Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

SUZAKU OBSERVATION OF A1689: ANISOTROPIC TEMPERATURE AND ENTROPY DISTRIBUTIONS ASSOCIATED WITH THE LARGE-SCALE STRUCTURE

We present results of new, deep Suzaku X-ray observations (160 ks) of the intracluster medium (ICM) in A1689 out to its virial radius, combined with complementary data sets of the projected galaxy distribution obtained from the SDSS catalog and the projected mass distribution from our recent comprehensive weak and strong lensing analysis of Subaru/Suprime-Cam and Hubble Space Telescope/Advanced Camera for Surveys observations. Faint X-ray emission from the ICM around the virial radius (r{sub vir} {approx} 15.'6) is detected at 4.0{sigma} significance, thanks to the low and stable particle background of Suzaku. The Suzaku observations reveal anisotropic gas temperature and entropy distributions in cluster outskirts of r{sub 500} {approx_lt} r {approx_lt} r{sub vir} correlated with large-scale structure of galaxies in a photometric redshift slice around the cluster. The high temperature ({approx}5.4 keV) and entropy region in the northeastern (NE) outskirts is apparently connected to an overdense filamentary structure of galaxies outside the cluster. The gas temperature and entropy profiles in the NE direction are in good agreement, out to the virial radius, with that expected from a recent XMM-Newton statistical study and with an accretion shock heating model of the ICM, respectively. On the contrary, the other outskirt regions in contact with low-density void environments have low gas temperatures ({approx}1.7 keV) and entropies, deviating from hydrostatic equilibrium. These anisotropic ICM features associated with large-scale structure environments suggest that the thermalization of the ICM occurs faster along overdense filamentary structures than along low-density void regions. We find that the ICM density distribution is fairly isotropic, with a three-dimensional density slope of -2.29 {+-} 0.18 in the radial range of r{sub 2500} {approx_lt} r {approx_lt} r{sub 500}, and with -1.24{sup +0.23}{sub -0.56} in r{sub 500} {approx_lt} r {approx_lt} r{sub vir}, which, however, is significantly shallower than the Navarro, Frenk, and White universal matter density profile in the outskirts, {rho} {proportional_to} r {sup -3}. A joint X-ray and lensing analysis shows that the hydrostatic mass is lower than the spherical-lensing one ({approx}60%-90%), but comparable to a triaxial halo mass within errors, at intermediate radii of 0.6r{sub 2500} {approx_lt} r {approx_lt} 0.8r{sub 500}. On the other hand, the hydrostatic mass within 0.4r{sub 2500} is significantly biased as low as {approx_lt}60%, irrespective of mass models. The thermal gas pressure within r{sub 500} is, at most, {approx}50%-60% of the total pressure to balance fully the gravity of the spherical-lensing mass, and {approx}30%-40% around the virial radius. Although these constitute lower limits when one considers the possible halo triaxiality, these small relative contributions of thermal pressure would require additional sources of pressure, such as bulk and/or turbulent motions.

79 ASTRONOMY AND ASTROPHYSICS↗

THE STELLAR AGES AND MASSES OF SHORT GAMMA-RAY BURST HOST GALAXIES: INVESTIGATING THE PROGENITOR DELAY TIME DISTRIBUTION AND THE ROLE OF MASS AND STAR FORMATION IN THE SHORT GAMMA-RAY BURST RATE

We present multi-band optical and near-infrared observations of 19 short {gamma}-ray burst (GRB) host galaxies, aimed at measuring their stellar masses and population ages. The goals of this study are to evaluate whether short GRBs track the stellar mass distribution of galaxies, to investigate the progenitor delay time distribution, and to explore any connection between long and short GRB progenitors. Using single stellar population models we infer masses of log(M{sub *}/M{sub sun}) {approx} 8.8-11.6, with a median of (log(M{sub *}/M{sub sun})) {approx} 10.1, and population ages of {tau}{sub *} {approx} 0.03-4.4 Gyr with a median of ({tau}{sub *}) {approx} 0.3 Gyr. We further infer maximal masses of log(M{sub *}/M{sub sun}) {approx} 9.7-11.9 by assuming stellar population ages equal to the age of the universe at each host's redshift. Comparing the distribution of stellar masses to the general galaxy mass function, we find that short GRBs track the cosmic stellar mass distribution only if the late-type hosts generally have maximal masses. However, there is an apparent dearth of early-type hosts compared to the equal contribution of early- and late-type galaxies to the cosmic stellar mass budget. Similarly, the short GRB rate per unit old stellar mass appears to be elevated in the late-type hosts. These results suggest that stellar mass may not be the sole parameter controlling the short GRB rate, and raise the possibility of a two-component model with both mass and star formation playing a role (reminiscent of the case for Type Ia supernovae). If short GRBs in late-type galaxies indeed track the star formation activity, the resulting typical delay time is {approx}0.2 Gyr, while those in early-type hosts have a typical delay of {approx}3 Gyr. Using the same stellar population models, we fit the broadband photometry for 22 long GRB host galaxies in a similar redshift range and find that they have significantly lower masses and younger population ages, with (log(M{sub *}/M{sub sun})) {approx} 9.1 and ({tau}{sub *}) {approx} 0.06 Gyr, respectively; their maximal masses are similarly lower, (log(M{sub *}/M{sub sun})) {approx} 9.6, and as expected do not track the galaxy mass function. Most importantly, the two GRB host populations remain distinct even if we consider only the star-forming hosts of short GRBs, supporting our previous findings (based on star formation rates and metallicities) that the progenitors of long and short GRBs in late-type galaxies are distinct. Given the much younger stellar populations of long GRB hosts (and hence of long GRB progenitors), and the substantial differences in host properties, we caution against the use of Type I and II designations for GRBs since this may erroneously imply that all GRBs which track star formation activity share the same massive star progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

THE BLACK HOLE MASS DISTRIBUTION IN THE GALAXY

We use dynamical mass measurements of 16 black holes in transient low-mass X-ray binaries to infer the stellar black hole mass distribution in the parent population. We find that the observations are best described by a narrow mass distribution at 7.8 {+-} 1.2 M{sub sun}. We identify a selection effect related to the choice of targets for optical follow-ups that results in a flux-limited sample. We demonstrate, however, that this selection effect does not introduce a bias in the observed distribution and cannot explain the absence of black holes in the 2-5 M{sub sun} mass range. On the high-mass end, we argue that the rapid decline in the inferred distribution may be the result of the particular evolutionary channel followed by low-mass X-ray binaries. This is consistent with the presence of high-mass black holes in the persistent, high-mass X-ray binary sources. If the paucity of low-mass black holes is caused by a sudden decrease of the supernova explosion energy with increasing progenitor mass, this would have observable implications for ongoing transient surveys that target core-collapse supernovae. Our results also have significant implications for the calculation of event rates from the coalescence of black hole binaries for gravitational wave detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Power Distribution System Management With a Locally Connected Communication Network

Coordinated optimization and control of distribution-level assets can enable a reliable and optimal integration of massive amount of distributed energy resources (DERs) and facilitate distribution system management (DSM). Accordingly, the objective is to coordinate the power injection at the DERs to maintain certain quantities across the network, e.g., voltage magnitude, line flows, or line losses, to be close to a desired profile. By and large, the performance of the DSM algorithms has been challenged by two factors: i) the possibly non-strongly connected communication network over DERs that hinders the coordination; ii) the dynamics of the real system caused by the DERs with heterogeneous capabilities, time-varying operating conditions, and real-time measurement mismatches. In this paper, we investigate the modeling and algorithm design and analysis with the consideration of these two factors. In particular, a game theoretic characterization is first proposed to account for a locally connected communication network over DERs, along with the analysis of the existence and uniqueness of the Nash equilibrium (NE) therein. To achieve the equilibrium in a distributed fashion, a projected-gradient-based asynchronous DSM algorithm is then advocated. The algorithm performance, including the convergence speed and the tracking error, is analytically guaranteed under the dynamic setting. In conclusion, extensive numerical tests on both synthetic and realistic cases corroborate the analytical results derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network-Cognizant Time-Coupled Aggregate Flexibility of Distribution Systems Under Uncertainties

Increasing integration of distributed energy resources (DERs) within distribution feeders provides unprecedented flexibility at the distribution-transmission interconnection. To exploit this flexibility and to use the capacity potential of aggregate DERs, feasible substation power injection trajectories need to be efficiently characterized. This paper provides an ellipsoidal inner approximation of the set of feasible power injection trajectories at the substation such that for any point in the set, there exists a feasible disaggregation strategy of DERs for any load uncertainty realization. The problem is formulated as one of finding the robust maximum volume ellipsoid inside the flexibility region under uncertainty. Though the problem is NP-hard even in the deterministic case, this paper derives novel approximations of the resulting adaptive robust optimization problem based on optimal second-stage policies. The proposed approach yields less conservative flexibility characterization than existing flexibility region approximation formulations. The efficacy of the proposed method is demonstrated on a realistic distribution feeder.

adaptive robust optimization↗

Data-Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration

Dynamic, scalable, and interoperable control paradigms are required to enable efficient, secure, reliable, and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research on developing a novel, holistic, data-enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control with distributed grid-edge control and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

Real-Time Feedback-Based Optimization of Distribution Grids: A Unified Approach

This paper develops an algorithmic framework for real-time optimization of distribution-level distributed energy resources (DERs). The framework optimizes the operation of both DERs that are individually controllable and groups of DERs (i.e., aggregations) that are jointly controlled at an electrical point of connection. From an electrical standpoint, wye and delta single- and multi-phase connections are accounted for. The algorithm enables (groups of) DERs to pursue given performance objectives, while adjusting their (aggregate) powers to respond to services requested by grid operators and to maintain electrical quantities within engineering limits. The design of the algorithm leverages a time-varying bi-level problem formulation capturing various performance objectives and engineering constraints, and an online implementation of primal-dual projected-gradient methods. The gradient steps are suitably modified to accommodate appropriate measurements from the distribution network and the DERs. Stability and convergence claims are established in terms of tracking of the solution of the time-varying optimization problem. Finally, the method is tested in a realistic distribution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Experimental Validation of a High-Power DC Distribution Testbed for Advanced Charging Infrastructure and Energy Management

This paper presents the development of a hardware testbed for DC-distributed high-power charging (HPC) stations. As DC distributed solutions emerge as a viable solution to optimize HPC site operations, challenges such as interoperability, protection, and seamless integration of distributed energy resources (DER) persist. These issues underscore the need for a robust testing facility to investigate compliance of available commercial off-the-shelf (COTS) market devices. The developed testbed features a DC-distributed charging hub including a charger, emulated energy storage system (ESS), and site level communication and controller implementation. It facilitates the testing of COTS hardware, charger prototypes, standards validation and site energy management system (SEMS) controllers at rated power. This paper details the development of the charging infrastructure platform, implementation of communication system, validation of different SEMS algorithms, and understanding improvements required for future expansion. Using the developed testbed, interoperability gaps for SEMS implementation with multi-vehicle concurrent charging via a multi-port charger are experimentally observed. Aimed at supporting the transition to large-scale EV charging infrastructure deployment and DER integration, this testbed plays a crucial role in conformity testing of COTS device interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network-Level Optimization for Unbalanced Power Distribution System: Approximation and Relaxation

The nonlinear programming (NLP) problem to solve distribution-level optimal power flow (D-OPF) poses convergence issues and does not scale well for unbalanced distribution systems. The existing scalable D-OPF algorithms either use approximations that are not valid for an unbalanced power distribution system, or apply relaxation techniques to the nonlinear power flow equations that do not guarantee a feasible power flow solution. In this paper, we propose scalable D-OPF algorithms that simultaneously achieve optimal and feasible solutions by solving multiple iterations of approximate, or relaxed, D-OPF subproblems of low complexity. The first algorithm is based on a successive linear approximation of the nonlinear power flow equations around the current operating point, where the D-OPF solution is obtained by solving multiple iterations of a linear programming (LP) problem. The second algorithm is based on the relaxation of the nonlinear power flow equations as conic constraints together with directional constraints, which achieves optimal and feasible solutions over multiple iterations of a second-order cone programming (SOCP) problem. Finally, it is demonstrated that the proposed algorithms are able to reach an optimal and feasible solution while significantly reducing the computation time as compared to an equivalent NLPD-OPF model for the same distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Distribution State Estimation for Reliable Locational Marginal Pricing under Cyber-Attacks

Here this paper examines the impact of false data injection (FDI) cyber-attacks on distribution system state estimation (DSSE) and the resulting distribution locational marginal price (DLMP) in power markets. Two robust high-breakdown regression estimators, namely S- and MM- estimators, are implemented to provide resistance against FDI attacks targeting measurements and grid topology, creating leverage points. The introduced estimators are compared to the weighted least squares (WLS) with a bad data detection and rejection module (BDD) and the robust Huber M-estimator. The proposed estimators are shown to be effective and compare favorably to both existing Huber M- and the WLS with BDD in the presence of topology FDI attacks. Both the S- and MM-estimators provide good performance in the case of clean and corrupted measurements. Their performance is comparable in this case to the Huber M- and the WLS, followed by a BDD module. The simulation considered a modified distribution IEEE 13 and 34-bus systems where the impact of FDI attack scenarios is shown on the state and the DLMP pricing in the presence of distributed Generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Controllers Seeking AC Optimal Power Flow Solutions Using ADMM

This paper focuses on power distribution systems with inverter-interfaced renewable energy sources (RESs), and develops a distributed control framework to steer the RES output powers to solutions of ac optimal power flow (OPF) problems. The design of the distributed control algorithm is based on suitable linear approximation of the ac power-flow equations, and leverages the so-called alternating direction method of multipliers (ADMM). Convergence of the RES-inverter output powers to solutions of the approximate ac OPF problem is established under suitable conditions on the mismatches between the commanded setpoints and actual RES output powers. Overall, since the proposed scheme can be cast as an ADMM with inexact primal and dual updates, the convergence results can be applied to more general distributed optimization settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Operation of Soft Open Points in Active Distribution Networks Under Three-Phase Unbalanced Conditions

The asymmetric integration of distributed generators (DGs) exacerbates the three-phase unbalanced condition in distribution systems. The serious unbalanced operation causes inefficient utilization of network assets and security risks in the system. Soft open point (SOP) is a flexible power electronic device which can achieve accurate active and reactive power flow control to balance the power flow among phases. This paper proposes an SOPs-based operation strategy for unbalanced active distribution networks (ADNs). By regulating the operation of SOPs, the strategy can reduce power losses and simultaneously mitigate the three-phase unbalance of the upper-level grid. Semidefinite programming (SDP) relaxation is advocated to convert the original non-convex, nonlinear optimization model into an SDP formulation, which can be efficiently solved to meet the requirement of rapid adjustment. Case studies are conducted on the modified IEEE 33-node and IEEE 123-node distribution system to verify the effectiveness and efficiency of the proposed strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Optimization for Networked Distributed Energy Resources With Time-Coupling Constraints

This paper proposes a Lyapunov optimization-based online distributed (LOOD) algorithmic framework for active distribution networks (ADNs) with numerous photovoltaic inverters and inverter air conditionings (IACs). In the proposed scheme, ADNs can track an active power setpoint reference at the substation in response to transmission-level requests while concurrently minimizing the social utility loss and ensuring the security of voltages. Conventional distributed optimization methods are rarely feasible to track the optimal solutions in fast variable environments using a fine-grained sampling interval where the underlying optimization problem evolves with the iterations of the algorithms. In contrast, based on the framework of online convex optimization (OCO), the developed approach uses a distributed algebraic update to compute the next round decisions relying on the current feedback of measurements. Notably, the time-coupling constraints of IACs are decoupled for online implementation with Lyapunov optimization technique. An incentive scheme is tailored to coordinate the customer-owned assets in lieu of the direct control from network operators. Optimality and convergency are characterized analytically. Finally, we corroborate the proposed method on a modified version of 33-node test feeder. Benchmark tests show that the proposed method is computationally and economically efficient, and outperforming existing algorithms.

active distribution networks↗

Attention Enabled Multi-Agent DRL for Decentralized Volt-VAR Control of Active Distribution System Using PV Inverters and SVCs

This paper proposes attention enabled multi-agent deep reinforcement learning (MADRL) framework for active distribution network decentralized Volt-VAR control. Using the unsupervised clustering, the whole distribution system can be decomposed into several sub-networks according to the voltage and reactive power sensitivity relationships. Then, the distributed control problem of each sub-network is modeled as Markov games and solved by the improved MADRL algorithm, where each sub-network is modeled as an adaptive agent. An attention mechanism is developed to help each agent focus on specific information that is mostly related to the reward. All agents are centrally trained offline to learn the optimal coordinated Volt-VAR control strategy and executed in a decentralized manner to make online decisions with only local information. Compared with other distributed control approaches, the proposed method can effectively deal with uncertainties, achieve fast decision makings, and significantly reduce the communication requirements. Comparison results with model-based and other data-driven methods on IEEE 33-bus and 123-bus systems demonstrate the benefits of the proposed approach.

distribution network↗

Distributed Generation Valuation and Compensation

This white paper can help guide a state as it considers issues associated with distributed generation valuation and compensation. States may address a common set of questions and issues in the valuation process, but differences in market expectations, policy priorities, and regulations result in different responses. Key issues include: Context is important. Valuations and compensation strategies will vary based on goals and objectives they are being designed to achieve. Goals and objectives should be made clear up front and will drive the perspective used in performing valuations and how outcomes are applied. Utilities and stakeholders can have different interpretations of how value elements should be calculated. In some states, the objective of standardized calculators and methods is to reduce ambiguity and inconsistencies in how valuations are performed. Certain value elements are difficult or impossible to quantify and most efforts to establish workable value of solar or value of distributed energy resource tariffs are emerging and nascent. Assessing locational and temporal value of distributed generation and applying that in compensation schemes is a new and emerging field of study, being explored by a handful of research organizations and advanced states and utilities. The most advanced states, such as California, are using demonstration projects to test valuation and compensation methodologies or are applying valuation and compensation strategies to a subset of customer projects, such as for community solar projects (e.g., Oregon and New York) before rolling out programs to the full customer base. A variety of states are moving away from full net metering, in many cases substituting avoided cost rates (sometimes with an adder) in lieu of full retail rate compensation, instead of pursuing valuation of distributed energy resource approaches. For example, in Indiana a 25% adder is applied to average wholesale electricity prices and in Mississippi a 2.5 cents/kWh adder is applied to avoided cost rates. These adders appear to have been established through policy directives rather than a comprehensive cost of service valuations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Wind Market Report: 2022 Edition

The U.S. Department of Energy’s (DOE’s) annual Distributed Wind Market Report analyzes distributed wind projects of all sizes to provide stakeholders with market statistics and analysis along with insights into market trends and characteristics. By providing a comprehensive overview of the distributed wind market, this report can help guide future investments and decisions by industry, utilities, federal and state agencies, and other interested parties. This report provides key information to help stakeholders understand and access market opportunities and inform distributed wind industry research and development needs.

17 WIND ENERGY↗

Interconnection of Distributed Energy Resources in the Indian Context: IEEE 1547-2018 Adaptation for Locally-Appropriate Grid Code Development

The rapid growth of distributed energy resources (DERs) in India and ambitious renewable energy goals set forth by the Indian government have created the need for appropriate distribution interconnection standards to ensure continued system stability, reliability, and resilience. Existing DER interconnection codes in India, at the time of publishing this report, lack many of the critical grid support functionalities for DERs which may protect bulk system stability, such as event ride-through provisions, frequency droop control, or appropriate trip thresholds given the increasing importance of distributed generation. The formal adoption of IEEE 1547-2018 by the Bureau of Indian Standards (BIS) marks a significant step towards achieving appropriate interconnection of DERs, though the implementation of such a standard must be accompanied with careful consideration of the current codes, regulations, and operation of the Indian power system. Studies on the performance of the functionalities within 1547-2018, which properly incorporate local operating conditions, can inform decisions related to the adoption and adaptation of the clauses present in the standard. This report outlines several of these key considerations for stakeholders and provides analyses illustrating the performance of grid support functionalities on typical Indian distribution feeders.

1547↗