Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY MODELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

NREL/OpenStudio

OpenStudio is a cross-platform collection of software tools to support whole building energy modeling using EnergyPlus and advanced daylight analysis using Radiance. This disclosure includes two OpenStudio measures: (1) data center prototype models, and (2) occupant schedule generator. The data center models cover two sizes (small computer server rooms, stand-alone large data centers) and two IT load densities (average and high).

Li, Han↗

OpenStudio® Server [SWR-07-40]

OpenStudio® Server is a web application and distributed computing tool, which is the backbone of the OpenStudio Analysis Framework (OSAF). It is intended to make parametric analysis of building energy models accessible to architects, engineers, and designers via the OpenStudio PAT GUI or the OpenStudio Analysis Gem. OpenStudio Server analyses are defined by PAT projects or OSA's. Each analysis may include many OpenStudio simulations, as determined by project configuration.

Long, Nicholas↗

Ladybug Tools IN2 Measures

Ladybug Tools IN2 Measures is a collection of OpenStudio® measures, file formats, scripts, and related tools for integrating Ladybug Tools with energy modeling via OpenStudio.

Macumber, Daniel↗

AERCalc v1.2.10

AERCalc is a software tool for evaluating the energy performance of window attachments (e.g., shading systems, attached window panels, etc.). All the annual energy modeling is performed by the EnergyPlus OS engine. The program incorporates a user-friendly GUI.

Mitchell, Robin↗

skyline

skyline is a header-only C++ library for the direct solution of linear algebraic equations that are stored in skyline format. It is intended for medium-sized sparse problems with moderate bandwidth. This solution approach has historically been used for pressure network solvers and in some finite element codes. It was developed to replace legacy solver code included in the EnergyPlus building energy modeling software package, but is not limited to use by EnergyPlus.

DeGraw, Jason↗

ACME Priority Metrics (A-PRIME)

A-PRIME, is a collection of scripts designed to provide Accelerated Climate Model for Energy (ACME) model developers and analysts with a variety of analysis of the model needed to determine if the model is producing the desired results, depending on the goals of the simulation. The software is csh scripts based at the top level to enable scientist to provide the input parameters. Within the scripts, the csh scripts calls code to perform the postprocessing of the raw data analysis and create plots for visual assessment.

Evans, KatherineJ.↗

Charging-management And Infrastructure-planning (cmip) Model

CMIP model explores various charging infrastructure network designs to serve a free-floating car-sharing fleet and determine the charging downtime experienced by the fleet for each design. Development of the CMIP model had two major steps: (1) describing modeling assumptions and (2) developing an integer program (IP) that jointly optimizes decisions about locations to install DC fast chargers and EV-to-charger assignments. The CMIP model integrates an EV charging model, EV energy consumption model, and heterogeneous, real-world vehicle use data with an integer programming optimization model to identify optimal location of new charging stations and calculate vehicle downtime for charging. The CMIP model can be applied to understand: (a) the reduction of EV fleet downtime if an additional fast-charging station is added to the current infrastructure and (b) to what extent total vehicle downtime would be sensitive to additional charging infrastructure.

Roni, MohammadS↗

EMF Biomass Data Interpreter [SWR-23-06]

EMF Biomass Data Interpreter was developed for the transportation team of the Energy Modeling Forum (EMF) 37: Deep Decarbonization and High Electrification Scenarios for North America project. It parses results from different modeling groups to show how biomass might be employed under electrification.

Wachs, Elizabeth↗

Automated Auditing Tool for Retrofit Building Projects [SWR-11-07]

Building energy auditors regularly use notepads, physical forms, or simple spreadsheets to inventory energy consuming devices in buildings and audit overall performance. Mobile computing devices such as smart phones or tablet computers with camera inputs may be used to automatically capture relevant information and format audit input in a way that streamlines work flows and reduces the likelihood of error. As an example. an auditor could walk through a space holding a mobile device, which automatically identifies and appliances, windows, etc. This information would automatically be added to a mobile database associated with the building for later integration with a larger building audit database. The user experience would require little or no manual input, and could integrate with tools to automate used to automate data collection for building energy modeling.

Parker, Andrew↗

pnnl/openstudio-building-energy-standard-measures-gem

The OpenStudio Building Energy Standards Measure Repository is a comprehensive collection of innovative OpenStudio measures designed to facilitate energy code analysis. OpenStudio is a cutting-edge platform brings together physics-based building energy modeling (BEM), BEM process automation, and large-scale computing capabilities. Contains OpenStudio Standards Performance Rating Method Measure (IPID 32936) and OpenStudio Measure to Generate IPLV-specific Chiller Performance Curves for Chillers (IPID 32940)

Xu, Weili [PNNL]↗

NucMesh: nuclear reactor geometry creation and mesh generation module in NEMoSys

NucMesh is a parameterized geometry and mesh generator for nuclear reactors developed within the Nuclear Energy Modeling System NEMoSys at Illinois Rocstar. NEMoSys is a platform developed for mesh generation, adaptive refinement, and solution verification. NucMesh is implemented to be generalized and extensible with a robust computer aided design engine and multiple mesh generation algorithms for unstructured triangular, quad-dominant, and structured quadrilateral meshing. In this paper, we present the geometric and meshing features of NucMesh. Geometrically objects are constructed bottom-to-top and overlaps are addressed automatically. A sophisticated object tracking algorithm prevents data from being lost for segmented objects. We discuss the primitive objects of circle and polygons that constitute the module and show how they are used with example inputs. Arrays of primitives and arrays of arrays are utilized to build large assemblies of objects. The concept of saved objects is discussed to demonstrate how repetitive objects can be reused easily and augmented in place. Three dimensional meshes can be obtained through mesh extrusion where all materials and side sets are extended to three dimensions. We show that side sets can be defined nearly anywhere within the geometry and can then be applied to the mesh. Finally, example reactor meshes are demonstrated for the Idaho National Laboratory Advanced Test Reactor and Los Alamos National Lab Empire reactor, both of which use control drums that NucMesh handles easily. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Strategy Guideline: Mitigation of Retrofit Risk Factors

The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis for the Chicago Energy Retrofit Project: Project Report

For the Chicago Loop Energy Efficiency Retrofit project, Argonne is developing and piloting analytic methods that capture the energy performance of individual commercial buildings; can be scaled to communities; and appropriately evaluate retrofit options in real contexts. The decision tools under development span and integrate building energy performance calculations, uncertainty analysis, and financial risk assessment. A key outcome from this project is an energy calculator, EECalc, developed in collaboration with the Georgia Institute of Technology. The energy modeling methodology used in EECalc was chosen specifically because it (1) is computationally efficient, (2) uses only observable building data that take a relatively low level of effort to compile, and (3) requires minimal modeling expertise and judgment from the user. These features expand the possibilities for EECalc’s widespread, large-scale use in retrofit and uncertainty analysis.

Guzowski, Leah B.↗

Strategy Guideline: Mitigation of Retrofit Risk Factors

The Alliance for Residential Building Innovation (ARBI) Building America team is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Short-Term Monitoring Results for Advanced New Construction Test House—Roseville, California

A builder (K. Hovnanian® Homes®), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft 2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols, while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic to conditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing of individual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Term Monitoring Results for Advanced New Construction Test House -- Roseville, California

A builder (K. Hovnanian Homes), design consultant, and trades collaborated to identify a systems integrated measures package for a 2,253-ft2 slab-on-grade ranch house to achieve a modeled energy savings of 60% with respect to the Building America House Simulation Protocols (Hendron, R. and Engebrecht, C. 'Building America House Simulation Protocols.' Golden, CO: National Renewable EnergyLaboratory, 2010) while minimizing construction costs and without requiring changes to the drawing that would impact local code or zoning approval. The key building improvements were applying R-10 insulation to the slab edge, increasing exterior wall cavity insulation from R-13 to R-15, and increasing attic insulation from R-30 to R-38. Also, the air handling unit was relocated from the attic toconditioned space, and ductwork was relocated along the attic floor with an insulated bulkhead built above it. Short-term testing results showed that duct air leakage was low due to short duct runs and the placement of ductwork in conditioned space. However, during commissioning, the lack of access for servicing the ductwork and dampers in the bulkhead area prevented retroactive balancing ofindividual branches, resulting in significant differences between specified and measured airflow values for some duct runs. Thermal imaging results performed on the house when operating in both heating and cooling modes validated historic stratification issues of ceiling supply registers with high supply air temperatures. Long-term monitoring results will be detailed in a future report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Cost-Effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007

The purpose of this analysis is to examine the cost-effectiveness of the 2010 edition of ANSI/ASHRAE/IES1 Standard 90.1. Standard 90.1 is the model energy standard for commercial and multifamily residential buildings over three floors (ECPA, Public Law 94-385). PNNL analyzed the cost-effectiveness of changes in Standard 90.1 from 90.1-2007 to 90.1-2010, as applied in the United States. During the development of new editions of Standard 90.1, the cost-effectiveness of individual changes (addenda) is often calculated to support the deliberations of Standard Standing Project Committee (SSPC) 90.1. The process does not include analysis of the cost-effectiveness of the entire package of addenda from one version of the standard to the next. Providing states with an analysis of cost-effectiveness may encourage more rapid adoption of newer editions of energy codes based on Standard 90.1. This information may also inform the development of future editions of Standard 90.1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗