Editorial: Resolving atmospheric flow in complex environments: recent experiments in terrain and forest canopies

The characterization of atmospheric flows in complex environments, which may include steep terrain slopes and heterogeneous vegetation and/or forest cover, is a long-standing challenge in boundary-layer meteorology. Atmospheric observations are complicated by the presence of transient, terrain-induced flow features, forest-canopy-atmosphere interactions, and atmospheric stability effects, not to mention the logistical hurdles involved with instrument deployment, data analysis, and quality control. Furthermore, challenges in atmospheric modeling arise due to numerical errors associated with complex terrain flows, as well as reliance on simplified parameterizations for unresolved processes such as turbulent mixing and land-surface or forest-canopy-atmosphere interactions. These modeling challenges are exacerbated in the so-called “gray zone,” wherein features of interest have length scales that are similar to the model grid spacing, or when the principal flow layer is smaller than the grid spacing (e.g., slope flows).

54 ENVIRONMENTAL SCIENCES↗

Multi-Tiered Estimation for Correlation Spectroscopy in 3D (MTECS3D) v0.1

This innovative software estimates rotational diffusion coefficients of particles from X-ray photon correlation spectroscopy (XPCS) data of monodispersed particle systems. It is the first method capable of extracting rotational diffusion information from three-dimensional particle systems using XPCS. Using the angular-temporal cross-correlation of the XPCS images, this software is able to estimate the rotational diffusion coefficients with only a few percent relative errors while requiring minimal prior knowledge of particle structures. This software enhances XPCS analysis capabilities, allowing researchers to study translational and rotational Brownian dynamics of particles in suspension across various temporal and spatial scales.

Hu, Zixi↗

Linear Collider Test Facility: Twiss Parameter Analysis at the IP/Post-IP Location of the ATF2 Beam Line

At the first stage of the ATF2 beam tuning, vertical beam size is usually bigger than 3 {micro}m at the IP. Beam waist measurements using wire scanners and a laser wire are usually performed to check the initial matching of the beam through to the IP. These measurements are described in this paper for the optics currently used ({beta}{sub x} = 4cm and {beta}{sub y} = 1mm). Software implemented in the control room to automate these measurements with integrated analysis is also described. Measurements showed that {beta} functions and emittances were within errors of measurements when no rematching and coupling corrections were done. However, it was observed that the waist in the horizontal (X) and vertical (Y) plane was abnormally shifted and simulations were performed to try to understand these shifts. They also showed that multiknobs are needed in the current optics to correct simultaneously {alpha}{sub x}, {alpha}{sub y} and the horizontal dispersion (D{sub x}). Such multiknobs were found and their linearity and orthogonality were successfully checked using MAD optics code. The software for these multiknobs was implemented in the control room and waist scan measurements using the {alpha}{sub y} knob were successfully performed.

43 PARTICLE ACCELERATORS↗

Neutral B-Meson Mixing Parameters in and beyond the SM with 2+1 Flavor Lattice QCD

We report on the status of our calculation of the hadronic matrix elements for neutral $B$-meson mixing with asqtad sea and valence light quarks and using the Wilson clover action with the Fermilab interpretation for the $b$ quark. We calculate the matrix elements of all five local operators that contribute to neutral $B$-meson mixing both in and beyond the Standard Model. We use MILC ensembles with $N_f=2+1$ dynamical flavors at four different lattice spacings in the range $a \approx 0.045$--$0.12$~fm, and with light sea-quark masses as low as 0.05 times the physical strange quark mass. We perform a combined chiral-continuum extrapolation including the so-called wrong-spin contributions in simultaneous fits to the matrix elements of the five operators. We present a complete systematic error budget and conclude with an outlook for obtaining final results from this analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Electronic Damping of Microphonics in Superconducting Cavities

In low current applications superconducting cavities have a high susceptibility to microphonics induced by external vibrations and pressure fluctuations. Due to the narrow bandwidth of the cavities, the amount of rf power required to stabilize the phase and amplitude of the cavity field is dictated by the amount of microphonics that need to be compensated. Electronic damping of microphonics is investigated as a method to reduce the level of microphonics and of the amount of rf power required. The current work presents a detailed analysis of electronic damping and of the residual cavity field amplitude and phase errors due to the fluctuations of cavity frequency and beam current.

Delayen, Jean↗

THE BOSS Ly{alpha} FOREST SAMPLE FROM SDSS DATA RELEASE 9

We present the BOSS Lyman-{alpha} (Ly{alpha}) Forest Sample from SDSS Data Release 9, comprising 54,468 quasar spectra with z{sub qso} > 2.15 suitable for Ly{alpha} forest analysis. This data set probes the intergalactic medium with absorption redshifts 2.0 < z{sub {alpha}} < 5.7 over an area of 3275 deg{sup 2}, and encompasses an approximate comoving volume of 20 h {sup -3} Gpc{sup 3}. With each spectrum, we have included several products designed to aid in Ly{alpha} forest analysis: improved sky masks that flag pixels where data may be unreliable, corrections for known biases in the pipeline estimated noise, masks for the cores of damped Ly{alpha} systems and corrections for their wings, and estimates of the unabsorbed continua so that the observed flux can be converted to a fractional transmission. The continua are derived using a principal component fit to the quasar spectrum redward of rest-frame Ly{alpha} ({lambda} > 1216 A), extrapolated into the forest region and normalized by a linear function to fit the expected evolution of the Ly{alpha} forest mean flux. The estimated continuum errors are {approx}< 5% rms. We also discuss possible systematics arising from uncertain spectrophotometry and artifacts in the flux calibration; global corrections for the latter are provided. Our sample provides a convenient starting point for users to analyze clustering in BOSS Ly{alpha} forest data, and it provides a fiducial data set that can be used to compare results from different analyses of baryon acoustic oscillations in the Ly{alpha} forest. The full data set is available from the SDSS-III DR9 Web site.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-275: A Correlation Study On 3D Fluence-Based QA and 2D Dose Measurement-Based QA

Purpose: The aim of this paper was to demonstrate the feasibility and creditability of computing and verifying 3D fluencies to assure IMRT and VMAT treatment deliveries, by correlating the passing rates of the 3D fluence-based QA (P(ά)) to the passing rates of 2D dose measurementbased QA (P(Dm)). Methods: 3D volumetric primary fluencies are calculated by forward-projecting the beam apertures and modulated by beam MU values at all gantry angles. We first introduce simulated machine parameter errors (MU, MLC positions, jaw, gantry and collimator) to the plan. Using passing rates of voxel intensity differences (P(Ir)) and 3D gamma analysis (P(γ)), calculated 3D fluencies, calculated 3D delivered dose, and measured 2D planar dose in phantom from the original plan are then compared with those from corresponding plans with errors, respectively. The correlations of these three groups of resultant passing rates, i.e. 3D fluence-based QA (P(ά,Ir) and P(ά,γ)), calculated 3D dose (P(Dc,Ir) and P(Dc,γ)), and 2D dose measurement-based QA (P(Dm,Ir) and P(Dm,γ)), will be investigated. Results: 20 treatment plans with 5 different types of errors were tested. Spearman’s correlations were found between P(ά,Ir) and P(Dc,Ir), and also between P(ά,γ) and P(Dc,γ), with averaged p-value 0.037, 0.065, and averaged correlation coefficient ρ-value 0.942, 0.871 respectively. Using Matrixx QA for IMRT plans, Spearman’s correlations were also obtained between P(ά,Ir) and P(Dm,Ir) and also between P(ά,γ) and P(Dm,γ), with p-value being 0.048, 0.071 and ρ-value being 0.897, 0.779 respectively. Conclusion: The demonstrated correlations improve the creditability of using 3D fluence-based QA for assuring treatment deliveries for IMRT/VMAT plans. Together with advantages of high detection sensitivity and better visualization of machine parameter errors, this study further demonstrates the accuracy and feasibility of 3D fluence based-QA in pre-treatment QA and daily QA. Research reported in this study is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

TopoSZ: Preserving Topology in Error-Bounded Lossy Compression

Existing error-bounded lossy compression techniques control the pointwise error during compression to guarantee the integrity of the decompressed data. However, they typically do not explicitly preserve the topological features in data. When performing post hoc analysis with decompressed data using topological methods, preserving topology in the compression process to obtain topologically consistent and correct scientific insights is desirable. In this paper, we introduce TopoSZ, an error-bounded lossy compression method that preserves the topological features in 2D and 3D scalar fields. Specifically, we aim to preserve the types and locations of local extrema as well as the level set relations among critical points captured by contour trees in the decompressed data. The main idea is to derive topological constraints from contour-tree-induced segmentation from the data domain, and incorporate such constraints with a customized error-controlled quantization strategy from the SZ compressor (version 1.4). In conclusion, our method allows users to control the pointwise error and the loss of topological features during the compression process with a global error bound and a persistence threshold.

97 MATHEMATICS AND COMPUTING↗

Evaluation and comparison of benchmark QSAR models to predict a relevant REACH endpoint: The bioconcentration factor (BCF)

The bioconcentration factor (BCF) is an important bioaccumulation hazard assessment metric in many regulatory contexts. Its assessment is required by the REACH regulation (Registration, Evaluation, Authorization and Restriction of Chemicals) and by CLP (Classification, Labeling and Packaging). We challenged nine well-known and widely used BCF QSAR models against 851 compounds stored in an ad-hoc created database. The goodness of the regression analysis was assessed by considering the determination coefficient (R{sup 2}) and the Root Mean Square Error (RMSE); Cooper's statistics and Matthew's Correlation Coefficient (MCC) were calculated for all the thresholds relevant for regulatory purposes (i.e. 100 L/kg for Chemical Safety Assessment; 500 L/kg for Classification and Labeling; 2000 and 5000 L/kg for Persistent, Bioaccumulative and Toxic (PBT) and very Persistent, very Bioaccumulative (vPvB) assessment) to assess the classification, with particular attention to the models' ability to control the occurrence of false negatives. As a first step, statistical analysis was performed for the predictions of the entire dataset; R{sup 2}>0.70 was obtained using CORAL, T.E.S.T. and EPISuite Arnot–Gobas models. As classifiers, ACD and log P-based equations were the best in terms of sensitivity, ranging from 0.75 to 0.94. External compound predictions were carried out for the models that had their own training sets. CORAL model returned the best performance (R{sup 2}{sub ext}=0.59), followed by the EPISuite Meylan model (R{sup 2}{sub ext}=0.58). The latter gave also the highest sensitivity on external compounds with values from 0.55 to 0.85, depending on the thresholds. Statistics were also compiled for compounds falling into the models Applicability Domain (AD), giving better performances. In this respect, VEGA CAESAR was the best model in terms of regression (R{sup 2}=0.94) and classification (average sensitivity>0.80). This model also showed the best regression (R{sup 2}=0.85) and sensitivity (average>0.70) for new compounds in the AD but not present in the training set. However, no single optimal model exists and, thus, it would be wise a case-by-case assessment. Yet, integrating the wealth of information from multiple models remains the winner approach. - Highlights: • REACH encourages the use of in silico methods in the assessment of chemicals safety. • The performances of nine BCF models were evaluated on a benchmark database of 851 chemicals. • We compared the models on the basis of both regression and classification performance. • Statistics on chemicals out of the training set and/or within the applicability domain were compiled. • The results show that QSAR models are useful as weight-of-evidence in support to other methods.

54 ENVIRONMENTAL SCIENCES↗

Inferring morphology and strength of magnetic fields from proton radiographs

Proton radiography is an important diagnostic method for laser plasma experiments and is particularly important in the analysis of magnetized plasmas. The theory of radiographic image analysis has heretofore only permitted somewhat limited analysis of the radiographs of such plasmas. We furnish here a theory that remedies this deficiency. We show that to linear order in magnetic field gradients, proton radiographs are projection images of the MHD current along the proton trajectories. We demonstrate that in the linear regime (i.e., the small image contrast regime), the full structure of the projected perpendicular magnetic field can be reconstructed by solving a steady-state inhomogeneous 2-dimensional diffusion equation sourced by the radiograph fluence contrast data. Here, we explore the validity of the scheme with increasing image contrast, as well as limitations of the inversion method due to the Poisson noise, discretization errors, radiograph edge effects, and obstruction by laser target structures. We also provide a separate analysis that is suited to the inference of isotropic-homogeneous magnetic turbulence spectra. Finally, we discuss extension of these results to the nonlinear regime (i.e., the order unity image contrast regime).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-P-36: Evaluation of MLC Positioning Errors in Dynamic IMRT Treatments by Analyzing Dynalog Files

Purpose: To assess the accuracy of MLC positioning in Varian linear accelerator, in dynamic IMRT technique, from the analysis of dynalog files generated by the MLC controller. Methods: In Clinac accelerators (pre-TrueBeam technology), control system has an approximately 50ms delay (one control cycle time). Then, the system compares the measured position to the planned position corresponding to the next control cycle. As it has been confirmed by Varian technical support, this effect causes that measured positions appear in dynalogs one cycle out of phase with respect to the planned positions. Around 9000 dynalogs have been analyzed, coming from the three linear accelerators of our center (one Trilogy and two Clinac 21EX) equipped with a Millennium 120 MLC. In order to compare our results to recent publications, leaf positioning errors (RMS and 95th percentile) are calculated with and without delay effect. Dynalogs have been analyzed using a in-house Matlab software. Results: The RMS errors were 0.341, 0.339 and 0.348mm for each Linac; being the average error 0.343 mm. The 95th percentiles of the error were 0.617, 0.607 and 0.625; with an average of 0.617mm. A recent multi-institution study carried out by Kerns et al. found a mean leaf RMS error of 0.32mm and a 95th percentile error value of 0.64mm.Without delay effect, mean leaf RMS errors obtained were 0.040, 0.042 and 0.038mm for each treatment machine; being the average 0.040mm. The 95th percentile error values obtained were 0.057, 0.058 and 0.054 mm, with an average of 0.056mm. Conclusion: Results obtained for the mean leaf RMS error and the mean 95th percentile were consistent with the multi-institution study. Calculated error statistics with delay effect are significantly larger due to the speed proportional and systematic leaf offset. Consequently it is proposed to correct this effect in dynalogs analysis to determine the MLC performance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-221: Computational Evaluation of Proton Induced Gain in a Portable Faraday Cup

Purpose: The design of a new Portable Faraday Cup (PFC) used to calibrate proton accelerators was evaluated for energies between 50 and 220 MeV. Monte Carlo simulations performed in Geant4–10.0 were used to evaluate experimental results and reduce the relative detector error for this vacuum-less and low mass system, and invalidate current MCNP releases. Methods: The detector construction consisted of a copper conductor coated with an insulator and grounded with silver. Monte Carlo calculations in Geant4 were used to determine the net charge per proton input (gain) as a function of insulator thickness and beam energy. Kapton was chosen as the insulating material and was designed to capture backscattered electrons. Charge displacement from/into Kapton was assumed to follow a linear proportionality to the origin/terminus depth toward the outer ground layer. Kapton thicknesses ranged from 0 to 200 microns, proton energies were set to match empirical studies ranging from 70 to 250 MeV. Each setup was averaged over 1 million events using the FTFP-BERT 2.0 physics list. Results: With increasing proton energy, the gain of Cu+KA gradually converges to the limit of pure copper, with relative error between 1.52% and 0.72%. The Ag layer created a more diverging behavior, accelerating the flux of negative charge into the device and increasing relative error when compared to pure copper from 1.21% to 1.63%. Conclusion: Gain vs. beam energy signatures were acquired for each device. Further analysis reveals proportionality between insulator thickness and measured gain, albeit an inverse proportionality between beam energy and in-flux of electrons. Increased silver grounding layer thickness also decreases gain, though the relative error expands with beam energy, contrary to the Kapton layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-468: Efficient Scanning Data Analysis for TomoTherapy

Purpose: The standard TomoTherapy 2D scanning system requires manual analysis using spreadsheets or similar software. Manual analysis is time consuming and does not allow efficient use of the medical physicist or timely results that may indicate issues during the acquisition of data. The purpose of this study is to determine if an in-house solution can provide timely analysis of TomoTherapy scan data. Methods: A custom MATLAB program utilizing a streamlined graphical interface was developed to interpret the native scanning data acquired by the TomoTherapy Electrometer Measurement System (TEMS). The gold beam data provided by the manufacturer was used as a baseline for the acquired data. Two separate sets of scan data were used including longitudinal, transverse, and percent depth dose (PDD). The scan data were compared visually in an overlay and analytically for each beam width using the full width half max (FWHM) for longitudinal profiles and difference inside the field core for the transverse profiles as recommended by TG-148. A plot of the PDD percent error at each point along the curve was generated to show agreement. The time to analysis was measured on a laptop running an Intel i5 processor with 8GB of RAM. Results: The software program required on average less than 5 seconds to load and analyze the results. No conversion or reformatting of the data was required. This allowed real-time visualization of the comparison to the gold beam data as well as the parameters recommended by TG-148. The average percent difference was 0.3% for the longitudinal profiles and 0.1% for the transverse profiles. All PDD data was less than 1% different beyond dmax. Conclusion: We have developed a tool to analyze TomoTherapy scan data in real-time. This allows an efficient method to perform beam commissioning, annual QA, and adjust the beam parameters if necessary.

61 RADIATION PROTECTION AND DOSIMETRY↗

Review of the Nuclear Energy Agency (NEA) Ancillary Thermodynamic Database (TDB) Volume (DRAFT REV. 0)

The Nuclear Energy Agency (NEA) Ancillary data volume comprises thermodynamic data of mineral and aqueous species that, in addition to Auxiliary Data (as referred to in previous NEA thermodynamic data volumes), is necessary to calculations of chemical interactions relevant to radioactive waste management and nuclear energy. This SAND report is a review of the NEA Ancillary data critical reviews volume of thermodynamic data parameters. The review given in this report mainly involves data comparison with other thermodynamic data assessments, analysis of thermodynamic parameters, and examination of data sources. Only new and updated data parameters were considered in this review. Overall, no major inconsistencies or errors were found as allowed by the comparisons conducted in this review. Some remarks were noted, for example, on the consideration of relevant studies and/or comparisons on the analysis and retrieval of thermodynamic data parameters not cited in the respective sections.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation Analysis of Medium-Scale Methanol Pool Fire Simulated in SIERRA/Fuego [Slides]

Analysis of methanol pool fire conducted as part of validation study for SIERRA/Fuego. Results showed trends & errors consistent with related studies. Area validation metric provides way to quantify model form uncertainty. AVM shows that more work could be done to understand how model form uncertainty varies with mesh resolution. There is a possible atypical use of MAVM on time-series data. AVM shows mismatch between predicted flame height and experimental value less sensitive to variations in mixture fraction than temperature. Mismatch about experimental value also more symmetric for mixture fraction. Our analysis showed that mixture fraction is preferable for this application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Template Engine Applied to Rapid Modeling

Modeling complex problems can require a significant effort, be subject to human error, and contain repeated patterns of input. SCALE 6.2 and the Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS) have attempted to mitigate these problems with the use of a template engine and template syntax. The template syntax allows redundant input to be consolidated into its simplest pattern and parameterized on the parts that change, reducing effort and likelihood of errors and encapsulating user experience into a reusable model component. This paper presents a summary of rapid modeling benefits and techniques that are facilitated when using templates. Specifically, this paper will discuss how these are applied in conducting as-loaded spent nuclear fuel canister criticality calculations using UNF-ST&DARDS and model perturbation and sampling using.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimisation of the Kaplan hydropower system via PID 2 and digital twin

Here, this paper proposes a proportional–integral-double–derivative (PID 2 ) optimisation method for the Kaplan hydropower system by building a digital twin. The study first uses one multilayer perceptron (MLP) to model the hydroturbine dynamic and then adopts three connected MLPs to model the generator dynamic, both in an open-loop fashion. Inspired by stochastic distribution control (SDC) theory, we regard the training of the turbine's neural network model as a process control problem, and we propose minimising entropy loss to update the network parameters. The next step is to build the digital twin by connecting the neural network models with a PID 2 controller and a lead-lag exciter and run the whole model in a closed-loop fashion. After that, a binary search approach is applied to optimise the PID 2 parameters based on the obtained digital twin model. The simulation results show that the proposed method can reduce the mean square tracking error by more than 90%. Furthermore, the method is extended to jointly optimise the PID 2 controller and excitation system gains through multiobjective optimisation, leveraging Pareto frontier analysis to balance active power and voltage tracking performance. Simulation results confirm the effectiveness of the proposed method, achieving a 83.46% reduction in relative mean square error of active power, a 47.13% reduction in terminal voltage tracking error, and an 82.78% improvement in the overall scalarized objective.

Hydropower system↗

Development of Streamlined Nuclear Safety Analysis Tool for Spent Nuclear Fuel Applications

To understand the changing nuclear and mechanical characteristics of spent nuclear fuel (SNF) or used nuclear fuel (UNF) and the different storage, transportation, and disposal systems at various stages within the waste management system, different types of analyses are required. These analyses require the use of assorted tools and numerous types of data. Using the appropriate modeling and simulation (M&S) parameters and selecting from the diversity of analytic tools to conduct SNF analyses can be a tedious, error-prone, and time-consuming undertaking for analysts and reviewers alike. A new, integrated data and analysis system was designed to simplify and automate performance of accurate, efficient evaluations for characterizing the input to the overall U.S. nuclear waste management system—the UNF-Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). A relational database has been assembled to provide a standard means by which UNF-ST&DARDS can succinctly store and retrieve M&S parameters for specific SNF analysis. A library of various analysis model templates is used to communicate M&S parameters for the most appropriate M&S application. A process manager facilitates performance of actual as-loaded, assembly-specific, and cask-specific evaluations. Interactive visualization capabilities facilitate data analysis and results interpretation. To date, UNF-ST&DARDS has completed (1) explicit depletion and decay analysis of every fuel assembly (~245 000) discharged from commercial U.S. reactors through June 2013, with 13 cooling time steps (results include isotopic compositions for 142 isotopes, and radiation and thermal source terms); (2) SNF radiation dose rate evaluations at 1 m for all the fuel assemblies discharged through June 2013; and (3) criticality, shielding, thermal, and containment analyses of hundreds of loaded casks. In conclusion, UNF-ST&DARDS also provides various automated report generation capabilities with dynamic figure and table update capabilities based on changes to the Unified Database.