Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Event shapes and azimuthal correlations in Z + jets events in pp collisions at s = 7 TeV

Measurements of event shapes and azimuthal correlations are presented for events where a Z boson is produced in association with jets in proton-proton collisions. The data collected with the CMS detector at the CERN LHC at sqrt(s) = 7 TeV correspond to an integrated luminosity of 5.0 inverse femtobarns. The analysis provides a test of predictions from perturbative QCD for a process that represents a substantial background to many physics channels. Results are presented as a function of jet multiplicity, for inclusive Z boson production and for Z bosons with transverse momenta greater than 150 GeV, and compared to predictions from Monte Carlo event generators that include leading-order multiparton matrix-element (with up to four hard partons in the final state) and next-to-leading-order simulations of Z + 1-jet events. The experimental results are corrected for detector effects, and can be compared directly with other QCD models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust measurement of supernova ν e spectra with future neutrino detectors

Measuring precise all-flavor neutrino information from a supernova is crucial for understanding the core-collapse process as well as neutrino properties. We apply a chi-squared analysis for different detector setups to explore determination of ν e spectral parameters. Using a long-term two-dimensional core-collapse simulation with three time-varying spectral parameters, we generate mock data to examine the capabilities of the current Super-Kamiokande detector and compare the relative improvements that gadolinium, Hyper-Kamiokande, and DUNE would have. We show that in a realistic three spectral parameter framework, the addition of gadolinium to Super-Kamiokande allows for a qualitative improvement in νe determination. Efficient neutron tagging will allow Hyper-Kamiokande to constrain spectral information more strongly in both the accretion and cooling phases. Overall, significant improvements will be made by Hyper-Kamiokande and DUNE, allowing for much more precise determination of ν e spectral parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Amorphous defect clusters of pure Si and type inversion in Si detectors

Si detectors subjected to energetic particle bombardment are known to undergo a deleterious type inversion from n type to p type. The effect is due to defects that trap electrons but the identity of the main responsible traps remains unknown. Using a combination of classical molecular-dynamics simulations and large-scale density-functional theory calculations, we show that amorphous defect clusters formed under particle bombardment are strong acceptors of electrons and may as such well explain the phenomenon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary benchmarks and analysis of boundary conditions in a trenched microstructured silicon radiation detector

Microstructured neutron detectors have the benefit of enhanced neutron detection efficiency as compared to planar devices, achieved by etching 6 LiF-filled trenches on the top surface of a silicon PIN diode. This sensor geometry results in a complex electric field distribution and depletion characteristics within the diode under reverse bias. For the first time on record, the effects of a fixed oxide charge on the microstructured device depletion characteristics and mobile carrier transport is investigated. Prototype detectors were fabricated with non-conformal surface doping. Capacitance voltage and current voltage measurements were performed for these prototypes and compared with COMSOL Multiphysics simulations. A spectral response from an 241Am alpha particle source was acquired and analyzed. It was found that monoenergetic alpha particles produce three prominent peaks in the pulse height spectrum output by the device. The peaks were confirmed by simulations to correlate with dead layers and incident trajectories into the microstructure. It was also found that significant differences in pulse rise time result, corresponding with events arriving in a low-field region in the fins and a high-field region in the bulk. Geant4 was utilized for radiation transport, interaction modeling, and benchmarking the spectral data. The results of this simulation work provide confidence in the ability to attain and benchmark electrical characteristics and spectral data for semiconductor radiation detectors employing complex microstructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗

TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailed circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit simulations and prototyping is expected. Partially supported by NIH grant R01-EB000558. This work was partially supported by NIH grant no. R01-EB000558.

60 APPLIED LIFE SCIENCES↗

Detection prospects of core-collapse supernovae with supernova-optimized third-generation gravitational-wave detectors

We discuss how to optimize the third-generation gravitational-wave detector to maximize the range to detect core-collapse supernovae. Based on three-dimensional simulations for core-collapse and the corresponding gravitational-wave waveform emitted, the corresponding detection range for these waveforms is limited to within our Galaxy even in the era of third-generation detectors. The corresponding event rate is two per century. We find from the waveforms that to detect core-collapse supernovae with an event rate of one per year, the gravitational-wave detectors need a strain sensitivity of 3 × 10 -27 Hz -1/2 in a frequency range from 100 to 1500 Hz. We also explore detector configurations technologically beyond the scope of third-generation detectors. We find with these improvements, the event rate for gravitational-wave observations from core-collapse supernovae is still low, but is improved to one in twenty years.

79 ASTRONOMY AND ASTROPHYSICS↗

A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations

Purpose: To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. Methods: A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was used to simultaneously detect radiation levels across a scan field-of-view. The sampling time was as short as 0.24 ms. To measure the body bow-tie attenuation on a GE Lightspeed Pro 16 CT scanner, the x-ray tube was parked at the 12 o’clock position, and the detector was centered in the scan field at the isocenter height. Two radiation exposures were made with and without the bow-tie in the beam path. Each readout signal was corrected for the detector background offset and signal-level related nonlinear gain, and the ratio of the two exposures gave the bow-tie attenuation. The results were used in the GEANT4 based simulations of the point doses measured using six thimble chambers placed in a human cadaver with abdomen/pelvis CT scans at 100 or 120 kV, helical pitch at 1.375, constant or variable tube current, and distinct x-ray tube starting angles. Results: Absolute attenuation was measured with the body bow-tie scanned at 80–140 kV. For 24 doses measured in six organs of the cadaver, the median or maximum difference between the simulation results and the measurements on the CT scanner was 8.9% or 25.9%, respectively. Conclusions: The described method allows fast and accurate bow-tie filter characterization.

60 APPLIED LIFE SCIENCES↗

High optical efficiency and photon noise limited sensitivity of microwave kinetic inductance detectors using phase readout

We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-antenna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulations of Small-Pore Microchannel Plates for Fast Gated X-ray Imaging and Spectroscopy of High-Energy Density Plasmas

This poster describes work done at National Security Technologies, LLC (NSTec), and Sandia National Laboratories (SNL) over the past several years on the design and characterization of microchannel plate (MCP)-based fast-gated x-ray imagers for use on the SNL Z machine. These cameras use 10-micron-pore MCPs similar to the type used for spectroscopy and imaging applications at other facilities. To aid in the understanding of MCP behavior, we have developed a Monte Carlo simulation model for prediction of MCP response. The code contains a detailed physical model of the electron cascade and amplification process of the MCP that includes energy conservation for the secondary electrons, the effects of elastic scattering of low-energy electrons from the channel wall, and gain saturation mechanisms from wall charging and space charge. Our model can simulate MCP response for both static and pulsed voltage waveforms. Excellent agreement between the Monte Carlo simulations and laboratory measurements has been achieved. Here, we apply our simulation model to 2-micron-pore MCPs, which, while readily available from a variety of vendors, are not used in imaging applications. We investigated the DC and pulsed gain characteristics of such an MCP, with particular emphasis on dynamic range, temporal response, and spatial resolution. The results are compared to the predicted and measured characteristics of 10-micron-pore MCPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-E-18A-08: Towards a Next-Generation Electronic Portal Device for Simultaneous Imaging and Dose Verification in Radiotherapy

Purpose: This work forms part of an ongoing study to develop a next-generation electronic portal imaging device (EPID) for simultaneous imaging and dose verification in radiotherapy. Monte Carlo (MC) simulations were used to characterize the imaging performance of a novel EPID that has previously been demonstrated to exhibit a water-equivalent response. The EPID ' s response was quantified in several configurations and model parameters were empirically validated against experimental measurements. Methods: A MC model of a novel a-Si EPID incorporating an array of plastic scintillating fibers was developed. Square BCF-99-06A scintillator fibers with PMMA cladding (Saint-Gobain Crystals) were modelled in a matrix with total area measuring 150×150 mm{sup 2}. The standard electromagnetic and optical physics Geant4 classes were used to simulate radiation transport from an angled slit source (6 MV energy spectrum) through the EPID and optical photons reaching the photodiodes were scored. The prototype's modulation transfer function (MTF) was simulated and validated against experimental measurements. Several optical transport parameters, fiber lengths and thicknesses of an air gap between the scintillator and photodiodes were investigated to quantify their effects on the prototype's detection efficiency, sensitivity and MTF. Results: Simulated EPID response was more sensitive to variations in geometry than in the optical parameters studied. The MTF was particularly sensitive to the introduction of a 0.5–1.0 mm air gap between the scintillator and photodiodes, which lowered the MTF relative to that simulated without the gap. As expected, increasing the fiber length increased the detector efficiency and sensitivity while decreasing the MTF. Conclusion: A model of a novel water-equivalent EPID has been developed and benchmarked against measurements using a physical prototype. We have demonstrated the feasibility of this new device and are continuing to optimize the design to achieve an imaging response that warrants the development of a next-generation prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inferring small-sample-reactivity worth from oscillation experiment with auto-corrected local flux

To estimate reactivity changes as a function of time from the signal of detectors count rates, one usually uses point kinetic equations. However, when detectors are located inside the core, it is often necessary to compute a correction factor to account for the flux-shape deformation (i.e. the change of detector efficiency that may have been induced by neutron absorbers movements). Various simulation methods have been developed depending on transients observed. They range from the resolution of static equations up to full-time-dependent neutron transport in 3D. However, those methods require high computational-cost calculations of local reaction rates that rely on nuclear data evaluations. Therefore, a 'measured' reactivity is never determined through pure measurements. Taking advantage of the known oscillation movement of a small sample at the center of the MINERVE reactor, the innovative algorithm presented in this paper derives the correction factor needed to get no time drift on reactivity steps. Derived correction factors are in good agreement with those obtained independently with TRIPOLI-4 through sensitivity analysis. Low sensitivity to the sample composition and moderate sensitivity to the detectors position reinforce the reliability of those results. This application paves the way to almost pure nuclear data reactivity measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of radiation beams used to determinate the correction factor for a CyberKnife® unit reference field using ionization chambers

This paper aimed to characterize a 6 MV x-ray beam from a Varian® iX linear accelerator in order to obtain the correction factors needed by the IAEA/AAPM new formalism{sup 1}. The experiments were performed in a liquid water phantom under different irradiation conditions: a) Calibration of the reference field of 10 cm × 10 cm at 90 cm SSD and 10 cm depth was carried out according to the TRS-398 protocol using three ionization chambers (IC) calibrated in different reference laboratory and b) Measurement of the absorbed dose rate at 70 cm SSD and 10 cm depth in a 10 cm × 10 cm and 5.4 cm × 5.4 cm fields was obtained in order to simulate the CyberKnife® conditions where maximum distance between the source and the detector is equal to 80 cm and the maximum field size is 6 cm diameter. Depending where the IC was calibrated, differences between 0.16% and 2.24% in the absorbed dose rate measured in the 10 cm × 10 cm field at 90 cm SSD were observed, while for the measurements at 70 cm SSD, differences between 1.27% and 3.88% were obtained. For the 5.4 cm × 5.4 cm field, the absorbed dose measured with the three ICs varies between 1.37% and 3.52%. The increase in the difference on the absorbed dose when decreasing the SSD could possibly be associated to scattering radiation generated from the collimators and/or the energy dependence of the ionization chambers to low-energy radiation. The results presented in this work suggest the importance of simulating the CyberKnife® conditions using other linear accelerator for obtaining the correction factors as proposed by the IAEA/AAPM new formalism in order to measure the absorbed dose with acceptable accuracy.

43 PARTICLE ACCELERATORS↗

Performance of the CMS Zero Degree Calorimeters in pPb collisions at the LHC

The two Zero Degree Calorimeters (ZDCs) of the CMS experiment are located at ± 140 m from the collision point and detect neutral particles in the |η| > 8.3 pseudorapidity region. This paper presents a study on the performance of the ZDC in the 2016 pPb run. The response of the detectors to ultrarelativistic neutrons is studied using in-depth Monte Carlo simulations. A method of signal extraction based on template fits is presented, along with a dedicated calibration procedure. A deconvolution technique for the correction of overlapping collision events is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark of Neutron Thermalization in Graphite Using a Pulsed Slowing-Down-Time Experiment

A benchmark has been developed using a pulsed slowing-down-time experiment to isolate the thermalization process in graphite. The experiment was conducted at the Oak Ridge Electron Linear Accelerator facility at Oak Ridge National Laboratory, and it measured the time spectrum of neutrons leaking from a graphite pile during slowing down and thermalization within graphite. Simulations of the benchmark experiment were performed using the MCNP6.1 Monte Carlo code and the ENDF/B-VII.1 and ENDF/B-VIII.0 cross-section databases. The benchmark provides a time spectrum (i.e., time-dependent counts in a detector) that allows for validation of the graphite thermal scattering libraries (TSLs). The impact on the simulations using a suite of graphite TSLs was compared with the experimental results. Given the density of nuclear graphite, the TSL corresponding to graphite with 30% porosity, as implemented in ENDF/B-VIII.0, was found to most accurately represent the measured time spectrum corresponding to the thermal energy range with an average deviation of ±1.7%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LLNL Final Design for PDV Measurements of Godiva for Validation of Multi-Physics Simulation

This document is a Final Design (CED-2) Report for IER-268, “PDV Measurements of Godiva for Validation of Multi-Physics Simulation”. These measurements will measure surface velocities in several locations, the initial α and α-t curve as a function of fission yield using existing LLNL assets including: The portable Photonic Doppler Velocimeter (PDV) detector; The “alpha box”, and; Aluminum-encapsulated 235 U fission foils. These experiments will be simulated using multi-physics methods funded separately under LLNL-AM2. A supercritical benchmark specification will be developed; and, if funding permits, an ICSBEP (or classified equivalent) evaluation will be published.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Planck 2018 results: III. High frequency instrument data processing and frequency maps

This paper presents the High Frequency Instrument (HFI) data processing procedures for the Planck 2018 release. Major improvements in mapmaking have been achieved since the previous Planck 2015 release, many of which were used and described already in an intermediate paper dedicated to the Planck polarized data at low multipoles. These improvements enabled the first significant measurement of the reionization optical depth parameter using Planck-HFI data. This paper presents an extensive analysis of systematic effects, including the use of end-to-end simulations to facilitate their removal and characterize the residuals. The polarized data, which presented a number of known problems in the 2015 Planck release, are very significantly improved, especially the leakage from intensity to polarization. Calibration, based on the cosmic microwave background (CMB) dipole, is now extremely accurate and in the frequency range 100-353 GHz reduces intensity-to-polarization leakage caused by calibration mismatch. The Solar dipole direction has been determined in the three lowest HFI frequency channels to within one arc minute, and its amplitude has an absolute uncertainty smaller than 0.35 μK, an accuracy of order 10 -4 . This is a major legacy from the Planck HFI for future CMB experiments. The removal of bandpass leakage has been improved for the main high-frequency foregrounds by extracting the bandpass-mismatch coefficients for each detector as part of the mapmaking process; these values in turn improve the intensity maps. This is a major change in the philosophy of "frequency maps", which are now computed from single detector data, all adjusted to the same average bandpass response for the main foregrounds. End-to-end simulations have been shown to reproduce very well the relative gain calibration of detectors, as well as drifts within a frequency induced by the residuals of the main systematic effect (analogue-to-digital convertor non-linearity residuals). Using these simulations, we have been able to measure and correct the small frequency calibration bias induced by this systematic effect at the 10 -4 level. There is no detectable sign of a residual calibration bias between the first and second acoustic peaks in the CMB channels, at the 10 -3 level.

79 ASTRONOMY AND ASTROPHYSICS↗