Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAT PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Design of evaporator of spacelab refrigerator/freezer

An Evaporator has been designed for NASA-Johnson Space Center Life Sciences to conduct experiments in Spacelab mission SLS-1 using different samples such as blood, urine, human tissues etc. Two units will fly - one as a Refrigerator (4 C) and the other as a Freezer (-22 C). The evaporator tube is dip brazed on a grooved flat plate. Aluminum heat sink is dip brazed on the other side of the plate. Freon R5O2 is pumped through the tube and air is circulated over the finned surface to transfer heat. As freon 5O2 is considered toxic, the whole freon tube is covered with an evaporator cover to contain any freon leakage to avoid exposure to crew members. This containment is under vacuum and this pressure is monitored along with the freon pressure to determine freon leakage so that necessary steps can be taken to stop contamination of the spacelab air. An stress analysis has been done and it is found to have adequate safety margin to meet the requirements of NASA safety and reliability standards.

Hye, A.↗

The effect of aerodynamic and structural detuning on turbomachine supersonic unstalled torsional flutter

The effects of alternate-blade structural detuning and adjacent-blade alternate-circumferential-spacing aerodynamic detuning on the supersonic unstalled torsional flutter stability of a turbomachine rotor are investigated analytically. An unsteady aerodynamic model employing influence coefficients is constructed for the case of a flat-plate-airfoil cascade in torsion-mode harmonic oscillation in a supersonic inviscid isentropic adiabatic irrotational perfect-gas inlet flow with a subsonic leading-edge locus. The influence coefficients and equations of motion are derived; the model is verified by applying it to the 12-blade cascade-B flow geometry studied by Verdon and McCune (1975); and the results are presented graphically. It is found that the rotor can be stabilized over the entire reduced frequency range by applying a combination of structural and aerodynamic detuning as the passive flutter-control mechanism.

Hoyniak, D.↗

Determination of hot-spot susceptibility of multistring photovoltaic modules in a central-station application

Part of the effort of the Jet Propulsion Laboratory (JPL) Flat-Plate Solar Array Project (FSA) includes a program to improve module and array reliability. A collaborative activity with industry dealing with the problem of hot-spot heating due to the shadowing of photovoltaic cells in modules and arrays containing several paralleled cell strings is described. The use of multiparallel strings in large central-station arrays introduces the likelihood of unequal current sharing and increased heating levels. Test results that relate power dissipated, current imbalance, cross-strapping frequency, and shadow configuration to hot-spot heating levels are presented. Recommendations for circuit design configurations appropriate to central-station applications that reduce the risk of hot-spot problems are offered. Guidelines are provided for developing hot-spot tests for arrays when current imbalance is a threat.

Gonzalez, C. C.↗

Two dimensional and axisymmetric heat transfer results with the CSCM upwind implicit algorithm

The single level conservative supra characteristic method (CSCM-S) is an upwind implicit method that is very robust and in a single level relaxation format makes efficient use of computer resources, and is very rapidly convergent. These factors render the unconditionally stable algorithm a useful compromise between Parabolized Navier-Stokes methods and two level linearized implicit time dependent methods and, thus, the method is very attractive for multidimensional Navier-Stokes problems. In this paper the heat transfer prediction capabilities of the CSCM schemes for flat plate, nozzle, blunt cone and bluff body flows are reported for the first time. Results are compared with available experimental heat transfer measurements.

Bardina, J.↗

Optimum configuration of high-lift aeromaneuvering orbital transfer vehicles in viscous flow

The results of an analysis to determine the geometrical configuration of an aeroassisted transfer vehicle with a high lift-to-drag ratio (L/D) are described and the constraints imposed on this type of entry vehicle are considered. The aerodynamic characteristics of three configurations, a flat-plate delta wing, a truncated straight cone, and a truncated bent biconic are compared. The effect of viscosity is included in the analysis which examines the rounding of the sharp leading edges. It is shown that, under the constraints of carrying a given volume in the dead air region, the values of L/D are similar for each configuration and that a small blunt leading edge only slightly affects each vehicle's aerodynamic performance, causing less than a 5 percent drop in L/D. The truncated bent biconic is found to be the only configuration that provides the necessary stabilizing moments.

Davies, C. B.↗

Effects of non-uniform velocity profiles on dual jets in a crossflow

The interaction between engine exhaust jets and the freestream affects the aerodynamic and stability characteristics of VTOL aircraft during the transition from hover to forward flight. This interaction is often modeled as a simple uniform jet issuing from a flat plate into a subsonic crossflow. The distribution of pressures induced by the jet on the surface of the plate can be used to predict the lift loss and pitching moment for a full-scale aircraft. The uniform jet model has limitations because an actual turbofan engine generates a rather nonuniform exit velocity profile. The purpose of this work is to study the effect of a nonuniform velocity profile on the surface pressure distribution. The mutual interaction of dual jets also is investigated in side-by-side and tandem configurations. Detailed pressure distributions are presented for two jet-to-freestream velocity ratios of 2.2 and 4.0. One important finding is that a nonuniform jet with a high velocity periphery and a low velocity core has a higher effective velocity ratio than a uniform jet with the same mass flow.

Moore, C. L.↗

Upwind relaxation algorithms for the Navier Stokes equations

The development of upwind relaxation algorithms for obtaining efficient steady-state solutions to the compressible Navier-Stokes equations is described. The method is second-order accurate spatially and naturally disipative, using third-order flux splitting of the pressure and convective terms and second-order central differencing for shear and heat flux terms. A line Gauss-Seidel relaxation approach, shown to be unconditionally stable for model convection and diffusion equations, is used. The algorithm is demonstrated for several flows using the thin-layer form of the equations, including the problem of shock-induced separation over a flat plate.

Thomas, J. L.↗

Heat transfer and turbulence measurements of a film-cooled flow over a convexly curved surface

Heat transfer and hydrodynamic boundary layer measurements were made in a turbulent boundary layer on a convex surface with 13 rows of injection. Both full- and partial-coverage cases were tested for three blowing ratios: 0.2, 0.4, and 0.6. Heat transfer results are discussed in terms of Stanton number with injection air temperature equal to wall temperature. In the blown region, for both m (blowing ratio) = 0.2 and 0.4, the local response of the boundary layer is dominated by curvature, and m = 0.4 shows higher cooling effects than m = 0.2 or 0.6, as expected, based on flat-plate results. Hydrodynamic measurements with a triple-hot-wire suggest the existence of two streamwise lanes. Lanes containing injection holes are highly affected by injection and show a definite streamwise evolution. Lanes which do not contain holes are not affected much by injection and show little change in the streamwise direction.

Furuhama, K.↗

Photovoltaic performance models - A report card

Models for the analysis of photovoltaic (PV) systems' designs, implementation policies, and economic performance, have proliferated while keeping pace with rapid changes in basic PV technology and extensive empirical data compiled for such systems' performance. Attention is presently given to the results of a comparative assessment of ten well documented and widely used models, which range in complexity from first-order approximations of PV system performance to in-depth, circuit-level characterizations. The comparisons were made on the basis of the performance of their subsystem, as well as system, elements. The models fall into three categories in light of their degree of aggregation into subsystems: (1) simplified models for first-order calculation of system performance, with easily met input requirements but limited capability to address more than a small variety of design considerations; (2) models simulating PV systems in greater detail, encompassing types primarily intended for either concentrator-incorporating or flat plate collector PV systems; and (3) models not specifically designed for PV system performance modeling, but applicable to aspects of electrical system design. Models ignoring subsystem failure or degradation are noted to exclude operating and maintenance characteristics as well.

Smith, J. H.↗

Film cooling on a convex wall: Heat transfer and hydrodynamic measurements for full and partial coverage

Turbine-blade cooling is an important issue for high-efficiency turbine engines, and discrete-hole injection is widely used as a cooling method. In the present study, detailed measurements were made of the heat transfer and hydrodynamics of a film-cooled flow on a convex wall, both for full and partial coverage. Two important parameters were altered: the blowing ratio, m, and the number of rows of injection holes. Three values of m were tested: m = 0.2, 0.4, and 0.6. In the blown region, m = 0.4 results in the lowest Stanton numbers of the three blowing ratios tested. This indicates that the value of m = 0.4 is near optimum on the convex wall from the point of view of cooling effect by injection. In the recovery region, Stanton numbers gradually approach the no injection values. Although the heat-transfer behavior during recovery from injection looks relatively complicated, the behavior of Stanton number can be explained in terms of two mechanisms: recovery from the thermal effect of injection and recovery from the turbulence augmentation. This interpretation of the data is supported by the hydrodynamic and temperture-profile measurements. For partial blowing cases, the data follow the full-coverage values inside the blown region. In the unblown region, both in the curved and in the flat plate, the effect of the number of blown rows is clearly seen. Hydrodynamic boundary-layer profiles were measured with the aid of a triple hot-water probe. Three mean-velocity components and six turbulence quantities were simultaneously measured, and inside the blown region strong three-dimensionality was observed.

Furuhama, K.↗

Development of an explicit multigrid algorithm for quasi-three-dimensional viscous flows in turbo-machinery

A rapid quasi three-dimensional analysis was developed for blade-to-blade flows in turbomachinery. The analysis solves the unsteady Euler or thin layer Navier-Stokes equations in a body-fitted coordinate system. It accounts for the effects of rotation, radius change, and stream-surface thickness. The Baldwin-Lomax eddy-viscosity model is used for turbulent flows. The equations which are solved by a two-stage Runge-Kutta scheme made efficient by use of vectorization, a variable time-step, and a flux-based multigrid scheme, are described. A stability analysis is presented for the two-stage scheme. Results for a flat-plate model problem show the applicability of the method to axial, radial, and rotating geometries. Results for a centrifugal impeller and a radial diffuser show that the quasi three-dimensional viscous analysis can be a practical design tool.

Chima, R. V.↗

Reliability and Engineering of Thin-Film Photovoltaic Modules. Research forum proceedings

A Research Forum on Reliability and Engineering of Thin Film Photovoltaic Modules, under sponsorship of the Jet Propulsion Laboratory's Flat Plate Solar Array (FSA) Project and the U.S. Department of Energy, was held in Washington, D.C., on March 20, 1985. Reliability attribute investigations of amorphous silicon cells, submodules, and modules were the subjects addressed by most of the Forum presentations. Included among the reliability research investigations reported were: Arrhenius-modeled accelerated stress tests on a Si cells, electrochemical corrosion, light induced effects and their potential effects on stability and reliability measurement methods, laser scribing considerations, and determination of degradation rates and mechanisms from both laboratory and outdoor exposure tests.

Ross, R. G., Jr.↗

Electrical safety requirements: Implications for the module designer

Commercial photovoltaic array installations, which include residential and intermediate applications, are subject to building and electrical codes and to product safety standards. The National Electrical Code (NEC) Article 690, titled Solar Photovoltaic Systems, contains provisions defining acceptable levels of system safety and emphasizes the system design and its installation. The Underwriters Laboratories, Inc. (UL), document titled: Proposed First Edition of the Standard for Flat Plate Photovoltaic Modules and Panels, UL-1703, identifies module and panel construction requirements that ensure product safety. Together these documents describe requirements intended to minimize hazards such as shock and fire. Although initial focus of these requirements is on single crystal silicon modules, they are generic in nature, and are equally applicable to high voltage ( 30 Vdc), multikilowatt, thin film systems. A major safety concern is insulation breakdown within the module or array wiring system, or discontinuities within the electrical conductors. These failures can result in ground faults, in circuit arcs, or exposure to hazardous electrical parts. Safeguards are discussed.

Sugimura, R. S.↗

Encapsulant selection and durability testing experience

The Flat Plate Solar Array Project (FSA) has established technically challenging cost and service life goals for photovoltaic modules. These goals are a cost of $70 sq m and an expected 30 years of service life in an outdoor weathering environment. out of the cost goal, $14 sq m is allocated for encapsulation materials, which includes the cost of a structural panel. At FSA's inception in 1975, the cumulative cost of encapsulation materials in popular use, such as room temperature vulcanized (RTV) silicones, aluminum panels, etc., greatly exceeded $14/sq m. Accordingly, it became necessary to identify and/or develop new materials and new material technologies to achieve the goals. Many of these new materials are low cost polymers that satisfy module engineering and encapsulation processing requirements but unfortunately are not intrinsically weather stable. This necessitates identifying lifetime and/or weathering deficiencies inherent in these low cost materials and developing specific approaches to enhancing weather stability.

Cuddihy, E. F.↗

Mechanical testing of large thallium doped sodium iodide single crystals

The findings of mechanical tests performed on five thallium-doped sodium iodide NaI(Tl) crystals are presented. These crystals are all in the shape of circular flat plates, 20.0 in. in diameter an d0.5 in. thick. The test setup, testing procedure, and the test data are presented. Large crystals exhibit a high degree of material plasticity, as well as a much higher strength than previously anticipated, on the order of 500 psi. Also revealed from the testing is the fact that crystal with a large number of grain boundaries developed less plasticity, and therefore less permanent deformation, than those with fewer grain boundaries.

Lee, H. M.↗

Development of computational fluid dynamics at NASA Ames Research Center

Ames Research Center has the lead role among NASA centers to conduct research in computational fluid dynamics. The past, the present, and the future prospects in this field are reviewed. Past accomplishments include pioneering computer simulations of fluid dynamics problems that have made computers valuable in complementing wind tunnels for aerodynamic research. The present facilities include the most powerful computers built in the United States. Three examples of viscous flow simulations are presented: an afterbody with an exhaust plume, a blunt fin mounted on a flat plate, and the space shuttle. The future prospects include implementation of the Numerical Aerodynamic Simulation Processing System that will provide the capability for solving the viscous flow field around an aircraft in a matter of minutes.

Inouye, M.↗

Low Reynold's number boundary layers in a disturbed environment

Studies of flat plate boundary layer development were made in a low speed wind tunnel at turbulence levels from 2%to 7%. Only transitional and turbulent flows were observed in the range 280 Re sub theta 700. The mean turbulent velocity profiles display law-of-the-wall behavior but have negligible wake component. The u' disturbance profiles compare well with those of other experiments, the peak value of u'/u sub tau being about 2.5. The effect of free-stream turbulence level on turbulent skin friction can be nicely correlated with those of other investigations on a plot of u sub e/u sub tau versus Re sub theta. A discussion on the u' spectra for the transitional boundary-layers is presented.

Paik, D. K.↗

Overview of SERI's high efficiency solar cell research

The bulk of the research efforts supported by the Solar Energy Research Institute (SERI) High Efficiency Concepts area has been directed towards establishing the feasibility of achieving very high efficiencies, 30% for concentrator and more than 20% for thin film flat plate, in solar cell designs which could possibly be produced competitively. The research has accomplished a great deal during the past two years. Even though the desired performance levels have not yet been demonstrated, based on the recent progress, a greater portion of the terrestrial photovoltaics community believes that these efficiencies are attainable. The program will now allocate a larger portion of resources to low cost, large area deposition technology. The program is currently shifting greater emphasis on to the study of crystal growth in order to provide the understanding and tools needed to design a large area process.

Benner, J. P.↗