Comparison of tissue intact and bare bone finger XRS measurement quantification attempts revealed an overall discrepancy of 18.6% that is attributed primarily to the significant contribution of soft-tissue to coherent scatter of 35.5 keV source {gamma}-rays and to a lesser degree, inconsistencies with the simulated tissue correction model. Work toward the beginnings of an experimentally derived tissue correction model, as a means to validate the simulated model, have been reported. Two observations hinted at a systematic inflation of the observed K{beta} peak area. First, strontium concentrations estimated by K{alpha} peak areas were less than the K{beta} peak areas by 28.6% (p < 0.0001) and 10.5% (p < 0.001) for tissue intact and bare bone measurements, respectively. Second, the K{alpha}:K{beta} x-ray average ratios between tissue corrected (3.61 {+-} 0.55) and bare bone predicted (4.4 {+-} 0.4) did not agree (p < 0.0001) and pointed to shortcomings with the current processing treatment of strontium K x-ray peak area extraction. Through finger bone XRS measurements, bone strontium concentration in the Caucasian population was estimated at 95 {+-} 15 {mu}g Sr/g dry bone. Conclusions: The discrepancies observed: between quantification attempts of tissue corrected and bare bone measurements, the inflated estimates of K{beta} relative to K{alpha} peak concentrations and between observed and expected K{alpha}:K{beta} ratios, have indicated that shortcomings with the bone strontium coherent normalization and tissue correction procedure exist. Coherent scatter contribution of soft-tissue overlying bone, tissue correction model limitations, and spectra processing issues are all mentioned as sources of observed discrepancies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric and deformation effects of image-guided interventions during stereotactic body radiation therapy of the prostate using an endorectal balloon

Purpose: During stereotactic body radiation therapy (SBRT) for the treatment of prostate cancer, an inflatable endorectal balloon (ERB) may be used to reduce motion of the target and reduce the dose to the posterior rectal wall. This work assessed the dosimetric impact of manual interventions on ERB position in patients receiving prostate SBRT and investigated the impact of ERB interventions on prostate shape. Methods: The data of seven consecutive patients receiving SBRT for the treatment of clinical stage T1cN0M0 prostate cancer enrolled in a multi-institutional, IRB-approved trial were analyzed. The SBRT dose was 50 Gy in five fractions to a planning target volume (PTV) that included the prostate (implanted with three fiducial markers) with a 3-5 mm margin. All plans were based on simulation images that included an ERB inflated with 60 cm{sup 3} of air. Daily kilovoltage cone-beam computed tomography (CBCT) imaging was performed to localize the PTV, and an automated fusion with the planning images yielded displacements required for PTV relocalization. When the ERB volume and/or position were judged to yield inaccurate repositioning, manual adjustment (ERB reinflation and/or repositioning) was performed. Based on all 59 CBCT image sets acquired, a deformable registration algorithm was used to determine the dose received by, displacement of, and deformation of the prostate, bladder (BLA), and anterior rectal wall (ARW). This dose tracking methodology was applied to images taken before and after manual adjustment of the ERB (intervention), and the delivered dose was compared to that which would have been delivered in the absence of intervention. Results: Interventions occurred in 24 out of 35 (69%) of the treated fractions. The direct effect of these interventions was an increase in the prostate radiation dose that included 95% of the PTV (D95) from 9.6 {+-} 1.0 to 10.0 {+-} 0.2 Gy (p = 0.06) and an increase in prostate coverage from 94.0% {+-} 8.5% to 97.8% {+-} 1.9% (p = 0.03). Additionally, ERB interventions reduced prostate deformation in the anterior-posterior (AP) direction, reduced errors in the sagittal rotation of the prostate, and increased the similarity in shape of the prostate to the radiotherapy plan (increased Dice coefficient from 0.76 {+-} 0.06 to 0.80 {+-} 0.04, p = 0.01). Postintervention decreases in prostate volume receiving less than the prescribed dose and decreases in the voxel-wise displacement of the prostate, bladder, and anterior rectal wall were observed, which resulted in improved dose-volume histogram (DVH) characteristics. Conclusions: Image-guided interventions in ERB volume and/or position during prostate SBRT were necessary to ensure the delivery of the dose distribution as planned. ERB interventions resulted in reductions in prostate deformations that would have prevented accurate localization of patient anatomy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-397: Include Organ Deformation Into Dose Calculation of Prostate Brachytherapy

Purpose: Prostate brachytherapy is an important curative treatment for patients with localized prostate cancer. In brachytherapy, rectal balloon is generally needed to adjust for unfavorable prostate position for seed placement. However, rectal balloon causes prostate deformation, which is not accounted for in dosimetric planning. Therefore, it is possible that brachytherapy dosimetry deviates significantly from initial plan when prostate returns to its non-deformed state (after procedure). The goal of this study is to develop a method to include prostate deformation into the treatment planning of brachytherapy dosimetry. Methods: We prospectively collected ultrasound images of prostate pre- and post- rectal balloon inflation from thirty five consecutive patients undergoing I-125 brachytherapy. Based on the cylinder coordinate systems, we learned the initial coordinate transformation parameters between the manual segmentations of both deformed and non-deformed prostates of each patient in training set. With the nearest-neighbor interpolation, we searched the best transformation between two coordinate systems to maximum the mutual information of deformed and non-deformed images. We then mapped the implanted seeds of five selected patients from the deformed prostate into non-deformed prostate. The seed position is marked on original pre-inflation US image and it is imported into VariSeed software for dose calculation. Results: The accuracy of image registration is 87.5% as quantified by Dice Index. The prostate coverage V100% dropped from 96.5±0.5% of prostate deformed plan to 91.9±2.6% (p<0.05) of non-deformed plan. The rectum V100% decreased from 0.44±0.26 cc to 0.10±0.18 cc (p<0.05). The dosimetry of the urethra showed mild change but not significant: V150% changed from 0.05±0.10 cc to 0.14±0.15 cc (p>0.05) and D1% changed from 212.9±37.3 Gy to 248.4±42.8 Gy (p>0.05). Conclusion: We have developed a deformable image registration method that allows dosimetry calculation in the non-deformed prostate – which may be used to more accurately reflect “true” dosimetry during planning.

60 APPLIED LIFE SCIENCES↗

SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance of the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.

60 APPLIED LIFE SCIENCES↗

SU-F-T-25: Design and Implementation of a Multi-Purpose Applicator for Pelvic Brachytherapy Applications

Purpose: The current generation of inflatable multichannel brachytherapy applicators, such as the Varian Capri, have limited implementation to only vaginal and rectal cancers. While there are similar designs utilizing rigid, non-inflatable applicators, these alternatives could cause increased dose to surrounding tissue due to air gaps. Modification of the Capri could allow for easier treatment planning by reducing the number of channels and increased versatility by modifying the applicator to include an attachable single tandem for cervical or multiple tandems for endometrial applications. Methods: A Varian Capri applicator was simulated in water to replicate a patient. Multiple plans were optimized to deliver a prescribed dose of 100 cGy at 5mm away from the exterior of the applicator using six to thirteen existing channels. The current model was expanded upon to include a detachable tandem or multiple tandoms to increase its functionality to both cervical and endometrial cancers. Models were constructed in both threedimensional rendering software and Monte Carlo to allow prototyping and simulations. Results: Treatment plans utilizing six to thirteen channels produced limited dosimetric differences between channel arrangements, with a seven channel plan very closely approximating the thirteen channels. It was concluded that only seven channels would be necessary in future simulations to give an accurate representation of the applicator. Tandem attachments were prototyped for the applicator to demonstrate the ease of which they could be included. Future simulation in treatment planning software and Monte Carlo results will be presented to further define the ideal applicator geometry Conclusion: The current Capri applicator design could be easily modified to increase applicability to include cervical and endometrial treatments in addition to vaginal and rectal cancers. This new design helps in a more versatile single use applicator that can easily be inserted and to further reduce dose to critical structures during brachytherapy treatments.

60 APPLIED LIFE SCIENCES↗

WE-AB-202-07: Ventilation CT: Voxel-Level Comparison with Hyperpolarized Helium-3 & Xenon-129 MRI

Purpose: To compare the spatial correlation of ventilation surrogates computed from inspiratory and expiratory breath-hold CT with hyperpolarized Helium-3 & Xenon-129 MRI in a cohort of lung cancer patients. Methods: 5 patients underwent expiration & inspiration breath-hold CT. Xenon-129 & {sup 1}H MRI were also acquired at the same inflation state as inspiratory CT. This was followed immediately by acquisition of Helium-3 & {sup 1}H MRI in the same breath and at the same inflation state as inspiratory CT. Expiration CT was deformably registered to inspiration CT for calculation of ventilation CT from voxel-wise differences in Hounsfield units. Inspiration CT and the Xenon-129’s corresponding anatomical {sup 1}H MRI were registered to Helium-3 MRI via the same-breath anatomical {sup 1}H MRI. This enabled direct comparison of CT ventilation with Helium-3 MRI & Xenon-129 MRI for the median values in corresponding regions of interest, ranging from finer to coarser in-plane dimensions of 10 by 10, 20 by 20, 30 by 30 and 40 by 40, located within the lungs as defined by the same-breath {sup 1}H MRI lung mask. Spearman coefficients were used to assess voxel-level correlation. Results: The median Spearman’s coefficients of ventilation CT with Helium-3 & Xenon-129 MRI for ROIs of 10 by 10, 20 by 20, 30 by 30 and 40 by 40 were 0.52, 0.56, 0.60 and 0.68 and 0.40, 0.42, 0.52 and 0.70, respectively. Conclusion: This work demonstrates a method of acquiring CT & hyperpolarized gas MRI (Helium-3 & Xenon-129 MRI) in similar breath-holds to enable direct spatial comparison of ventilation maps. Initial results show moderate correlation between ventilation CT & hyperpolarized gas MRI, improving for coarser regions which could be attributable to the inherent noise in CT intensity, non-ventilatory effects and registration errors at the voxel-level. Thus, it may be more beneficial to quantify ventilation at a more regional level.

60 APPLIED LIFE SCIENCES↗

Simulated rRNA/DNA Ratios Show Potential To Misclassify Active Populations as Dormant

ABSTRACT The use of rRNA/DNA ratios derived from surveys of rRNA sequences in RNA and DNA extracts is an appealing but poorly validated approach to infer the activity status of environmental microbes. To improve the interpretation of rRNA/DNA ratios, we performed simulations to investigate the effects of community structure, rRNA amplification, and sampling depth on the accuracy of rRNA/DNA ratios in classifying bacterial populations as “active” or “dormant.” Community structure was an insignificant factor. In contrast, the extent of rRNA amplification that occurs as cells transition from dormant to growing had a significant effect ( P < 0.0001) on classification accuracy, with misclassification errors ranging from 16 to 28%, depending on the rRNA amplification model. The error rate increased to 47% when communities included a mixture of rRNA amplification models, but most of the inflated error was false negatives (i.e., active populations misclassified as dormant). Sampling depth also affected error rates ( P < 0.001). Inadequate sampling depth produced various artifacts that are characteristic of rRNA/DNA ratios generated from real communities. These data show important constraints on the use of rRNA/DNA ratios to infer activity status. Whereas classification of populations as active based on rRNA/DNA ratios appears generally valid, classification of populations as dormant is potentially far less accurate. IMPORTANCE The rRNA/DNA ratio approach is appealing because it extracts an extra layer of information from high-throughput DNA sequencing data, offering a means to determine not only the seedbank of taxa present in communities but also the subset of taxa that are metabolically active. This study provides crucial insights into the use of rRNA/DNA ratios to infer the activity status of microbial taxa in complex communities. Our study shows that the approach may not be as robust as previously supposed, particularly in complex communities composed of populations employing different growth strategies, and identifies factors that inflate the erroneous classification of active populations as dormant.

59 BASIC BIOLOGICAL SCIENCES↗

Why should we care about the top quark Yukawa coupling?

In the cosmological context, for the Standard Model to be valid up to the scale of inflation, the top quark Yukawa coupling y t should not exceed the critical value y t crit , coinciding with good precision (about 0.2‰) with the requirement of the stability of the electroweak vacuum. So, the exact measurements of y t may give an insight on the possible existence and the energy scale of new physics above 100 GeV, which is extremely sensitive to y t . In this study, we overview the most recent theoretical computations of and the experimental measurements of y t crit and the experimental measurements of y t . Within the theoretical and experimental uncertainties in y t , the required scale of new physics varies from 10⁷ GeV to the Planck scale, urging for precise determination of the top quark Yukawa coupling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A discrete nonetheless remarkable brick in de Sitter: The 'massless minimally coupled field'

Over the last ten years interest in the physics of de Sitter space-time has been growing very fast. Besides the supposed existence of a 'de Sitterian period' in inflation theories, the observational evidence of an acceleration of the universe expansion (interpreted as a positive cosmological constant or a 'dark energy' or some form of 'quintessence') has triggered a lot of attention in the physics community. A specific de Sitterian field called 'massless minimally coupled field' (mmc) plays a fundamental role in inflation models and in the construction of the de Sitterian gravitational field. A covariant quantization of the mmc field, a la Krein-Gupta-Bleuler was proposed in Class. Quantum. Grav. 17, 1415 (2000). In this talk, we will review this construction and explain the relevance of such a field in the construction of a massless spin-2 field in de Sitter space-time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accuracy of Some Approximate Gaussian Filters for the Navier--Stokes Equation in the Presence of Model Error

Bayesian state estimation of a dynamical system from a stream of noisy measurements is important in many geophysical and engineering applications where high dimensionality of the state space, sparse observations, and model error pose key challenges. In this work, three computationally feasible, approximate Gaussian data assimilation/filtering algorithms are considered in various regimes of turbulent 2D Navier--Stokes dynamics in the presence of model error. The first source of error arises from the necessary use of reduced models for the forward dynamics of the filters, while a particular type of representation error arises from the finite resolution of observations which mix up information about resolved and unresolved dynamics. Two stochastically parameterized filtering algorithms, referred to as cSPEKF and GCF, are compared with 3DVAR---a prototypical time-sequential algorithm known to be accurate for filtering dissipative systems for a suitably inflated “background” covariance. We provide the first evidence that the stochastically parameterized algorithms, which do not rely on detailed knowledge of the underlying dynamics and do not require covariance inflation, can compete with or outperform an optimally tuned 3DVAR algorithm, and they can overcome competing sources of error in a range of dynamical scenarios.

97 MATHEMATICS AND COMPUTING↗