Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determination and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Ultrasonic sensors and methods of using the ultrasonic sensors

An ultrasonic sensor comprises a transducer in operable communication with a power source, a waveguide comprising a metal and at least one of a fissile material or a fertile material in operable communication with the transducer and configured to propagate and reflect acoustic waves generated by the transducer, the transducer configured to convert reflected acoustic waves to an electric signal, a thermally insulative material proximate the waveguide, and a control system in operable communication with the transducer, the control system configured to determine at least a temperature of the waveguide based on the reflected acoustic waves. Related methods are also disclosed.

Woolstenhulme, Nicolas E.↗

Application of 'Six Sigma{sup TM}' and 'Design of Experiment' for Cementation - Recipe Development for Evaporator Concentrate for NPP Ling AO, Phase II (China) - 12555

Cementation of radioactive waste is a common technology. The waste is mixed with cement and water and forms a stable, solid block. The physical properties like compression strength or low leach ability depends strongly on the cement recipe. Due to the fact that this waste cement mixture has to fulfill special requirements, a recipe development is necessary. The Six Sigma{sup TM}' DMAIC methodology, together with the Design of experiment (DoE) approach, was employed to optimize the process of a recipe development for cementation at the Ling Ao nuclear power plant (NPP) in China. The DMAIC offers a structured, systematical and traceable process to derive test parameters. The DoE test plans and statistical analysis is efficient regarding the amount of test runs and the benefit gain by getting a transfer function. A transfer function enables simulation which is useful to optimize the later process and being responsive to changes. The DoE method was successfully applied for developing a cementation recipe for both evaporator concentrate and resin waste in the plant. The key input parameters were determined, evaluated and the control of these parameters were included into the design. The applied Six Sigma{sup TM} tools can help to organize the thinking during the engineering process. Data are organized and clearly presented. Various variables can be limited to the most important ones. The Six Sigma{sup TM} tools help to make the thinking and decision process trace able. The tools can help to make data driven decisions (e.g. C and E Matrix). But the tools are not the only golden way. Results from scoring tools like the C and E Matrix need close review before using them. The DoE is an effective tool for generating test plans. DoE can be used with a small number of tests runs, but gives a valuable result from an engineering perspective in terms of a transfer function. The DoE prediction results, however, are only valid in the tested area. So a careful selection of input parameter and their limits for setting up a DoE is very important. An extrapolation of results is not recommended because the results are not reliable out of the tested area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid circuit breakers

In one aspect, a hybrid circuit protection device for current-limiting a fault current between a source and a load during a fault is provided. The hybrid circuit protection device includes an input configured to couple to the source, an output configured to couple to the load, a return configured to couple the source to the load, a main switch configured to selectively couple the input to the output, a switching network coupled in parallel with the main switch, and a controller. The controller is configured to determine that the main switch has opened in response to the fault current, where the fault current has an initial value, and activate the switching network to current-limit the fault current to less than the initial value during the fault.

Qi, Li↗

Wind-tunnel Tests of a Model of a Wingless Fin-controlled Missile to Obtain Static Stability and Control Characteristics Through a Range of Mach Numbers from 0.5 to 0.88

An investigation at medium to high subsonic speeds has been conducted in the Langley low-turbulence pressure tunnel to determine the static stability and control characteristics and to measure the fin normal forces and moments for a model of a wingless fin-controlled missile. The data were obtained at Reynolds number of 2.1 x 10(6) based on the missile maximum diameter or 17.7 x 10(6) based on missile length; this Reynolds number was found to be large enough to avoid any large scale effects between the test and the expected flight Reynolds number. With the horizontal-fin deflection limited to a maximum of 6 degrees, longitudinally stable and trimmed flight could not be maintained beyond an angle of attack of 17 degrees for a Mach number of 0.88 and beyond 20 degrees for a Mach number of 0.50 for any center-of-gravity location without the use of some auxiliary stability or control device such as jet vanes. Mach number had no appreciable effect on the center-of-pressure positions and only a slight effect on neutral-point position. There was a shift in neutral-point position of about 1 caliber as the angle of attack was varied through the range for which the neutral point could be determined. Yawing the model to angles of sideslip up to 7 degrees had little effect on the longitudinal stability at angles of attack up to 15 degrees; however, above 15 degrees, the effect of sideslip was destabilizing. With the vertical fins at a plus-or-minus 6 degree roll deflection, the rolling moment caused by yawing the model at high angles of attack could be trimmed out up to angles of sideslip of 6.5 degrees and an angle of attack of 26 degrees for a Mach number of 0.50; this range of sideslip angles was reduced to 3 degrees at a Mach number of 0.88. The data indicated that, at lower angles of attack, the trim range extended to higher angles of sideslip. The total normal-force and hinge-moment coefficients for both horizontal fins were slightly nonlinear with both angle-of-attack and fin deflection. The effect of Mach number was to reduce the slopes of the hinge-moment coefficient with angle of attack and deflection angle. In general, the effort of increasing the sideslip angle was to reduce the values of the fin normal-force and hinge-moment coefficients.

Burrows, Dale L↗

Electron beam quality control using an amorphous silicon EPID

An amorphous silicon EPID has been investigated to determine whether it is capable of quality control constancy measurements for linear accelerator electron beams. The EPID grayscale response was found to be extremely linear with dose over a wide dose range and, more specifically, for exposures of 95-100 MU. Small discrepancies of up to 0.8% in linearity were found at 6 MeV (8-15 MeV showed better agreement). The shape of the beam profile was found to be significantly altered by scatter in air over the approximately 60 cm gap between the end of the applicator and the EPID. Nevertheless, relative changes in EPID-measured profile flatness and symmetry were linearly related to changes in these parameters at 95 cm focus to surface distance (FSD) measured using a 2D diode array. Similar results were obtained at 90 deg. and 270 deg. gantry angles. Six months of daily images were acquired and analyzed to determine whether the device is suitable as a constancy checker. EPID output measurements agreed well with daily ion chamber measurements, with a 0.8% standard deviation in the difference between the two measurement sets. When compared to weekly parallel plate chamber measurements, this figure dropped to 0.5%. A Monte Carlo (MC) model of the EPID was created and demonstrated excellent agreement between MC-calculated profiles in water and the EPID at 95 and 157 cm FSD. Good agreement was also found with measured EPID profiles, demonstrating that the EPID provides an accurate measurement of electron profiles. The EPID was thus shown to be an effective method for performing electron beam daily constancy checks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for determining tow parameters

A system for determining one or more characteristics of a carbon fiber tow. The system including a first laser profilometer, a second laser profilometer, and a controller. The first laser profilometer is located on a first side of the carbon fiber tow. The second laser profilometer is located on a second side of the carbon fiber tow. The controller is configured to receive, from the first profilometer, a first profile of the first side of the carbon fiber tow, and receive, from the second profilometer, a second profile of the second side of the carbon fiber tow. The controller is further configured to determine at least one characteristic selected from a group consisting of a tow width of the carbon fiber tow, a tow fuzz of the carbon fiber tow, a tow thickness of the carbon fiber tow, and a tow angle of the carbon fiber tow, the at least one characteristic based on the first profile and the second profile. The controller further configured to output the at least one characteristic of the carbon fiber tow.

36 MATERIALS SCIENCE↗

Phenylbutyrate Mouthwash Mitigates Oral Mucositis During Radiotherapy or Chemoradiotherapy in Patients With Head-and-Neck Cancer

Purpose: Deleterious oral mucositis (OM) develops during radiotherapy (RT) or chemoradiotherapy for head-and-neck cancer (HNC) patients. There are currently no effective cytoprotective treatments for OM without a potential risk of tumor protection. This randomized, double-blind, placebo-controlled pilot study aimed to determine the therapeutic safety and efficacy of phenylbutyrate (an antitumor histone deacetylase inhibitor and chemical chaperone) 5% mouthwash for treating OM caused by cancer therapy. Methods and Materials: Between September 2005 and June 2006, 36 HNC patients were randomized to standard oral care plus 5 mL of either phenylbutyrate 5% mouthwash (n = 17) or placebo (mouthwash vehicle, n = 19) taken four times daily (swish and spit). Treatment began when mild mucositis (Radiation Therapy Oncology Group Grade 1) occurred, and ended 4 weeks after RT completion. Safety and efficacy were based on adverse events, physical examination, laboratory determinations, vital signs, Oral Mucosa Assessment Scale (OMAS) and World Health Organization scores, the ability to eat, body weight change, local control, and survival. Results: We found no severe drug-related side effect. At RT doses of 5500-7500 cGy, phenylbutyrate significantly mitigated the severity of mucositis compared with placebo, based on both the WHO score (severity {>=} 3; p = 0.0262) and the OMAS scale (ulceration score {>=} 2; p = 0.0049). The Kaplan-Meier estimates for 2- and 3-year local control, and overall survival were 100% and 80.8%, and 78.6% and 64.3%, respectively, in the phenylbutyrate group and 74.2% and 74.2%, and 57.4% and 50.2%, respectively, in the placebo group. Conclusions: This pilot trial suggested that phenylbutyrate mouthwash significantly decreased the impact of OM in HNC patients receiving RT or chemoradiotherapy and did not confront the tumor control. Larger Phase II randomized trials are needed to confirm these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical operator method

Algebraic solutions of difference equations - stability of sampled-data control systems - numerical method for determining transients in electric systems excited by complex signals

ELECTRIC NETWORK↗

Fast-spectrum space-power-reactor concepts using boron control devices

Several fast-spectrum space power reactor concepts that use boron carbide control devices were examined to determine the neutronic feasibility of the designs. The designs considered were (1) a 199-fuel-pin, 12-poison-reflector-control-drum reactor; (2) a 232-fuel-pin reactor with 12 reflector drums and three in-core control rods; (3) a 337-fuel-pin design with 12 incore control rods; and a 181-fuel-pin design with six drums closely coupled to the core to increase reactivity per drum. Adequate reactivity control and excess reactivity could be obtained for each concept, and the goals of 50,000 hours at 2.17 thermal megawatts with a lithium-7 coolant outlet temperature of 1222 K could be met without exceeding the 1-percent-clad-creep criterion. Heating rates in the boron carbide were calculated, but a heat transfer analysis was not done.

Mayo, W.↗

A feedback control for the advanced launch system

A robust feedback algorithm is presented for a near-minimum-fuel ascent of a two-stage launch vehicle operating in the equatorial plane. The development of the algorithm is based on the ideas of neighboring optimal control and can be derived into three phases. In phase 1, the formalism of optimal control is employed to calculate fuel-optimal ascent trajectories for a simple point-mass model. In phase 2, these trajectories are used to numerically calculate gain functions of time for the control(s), the total flight time, and possibly, for other variables of interest. In phase 3, these gains are used to determine feedback expressions for the controls associated with a more realistic model of a launch vehicle. With the Advanced Launch System in mind, all calculations are performed on a two-stage vehicle with fixed thrust history, but this restriction is by no means important for the approach taken. Performance and robustness of the algorithm is found to be excellent.

Seywald, Hans↗

Longitudinal Stability and Control Characteristics from a Flight Investigation of a Cruciform Canard Missile Configuration Having an Exposed Wing-canard Area Ratio of 16:1

A flight investigation has been made to determine the longitudinal stability and control characteristics of a 60 0 delta-wing-canard missile configuration with an exposed wing-canard area ratio of 16:1. The results presented include the longitudinal stability derivatives, control effectiveness, and drag characteristics for a Mach number range of 0.75 to 1.80 and are compared with the results of a similar configuration having larger 6ontrols. Stability characteristics are also presented from the flights of an interdigitated canard configuration at a Mach number of 2.08 and a wing-body configuration at Mach numbers of 1.25 to 1.45. The stability derivatives varied gradually with Mach number with the exception of the damping-in-pitch derivative. Aerodynamic damping in pitch decreased to a minimum at a Mach number of 1.0 3, then increased to a peak value at a Mach number of 1.26 followed by a gradual decrease at higher Mach numbers. The aerodynamic-center location of the in-line canard configuration shifted rearward 13 percent of the mean aerodynamic chord at transonic speeds. The pitching-moment curve slope was 25 percent greater for the model having no canards than for the in-line configuration. No large effects of interdigitation were noted in the stability derivatives. Pitching effectiveness of the in-line configuration was maintained throughout the Mach number range. A comparison of the stability and control characteristics of two canard configurations having different area controls showed that decreasing the control area 44 percent decreased the pitching effectiveness proportionally, shifted the aerodynamic-center location rearward 9 to 14 percent of the mean aerodynamic chord, and reduced the total hinge moments required for 10 trimmed flight about 50 percent at transonic speeds.

Moul, Martin T↗

Precision Attitude Control for the BETTII Balloon-Borne Interferometer

The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-meter baseline far-infrared interferometer to fly on a high altitude balloon. Operating at wavelengths of 30-90 microns, BETTII will obtain spatial and spectral information on science targets at angular resolutions down to less than half an arcsecond, a capability unmatched by other far-infrared facilities. This requires attitude control at a level ofless than a tenth of an arcsecond, a great challenge for a lightweight balloon-borne system. We have designed a precision attitude determination system to provide gondola attitude knowledge at a level of 2 milliarcseconds at rates up to 100Hz, with accurate absolute attitude determination at the half arcsecond level at rates of up to 10Hz. A mUlti-stage control system involving rigid body motion and tip-tilt-piston correction provides precision pointing stability to the level required for the far-infrared instrument to perform its spatial/spectral interferometry in an open-loop control. We present key aspects of the design of the attitude determination and control and its development status.

Benford, Dominic J.↗

Influence of quality control variables on failure of graphite/epoxy under extreme moisture conditions

Tension tests on graphite/epoxy composites were performed to determine the influence of various quality control variables on failure strength as a function of moisture and moderate temperatures. The extremely high and low moisture contents investigated were found to have less effect upon properties than did temperature or the quality control variables of specimen flaws and prepreg batch to batch variations. In particular, specimen flaws were found to drastically reduce the predicted strength of the composite, whereas specimens from different batches of prepreg displayed differences in strength as a function of temperature and extreme moisture exposure. The findings illustrate the need for careful specimen preparation, studies of flaw sensitivity, and careful quality control in any study of composite materials.

Clements, L. L.↗

Influence of quality control variables on failure of graphite/epoxy under extreme moisture conditions

Tension tests on graphite/epoxy composites were performed to determine the influence of various quality control variables on failure strength as a function of moisture and moderate temperatures. The extremely high and low moisture contents investigated were found to have less effect upon properties than did temperature or the quality control variables of specimen flaws and prepreg batch to batch variations. In particular, specimen flaws were found to drastically reduce the predicted strength of the composite, whereas specimens from different batches of prepreg displayed differences in strength as a function of temperature and extreme moisture exposure. The findings illustrate the need for careful specimen preparation, studies of flaw sensitvity, and careful quality control in any study of composite materials. Previously announced in STAR as N80-33493

Clements, L. L.↗

Pivotable strakes for high angle of attack control

A series of pivotable strakes have been tested in combination with a 44-deg swept wing to determine their ability to provide pitch control at high angles of attack. The tests were carried out in the Langley 7 X 10-Foot High-Speed tunnel at nominal Mach numbers of 0.3 to 0.4. A total of five strakes with various aspects ratios and shapes were tested at negative deflection angles of 5, 10, 15, and 20 deg through an angle of attack range up to approximately 50 deg. In addition, a cranked delta wing with 70-deg sweep was tested with two different pivotable apex flaps. This paper shows lift, drag and moment data for the complete configurations as well as for the separate contributions of the strakes and fuselage nose which are mounted on a second balance. Generally, strake deflection was found to have a significant effect on moment while lift/drag changed very little.

Bobbitt, P. J.↗

PLC backplane analyzer for field forensics and intrusion detection

The various technologies presented herein relate to the determination of unexpected and/or malicious activity occurring between components communicatively coupled across a backplane. Control data, etc., can be intercepted at a backplane where the backplane facilitates communication between a controller and at least one device in an automation process. During interception of the control data, etc., a copy of the control data can be made, e.g., the original control data can be replicated to generate a copy of the original control data. The original control data can continue on to its destination, while the control data copy can be forwarded to an analyzer system to determine whether the control data contains a data anomaly. The content of the copy of the control data can be compared with a previously captured baseline data content, where the baseline data can be captured for a same operational state as the subsequently captured control data.

97 MATHEMATICS AND COMPUTING↗

Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

Purpose: The aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans. Methods: Retrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only. Results: The complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21). Conclusion: Complications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Monte Carlo analysis of the effects of instrumentation errors on aircraft parameter identification

An output error estimation algorithm was used to evaluate the effects of both static and dynamic instrumentation errors on the estimation of aircraft stability and control parameters. A Monte Carlo analysis, using simulated cruise flight data, was performed for a high performance military aircraft, a large commercial transport, and a small general-aviation aircraft. The effects of variations in the information content of the flight data, resulting from two different choices of control input maneuvers, were also determined. The results indicate that unmodeled instrumentation errors can cause inaccuracies in the estimated parameters which are comparable to their nominal values. Control input errors and angular accelerometer lags were found to be most significant of the instrumentation errors evaluated, and the perturbations they produce are much larger than those arising from the combined effects of static errors and white noise in the output response measurements.

Bryant, W. H.↗