Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Content-aware foveated camera for multi-target tracking

Modern image sensors deliver substantial space-time bandwidth, yet indiscriminate acquisition often overwhelms memory, computation, and downstream perception. We present a content-aware, multi-foveated camera that dynamically reallocates sensing and magnification to multiple regions of interest (ROIs). A phase-only spatial light modulator (SLM) serves as a solid-state, inertia-free beam-steering and lens element, enabling per-frame field-of-view (FOV) reconfiguration and content-aware target tracking. By interleaving frames across foveae, our system preserves a wide-FOV situational context while refreshing each ROI at high rates, thereby reducing data volume without degrading task performance. We constructed a prototype employing a single-SLM, single-sensor architecture and demonstrated its application in real-time multi-object tracking with dynamic ROI maintenance across multiple viewpoints. The approach offers a general pathway to integrate detection, tracking, and segmentation algorithms in the acquisition loop, shifting workload from post hoc processing to intelligent capture.

Zang, Zihan [Univ. of California, Los Angeles, CA ↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100% fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 μm width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. Overall, the experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

47 OTHER INSTRUMENTATION↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100$\%$ fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 $\mu$m width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. The experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Cell Deployment and First Use of Digital Image Correlation for In-Situ Strain Analysis of Irradiated Nuclear Fuel Rods During LOCA Transient

Digital image correlation (DIC) is a noncontact, optical method increasingly used across industries and research environments for acquiring multidimensional strain data. At Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS), DIC has been extensively applied to study the thermomechanical response of nuclear fuel claddings, yielding fundamental insights into material behavior. However, these efforts have focused exclusively on unirradiated materials and relied on the SATS out-of-cell infrastructure. Efforts over the past two years have been made to extend these capabilities to ORNL’s Irradiated Fuels Examination Laboratory SATS system within the hot-cells to enable testing of irradiated fuel cladding materials. Integrating DIC into the hot-cell SATS infrastructure presents unique challenges, including enabling remote operation of optical equipment and adapting auxiliary hot-cell systems for DIC implementation. This report discusses design, stand-up testing, and application of DIC to an irradiated nuclear fuel cladding segment. A DIC testing rig was successfully built and validated out-of-cell through extensive surrogate tests and calibrations. The rig and specialized DIC furnace were installed in the hot-cell, and a DIC test was successfully conducted. Results from that test correspond to expectations for Zr-based alloys and showed similar uncertainties compared to out-of-cell tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unsupervised individual tree crown detection in high-resolution satellite imagery

Rapidly and accurately detecting individual tree crowns in satellite imagery is a critical need for monitoring and characterizing forest resources. We present a two-stage semiautomated approach for detecting individual tree crowns using high spatial resolution (0.6 m) satellite imagery. First, active contours are used to recognize tree canopy areas in a normalized difference vegetation index image. Given the image areas corresponding to tree canopies, we then identify individual tree crowns as local extrema points in the Laplacian of Gaussian scale-space pyramid. The approach simultaneously detects tree crown centers and estimates tree crown sizes, parameters critical to multiple ecosystem models. As a demonstration, we used a ground validated, 0.6 m resolution QuickBird image of a sparse forest site. The two-stage approach produced a tree count estimate with an accuracy of 78% for a naturally regenerating forest with irregularly spaced trees, a success rate equivalent to or better than existing approaches. In addition, our approach detects tree canopy areas and individual tree crowns in an unsupervised manner and helps identify overlapping crowns. Furthermore, the method also demonstrates significant potential for further improvement.

54 ENVIRONMENTAL SCIENCES↗

SWIFT ULTRAVIOLET/OPTICAL TELESCOPE IMAGING OF STAR-FORMING REGIONS IN M81 AND HOLMBERG IX

We present Swift UV/Optical Telescope (UVOT) imaging of the galaxies M81 and Holmberg IX. We combine UVOT imaging in three near-ultraviolet (NUV) filters (uvw2: 1928 A; uvm2: 2246 A; uvw1: 2600 A) with ground-based optical imaging from the Sloan Digital Sky Survey to constrain the stellar populations of both galaxies. Our analysis consists of three different methods. First, we use the NUV imaging to identify UV star-forming knots and then perform spectral energy distribution (SED) modeling on the UV/optical photometry of these sources. Second, we measure surface brightness profiles of the disk of M81 in the NUV and optical. Lastly, we use SED fitting of individual pixels to map the properties of the two galaxies. In agreement with earlier studies, we find evidence for a burst in star formation in both galaxies starting {approx}200 Myr ago coincident with the suggested time of an M81-M82 interaction. In line with theories of its origin as a tidal dwarf, we find that the luminosity-weighted age of Holmberg IX is a few hundred million years. Both galaxies are best fit by a Milky Way dust extinction law with a prominent 2175 A bump. In addition, we describe a stacked median filter technique for modeling the diffuse background light within a galaxy and a Markov chain method for cleaning segment maps generated by SExtractor.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiochromic film calibration for low-energy seed brachytherapy dose measurement

Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement area for the I-125 irradiations, the accuracy of the calibration curve was degraded due to the presence of localized film heterogeneities. No degradation in the calibration curves was found when reducing the number of calibration points down to only 4, but with piecewise fitting, 6 calibration points as well as a blank film are required. Variations due to photon energy in film optical density of up to 3% were found above doses of 2 Gy. Conclusions: A modified procedure for performing EBT3 film calibration was established for use with low-energy brachytherapy seeds and high dose exposures. The energy dependence between 6 MV and I-125 photons is significant such that film calibrations should be done with an appropriately low-energy source when performing low-energy brachytherapy dose measurements. Two-segment piecewise fitting with the inclusion of errors in measured optical density as well as dose was found to result in the most accurate calibration curves. Above doses of 1 Gy, absolute dose measurements can be made with an accuracy of 1.6% for 6 MV beams and 5.7% for I-125 seed exposures if using the I-125 source for calibration, or 2.3% if using the 75 kVp photon beam for calibration.

07 ISOTOPE AND RADIATION SOURCES↗

3D Quantification of Pore Networks and Anthropogenic Carbon Mineralization in Stacked Basalt Reservoirs

Basalt formations are promising candidates for the geologic storage of anthropogenic CO 2 due to their storage capacity, porosity, permeability, and reactive geochemical trapping ability. The Wallula Basalt Carbon Storage Pilot Project demonstrated that supercritical CO 2 injected into >800 m deep Columbia River Basalt Group stacked reservoir flow tops mineralizes to ankerite-siderite-aragonite on month-year timescales, with 60% of the 977 metric tonnes of CO 2 converted within two years. The potential impacts of mineral precipitation and consequent changes on rock porosity, pore structure, pore size, and pore size distributions have likely been underestimated hitherto. Herein, we address these knowledge gaps using X-ray Micro Computed Tomography (XMT) to evaluate the pore network architecture of sidewall cores recovered two years after CO 2 injection. In the present study, we performed a detailed quantitative analysis of the CO 2 -reacted basalt cores by XMT imaging. Reconstructed 3D images were analyzed to study the distribution and volumetric details of porosity and carbonate nodules in the cores along with the various other phases, providing insight into paragenesis and carbonate growth mechanisms, including mineralogic/chemical zonation. Finally, these findings are being used to parametrize multiphase reactive transport models to predict the fate and transport of subsurface CO 2 , enabling scale-up to commercial-scale geologic carbon storage in basalts and other reactive mafic-ultramafic formations.

54 ENVIRONMENTAL SCIENCES↗

An externally and internally deformable, programmable lung motion phantom

Purpose: Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interior. Such designs do not adequately represent respiration because the thoracic anatomy deforms internally as well as externally. In order to create a closer approximation of respiratory motion, the authors describe the construction and experimental testing of an externally as well as internally deformable, programmable lung phantom. Methods: The outer shell of a commercially available lung phantom (RS-1500, RSD, Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A custom-made insert was designed using a piece of natural latex foam block. A motion platform was programmed with sinusoidal and ten patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam “diaphragm” that compressed/decompressed the phantom interior. Experimental characterization comprised of determining the reproducibility and the external–internal correlation of external and internal marker trajectories extracted from kV x-ray fluoroscopy. Experiments were conducted to illustrate three example applications of the phantom—(i) validating the geometric accuracy of the VisionRT surface photogrammetry system; (ii) validating an image registration tool, NiftyReg; and (iii) quantifying the geometric error due to irregular motion in four-dimensional computed tomography (4DCT). Results: The phantom correctly reproduced sinusoidal and patient-derived motion, as well as realistic respiratory motion-related effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.25 mm RMS error. The motion trajectories of internal and external radio-opaque markers as measured by fluoroscopy were found to be highly correlated (R > 0.95). Using the phantom, it was demonstrated that the motion trajectories of regions-of-interest on the surface as measured by VisionRT are highly consistent with corresponding fluoroscopically acquired surface marker trajectories, with RMS errors within 0.26 mm. Furthermore, it was shown that the trajectories of external and internal marker trajectories derived from NiftyReg deformation vector fields were within 1 mm root mean square errors comparing to trajectories obtained by segmenting markers from individual fluoro frames. Finally, it was shown that while 4DCT can be used to localize internal markers for sinusoidal motion with reasonable accuracy, the localization error increases significantly (by a factor of ∼2) in the presence of cycle-to-cycle variations that are observed in patient-derived respiratory motion. Conclusions: The authors have developed a realistic externally and internally deformable, programmable lung phantom that will serve as a valuable tool for clinical and investigational motion management studies in thoracic and abdominal radiation therapies.

60 APPLIED LIFE SCIENCES↗

Integrated Component-Specific Measurements to Develop Emission Factors for Compressors and Gas Gathering Lines

The Department of Energy (DOE) National Energy Technology Laboratory (NETL) and other critical stakeholders (e.g., U.S. Environmental Protection Agency (USEPA), state regulators, and industry) seek to more accurately characterize and quantify methane emissions from compressors and gathering lines within the Gathering and Boosting (G&B) segment of the natural gas system network. These efforts will reduce uncertainties in emissions estimates in USEPA’s current Green House Gas Inventory (GHGI) under their Greenhouse Gas Reporting Program (GHGRP). For this study, four G&B stations in the Gulf Coast Area were visited four times over the course of one year. Components were classified according to equipment and component type and emissions from select components were measured using multiple measurement technologies. The following major equipment types were considered: i) compressors, ii) separators, iii) dehydrators, iv) coalescers, v) slug catchers, vi) yard piping, vii) tanks, and viii) gathering lines. Individual components on each equipment type were further divided into the following main categories: i) connectors, ii) valves, iii) pressure relief valves (PRV), iv) meters, v) gauges, vi) regulators, vii) pneumatic device vents, and viii) compressor vents (e.g., distance piece vents [DPVs] and rod packing vents [RPVs]). Components were screened for the presence of leaks and venting emissions with an optical gas imaging (OGI) camera, and methane emission rates were measured using a microdilution high volume sampler. Downwind emissions were measured using an Open Path Fourier Transform Infrared (OP-FTIR) Spectrometer. Data were evaluated to assess correlation with site, equipment, time, and operational variables. Key findings and recommendations from the study include: A) Different counting methodologies can result in vastly different component counts, thus influencing total emissions calculations using Subpart W population EFs. A standard methodology should be adopted for classifying and counting components in order to minimize inconsistencies across studies and instruct stakeholders responsible for GHGI reporting. B) Results support current component subcategories listed in USEPA Subpart W, including the subdivision of connectors (flanged and “other”) and pneumatic device vents (intermittent, continuous low bleed, and continuous high bleed). C) Emission rates vary across sites and a relationship between higher emissions and compressor age was observed for some components. D) Component emission rates varied between field campaigns. The type of components contributing to overall measured emissions also varied among field campaigns. However, the emission rate variability was larger between different components (of the same category) than the variability in one component over the four field campaigns. Therefore, when calculating emission factors, it is not necessary to take repeat measurements to capture component variability. E) Measuring the emission rate of a sample for an extended period of time is not necessary to capture the average component emission rate. F) For reporting purposes, excluding liquid lines from site-wide screening may have a negligible effect on component-related emissions. However, from a site management perspective, malfunctioning components were not uncommon on liquid lines and contributed substantially to fugitive emissions at some sites. G) Population EFs, whether including or excluding liquid lines, were a conservative estimate of fugitive emissions. Leaker EFs consistently underestimated emissions at the field sites. Measurements at more sites, particularity sites in other areas of the country, need to be completed before determining the accuracy of EFs.

03 NATURAL GAS↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Large Area Telescope

The Large Area Telescope (LAT), one of two instruments on the Gamma-ray Large Area Space Telescope (GLAST) mission, is an imaging, wide field-of-view, high-energy pair-conversion telescope, covering the energy range from {approx}20 MeV to more than 300 GeV. The LAT is being built by an international collaboration with contributions from space agencies, high-energy particle physics institutes, and universities in France, Italy, Japan, Sweden, and the United States. The scientific objectives the LAT will address include resolving the high-energy gamma-ray sky and determining the nature of the unidentified gamma-ray sources and the origin of the apparently isotropic diffuse emission observed by EGRET; understanding the mechanisms of particle acceleration in celestial sources, including active galactic nuclei, pulsars, and supernovae remnants; studying the high-energy behavior of gamma-ray bursts and transients; using high-energy gamma-rays to probe the early universe to z {ge} 6; and probing the nature of dark matter. The components of the LAT include a precision silicon-strip detector tracker and a CsI(Tl) calorimeter, a segmented anticoincidence shield that covers the tracker array, and a programmable trigger and data acquisition system. The calorimeter's depth and segmentation enable the high-energy reach of the LAT and contribute significantly to background rejection. The aspect ratio of the tracker (height/width) is 0.4, allowing a large field-of-view and ensuring that nearly all pair-conversion showers initiated in the tracker will pass into the calorimeter for energy measurement. This paper includes a description of each of these LAT subsystems as well as a summary of the overall performance of the telescope.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Earth Abundant High Temperature Materials for Radioisotope Power Conversion System

Advances in high temperature thermoelectric materials were made and published. Two major developments are out lined in this final report. Alkaline earth Zintl phases represent the starting point of a series of compounds selected for development due to their high abundance as the supply chain and as the availability of certain rare earths (i.e. Yb) are limited and can be difficult to obtain. A new Zintl phase, Ca 14 MnSb 11-x Sn x , where Sb is replaced by Sn resulting in changes to the band structure and properties. The structures are investigated by powder diffraction and samples consolidated into fully dense pellets for thermoelectric measurements. The band structure of a reasonable structure, Ca 14 MgSb 7 Sn 4 , is calculated in order to better understand the properties. These Sn containing phases show improved thermoelectric properties over Ca 14 MgSb 11 by increasing the Seebeck while decreasing resistivity without significant impact to the already low thermal conductivity. In addition, a composite phase of Yb 14 MgSb 11 was investigated. Composite phases have been shown to improve both the thermoelectric efficiency and mechanical properties of materials. Here we demonstrate an improved thermoelectric figure of merit, power factor, and mechanical properties for the high-temperature p-type Zintl phase Yb 14 MgSb 11 . Composites with 0, 1, 2, 3, 4, 6, 8 volume % 6 – 10 µm reduced Fe powder were prepared via a fast, scalable mechanical milling and spark plasma sintering procedure. Powder X-ray diffraction, scanning electron microscopy, and transmission electron microscopy show that Fe is not incorporated into the Yb 14 MgSb 11 structure. First order reversal curves and scanning electron microscopy images show that the Fe inclusions are larger and closer together with increasing Fe content. Thermogravimetric and differential scanning calorimetry show that the composites are stable up to 1273 K. The elastic constants of the 8 volume % Fe composite were measured by resonant ultrasound spectroscopy and show that Yb 14 MgSb 11 becomes stiffer with increasing Fe volume % and SEM after indentations show crack arresting occurs at the Fe interface. Thermoelectric properties on dense pellets are measured from 300 K – 1273 K. The thermoelectric power factor (PF= $\frac{S^2}{ρ}$) increases with increasing Fe content, with the 8 volume % Fe resulting in 40% higher PF than pristine Yb 14 MgSb 11 . The increase in PF is attributed to a systematic reduction in electrical resistivity. Peak thermoelectric figure of merit (zT= ($\frac{S^2T}{κρ}$) is observed at 3 volume % Fe, an 11% improvement in zT compared to Yb 14 MgSb 11 . Yb 14 MgSb 11 composites with Fe are compatible with Ce 0.9 Fe 3.5 Co 0.5 Sb 12 for thermoelectric generator couple segmentation.

30 DIRECT ENERGY CONVERSION↗

Path Network Recovery Using Remote Sensing Data and Geospatial-Temporal Semantic Graphs

Remote sensing systems produce large volumes of high-resolution images that are difficult to search. The GeoGraphy (pronounced Geo-Graph-y) framework [2, 20] encodes remote sensing imagery into a geospatial-temporal semantic graph representation to enable high level semantic searches to be performed. Typically scene objects such as buildings and trees tend to be shaped like blocks with few holes, but other shapes generated from path networks tend to have a large number of holes and can span a large geographic region due to their connectedness. For example, we have a dataset covering the city of Philadelphia in which there is a single road network node spanning a 6 mile x 8 mile region. Even a simple question such as "find two houses near the same street" might give unexpected results. More generally, nodes arising from networks of paths (roads, sidewalks, trails, etc.) require additional processing to make them useful for searches in GeoGraphy. We have assigned the term Path Network Recovery to this process. Path Network Recovery is a three-step process involving (1) partitioning the network node into segments, (2) repairing broken path segments interrupted by occlusions or sensor noise, and (3) adding path-aware search semantics into GeoQuestions. This report covers the path network recovery process, how it is used, and some example use cases of the current capabilities.

47 OTHER INSTRUMENTATION↗

Acute Superior Mesenteric Venous Thrombosis: Transcatheter Thrombolysis and Aspiration Thrombectomy Therapy by Combined Route of Superior Mesenteric Vein and Artery in Eight Patients

PurposeTo assess the feasibility, effectiveness, and safety of catheter-directed thrombolysis and aspiration thrombectomy therapy by combined route of superior mesenteric vein and artery (SMV+SMA) for acute superior mesenteric venous thrombosis (ASMVT).MethodsThis retrospective study reviewed eight ASMVT patients with transcatheter direct thrombolysis and aspiration thrombectomy therapy via SMV and indirect thrombolysis via SMA during a period of 14 months. The demographics, etiology, risk factors, therapeutic effect, complications, mortality, and follow-up of the study population were assessed. Anatomic and imaging classification of location and extent of thrombus at diagnosis and degree of thrombus lysis were described.ResultsTechnical success was achieved with substantial improvement in symptoms and thrombus resolution after thrombolytic therapy in all patients. The local urokinase infusion by SMA and SMV was performed for 5–7 (6.13 ± 0.83) and 7–15 (12 ± 2.51) days. Anticoagulation was performed catheter-directed and then orally throughout hospitalization and after discharge. Four patients required delayed localized bowel resection after thrombolytic therapy with no death. Thrombolytic therapy was not interrupted despite minor bleeding at the puncture site in two patients and sepsis in another two postoperatively. Nearly complete removal of thrombus was demonstrated by contrast-enhanced CT scan and portography before discharge. Patients were discharged in 10–27 (19.25 ± 4.89) days after admission. No recurrence developed during the follow-up of 10–13 (12.13 ± 0.99) months.ConclusionsCatheter-directed thrombolytic and aspiration therapy via SMV+SMA is beneficial for ASMVT in avoiding patient death, efficient resolving thrombus, rapid improving symptoms, reversing extensive intestinal ischemia, averting bowel resection, or localizing infarcted bowel segment and preventing short bowel syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of impeller type on silica sol formation in laboratory scale agitated tank

The multiphase polymerization reaction of the silica sol formation produced from silicic acid and potassium hydroxide solutions in laboratory scale agitated tank was studied. The reactor is equipped with four segmental baffle and top entering impeller. The inside diameter of reactor is 9 cm, the baffle width is 0.9 cm, and the impeller position is 3 cm from tank bottom. The diameter of standard six blades Rushton and three blades marine propeller impellers are 5 cm. The silicic acid solution was made from 0.2 volume fraction of water glass (sodium silicate) solution in which the sodium ion was exchanged by hydrogen ion from cation resin. The reactor initially filled with 286 ml silicic acid solution was operated in semi batch mode and the temperature was kept constant in 60 °C. The 3 ml/minute of 1 M potassium hydroxide solution was added into stirred tank and the solution was stirred. The impeller rotational speed was varied from 100 until 700 rpm. This titration was stopped if the solution in stirred tank had reached the pH of 10-The morphology of the silica particles in the silica sol product was analyzed by Scanning Electron Microscope (SEM). The size of silica particles in silica sol was measured based on the SEM image. The silica particle obtained in this research was amorphous particle and the shape was roughly cylinder. The flow field generated by different impeller gave significant effect on particle size and shape. The smallest geometric mean of length and diameter of particle (4.92 µm and 2.42 µm, respectively) was generated in reactor with marine propeller at 600 rpm. The reactor with Rushton impeller produced particle which the geometric mean of length and diameter of particle was 4.85 µm and 2.36 µm, respectively, at 150 rpm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cerebral Arteries Extraction using Level Set Segmentation and Adaptive Tracing for CT Angiography

We propose an approach for extracting cerebral arteries from partial Computed Tomography Angiography (CTA). The challenges of extracting cerebral arteries from CTA come from the fact that arteries are usually surrounded by bones and veins in the lower portion of a CTA volume. There exists strong intensity-value overlap between vessels and surrounding objects. Besides, it is inappropriate to assume the 2D cross sections of arteries are circle or ellipse, especially for abnormal vessels. The navigation of the arteries could change suddenly in the 3D space. In this paper, a method based on level set segmentation is proposed to target this challenging problem. For the lower portion of a CTA volume, we use geodesic active contour method to detect cross section of arteries in the 2D space. The medial axis of the artery is obtained by adaptively tracking along its navigation path. This is done by finding the minimal cross section from cutting the arteries under different angles in the 3D spherical space. This method is highly automated, with minimum user input of providing only the starting point and initial navigation direction of the arteries of interests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗