Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Eclipse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Development of a novel ArcCHECK{sup Trade-Mark-Sign} insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities

Purpose: To design a versatile, nonhomogeneous insert for the dose verification phantom ArcCHECK{sup Trade-Mark-Sign} (Sun Nuclear Corp., FL) and to demonstrate its usefulness for the verification of dose distributions in inhomogeneous media. As an example, we demonstrate it can be used clinically for routine quality assurance of two volumetric modulated arc therapy (VMAT) systems for lung stereotactic body radiation therapy (SBRT): SmartArc{sup Registered-Sign} (Pinnacle{sup 3}, Philips Radiation Oncology Systems, Fitchburg, WI) and RapidArc{sup Registered-Sign} (Eclipse{sup Trade-Mark-Sign }, Varian Medical Systems, Palo Alto, CA). Methods: The cylindrical detector array ArcCHECK{sup Trade-Mark-Sign} has a retractable homogeneous acrylic insert. In this work, we designed and manufactured a customized heterogeneous insert with densities that simulate soft tissue, lung, bone, and air. The insert offers several possible heterogeneity configurations and multiple locations for point dose measurements. SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans for lung SBRT were generated and copied to ArcCHECK{sup Trade-Mark-Sign} for each inhomogeneity configuration. Dose delivery was done on a Varian 2100 ix linac. The evaluation of dose distributions was based on gamma analysis of the diode measurements and point doses measurements at different positions near the inhomogeneities. Results: The insert was successfully manufactured and tested with different measurements of VMAT plans. Dose distributions measured with the homogeneous insert showed gamma passing rates similar to our clinical results ({approx}99%) for both treatment-planning systems. Using nonhomogeneous inserts decreased the passing rates by up to 3.6% in the examples studied. Overall, SmartArc{sup Registered-Sign} plans showed better gamma passing rates for nonhomogeneous measurements. The discrepancy between calculated and measured point doses was increased up to 6.5% for the nonhomogeneous insert depending on the inhomogeneity configuration and measurement location. SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans had similar plan quality but RapidArc{sup Registered-Sign} plans had significantly higher monitor units (up to 70%). Conclusions: A versatile, nonhomogeneous insert was developed for ArcCHECK{sup Trade-Mark-Sign} for an easy and quick evaluation of dose calculations with nonhomogeneous media and for comparison of different treatment planning systems. The device was tested for SmartArc{sup Registered-Sign} and RapidArc{sup Registered-Sign} plans for lung SBRT, showing the uncertainties of dose calculations with inhomogeneities. The new insert combines the convenience of the ArcCHECK{sup Trade-Mark-Sign} and the possibility of assessing dose distributions in inhomogeneous media.

60 APPLIED LIFE SCIENCES↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

Small field segments surrounded by large areas only shielded by a multileaf collimator: Comparison of experiments and dose calculation

Purpose: Complex radiotherapy fields delivered using a tertiary multileaf collimator (MLC) often feature small open segments surrounded by large areas of the beam only shielded by the MLC. The aim of this study was to test the ability of two modern dose calculation algorithms to accurately calculate the dose in these fields which would be common, for example, in volumetric modulated arc treatment (VMAT) and study the impact of variations in dosimetric leaf gap (DLG), focal spot size, and MLC transmission in the beam models. Methods: Nine test fields with small fields (0.6-3 cm side length) surrounded by large MLC shielded areas (secondary collimator 12 Multiplication-Sign 12 cm{sup 2}) were created using a 6 MV beam from a Varian Clinac iX linear accelerator with 120 leaf MLC. Measurements of output factors and profiles were performed using a diamond detector (PTW) and compared to two dose calculations algorithms anisotropic analytical algorithm [(AAA) and Acuros XB] implemented on a commercial radiotherapy treatment planning system (Varian Eclipse 10). Results: Both calculation algorithms predicted output factors within 1% for field sizes larger than 1 Multiplication-Sign 1 cm{sup 2}. For smaller fields AAA tended to underestimate the dose. Profiles were predicted well for all fields except for problems of Acuros XB to model the secondary penumbra between MLC shielded fields and the secondary collimator. A focal spot size of 1 mm or less, DLG 1.4 mm and MLC transmission of 1.4% provided a generally good model for our experimental setup. Conclusions: AAA and Acuros XB were found to predict the dose under small MLC defined field segments well. While DLG and focal spot affect mostly the penumbra, the choice of correct MLC transmission will be essential to model treatments such as VMAT accurately.

60 APPLIED LIFE SCIENCES↗

Commissioning of intensity modulated neutron radiotherapy (IMNRT)

Purpose: Intensity modulated neutron radiotherapy (IMNRT) has been developed using inhouse treatment planning and delivery systems at the Karmanos Cancer Center/Wayne State University Fast Neutron Therapy facility. The process of commissioning IMNRT for clinical use is presented here. Results of commissioning tests are provided including validation measurements using representative patient plans as well as those from the TG-119 test suite. Methods: IMNRT plans were created using the Varian Eclipse optimization algorithm and an inhouse planning system for calculation of neutron dose distributions. Tissue equivalent ionization chambers and an ionization chamber array were used for point dose and planar dose distribution comparisons with calculated values. Validation plans were delivered to water and virtual water phantoms using TG-119 measurement points and evaluation techniques. Photon and neutron doses were evaluated both inside and outside the target volume for a typical IMNRT plan to determine effects of intensity modulation on the photon dose component. Monitor unit linearity and effects of beam current and gantry angle on output were investigated, and an independent validation of neutron dosimetry was obtained. Results: While IMNRT plan quality is superior to conventional fast neutron therapy plans for clinical sites such as prostate and head and neck, it is inferior to photon IMRT for most TG-119 planning goals, particularly for complex cases. This results significantly from current limitations on the number of segments. Measured and calculated doses for 11 representative plans (six prostate/five head and neck) agreed to within -0.8 {+-} 1.4% and 5.0 {+-} 6.0% within and outside the target, respectively. Nearly all (22/24) ion chamber point measurements in the two phantom arrangements were within the respective confidence intervals for the quantity [(measured-planned)/prescription dose] derived in TG-119. Mean differences for all measurements were 0.5% (max = 7.0%) and 1.4% (max = 4.1%) in water and virtual water, respectively. The mean gamma pass rate for all cases was 92.8% (min = 88.6%). These pass rates are lower than typically achieved with photon IMRT, warranting development of a planar dosimetry system designed specifically for IMNRT and/or the improvement of neutron beam modeling in the penumbral region. The fractional photon dose component did not change significantly in a typical IMNRT plan versus a conventional fast neutron therapy plan, and IMNRT delivery is not expected to significantly alter the RBE. All other commissioning results were considered satisfactory for clinical implementation of IMNRT, including the external neutron dose validation, which agreed with the predicted neutron dose to within 1%. Conclusions: IMNRT has been successfully commissioned for clinical use. While current plan quality is inferior to photon IMRT, it is superior to conventional fast neutron therapy. Ion chamber validation results for IMNRT commissioning are also comparable to those typically achieved with photon IMRT. Gamma pass rates for planar dose distributions are lower than typically observed for photon IMRT but may be improved with improved planar dosimetry equipment and beam modeling techniques. In the meantime, patient-specific quality assurance measurements should rely more heavily on point dose measurements with tissue equivalent ionization chambers. No significant technical impediments are anticipated in the clinical implementation of IMNRT as described here.

60 APPLIED LIFE SCIENCES↗

Evaluation of an analytic linear Boltzmann transport equation solver for high-density inhomogeneities

Purpose: Acuros external beam (Acuros XB) is a novel dose calculation algorithm implemented through the ECLIPSE treatment planning system. The algorithm finds a deterministic solution to the linear Boltzmann transport equation, the same equation commonly solved stochastically by Monte Carlo methods. This work is an evaluation of Acuros XB, by comparison with Monte Carlo, for dose calculation applications involving high-density materials. Existing non-Monte Carlo clinical dose calculation algorithms, such as the analytic anisotropic algorithm (AAA), do not accurately model dose perturbations due to increased electron scatter within high-density volumes. Methods: Acuros XB, AAA, and EGSnrc based Monte Carlo are used to calculate dose distributions from 18 MV and 6 MV photon beams delivered to a cubic water phantom containing a rectangular high density (4.0-8.0 g/cm{sup 3}) volume at its center. The algorithms are also used to recalculate a clinical prostate treatment plan involving a unilateral hip prosthesis, originally evaluated using AAA. These results are compared graphically and numerically using gamma-index analysis. Radio-chromic film measurements are presented to augment Monte Carlo and Acuros XB dose perturbation data. Results: Using a 2% and 1 mm gamma-analysis, between 91.3% and 96.8% of Acuros XB dose voxels containing greater than 50% the normalized dose were in agreement with Monte Carlo data for virtual phantoms involving 18 MV and 6 MV photons, stainless steel and titanium alloy implants and for on-axis and oblique field delivery. A similar gamma-analysis of AAA against Monte Carlo data showed between 80.8% and 87.3% agreement. Comparing Acuros XB and AAA evaluations of a clinical prostate patient plan involving a unilateral hip prosthesis, Acuros XB showed good overall agreement with Monte Carlo while AAA underestimated dose on the upstream medial surface of the prosthesis due to electron scatter from the high-density material. Film measurements support the dose perturbations demonstrated by Monte Carlo and Acuros XB data. Conclusions: Acuros XB is shown to perform as well as Monte Carlo methods and better than existing clinical algorithms for dose calculations involving high-density volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Projection imaging of photon beams by the Cerenkov effect

Purpose: A novel technique for beam profiling of megavoltage photon beams was investigated for the first time by capturing images of the induced Cerenkov emission in water, as a potential surrogate for the imparted dose in irradiated media. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire 2D projection images of Cerenkov emission from a 4 Multiplication-Sign 4 cm{sup 2} 6 MV linear accelerator (LINAC) x-ray photon beam operating at a dose rate of 400 MU/min incident on a water tank with transparent walls. The ICCD acquisition was gated to the LINAC sync pulse to reduce background light artifacts, and the measurement quality was investigated by evaluating the signal to noise ratio and measurement repeatability as a function of delivered dose. Monte Carlo simulations were used to derive a calibration factor for differences between the optical images and deposited dose arising from the anisotropic angular dependence of Cerenkov emission. Finally, Cerenkov-based beam profiles were compared to a percent depth dose (PDD) and lateral dose profile at a depth of d{sub max} from a reference dose distribution generated from the clinical Varian ECLIPSE treatment planning system (TPS). Results: The signal to noise ratio was found to be 20 at a delivered dose of 66.6 cGy, and proportional to the square root of the delivered dose as expected from Poisson photon counting statistics. A 2.1% mean standard deviation and 5.6% maximum variation in successive measurements were observed, and the Monte Carlo derived calibration factor resulted in Cerenkov emission images which were directly correlated to deposited dose, with some spatial issues. The dose difference between the TPS and PDD predicted by Cerenkov measurements was within 20% in the buildup region with a distance to agreement (DTA) of 1.5-2 mm and {+-}3% at depths beyond d{sub max}. In the lateral profile, the dose difference at the beam penumbra was within {+-}13% with a DTA of 0-2 mm, {+-}5% in the central beam region, and 2%-3% in the beam umbra. Conclusions: The results from this initial study demonstrate the first documented use of Cerenkov emission imaging to profile x-ray photon LINAC beams in water. The proposed modality has several potential advantages over alternative methods, and upon future refinement may prove to be a robust and novel dosimetry method.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac

Purpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 Multiplication-Sign 1 to 40 Multiplication-Sign 40 cm{sup 2}. Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. Results: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 Multiplication-Sign 1 cm{sup 2}. Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 Multiplication-Sign 1 cm{sup 2} field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. Conclusions: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.

60 APPLIED LIFE SCIENCES↗

Development and clinical evaluation of automatic fiducial detection for tumor tracking in cine megavoltage images during volumetric modulated arc therapy

Purpose: Real-time tracking of implanted fiducials in cine megavoltage (MV) imaging during volumetric modulated arc therapy (VMAT) delivery is complicated due to the inherent low contrast of MV images and potential blockage of dynamic leaves configurations. The purpose of this work is to develop a clinically practical autodetection algorithm for motion management during VMAT. Methods: The expected field-specific segments and the planned fiducial position from the Eclipse (Varian Medical Systems, Palo Alto, CA) treatment planning system were projected onto the MV images. The fiducials were enhanced by applying a Laplacian of Gaussian filter in the spatial domain for each image, with a blob-shaped object as the impulse response. The search of implanted fiducials was then performed on a region of interest centered on the projection of the fiducial when it was within an open field including the case when it was close to the field edge or partially occluded by the leaves. A universal template formula was proposed for template matching and normalized cross correlation was employed for its simplicity and computational efficiency. The search region for every image was adaptively updated through a prediction model that employed the 3D position of the fiducial estimated from the localized positions in previous images. This prediction model allowed the actual fiducial position to be tracked dynamically and was used to initialize the search region. The artifacts caused by electronic interference during the acquisition were effectively removed. A score map was computed by combining both morphological information and image intensity. The pixel location with the highest score was selected as the detected fiducial position. The sets of cine MV images taken during treatment were analyzed with in-house developed software written in MATLAB (The Mathworks, Inc., Natick, MA). Five prostate patients were analyzed to assess the algorithm performance by measuring their positioning accuracy during treatment. Results: The algorithm was able to accurately localize the fiducial position on MV images with success rates of more than 90% per case. The percentage of images in which each fiducial was localized in the studied cases varied between 23% and 65%, with at least one fiducial having been localized between 40% and 95% of the images. This depended mainly on the modulation of the plan and fiducial blockage. The prostate movement in the presented cases varied between 0.8 and 3.5 mm (mean values). The maximum displacement detected among all patients was of 5.7 mm. Conclusions: An algorithm for automatic detection of fiducial markers in cine MV images has been developed and tested with five clinical cases. Despite the challenges posed by complex beam aperture shapes, fiducial localization close to the field edge, partial occlusion of fiducials, fast leaf and gantry movement, and inherently low MV image quality, good localization results were achieved in patient images. This work provides a technique for enabling real-time accurate fiducial detection and tumor tracking during VMAT treatments without the use of extra imaging dose.

60 APPLIED LIFE SCIENCES↗

Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer

Purpose: The novel deterministic radiation transport algorithm, Acuros XB (AXB), has shown great potential for accurate heterogeneous dose calculation. However, the clinical impact between AXB and other currently used algorithms still needs to be elucidated for translation between these algorithms. The purpose of this study was to investigate the impact of AXB for heterogeneous dose calculation in lung cancer for intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Methods: The thorax phantom from the Radiological Physics Center (RPC) was used for this study. IMRT and VMAT plans were created for the phantom in the Eclipse 11.0 treatment planning system. Each plan was delivered to the phantom three times using a Varian Clinac iX linear accelerator to ensure reproducibility. Thermoluminescent dosimeters (TLDs) and Gafchromic EBT2 film were placed inside the phantom to measure delivered doses. The measurements were compared with dose calculations from AXB 11.0.21 and the anisotropic analytical algorithm (AAA) 11.0.21. Two dose reporting modes of AXB, dose-to-medium in medium (D{sub m,m}) and dose-to-water in medium (D{sub w,m}), were studied. Point doses, dose profiles, and gamma analysis were used to quantify the agreement between measurements and calculations from both AXB and AAA. The computation times for AAA and AXB were also evaluated. Results: For the RPC lung phantom, AAA and AXB dose predictions were found in good agreement to TLD and film measurements for both IMRT and VMAT plans. TLD dose predictions were within 0.4%-4.4% to AXB doses (both D{sub m,m} and D{sub w,m}); and within 2.5%-6.4% to AAA doses, respectively. For the film comparisons, the gamma indexes ({+-}3%/3 mm criteria) were 94%, 97%, and 98% for AAA, AXB{sub Dm,m}, and AXB{sub Dw,m}, respectively. The differences between AXB and AAA in dose-volume histogram mean doses were within 2% in the planning target volume, lung, heart, and within 5% in the spinal cord. However, differences up to 8% between AXB and AAA were found at lung/soft tissue interface regions for individual IMRT fields. AAA was found to be 5-6 times faster than AXB for IMRT, while AXB was 4-5 times faster than AAA for VMAT plan. Conclusions: AXB is satisfactorily accurate for the dose calculation in lung cancer for both IMRT and VMAT plans. The differences between AXB and AAA are generally small except in heterogeneous interface regions. AXB D{sub w,m} and D{sub m,m} calculations are similar inside the soft tissue and lung regions. AXB can benefit lung VMAT plans by both improving accuracy and reducing computation time.

60 APPLIED LIFE SCIENCES↗

Changes realized from extended bit-depth and metal artifact reduction in CT

Purpose: High-Z material in computed tomography (CT) yields metal artifacts that degrade image quality and may cause substantial errors in dose calculation. This study couples a metal artifact reduction (MAR) algorithm with enhanced 16-bit depth (vs standard 12-bit) to quantify potential gains in image quality and dosimetry. Methods: Extended CT to electron density (CT-ED) curves were derived from a tissue characterization phantom with titanium and stainless steel inserts scanned at 90-140 kVp for 12- and 16-bit reconstructions. MAR was applied to sinogram data (Brilliance BigBore CT scanner, Philips Healthcare, v.3.5). Monte Carlo simulation (MC-SIM) was performed on a simulated double hip prostheses case (Cerrobend rods embedded in a pelvic phantom) using BEAMnrc/Dosxyz (400 000 0000 histories, 6X, 10 Multiplication-Sign 10 cm{sup 2} beam traversing Cerrobend rod). A phantom study was also conducted using a stainless steel rod embedded in solid water, and dosimetric verification was performed with Gafchromic film analysis (absolute difference and gamma analysis, 2% dose and 2 mm distance to agreement) for plans calculated with Anisotropic Analytic Algorithm (AAA, Eclipse v11.0) to elucidate changes between 12- and 16-bit data. Three patients (bony metastases to the femur and humerus, and a prostate cancer case) with metal implants were reconstructed using both bit depths, with dose calculated using AAA and derived CT-ED curves. Planar dose distributions were assessed via matrix analyses and using gamma criteria of 2%/2 mm. Results: For 12-bit images, CT numbers for titanium and stainless steel saturated at 3071 Hounsfield units (HU), whereas for 16-bit depth, mean CT numbers were much larger (e.g., titanium and stainless steel yielded HU of 8066.5 {+-} 56.6 and 13 588.5 {+-} 198.8 for 16-bit uncorrected scans at 120 kVp, respectively). MC-SIM was well-matched between 12- and 16-bit images except downstream of the Cerrobend rod, where 16-bit dose was {approx}6.4% greater than 12-bit. Absolute film dosimetry in a region downstream of a stainless steel rod revealed that 16-bit calculated dose, with and without MAR, agreed more closely with film results (1%-2% less than film) as compared to 12-bit reconstructions (5.6%-6.5% less than film measurements). Gamma analysis revealed that 16-bit dose calculations were better matched to film results than 12-bit ({approx}10% higher pass rates for 16-bit). Similar results were observed in two patient cases; the largest discrepancy was observed for a femur case where 12-bit doses, both with and without MAR correction, were 6-7 Gy lower ({approx}17%-20% of the prescription dose) as compared to 16-bit dose calculations. However, when beams are not directly traversing metal, such as a prostate cancer case with bilateral hip prostheses; the impact of 16-bit reconstruction was diminished. Conclusions: These results suggest that it may be desirable to implement 16-bit MAR-corrected images for treatment planning purposes, which can provide a more accurate dosimetric approach coupled with improved visualization by suppression of CT artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cobalt-60 tomotherapy: Clinical treatment planning and phantom dose delivery studies

Purpose: Investigations have shown that a Cobalt-60 (Co-60) radioactive source has the potential to play a role in intensity modulated radiation therapy (IMRT). In this paper, Co-60 tomotherapy's conformal dose delivery potential is evaluated by delivering conformal dose plans on a cylindrical homogeneous phantom containing clinical structures similar to those found in a typical head and neck (H and N) cancer. Also, the clinical potential of Co-60 tomotherapy is investigated by generating 2D clinical treatment plans for H and N and prostate anatomical regions. These plans are compared with the 6 MV based treatment plans for modalities such as linear accelerator-based tomotherapy and broad beam IMRT, and 15 MV based 3D conformal radiation therapy (3DCRT).Methods: For experimental validation studies, clinical and nonclinical conformal dose patterns were delivered on circular, homogeneous phantoms containing GafChromic film. For clinical planning study, dose calculations were performed with the EGSnrc Monte Carlo program, where a Theratronics 780C Co-60 unit and a 6 MV linear accelerator were modeled with a MIMiC binary multileaf collimator. An inhouse inverse treatment planning system was used to optimize tomotherapy plans using the same optimization parameters for both Co-60 and 6 MV beams. The IMRT and 3DCRT plans for the clinical cases were generated entirely in the Eclipse treatment planning system based on inhouse IMRT and 3DCRT site specific protocols.Results: The doses delivered to the homogeneous phantoms agreed with the calculations, indicating that it is possible to deliver highly conformal doses with the Co-60 unit. The dose distributions for Co-60 tomotherapy clinical plans for both clinical cases were similar to those obtained with 6 MV based tomotherapy and IMRT, and much more conformal compared to 3DCRT plans. The dose area histograms showed that the Co-60 plans achieve the dose objectives for the targets and organs at risk.Conclusions: These results confirm that Co-60 tomotherapy is capable of providing state-of-the-art conformal dose delivery and could be used for the treatment of targets in both small and larger separation anatomical regions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric evaluation of photon dose calculation under jaw and MLC shielding

Purpose: The accuracy of photon dose calculation algorithms in out-of-field regions is often neglected, despite its importance for organs at risk and peripheral dose evaluation. The present work has assessed this for the anisotropic analytical algorithm (AAA) and the Acuros-XB algorithms implemented in the Eclipse treatment planning system. Specifically, the regions shielded by the jaw, or the MLC, or both MLC and jaw for flattened and unflattened beams have been studied.Methods: The accuracy in out-of-field dose under different conditions was studied for two different algorithms. Measured depth doses out of the field, for different field sizes and various distances from the beam edge were compared with the corresponding AAA and Acuros-XB calculations in water. Four volumetric modulated arc therapy plans (in the RapidArc form) were optimized in a water equivalent phantom, PTW Octavius, to obtain a region always shielded by the MLC (or MLC and jaw) during the delivery. Doses to different points located in the shielded region and in a target-like structure were measured with an ion chamber, and results were compared with the AAA and Acuros-XB calculations. Photon beams of 6 and 10 MV, flattened and unflattened were used for the tests.Results: Good agreement between calculated and measured depth doses was found using both algorithms for all points measured at depth greater than 3 cm. The mean dose differences (±1SD) were −8%± 16%, −3%± 15%, −16%± 18%, and −9%± 16% for measurements vs AAA calculations and −10%± 14%, −5%± 12%, −19%± 17%, and −13%± 14% for Acuros-XB, for 6X, 6 flattening-filter free (FFF), 10X, and 10FFF beams, respectively. The same figures for dose differences relative to the open beam central axis dose were: −0.1%± 0.3%, 0.0%± 0.4%, −0.3%± 0.3%, and −0.1%± 0.3% for AAA and −0.2%± 0.4%, −0.1%± 0.4%, −0.5%± 0.5%, and −0.3%± 0.4% for Acuros-XB. Buildup dose was overestimated with AAA, while Acuros-XB gave results more consistent with measurements. From RapidArc plan analysis the average difference between calculation and measurement in the shielded region was −0.3%± 0.4% and −2.5%± 1.2% for AAA and Acuros-XB, respectively, relative to the mean target dose value (1.6%± 2.3%, −12.7%± 4.0% if relative to each local value). These values were compared with the corresponding differences in the target structure: −0.7%± 2.3% for AAA, and −0.5%± 2.3% for Acuros-XB.Conclusions: The two algorithms analyzed showed encouraging results in predicting out-of-field region dose for clinical use.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comprehensive investigation of the accuracy and reproducibility of a multitarget single isocenter VMAT radiosurgery technique

Purpose: Recent trends in stereotactic radiosurgery use multifocal volumetric modulated arc therapy (VMAT) plans to simultaneously treat several distinct targets. Conventional verification often involves low resolution measurements in a single plane, a cylinder, or intersecting planes of diodes or ion chambers. This work presents an investigation into the consistency and reproducibility of this new treatment technique using a comprehensive commissioned high-resolution 3D dosimetry system (PRESAGE{sup ®}/Optical-CT).Methods: A complex VMAT plan consisting of a single isocenter but five separate targets was created in Eclipse for a head phantom containing a cylindrical PRESAGE{sup ®} dosimetry insert of 11 cm diameter and height. The plan contained five VMAT arcs delivering target doses from 12 to 20 Gy. The treatment was delivered to four dosimeters positioned in the head phantom and repeated four times, yielding four separate 3D dosimetry verifications. Each delivery was completely independent and was given after image guided radiation therapy (IGRT) positioning using Brainlab ExacTrac and cone beam computed tomography. A final delivery was given to a modified insert containing a pin-point ion chamber enabling calibration of PRESAGE{sup ®} 3D data to dose. Dosimetric data were read out in an optical-CT scanner. Consistency and reproducibility of the treatment technique (including IGRT setup) was investigated by comparing the dose distributions in the four inserts, and with the predicted treatment planning system distribution.Results: Dose distributions from the four dosimeters were registered and analyzed to determine the mean and standard deviation at all points throughout the dosimeters. A dose standard deviation of <3% was found from dosimeter to dosimeter. Global 3D gamma maps show that the predicted and measured dose matched well [3D gamma passing rate was 98.0% (3%, 2 mm)].Conclusions: The deliveries of the irradiation were found to be consistent and matched the treatment plan, demonstrating high accuracy and reproducibility of both the treatment machine and the IGRT procedure. The complexity of the treatment (multiple arcs) and dosimetry (multiple strong gradients) pose a substantial challenge for comprehensive verification. 3D dosimetry can be uniquely effective in this scenario.

61 RADIATION PROTECTION AND DOSIMETRY↗

Video-rate optical dosimetry and dynamic visualization of IMRT and VMAT treatment plans in water using Cherenkov radiation

Purpose: A novel technique for optical dosimetry of dynamic intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 (TG-119) C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank doped with the fluorophore quinine sulfate. The ICCD acquisition was gated to the Linac target trigger pulse to reduce background light artifacts, read out for a single radiation pulse, and binned to a resolution of 512 × 512 pixels. The resulting videos were analyzed temporally for various regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR), and summed to obtain an overall light intensity distribution, which was compared to the expected dose distribution from the TPS using a gamma-index analysis. Results: The chosen camera settings resulted in 23.5 frames per second dosimetry videos. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.9% and 96.2% agreement between the experimentally captured Cherenkov light distribution and expected TPS dose distribution based upon a 3%/3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans, respectively. Conclusions: The results from this initial study demonstrate the first documented use of Cherenkov radiation for video-rate optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-18A-01: Tumor Motion Tracking with a Regional Deformable Registration Model for Four Dimensional Radiation Treatment of Lung Cancer

Purpose: To develop a tumor motion model from four-dimensional computed tomography (4DCT) of thoracic patients and demonstrate its impact on 4D radiation therapy simulation. Methods: A regional deformable image registration algorithm was introduced to extract tumor motion out of patient's breathing cycle. The gross target volume (GTV) was manually delineated on a selected phase of 4DCT and a subregion with 10mm margin supplemented to the GTV was created on the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). Together with 4DCT the structures were exported into an inhouse research platform. A free form B-Spline deformable registration was carried out to map the subregion to other respiratory phases. The displacement vector fields were employed to propagate GTV contours with which the center of mass (CoM) of the GTV was computed for each breathing phase of 4DCT. The resultant GTV motion and its volumetric shape are utilized to facilitate 4D treatment planning. Five lung cancer patients undergoing stereotactic body radiation therapy were enrolled and their 4DCT sets were included in the study. Results: Application of the algorithm to five thoracic patients indicates that clinically satisfactory outcomes were achievable with a spatial accuracy better than 2mm for GTV contour propagation between adjacent phases, and 3mm between opposite phases. The GTV CoM was found to be in the range of 2.0mm through 2.5cm, depending upon the tumor location. Compared to the traditional whole image based registration, the computation of the regional model was found to be an order of magnitude more efficient. Conclusion: A regional deformable registration model was implemented to extract tumor motion. It will have widespread application in 4D radiation treatment planning in the future to maximally utilize the available spatial-tempo information.

60 APPLIED LIFE SCIENCES↗

SU-E-I-75: Evaluation of An Orthopedic Metal Artifact Reduction (O-MAR) Algorithm On Patients with Spinal Prostheses Near Spinal Tumors

Purpose: To evaluate the impact of a commercial orthopedic metal artifact reduction (O-MAR) algorithm on CT image quality and dose calculation for patients with spinal prostheses near spinal tumors. Methods: A CT electron density phantom was scanned twice: with tissue-simulating inserts only, and with a titanium insert replacing solid water. A patient plan was mapped to the phantom images in two ways: with the titanium inside or outside of the spinal tumor. Pinnacle and Eclipse were used to evaluate the dosimetric effects of O-MAR on 12-bit and 16-bit CT data, respectively. CT images from five patients with spinal prostheses were reconstructed with and without O-MAR. Two observers assessed the image quality improvement from O-MAR. Both pencil beam and Monte Carlo dose calculation in iPlan were used for the patient study. The percentage differences between non-OMAR and O-MAR datasets were calculated for PTV-min, PTV-max, PTV-mean, PTV-V100, PTV-D90, OAR-V10Gy, OAR-max, and OAR-D0.1cc. Results: O-MAR improved image quality but did not significantly affect the dose distributions and DVHs for both 12-bit and 16- bit CT phantom data. All five patient cases demonstrated some degree of image quality improvement from O-MAR, ranging from small to large metal artifact reduction. For pencil beam, the largest discrepancy was observed for OARV-10Gy at 5.4%, while the other seven parameters were ≤0.6%. For Monte Carlo, the differences between non-O-MAR and O-MAR datasets were ≤3.0%. Conclusion: Both phantom and patient studies indicated that O-MAR can substantially reduce metal artifacts on CT images, allowing better visualization of the anatomical structures and metal objects. The dosimetric impact of O-MAR was insignificant regardless of the metal location, image bit-depth, and dose calculation algorithm. O-MAR corrected images are recommended for radiation treatment planning on patients with spinal prostheses because of the improved image quality and no need to modify current dose constraints. This work was supported by a research grant from Philips Healthcare. Paul Klahr is an employee of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-E-J-49: Distal Edge Activity Fall Off Of Proton Therapy Beams

Purpose: To characterize and quantify the distal edge activity fall off, created in a phantom by a proton therapy beam Method and Materials: A 30x30x10cm polymethylmethacrylate phantom was irradiated with a proton therapy beam using different ranges and beams. The irradiation volume is approximated by a right circular cylinder of diameter 7.6cm and varying lengths. After irradiation, the phantom was scanned via a Philips Gemini Big Bore™ PET-CT for isotope activation. Varian Eclipse™ treatment planning system as well as ImageJ™ were used to analyze the resulting PET and CT scans. The region of activity within the phantom was longitudinally measured as a function of PET slice number. Dose estimations were made via Monte Carlo (GATE) simulation. Results: For both the spread out Bragg peak (SOBP) and the mono-energetic pristine Bragg peak proton beams, the proximal activation rise was steep: average slope −0.735 (average intensity/slice number) ± 0.091 (standard deviation) for the pristine beams and −1.149 ± 0.117 for the SOBP beams. In contrast, the distal fall offs were dissimilar. The distal fall off in activity for the pristine beams was fit well by a linear curve: R{sup 2} (Pierson Product) was 0.9968, 0.9955 and 0.9909 for the 13.5, 17.0 and 21.0cm range beams respectively. The good fit allows for a slope comparison between the different ranges. The slope varied as a function of range from 1.021 for the 13.5cm beam to 0.8407 (average intensity/slice number) for the 21.0cm beam. This dependence can be characterized: −0.0234(average intensity/slice number/cm range). For the SOBP beams, the slopes were significantly less and were also less linear: average slope 0.2628 ± 0.0474, average R{sup 2}=0.9236. Conclusion: The distal activation fall off edge for pristine proton beams was linear and steep. The corresponding quantities for SOBP beams were shallower and less linear. Philips has provided support for this work.

07 ISOTOPE AND RADIATION SOURCES↗