Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Technology Solutions for New and Existing Homes Case Study: Field Trial of an Aerosol-Based Enclosure Sealing Technology

This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak.

aerosol sealing↗

Mockup Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to be brought easily within conditioned space via interior partition walls. Centrally locating the air hander unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives an equal amount of airflow, regardless of the duct position on the box. Furthermore, within a reasonable set of length restrictions, each duct continues to receive similar airflow. The design method uses an additive approach to reach the total needed zonal airflow. Once the cubic feet per minute needed to satisfy the thermal load of a zone has been determined, the total number of duct runs to a zone can be calculated by dividing the required airflow by the standard airflow from each duct. The additive approach greatly simplifies the design effort and reduces the potential for duct design mistakes to be made. Measured results indicate that this plenum design can satisfy the heating load. However, the total airflow falls short of satisfying the cooling load in a hypothetical building. Static pressure inside the plenum box of 51.5 Pa limited the total airflow of the attached mini-split heat pump blower, thus limiting the total thermal capacity. Fan energy consumption is kept to 0.16 to 0.22 watt/CFM by using short duct runs and smooth duct material.

air distribution↗

Building America Case Study: Occupant Comfort from a Mini-Split Heat Pump, San Antonio, Texas

IBACOS worked with builder Imagine Homes to evaluate the performance of an occupied new construction test house following construction of the house in the hot, humid climate of San Antonio, Texas. The project measures the effectiveness of a space conditioning strategy using a multihead mini-split heat pump (MSHP) system in a reduced-load home to achieve acceptable comfort levels (temperature and humidity) and energy performance. IBACOS collected long-term data and analyzed the energy consumption and comfort conditions of the occupied house after one year of operation. Although measured results indicate that the test system provides comfort both inside and outside the ASHRAE Standard 55-2010 range, the occupants of the house claimed both adequate comfort and appreciation of the ease of use and flexibility of the installed MSHP system. IBACOS also assisted the builder to evaluate design and specification changes necessary to comply with Zero Energy Ready Home, but the builder chose to not move forward with it because of concerns about the 'solar ready' requirements of the program.

30 DIRECT ENERGY CONVERSION↗

IN2 Profile: 7AC Technologies Takes High-Efficiency Air Conditioning to a New Level

As part of the Wells Fargo Innovation Incubator (IN²) program, 7AC Technologies has developed a liquid desiccant evaporative technology that will result in a 40-50% energy savings for commercial buildings. The IN² program launched in October 2014 and is part of Wells Fargo’s 2020 Environmental Commitment to provide $100 million to environmentally-focused nonprofits and universities. The goal is to create an ecosystem that fosters and accelerates the commercialization of promising commercial buildings technologies that can provide scalable solutions to reduce the energy impact of buildings. According to the Department of Energy, nearly 40 percent of energy consumption in the U.S. today comes from buildings at an estimated cost of $413 billion.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Standard- Versus High-Velocity Air Distribution in High-Performance Townhomes, Denver, Colorado

IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore the small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tune-Up Your Fan Systems for Improved Performance

Fans are used extensively in commercial buildings and represent approximately 6% of total energy consumed by commercial buildings. The U.S. Department of Energy (DOE) estimates that fans in commercial buildings consume 158 billion kWh of electricity annually. Maintaining fan systems in proper condition provides energy savings and ensures a comfortable and healthy environment. While many fan systems have significant energy savings opportunities available through improvements in fan selection, system design, and operational practices, it is not always apparent when a fan system needs maintenance or what opportunities are available for improvements. This resource is designed for facility managers and maintenance staff to provide easy-to-implement actionable guidance on fan efficiency measures for existing ducted air systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mind the Gap: Summary of Window Residential Retrofit Solutions

Improving the insulation, solar heat gain, and infiltration characteristics of windows in a home has the potential to significantly improve the overall thermal performance by reducing heat transfer through the window and also by decreasing infiltration of outdoor air into the home. As approximately 43% of existing homes still have single-pane clear windows (~50 million houses) and millions of other homes have only double-pane clear windows (Cort 2013), improving window performance also presents a significant opportunity for energy savings in the residential sector. Today, various energy-saving window retrofit opportunities are available to homeowners, ranging from window coverings and storm panels to highly-insulating triple-pane R-5 window replacements. Many of these technologies have been evaluated in the field, in the “Lab Homes” at Pacific Northwest National Laboratory, and through modeling to prove their cost-effectiveness and performance in different climate regions. Recently, the Pacific Northwest’s Regional Technical Forum approved a utility measure for low- emissivity storm windows based on such data. This action represents a watershed moment for increasing the variety and prevalence of fenestration options in utility programs, especially for the low-income demographic. This paper will review various window retrofit options, the most recent field test and modeling data regarding their performance and cost-effectiveness, and discuss future rating efforts. This information is useful for utilities and energy-efficiency program managers to help effectively implement incentive measures for these technologies.

HVAC↗

Novel, Simplified Air Delivery System Design Gets Commercialized

Typical air delivery systems require contractors to design systems that are complex, difficult to integrate into the framing and structural components of a home, and often do not meet the optimization demands of newer energy-efficient homes. This complex process can be a burden to already strained construction labor costs. However, a new technology simplifies duct system design to improve comfort and eliminate sources of installation error for residential air delivery systems.

30 DIRECT ENERGY CONVERSION↗

The Cost of Comfort in Your Home: Peak-Time Energy and Cost Savings from Setpoint Adjustment of Space Heating and Cooling

This poster presents the tradeoff between energy costs and thermal comfort in homes. Residential heating and cooling systems use a thermostat control to maintain a comfortable temperature range, but tighter temperature control leads to higher annual energy costs. We estimate the impact of temperature setpoint adjustment on annual energy costs using a residential building model developed at NREL. We show that increasing the allowable temperature range reduces energy costs in all five of the climate zones in the U.S. Annual costs reduced by about $100, with larger savings in areas with more heating and/or cooling loads.

30 DIRECT ENERGY CONVERSION↗

ACE Learning Series - Enforcement Toolkit

The Building Energy Codes Program (BECP) developed this toolkit to help the enforcement community achieve higher levels of compliance with building energy codes. Although this toolkit is not intended for use by designers, developers, homeowners or renters, building owners, or building operators, it may provide those individuals some insight into the issues facing the enforcement community.

IECC, building information modeling, HVAC, new con↗

Building Energy Codes: Air Leakage Guide

Meeting the Air Leakage Requirements of the 2012 IECC provides a resource for understanding the requirements in the 2012 IECC to limit air leakage through a building's thermal envelope, and guidance on how to meet these requirements. It also provides information from Building America's Air Sealing Guide, best practices, and case studies on homes that currently are meeting the requirements. Finally, it provides information critical to understanding how to conduct a required blower door test to assess the actual air leakage rate of the home, report the results, and validate energy code compliance. To enhance the connection of the information to the relevant codes, the 2012 IECC and relevant 2012 International Residential Code requirements are referenced throughout the guide.

Energy efficiency, home comfort, building envelope↗

Implementing High-Efficiency Rooftop Units in Leased Buildings

This case study details a project completed by Efficiency Vermont to install 66 high-efficiency rooftop unit replacements on a large 140,000-square-foot office building, which realized 163 kW in electricity demand reduction and $93,000 annual utility cost savings.

utility, project financing, office building, comme↗

Smart Monitoring and Diagnostic System (SMDS) for RTUs

This case study describes the Smart Monitoring and Diagnostic System (SMDS) which is a low-cost technology that helps building owners and managers keep rooftop air conditioner and heat pump units (RTUs) operating properly at peak efficiency. Through the Better Buildings Alliance, a field demonstration was conducted at four sites using two SMDS prototypes. This case study provides a summary of the field demonstration results.

HVAC, Rooftop Unit, RTU, commercial, retail, air c↗

Walgreens RTU Replacement Program: Advanced RTU Campaign

This case study describes Walgreens’ program to strategically retire RTUs prior to failure and replace them with high-efficiency units in 150 stores, which realized more than $1 million in savings from material and labor budgets by right-sizing equipment and optimizing replacements, compared to an emergency replace upon failure mode.

rooftop unit, RTU, replace, replacement, retail, H↗

Field Evaluation of a High-Efficiency RTU

This case study describes the development and demonstration of a specification for high-performance rooftop air conditioning units with capacity ranges between 10 and 20 tons. It is focused on Daikin’s Rebel RTU, which was recognized by DOE as the first to meet its RTU Challenge specifications. The demonstration took place at two Publix grocery stores located in New Smyrna Beach and Port Orange, Florida.

rooftop unit, RTU, specification, high performance↗

Rooftop Unit Replacement: adidas RTU Planned Replacement Program

This case study describes adidas’ successful implementation of a planned RTU replacement program designed to standardize equipment features and reduce costs, enabling the company to streamline acquisitions and ensure each location had the required equipment.

rooftop unit, RTU, replacement, retail, HVAC, air ↗