Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fast timing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Direct-Y: Fast Acquisition of the GPS PPS Signal

The NAVSTAR Global Positioning System (GPS) provides positioning and time information to military users via the Precise Positioning Service (PPS) which typically allows users a significant margin of precision over the commercially available Standard Positioning Service (SPS), Military sets that rely on first acquiring the SPS Coarse Acquisition (C/A) code, read from the data message the handover word (HOW) that provides the time-of-signal transmission needed to acquire and lock onto the PPS Y-code. Under extreme battlefield conditions, the use of GPS would be denied to the warfighter who cannot pick up the un-encrypted C/A code. Studies are underway at the GPS Joint Program Office (JPO) at the Space and Missile Center, Los Angeles Air Force Base that are aimed at developing the capability to directly acquire Y-code without first acquiring C/A code. This paper briefly outlines efforts to develop 'direct-Y' acquisition, and various approaches to solving this problem. The potential ramifications of direct-Y to military users are also discussed.

Namoos, Omar M.↗

IMPACT: Design of Integrated Multiphysics Producible Additive Components for Turbomachinery

The overall objective of the IMPACT program was to enable a dramatic reduction in design maturation time for an additive hot-section turbomachinery component through the following: • A fast crack-risk producibility surrogate model generated from machine learning applied to additive process simulation data generated via exascale computing, • Linking this surrogate model to multi-physics topology optimization (TO) to enable the creation of producible, near-optimal structural/thermal designs for additive hot-section components, • Maturing this toolset to reduce hot-section component design-for-manufacturing iterations by a large fraction, and eventually, • Using these tools to develop more efficient gas turbines in much shorter design cycle times.

42 ENGINEERING↗

Color as a tool for quantitative analysis of heterogeneous polymer degradation

Polymers are widely used industry, but degrade due to environmental conditions, such as elevated temperature or radiation. The degradation of polymers is dominated oxidation in oxygenated environments. Such oxidation is commonly referred to as thermal-oxidation or photo-oxidation and in many situations is heterogeneous through thickness of the polymer. While heterogeneous oxidation of polymers is a common phenomenon, the effect on the lifetime of polymers is not well understood as methods to evaluate such oxidation are time consuming and challenging to implement. Here we show a novel method for quantitative evaluation of heterogeneous oxidation in polymers using a fast and accurate color approach. The proposed color approach was observed to improve the efficiency of obtaining heterogenous oxidation profiles in half the time of common approaches, such as indention or Fourier transform infrared spectroscopy. Furthermore, the method was found to produce trends similar to that observed using common approaches and the applicability of the method was verified by mapping oxygen concentration through thickness using energy dispersive X-ray spectroscopy. Lastly, the utility of the proposed method was demonstrated through the generation of an oxidation design space, which is envisioned to assist with designing experiments towards estimation of polymer lifetime. Finally, we anticipate this work to be a starting point for further evaluation of heterogeneous oxidation in polymers using optical properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biomimetic Optical Sensor for Real-Time Aircraft Wing Deflection Measurement

Reducing the environmental impact of aviation is a primary goal of NASA aeronautics research. One approach to achieve this goal is to build lighter weight aircraft, which presents complex challenges due to a corresponding increase in structural flexibility. Wing flexibility can adversely affect aircraft performance from the perspective of aerodynamic efficiency and safety. Knowledge of the wing position during flight can aid active control methods designed to mitigate problems due to increased wing flexibility. Current approaches to measuring wing deflection, including strain measurement devices, accelerometers, or GPS solutions, and new technologies such as fiber optic strain sensors, have limitations for their practical application to flexible aircraft control. Hence, it was proposed to use a bio-mimetic optical sensor based on the fly-eye to track wing deflection in real-time. The fly-eye sensor has several advantages over conventional sensors used for this application, including light weight, low power requirements, fast computation, and a small form factor. This paper reports on the fly-eye sensor development and its application to real-time wing deflection measurement.

Frost, Susan A.↗

Modeling the Dynamics of Energetic Protons in Earth's Inner Magnetosphere

Recently, Van Allen Probes data have revealed the interesting energy-dependent dynamics of energetic protons in Earth's inner magnetosphere. To quantify the role of radial diffusion and charge exchange to the observed energy-dependent dynamics of ring current protons, a 1D radial diffusion model with charge exchange loss is implemented. The observed proton flux over the long-term period of November 2012 to September 2013 is first converted to phase space densities, which are then simulated by our model driven by an outer boundary condition at L* = 5.5 derived from the data. The simulation results show that our model generally captures the transport and acceleration of energetic protons at μ = 30, 50, and 80 MeV/G and K = 0.11 G 1/2 R E , suggesting that radial diffusion is the dominant source mechanism for >75 keV protons at L* = 3.5–5.5. Additionally, the observed fast decay of protons at lower μ and slow decay at higher μ are well captured by the model, demonstrating the dominant role of charge exchange in explaining the observed energy-dependent proton decay. For higher μ protons, prompt losses of protons on the time scale of hours are observed over a wide range of L*, which is too fast to be explained by charge exchange. Some of the prompt losses at high L* regions are reproduced by the model with outward radial diffusion to the outer boundary. However, many prompt losses observed at lower L* regions are not captured by the model, which could be due to other loss mechanisms including electromagnetic ion cyclotron wave scattering and field line curvature scattering.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of rf-induced temporal jitter in ultrafast electron diffraction

A significant contribution to the temporal resolution of an ultrafast electron diffraction (UED) instrument is arrival time jitter caused by amplitude and phase variation of radio-frequency (rf) cavities. In this paper, we present a semianalytical approach for calculating rf-induced temporal jitter from klystron and rf cavity parameters. Our approach allows fast estimation of temporal jitter for MeV-UED beamlines and can serve as a virtual timing tool when shot-to-shot measurements of rf amplitude and phase jitters are available. A simulation study for the SLAC MeV-UED instrument is presented, and the temporal resolution of several beamline configurations is compared.

47 OTHER INSTRUMENTATION↗

Asymmetric Lithium Extraction and Insertion in High Voltage Spinel at Fast Rate

Spinel-structured ordered-LiNi 0.5 Mn 1.5 O 4 (o-LNMO) has experienced a resurgence of interest in the context of reducing scarce elements such as cobalt from lithium-ion battery. O-LNMO undergoes two two-phase reaction at slow rates. However, it is not known if such phenomenon also applies at fast rates. Herein, we investigate the rate-dependent phase transition behavior of o-LNMO through in operando time-resolved X-ray diffraction. The results indicate that a narrow region of solid solution reaction exists for charge and discharge at both slow and fast rate. The overall phase transition is highly asymmetric at fast rates. During fast charge, it is a particle-by-particle mechanism resulting from asynchronized reaction among the particles. Finally, during fast discharge, it is likely a core-shell mechanism involving transition from Li 0+x Ni 0.5 Mn 1.5 O 4 to Li 1+x Ni 0.5 Mn 1.5 O 4 in the outer layer of particles. The Li 0.5 Ni 0.5 Mn 1.5 O 4 phase is suppressed during fast discharge and only appears through Li redistribution upon relaxation.

25 ENERGY STORAGE↗

Comparison of Feschenko BSM and Fast Faraday Cup with Low Energy Ion Beams

A comparison between Fast Faraday Cup and Feschenko longitudinal bunch shape detectors was recently performed at HELIAC Advanced Demonstrator beamline at GSI. Feschenko bunch shape monitor (BSM) uses the time to space conversion by means of secondary electrons emitted from a wire correlated to a rf deflector, while the fast Faraday cup (FFC) measures the deposited charge in a cup geometry matched to 50 Ohm. The FFC design aims to minimize the bunch shape dilution due to field polarization and secondary electrons produced on irradiation. An He¹⁺ with 100 µA average current and 1.4 MeV/u kinetic energy is utilized for this comparison. A buncher upstream of the detectors was operated to focus the beam longitudinally. The results are discussed in this contribution.

43 PARTICLE ACCELERATORS↗

Fast Simulation of the NICER Instrument

The NICER mission uses a complicated physical system to collect information from objects that are, by x-ray timing science standards, rather faint. To get the most out of the data we will need a rigorous understanding of all instrumental effects. We are in the process of constructing a very fast, high fidelity simulator that will help us to assess instrument performance, support simulation-based data reduction, and improve our estimates of measurement error. We will combine and extend existing optics, detector, and electronics simulations. We will employ the Compute Unied Device Architecture (CUDA2) to parallelize these calculations. The price of suitable CUDA-compatible multi-gigaflop cores is about $0.20/core, so this approach will be very cost-effective.

gEDA↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Real-time capable modeling of ICRF heating on NSTX and WEST via machine learning approaches

Abstract A real-time capable core Ion Cyclotron Range of Frequencies (ICRF) heating model on NSTX and WEST is developed. The model is based on two nonlinear regression algorithms, the random forest ensemble of decision trees and the multilayer perceptron neural network. The algorithms are trained on TORIC ICRF spectrum solver simulations of the expected flat-top operation scenarios in NSTX and WEST assuming Maxwellian plasmas. The surrogate models are shown to successfully capture the multi-species core ICRF power absorption predicted by the original model for the high harmonic fast wave and the ion cyclotron minority heating schemes while reducing the computational time by six orders of magnitude. Although these models can be expanded, the achieved regression scoring, computational efficiency and increased model robustness suggest these strategies can be implemented into integrated modeling frameworks for real-time control applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗

Real-Time, Single-Step Bioassay Using Nanoplasmonic Resonator With Ultra-High Sensitivity

A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

Zhang, Xiang↗

Technology Transfer Excellence Award NTXBio

While a scientist at Los Alamos National Laboratory, Dr. Alex Koglin developed two compounds to create a better vaccine for Tuberculosis (TB). In 2015, Dr. Koglin took an entrepreneurial leave of absence from the Laboratory to start NTXBio, LLC. His objective was to develop and commercialize a TB vaccine based on two compounds he created while a scientist at the Los Alamos. In 2018, a total of 1.5 million people died from TB. According to the World Health Organization TB is the leading infectious disease resulting in death worldwide. Approximately one-quarter of the world’s population is infected with mycobacterium tuberculosis, the bacteria that causes TB. Dr. Koglin non-exclusively licensed the two compounds from Los Alamos and began further development of the technology in collaboration with the Government of South Africa and universities to address the need for a vaccine to prevent TB. In their research and development of the compounds there was no evidence of cross resistance between other bacteria and the bacteria that causes TB. The compounds were tested in mouse models and demonstrated they can treat TB. Also, the tests have not shown any of the massive side effects that the current treatments for TB are showing. The company started production of the compounds using current manufacturing processes. Using these processes NTXBio could not produce the compounds at a reasonable price to be available for patients in third world countries. The company shifted to developing a new methodology “invitro synthetic biology” that can increase the production of these compounds and other vaccine molecules in a more affordable way. Dr. Koglin’s startup NTXBio is working to positively influence and secure the world vaccine supply by developing rapid on-demand production of the full spectrum of protein vaccines. Starting with the TB vaccine and advancing to common childhood vaccines, emergency and experimental vaccines such as those needed for COVID-19. NTXBio is capable of accelerated prototyping and manufacturing with increased purity and greater stability while reducing both cost and production time. The newly developed production methodology can be applied to not only the TB compounds licensed from Los Alamos, but also to their compounds that advance vaccine production for other diseases. Their technology produces vaccines fast enough to be fully deployable in areas without the need of specialized storage conditions and response times.

60 APPLIED LIFE SCIENCES↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expansion of the Fast Neutron Hodoscope at TREAT to Support Fuel Safety Experiments

In 2024 the Fuel Motion Monitoring System (FMMS), or Hodoscope, at the Transient Reactor Test Facility, is being expanded from 96 viewing channels to 192 viewing channels, effectively doubling the FMMS field of view. Here, this increase in capability will allow the FMMS to support larger scale fuel tests, encompassing height-of-core test devices, test devices with multi-pin fuel assemblies, and test devices with recirculating coolant flow. Work supporting the expansion included refurbishing 96 additional proton recoil scintillator (PRS) detectors, doubling the data acquisition system (DAS) installed architecture, improving time synchronization in the DAS, and new research to measure the PRS detector energy-dependent, fast-neutron detection efficiency. In addition, laboratory activities have produced an improved benchtop testing capability for assessing the DAS, time synchronization, and external start triggering, along with an updated capability to scan PRS detectors to develop a preliminary flat-field normalization prior to deployment to TREAT.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Solar burst with millimetre-wave emission at high frequency only

The first high sensitivity and high time-resolution observations of a solar burst taken simultaneously at 90 GHz and at 30 GHz are presented. These identify a unique impulsive burst on May 21, 1984 with fast pulsed emission that was considerably more intense at 90 GHz than at lower frequencies. Hard X-ray time structures at energies above 25 keV were almost identical to the 90 GHz structures to better than 1 s. The structure of the onset of the major 90 GHz burst coincided with the hard X-ray structure to within 128 ms. All 90 GHz major time structures consisted of trains of multiple subsecond pulses with rise times as short as 0.03 s and amplitudes that were large compared with the mean flux. When detectable, the 30 GHz subsecond pulses had smaller relative amplitude and were in phase with the corresponding 90 GHz pulses.

Kaufmann, P.↗

When to vaccinate for seasonal influenza: check the peak forecast

Background Seasonal influenza infects 5-20% of people every year in the United States, resulting in hospitalizations, deaths, and adverse economic impacts. To mitigate these impacts, influenza vaccines are developed and distributed annually; however, growing evidence suggests that vaccine effectiveness (VE) wanes over the course of a flu season. Delaying influenza vaccination for older adults has attracted attention as a potential public health strategy. However, given the uncertainties in seasonal peak, vaccine effectiveness, and waning rates, postponing vaccination could also lead to increased morbidity, motivating an evaluation of a range of potential scenarios. The aim of this study was to investigate favorable age group-specific vaccination schedules that could lead to the greatest disease burden reduction. Methods We systematically investigated a broad range of vaccination start times for five age groups under six combinations of initial effectiveness and waning rates, based on influenza cases and vaccine uptake data from 10 influenza seasons. We defined the most favorable vaccination schedule as the one that resulted in the greatest reduction in disease burden. Results In scenarios with fast waning, all age groups benefit from delaying vaccination regardless of initial VE and peak timing. In scenarios with slower waning, results are mixed. For the ≥65 group, high initial VE and slow waning suggests that in early-peaking seasons, early vaccination most effectively reduces disease burden, while in late-peaking seasons delaying vaccination is most effective. For the ≥65 group in medium and low initial VE, and slow waning scenarios, delaying vaccination appears to prevent the greatest number of cases, regardless of whether the season peaks early or late. Conclusion The most favorable vaccination schedule is sensitive to changes in initial VE, waning rate, and peak timing. Given estimates of these quantities from statistical and immunological models and observations, our methods can inform vaccination recommendations in order to most effectively reduce the annual disease burden caused by seasonal influenza. Specifically, accurate peak timing forecasts for the upcoming season have the potential to guide decisions on when to vaccinate.

59 BASIC BIOLOGICAL SCIENCES↗